Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC | ₹49.6 L | L1 | Accepted-AOC Lowest bid value |
| 2 | L2₹51.7 LRejected-AOC | ₹51.7 L | L2 | Rejected-AOC Higher bid value |
| 3 | L3₹51.9 LRejected-AOC | ₹51.9 L | L3 | Rejected-AOC Higher bid value |
| Sl No | Description | Qty | Unit | M/s K P Enterprises L1 | M/S ORIENTAL MOTORS COMPANY L3 | M/S MUGHATOLI AYE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removal of rubbish off the premises complete all as specified and as directed. | 3.5 | Cum | 700 ₹2,450 | 450 ₹1,575 | 300 ₹1,050 |
| 2.00 | M&L for second class hardwood as in scantlings clean sawn timber fixed including dismantling old timber scantlings 40 sqcm and over in section, in unframed work any position complete all as specified and as directed. | 0.1 | Cum | 67,000 ₹6,700 | 80,000 ₹8,000 | 75,000 ₹7,500 |
| 3.00 | Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches complete all as specified and as directed. | 16.5 | Cum | 1,000 ₹16,500 | 700 ₹11,550 | 800 ₹13,200 |
| 4.00 | Dismantling of wrought iron or mild steel work of any description complete all as specified and as directed. | 14.4 | Qtl | 600 ₹8,640 | 500 ₹7,200 | 300 ₹4,320 |
| 5.00 | M&L for brick work with sub class 'B' bricks (using old size burnt bricks) straight or curved on plan exc 6m mean radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed . | 4 | Sqm | 1,100 ₹4,400 | 1,200 ₹4,800 | 1,150 ₹4,600 |
| 6.00 | S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old asbestos sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed . | 15 | Sqm | 1,100 ₹16,500 | 1,210 ₹18,150 | 1,250 ₹18,750 |
| 7.00 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including dismantling of old asbestos sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed . | 1,000 | Sqm | 1,175 ₹11.8 L | 1,210 ₹12.1 L | 1,250 ₹12.5 L |
| 8.00 | S&F post of Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming Fe 410 -W (Gde- E- 250) quality- A including dismantling of old asbestos sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed . | 100 | Kg | 170 ₹17,000 | 180 ₹18,000 | 165 ₹16,500 |
| 9.00 | M&L for coloured/light shade vitrified ceramic tiles 9-10mm thick (Square / rectangular) of area exceeding 0.18 sqm but not exceeding 0.36 Sqm each, in floors laid over and including 15mm thick screed bed for laying floor finishes in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including demolition of old tiles complete all as specified and as directed. | 60 | Sqm | 1,900 ₹1.1 L | 2,000 ₹1.2 L | 1,950 ₹1.2 L |
| 10.00 | All as per Ser item No 9.00 (here-in-beofre) but as in skirting, laid over & including 10mm thick baking coat in CM (1:4). | 10 | Sqm | 1,950 ₹19,500 | 2,000 ₹20,000 | 1,950 ₹19,500 |
Updated dates
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
25 Oct 2025, 6:00 pmClosed
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
SPL REPAIRS TO BLDG NO T49 VEH REPAIR SHED OF 85 FD WKSP IN N ZONE AT RMS
2025_MES_728859_2
8928/C/E8
Open Tender
Civil Works
180 days
RANGAPAHAR
Class D, Category a(i)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹96,000
12 Jan 2026
7 Oct 2025
27 Oct 2025
7 Oct 2025
25 Oct 2025
13 Oct 2025
7 Oct 2025 - 10 Oct 2025
Amount
Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removal of rubbish off the premises complete all as specified and as directed.
M&L for second class hardwood as in scantlings clean sawn timber fixed including dismantling old timber scantlings 40 sqcm and over in section, in unframed work any position complete all as specified and as directed.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks (using old size burnt bricks) straight or curved on plan exc 6m mean radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed .
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old asbestos sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed .
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including dismantling of old asbestos sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed .
S&F post of Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming Fe 410 -W (Gde- E- 250) quality- A including dismantling of old asbestos sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed .
M&L for coloured/light shade vitrified ceramic tiles 9-10mm thick (Square / rectangular) of area exceeding 0.18 sqm but not exceeding 0.36 Sqm each, in floors laid over and including 15mm thick screed bed for laying floor finishes in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including demolition of old tiles complete all as specified and as directed.
All as per Ser item No 9.00 (here-in-beofre) but as in skirting, laid over & including 10mm thick baking coat in CM (1:4).
M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square / rectangular), area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match shade of tiles, laid over and including 15 mm thick screed bed in CM (1:6) including demolition of old tiles complete all as specified and as directed.
M & L for PCC 25mm thick type B-0, (1:2:4) (using 12.5 mm graded stone aggregate) as in levelling course of floor complete all as specified and directed.
M & L for 100mm thick PCC (1:3:6) type C-2, (using 40 mm graded stone aggregate) as in sub base/hardstanding complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate) in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide that area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-Painted self embossed, textured designer board E-Board Classic to be fixed Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including dismantling of old wall and ceiling boards complete all as specified and as directed.
Taking down chowkhat or frame exc 1.5 sqm not exc 4 sqm each (without taking off shutters from the frame) complete all as specifed and directed.
S&F anodised aluminium powder coated any colour frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S & F powder coated aluminium Window and ventilator shutters, without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified.
S&F aluminium anodised grill with mesh size 75 mm and aluminium bar 6 mm XPM type including all accessories such as channels for fixing grill screws etc, aluminium section 15 micron thick anodizing complete all as specified and directed.
S&F aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
S&F anodised aluminium doors shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats glazing cleat, rubber neoprene packing, handles 2 Nos in each door hinges, anodised aluminium snap beading screws complete all as specified and as directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.
S&F Sheet glass 4.8mm thick clear/sun shade colour glass, ordinary quality and glazing with oil putty in squares exceeding 0.5sqm in each pane complete all as specified and as directed.
S&F 4 mm thick anodised aluminium composite panel fixed in aluminium frame including necessary rubber beading, jointing cleats complete all necessary items to fix with frame and all as specified and directed by Engineer-in Charge.
S&F polythene film, 150 micron thick laid on a coat of bitumen primer, @0.30 to 0.50 kg per Sq.m complete all as specified and as directed.
S&F butt hinges medium grade cold rolled mild steel and fixed size of hinges 100 mm long size complete all as specified and as directed.
S&F Aluminium anodised barrel tower bolt of extruded section and fixed 150 mm long complete all as specified and as directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) using water proofing compound @ 3% by weight of cement for finished even and smooth without using extra cement including taking down old plaster from its position complete all as specified and as directed. Note: WPC will be measured and paid separately.
Supply only Integral water proofing compound complete all as specified and as directed.
M&L for 10mm thick cement plaster in cement mortar (1:6) on brick or concrete surfaces of wall surfaces finished fair and even and smooth without using extra cement including taking down old plaster from its position complete all as specified and as directed.
M & L for Preparing the new plastered surfaces of walls ,and applying two coats of exterior weather paint over a coat of primer over a coat of 2mm thick wall care putty(in two layers) on wall surface complete all as specified and as directed
M&L for complete removal of exisitng treatment of old decorated surfaces of wall applying two coats of exterior weather paint over a coat of primer over a coat of 2mm thick wall care putty(in two layers) on wall surface upto 3 storeyed bldg complete all as specified and directed.
M&L for applying two coats of oil bound distemper over a coat of primer over a coat of 2mm thick wall care putty (in two layers) on new plastered surfaces of walls including preparation of new surface complete all as specified and as directed.
M&L for complete removal of exisitng treatment of old decorated surfaces of wall applying two coats of oil emulsion distemper over a coat of primer over coat of wall care putty(2 mm thick in two layers) for obtained smoothness of wall surfaces complete all as specified and as directed.
M&L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper of approved shade/tint complete all as specified and as directed.
M&L for brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan exc 6 m mean radius in CM (1:6) complete all as specified and directed.
M&L for cement concrete type C-2 (1:2:4) (using 20 mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed.
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds complete all as specified and as directed.
S&F in repairs steel rolling shutters but gear operated type with bevel gear box and crank handle of thickness of laths 1.25mm, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete pull or manual type complete all as specified and as directed.
S&F ball bearing for rolling shutters complete all as specified and as directed.
S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed.
S&F Steel windows or ventilators fixed type with glazing bars dove-tailed or welded complete all as specified and as directed.
S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall complete all as specified and as directed.
M&L for framed work such as grills, gratings etc framed guard for fixing arrangement for wire cloth etc conforming to Fe 290 Gde E-165 complete all as specified and as directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed.
M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tint complete all as specified and as directed.
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide on old surfaces in any tint complete all as specified and as directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410 -W (Gde-E- 250) quality-A complete all as specified and as directed.
S&F in repairs for Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and rings complete all as specified and as directed.
Material and labour for point wiring in repairs including necessary chases cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) PVC sheathed multistranded copper conductor cable 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping with all accessories and sunk modular GI box for mounting of fittings like switch, socket and fan regulator with modular inner plate and cover plate and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge
One light point controlled by one, one way switch .
One Ceiling fan/ exhaust fan point controlled by one, one way switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on the Independent board.
All as per item No- 52.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
All as per item No-52.00 here-in-before but with 4.0 Sq mm for AC point controlled by 4.0 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
S&F Switch Piano, flush type single pole, one way 5 Amps complete all as specified and as directed.
S&F Switch Socket combination, 2 in 1, 5 pin 6A flush type complete all as specified and as directed.
S&F Socket outlet 3 pin, 6A, flush type complete all as specified and as directed.
S&F Switch Socket combination, 2 in 1, 3 pin 6A/16A flush type complete all as specified and as directed.
S&F stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet complete all as specified and as directed.
M& L for sub main wiring with two runs of 2.5 Sq mm and one run of 2.5 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC conduit complete all as specified and as directed. NOTE:- two runs of 2.5 Sq mm + one run of 2.5 Sq mm and one run of PVC Conduit and its accessories of suitable size shall be measured as one unit length.(Sub TPN DB to SPN DBs for High bay lighting flood light)
M& L for sub main wiring with two runs of 6.0 Sq mm and one run of 6.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC conduit complete all as specified and as directed. NOTE:- two runs of 6.0 Sq mm + one run of 6.0 Sq mm and one run of PVC Conduit and its accessories of suitable size shall be measured as one unit length.(Sub TPN DB to SPN DBs)
M& L for sub main wiring with two runs of 4.0 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC conduit complete all as specified and as directed. NOTE:- two runs of 4.0 Sq mm + one run of 4.0 Sq mm and one run of PVC Conduit and its accessories of suitable size shall be measured as one unit length.(submain for AC)
M& L for sub main wiring with two runs of 10.0 Sq mm and one run of 10.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC conduit complete all as specified and as directed. NOTE:- Two runs of 6.0 Sq mm + one run of 6.0 Sq mm and one run of PVC Conduit and its accessories of suitable size shall be measured as one unit length. (Sub TPN DB to SPN DBs)
M& L for sub main wiring with two runs of 1.5 Sq mm and one run of 1.5 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC conduit complete all as specified and as directed. NOTE:- two runs of 1.5 Sq mm + one run of 1.5 Sq mm and one run of PVC Conduit and its accessories of suitable size shall be measured as one unit length. (SPN DB to light point )
S&F in repairs 20W LED, 4', Wall mounted LED tube light fitting batten with LED single side or double side connection, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and as directed.
S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling and connecting up with driver, three core flexible copper conductor of suitable size complete all as specified and as directed.
M&L for Rigid non-metallic 40mm dia PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks complete all as specified and as directed.
S&F ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and as directed.
S&F in repairs Building Security LED 25W light fitting, drawn through including GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling holes as required and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and as directed.
S&F in repairs VTPN DPX 4 way,double door 415 Volts, 50 Hz, IP 43 IK 09 sheet steel, powder painted, with 02 neutral link & 02 earth bar and cable ties for cable management suitable for fixing of MCCB as incomer and MCB SP/TP as outgoing MCB DBs incl taking down of old UNSV DBs and making good the disturbed surfaces to match with existing specification, complete all as specified and as directed.. Note : MCBs will be measured and paid separately.
Supply and fixing 415V MCCB 4 pole 125 Amp 16 KA current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
S&F in repairs MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv DB and making good the disturbed surfaces to match with existing specification , complete all as specified and as directed.. Note : MCBs will be measured and paid separately.
S&F in repairs MCB Distribution board double door type SPN 12 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv DB and making good the disturbed surfaces to match with existing specification , complete all as specified and as directed.. Note : MCBs will be measured and paid separately.
S&F in repairs MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv DB and making good the disturbed surfaces to match with existing specification , complete all as specified and as directed.. Note : MCBs will be measured and paid separately.
S&F in repairs MCB Distribution board double door type SPN 2 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv DB and making good the disturbed surfaces to match with existing specification , complete all as specified and as directed.. Note : MCBs will be measured and paid separately.
S&F in repairs MCB SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DB complete all as specified and as directed.
S&F in repairs MCB SPN 40-63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DB complete all as specified and as directed.
S&F in repairs MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning MCB DB complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
Taking down and refixing of Window/Split Air conditioner units indoor/outdoor complete with cordless remote control and with inbuilt air ioniser and Plasma filter for better indoor air quality with twin rotary compresser three phase units 230 volts 50 Hz of capacity 1.5/2.0 TR With eco friendly refrigerent. Note :- (i) Cutting holes in walls/ Window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate . (iii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer included in above rate. (ii) copper piping/ drain piping included in above rate.
Taking down industral fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearing, painting of fans complete with superior quality synthetic enamel paint by spraying including filling cavaties with filler, after cleaning all dust, reassembling the fan and blades, hanging/ fixing the fan in its original position and testing on completion complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200mm sweep. Minimum air delivery 210 CFM with service value not less than 5.1 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Repair/maint of existing LT panel board by dismantling all cable connection i.e incoming and outgoings and trenching out of loop of cable by digging, cutting burnt portion of cable, cleaning and fixing of lugs with crimping tool, cleaning of bus bar with emery paper, tightening of bus bar with busbar insulators, re-fixing of cable with busbars, by providing new bolts, nuts and washers cable lugs to be provided for all incoming and outgoing cables includig spray painting smoke grey paint 2 coats complete all as specified and as directed.
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 3.5 core including taking out old unsv cable complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 95 Sqmm, 3.5 core including taking out old unsv cable complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed.
M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: Punned down thickness shall be measured and paid.
Supply & laying tubes ' light grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 50 mm dia bore including taking down corroded GI tubing complete all as specified and as directed.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker MCB TPN 40 to 63 Amps (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as ditected.
Supply and fixing for Gazella highbay 150 Watt Energy saving, environment friendly & robust ediumbay /Highbay LED luminaire with high efficacy with toughened glass/PC complete all as specified and as directed.
Supply and fixing LED flood light 220 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. NOTE:- (i) The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber, CI cover 10 mm thick, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M/S MUGHATOLI AYE (BID ID -3452903)
M/S ORIENTAL MOTORS COMPANY (BID ID -3450245)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
BOQ_822015.xls
BOQ • 0.38 MB
Tender8928.pdf
Tender Documents • 1.67 MB
Download all tender documents and submit your bid