Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.4 L+₹94,345.90 (2.03%)Rejected-Finance 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹47.5 L+₹1.0 L (2.16%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹48.6 L+₹2.1 L (4.53%)Rejected-Finance NO 18 8 254 26 RAKSHAPURAM SAIDABAD POST HYDERABAD 500 005 | HYDERABAD | HYDERABAD | TELANGANA | 500005 | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹49.9 L+₹3.4 L (7.31%)Rejected-Finance | L5 | Rejected-Finance NOT L1 |
Tender Value
₹53.6 L
EMD Value
₹1.1 L
Closing Date
5 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
REPAIR TO BLDG NO E-7, 12 AND E-13 REQUIRED WORKS AS FLOOR REPAIR (INCLUDING TILLING), DOORS WINDOWS CHANGE OF BROKEN AC SHEETS AND REPLACEMENT OF LIGHT POINT WITH ALL ELECT CONNECTION AND MAINT AT 2 TRG BN OF AOC CENTRE UNDER GE (SOUTH) SECUNDERABAD
2020_MES_373578_1
CWE(S)/SOUTH/TOKEN-16 OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
Secunderabad
As per NIT
6 documents required · 6 mandatory
₹1,000
GE (South) Secunderabad
₹1.1 L
Yes
20 Oct 2020
31 Aug 2020
8 Oct 2020
31 Aug 2020
5 Oct 2020
22 Sept 2020
60 days
Amount
Dismanting ceiling board of insulation boards etc any thickness including cover filter complete all as specified and directed
S & F anodised aluminum snap grid 605 x 605mm for false ceiling work all as specified and directed
M & L 4mm asbestos cement plain building boards, fixed on ceiling frame work including two coats of OBD over the ceiling surfaces complete all as directed.
S & F hangers 6mm dia GI (upto 1200mm long) adjusting level fixed to roof slabs by means of ceiling cleats made as per site condition long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed
Taking down cement plaster on brick or stone walls etc including racking out joints hacking for keys scrubbing down with water etc complete all as specified and directed
Demolition of brick work or stone/boulder masonry built in cement mortar including all quions arches, pillars etc complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area n.exc 1.50 Sqm each complete all as specified & directed.
All as per item No 7.00 above but area exc. 1.5 sqm n.exc 4 sqm each completed all as specified and directed.
Demolition of cement concrete in ground floors and paving n.exc 15cm thickness (below & above ground level) completed all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and as directed
M & L rendering 15mm thick on fair faces or brick work or concrete surfaces in CM (1:4) including finised the surfaces smooth and even without using extra cement complete all as specified and directed
S & F Non skid coloured cermic tiles 7 to 8mm thick (square or rectangular) area off each tile exc. 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and painted in white cemnent to match incuding 15mm thock screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes complete all as specified and directed
All as per item No. 12.00 but vertical sevices over 10 mm thick backing coat as in CM (1:4) complete all as specified and directed
M & L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone agregate) finished fair & even as in sub base flooring completed all as specified and directed.
M & L for PCC 75mm thick type C1 1:3:6 (using 20mm graded aggregate) as in plinth protection laid in pannels including finished the surface smooth and even without using extra cement complete all as specified and directed
M & L for brick work with fly ash bricks, straight or curved on plan exc. 6 mtr mean radius built in CM (1:6) complete all as specified and directed.
S & F 2nd class hardwood 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauxe, etc. (without sash bars, edge of framing plain, chamfered or rounded, fitted with cut and mitred bes for securing glass, etc: sizes of members of shutters as aspecified in SSR Part-I, Section 8. clause 8.20 (a) : supplied and fitted to chowkats complete all as specified and directed
S & F 2nd class hardwood 35mm thick, plain framed pannlled shutters (any number of panels) with panesls of timber flat on both sides or of veneered particle boared medium density, wood particle board with commercial face venners fitted to chowkats complete all as specified and directed
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy and fixed to shutter complete all as specified and directed
S & F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed and fix to shutter complete all as specified and directed
S&F 150 mm long aluminium handles, cast type, anodised and fix to shutter complete all as specified and directed
S & F steel window with frame, side hung shutters incluidng projecting type hinges with steel handle and peg stays with glazing bars, devotailed or welded complete all as specified and as directed
S & F steel window with frame, side hung shutters incluidng projecting type hinges with steel handle and peg stays with glazing bars, devotailed or welded complete all as specified and directed
M & L for framed work such as grills, gratings etc with ends of bars, framed guard bars, ladders etc and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed
S & F galvanized mild steel wire cloth 0.56mm nominal dia of wire avg 1.18mm width of aperture and fixed with tinned tacks complete all as specified and directed
S & F pressed steel frame for doors with one or more rebae using 1.25mm thick MS sheet including necessary fixing lugs, hinges the plate etc complete profile 'A' size 125x60 mm complete all as specified and directed
S & F 4mm thick sheet glass, ordinary quality, glazing with oil putty in square panes, not exc, 0.50 sqm each pane complete all as apecified and directed
Dismantling asbestos cement (Corrugated, semi corrugated, etc) sheets in roof convenings complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed
S & F Roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc confirming to grade Fe-410 W E250 quality A complete all as specified and directed
All as per Item No.30.00 but febrication, errection and fixing only
S & F pre painted galvalume aluminum Zink coating GI bases corrugated steel sheeting 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed
All as per item No. 32.00 but plain steel sheet for ridges complete all as specified.
M & L for preparation of new wooden surface and applying 2 coats of synthetic enamel paint over one coat of pink primer over 10 cm width or girth completer all as specified.
M & L for applying two coats of oil bound distempers on new surface of walls over a coat of primer including 2mm thick wall care putty complete all as specified and directed.
M & L preparation of new surfaces of walls plastered etc and applying two coats of cement based paint on wall surraces as specified.
M & L for complete removal of existing surface and applying wall care putty 3mm thick over two coats of oil bound distempers and one coat of primer on wall complete all as specified and directed.
M & L preparation of old surfaces of walls plastered etc and applying two coats of cement based paint on wall surraces as specified.
M & L for preparation of new surfaces of steel and iron work of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc primer all as specified.
M & L for preparation of old surfaces of steel and iron work of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc primer all as specified.
M & L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in bed block for hold fasts and filling of chowkat etc including necessary form work complete all as specified and as directed.
M & L for PCC 1:2:4 type B0 (using 12.5mm graded aggregate) as in levelling course including weathering slightly rounded or chamfered angles and throating as directed complete all as specified.
S & F 18-20mm thick kota stone slab as in floors over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish and rounding chamfered edges where directed complete all as specified and directed.
All as per item No. 43.00 above but 16 to 18mm thick kota stone slab as in small width and vertical surraces like landings risers, treads, skirting, dado etc over and including 10mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/ power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified
Taking down the existing unserviceable main switch/cut out/DBs of any type /capacity /description as existing at site including making good the disturbed surfaces to match with the existing finishes all as directed.
M&L for point wiring on concealed conduit complete all as specified with 1100 Volts grade 1.5 sqmm PVC with multistranded copper conducter conforming to IS:694:1990 with ISI markking ( For Phase, Neutral and Earth) in and including non metallic PVC rigid coundit medium grade with ISI mark of size 20 mm dia with all accessories concealed in wall/ceiling/floor/roof etc, for fixing modular switches, sockets, fan regulators etc of suitable modules and earth wire to be connected to commom earth dolly/pressed steel terminal boxes of 1.6 mm thick MS duly painted with red oxide metal primer including fixing/ grouting sunken/ surface as per site requirement covered with 3 mm thick laminated hylam sheet including running up to 1.5 Sq mm copper conducter PVc insulated cable as earth continuiy conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ requlators etc all as soecified for and directed foe the followig :-
(a) One light point controlled by one, one way switch 5A, SP
(b) One ceiling / exhaust fan point controlled by one, one way switch
(c) One 2/3 pin 5 Amps switch socket outlet point controlled by one switch on the same board
(e) One 3 pin 5 Amphs switch socket independent board
All as per item 47 here-in-before but using 4 Sq mm single core copper conducter cable of multistranded PVC insulated 1100 Voltd grade for 6/16 Amps switch socket combination point including running of 4.00 Sq mm copper conducor PVC wire as earth continuity conductor along with wiring and connecting to the commom earth duly.
S & F switch piano type SP, one way, flush type 5 Amps capacity, 230 volts complete all as specified and directed.
Supply and fix switch socket combination flush type multipurpose 2/3 pin 5 Amps, 230 volts complete all as specified.
Supply and fix socket outlet flush type multipurpose 2/3 pin 5 amps, 230 volts all as specified
Supply and fix switch socket combination flush type multipurpose 5 in 1, 5/16 Amps, 230 Volts complete all as specified.
S & F ceiling fan regulator step type AC 240 volt suitable for 1200/1400 mm sweep complete all as specified and directed
S&F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 X 50 mm complete all as specified and directed
S&F 9/10 W LED batten alongwith integrated driver complete all as specified and directed
S&F vertical type TPN DB 4 way double door with 200 Amps rated bus bar 415 volts AC 3 phase 50 Hz suitable for and including 100 Amps TPN 25 KA as incomer and outgoing SP MCB's with fixed magnetic setting with locking arrangement complete all as specified and directed
S&F sheet metal enclosure MCB DB SPN 8 way DB with 200 Amps rated bus bar 240 volts with flush type locking system complete all as specified and directed
S&F MCB SP 6 to 32 Amps 240 volts for fixing in MCB DB's complete all as specified and direcetd
S&F MCB SPN 40 Amps 240 Volts for fixing in MCB DB's complete all as specified.
S&F 45 watt recess softline luminaire (2x2) suitable for armstrong/grid ceiling with high brightness white LEDs and PMMA exturded diffuser giving glare free light and good aesthetic appeal all as specified and directed
S&F box type wall mounted light fittings with LED lamp 20/22 watt complete all as specified.
M&L for sub main wiring with two runs of single core 6 sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of medium grade of 25 mm dia including one run of single core 6 sq mm PVC insulated unsheathed multistranded 1100 Volts grade copper conductor cable as earth continuity conductor alongwith the wiring and connected to common earth dolly including removing the existing unserviceable submain wiring and making good the disturbed surface to match with the existing surface complete all as specified and as directed. Note : 2 runs of 6 sq mm cable, one run of 6 sq mm earth continuity conductor and one run of conduit shall be measured as one unit length.
Earthing complete with galvanised steel earth plate electrode 60cmx 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nuts, checknuts and washers etc., of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/main switch all as shown in Electrical Plate No.5 of SSR Part-I and connected to main switch board including excavation and earth work in hard dense soil, returning in and removal of surplus soil to a distance not exc 50m, PCC chamber in 1:2:4 Type B-1 using 20mm graded stone aggregate, 40mm thick RCC Cover in 1:2:4 type B-1 reinforced with XPM of weight not less than 4 Kg/Sqm and frame of angle iron 25 x 25 x 6 mm with lugs 2 Nos. and with 6mm dia MS bar handle made to shape, 20 mm dia light grade GI watering pipe perforated at bottom 1.75m long with funnel and wire mesh, common salt and charcoal filling, connection to test point made out of bronze/gun metal with fixing arrangement, funnel, wire mesh complete all as specified. (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5m length is deemed to be included in quoted rate.)
Disconnecting and removing ceiling fan of 1200/1400 mm sweep from any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc & testing complete all as specified. Note :- 1. PVC 2 Core copper cable multstandrad of size 0.50 Sqmm from ceiling rose to ceiling fan deemed to be included in the rate quoted by the contractor 2. supply of unserviceable parts for replacement shall be measured and paid seperately in respective items.
M & L Rewinding of burnt ceiling fan of 1200 / 1400mm sweep motor with supper enameled copper wire of suitable size as per details given below of any make, type, model incl transportation (inclusive of material & labour) complete all as specified and directed
Supply only Fan condensor 2.5 mfd capacity 240 Volts
Supply only Sealed ball bearing suitable for ceiling fan of any size
Supply only Rubber bushes with MS clamp,bolt,nut and split pins
S& Lay 40 mm dia GI tubing light grade for hanging down of fan alongwith PCC coverign on both side of wall for stronghold of pipe to carry the fan and downrod to be fixed with clamps and protection of cable at roads crossing/hard standing/pole protection fixed with clamps as per site requirement etc all as specified and directed
S&F Security light of 1x25 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and as directed
Supply, laying, fixing on wall/on pole/in ground or passing through pipe, 1100 Volts grade heavy duty cable with XLPE insulation stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3.5 core 70 sq mm nominal cross section including jointing and testing complete all as directed . Note: Excavation, earth work, GI Protection Pipe, PCC covers & sand shall be measured and paid separately under respective items.
Excavation in trenches not exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for foundations of man holes, laying of poles/stays/cable etc., n.exc. 10sqm on plan and getting out in hard/dense soil complete all as specified and as directed
Supply, spread river sand of approval in cable trenches providing for cable cushioning as directed. NOTE: Punned thickness of sand only will be measured and paid.
Removal of surplus soil to a distance not exc 50 mtrs away and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each in soils all as specified and as directed.
S& Lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm all as specified and as directed.
ATUL ENTERPRISES
A SOMA RAJU
saradhi construction combines
K LAKSHMAN SINGH AND CO
M/s RAMA LAKSHMI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .