Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.79Admitted-Finance | ₹15.79 | L1 | Admitted-Finance |
| 2 | L2₹28.54Admitted-Finance | ₹28.54 | L2 | Admitted-Finance |
| 3 | L3₹31Admitted-Finance | ₹31 | L3 | Admitted-Finance |
| 4 | L4₹33.50Admitted-Finance | ₹33.50 | L4 | Admitted-Finance |
| 5 | L5₹36.40Admitted-Finance 68 AMKAY ENCLAVE RASHMI PARK VASAI EAST THANE MAHARASHTRA 401208 UDYAM MH 17 0002644 27AAGCA6560N1Z8 B R M | PALGHAR | MAHARASHTRA | 401208 | ₹36.40 | L5 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
10 Dec 2025, 12:00 pmClosed
THE DY. DIRECTOR OF HEALTH SERVICES (E AND S)
Central Medical Stores 141, A J C Bose Road, Kolkata 700014
RE E-TENDER FOR PROCUREMENT OF SOME CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
2025_HFW_940744_1
WBHF/CMS/HST/1P-151-2025 /SCI-RT (360_356)/2025/366
Open Tender
Equipments
730 days
KOLKATA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1 L
Yes
23 Feb 2026
6 Nov 2025
10 Dec 2025
6 Nov 2025
10 Dec 2025
25 Nov 2025
Select, Excess (+), Less (-)
Tender Inviting Authority: THE DEPUTY DIRECTOR OF HEALTH SERVICES (E&S), CENTRAL MEDICAL STORES, KOLKATA -700 014
Name of Work: NOTICE INVITING RE E-TENDER FOR PROCUREMENT OF SOME CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
Name of the Bidder/ Bidding Firm / Company :
Sl. No. pack of 50 Pieces. Cat. No. Tentative requirement for the period as per AU Accounting Unit Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic Rate should be as per Clause No. 16(d). of the NIT, PG:12 Rs. P GST in % Excise Duty in % Cess in % Any Other Taxes/Duties/Levies in Rs. P Other Taxes 2in Rs. P IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax in Rs. P Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category in Rs. P TOTAL AMOUNT Without Taxes in Rs. P TOTAL AMOUNT Without Taxes in Rs. P TOTAL AMOUNT In Words
1 Biopsy Gun, TRUS Biopsy Needle(Core Needle biopsy gun)- Tissue biopsy needle, 18 G , 20/25 cm, Biopsy needle/ 14G (10CM,16CM) / 16G (16CM) / 14G (10CM,16CM,20CM) B8.01(a)/C 4000 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
2 Biopsy Gun, Kidney Biopsy Gun 10X16G B8.08/C 3000 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
3 Double Layered (3 ply) Washable Green Mask. D29.01/C 100000 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
4 Disposable dual heated neonatal and pediatric ventilator circuit: • The circuit should be compatible with Infant Ventilator with flow > 4 L/min as well as < 4 L/ min. • The circuit should be dual-heated. • The length of inspiratory limb should be at-least 1 m and should be supplied with 0.3 m incubator extension. • It should have an autofeedhumidifier chamber. • The expiratory tube should have heating element with-in the circuit in-order to avoid condensation or rain drop-out. • The length of expiratory limb should be at-least 1.5 m. • It should have humidifier connection tube with NO port, swivel wye-piece, pressure line, different adaptors for ventilators in use in various hospitals (Drager/Maquet& SLE ventilators). • Limbs shouldn’t made with natural rubber latex. • It should be disposable according to hospital protocol. D32.01/C 1200 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
5 SUCTION MACHINE & APPARATUS : Powder Coated Mild Steel Cabinet • Rotary Vane Type Pump with -710 ± 10 mm Hg • Noise level of suction apparatus is 50 dB ± 03 dB • 2 X 2.0 Ltrs. Glass jars with overflow safety device • Free air displacement 28 ~ 33 Ltrs • Electrical Requirement - 220~230VAC, 50Hz, 1Phase • Heavy duty HN-50 Castors • 1/2 H.P. Crompton motors. • 63 mm Vacuum Gauge • Non collapsible Suction Tubing H26.01/C 600 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
6 High Flow Nasal Cannula–Newborn, Infant, & Paediatric: The cannula should be anatomically contoured to fit preterm, term neonates, infants and pediatric population. Nasal cannula diameter should be suitable to fit preterm, term neonates, infants and pediatric population to deliver wide range of flows to allow flexibility of treatments. Suitable for delivery of flows between 2-25 l/min. Made of soft material to minimize nasal trauma & should be made of free tubing’s materials e.g. latex free / thermoplastic elastomer (TPE) / Medical PVC. Should have adhesive that stick on skin to secure prongs. The material of adhesive tape should be suitable for use in preterm neonates (preferably hydrocolloid). Adhesive pads should be easily replaceable in case of long duration use. H27.01/C 1200 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
7 MICROPIPETTE , AUTOMATIC FIXED VOLUME DISPENSER OF DIFFERENT VOLUME WITH SPARE PARTS 10, 20, 50, 100, 200, 500, 1000 MICRO LITRE IS 4364, IS 5155 M7.02/C 500 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
8 APD Cassette 4 Prong Specification : Automated PD set W/4 Prong cassette ; 4 inlets ; 1 outlet; 1 patient connect more than 5ft tube; compatible with APD cycler A24.01/C 324000 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
9 CA 250 Line Specification: CA 250 Line - Prismaflex Calcium line/ CA250 lines: Used with Regional Citrate Anticoagulation for compensating patients Calcium C45.01/C 600 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
10 Manual PD Drain Bag 2 Lits Specification: CAPD Sample disconnect set for 2 Its compatible PD bags compatible with patient used transfer set M31.01/C 648000 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
11 Oxiris Specification: Having three layers for removing Cytokines, Endotoxins and performing CRRT altogether. AN69 layer removes Cytokines, PEI layers remove Endotoxins and a Heparin graft is present for maintaining thrombogenecity. Applicable for more than 30kg patient. Filter surface area 1.5m2. Extracorporeal Blood Bolume: 193ml. Specifically indicated for Sepsis+AKI O21.01/C 200 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
12 PD Drain Bag 15 Lts (In pairs) Specification: Cycler Drainage set / 15 its APD drain bag ; compatible with patient used 4 prong APD cassette P83.01/C 648000 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
13 Peel apart Introducer for Tenckhoff catheter Specification: 16 Fr. Pull Apart sheath and dilator, introducer needle, guide wire all compatible with 31, 37 and 42 cm Tenckhoff PD catheter P84.01/C 600 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
14 Peritoneal Dialysis Catheter Set w/2 Cuffs 57 CM coiled Specification: Catheter 57cm straight with coiled tip; should come in a sterile pack, numerous inflow/outflow holes, made of translucent medical grade silicon rubber, radiopaque stripe, Beta-cap adapter, Beta-cap clamp, Two attached cuffs. P85.01/C 300 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
15 Peritoneal Dialysis Catheter Set w/2 Cuffs 62 CM coiled Specification: Catheter 63 cm straight with coiled tip; should come in a sterile pack, numerous inflow/outflow holes, made of translucent medical grade silicon rubber, radiopaque stripe, Beta-cap adapter, Beta-cap clamp, Two attached cuffs. P85.02/C 300 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
16 Prismaflex HF20 Specification: Filter having PAES Membrane for more bio compatibility, Applicable for 8-11kg patient. Filter surface area 0.2 m2. Extracorporeal Blood Volume: 58ml. P86.01/C 250 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
17 Prismaflex M60 Specification: Filter having AN69 Membrane , Applicable for 11-30kg patient. Filter surface area 0.6m2. Extracorporeal Blood Bolume: 93ml. P86.02/C 250 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
18 Prismaflex M100 Specification : Filter having AN69 Membrane , Applicable for more than 30kg patient. Filter surface area 0.9m2. Extracorporeal Blood Bolume: 152 ml. P86.03/C 250 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
19 Prismaflex M150 Specification : Filter having AN69 Membrane , Applicable for more than 30kg patient. Filter surface area 1.5m2. Extracorporeal Blood Bolume: 189 ml. P86.04/C 250 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
20 Quinton Catheter Accessories Specification : HD permanent single cuff staggered tip catheter double lumen straight 14.5 Fr (tip to cuff 19cm, right side); Catheter should come in a kit with carbothane/Silicon Catheter, introducer needle, guide wire, syringe, dilator, island dressings, sealing caps and 16 Fr. Pull Apart sheath and Tunneling stylet.Flow Rate min 450 ml/min Q1.01/C 300 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
21 Soft Tenckhoff PD Catheter 37 cm Straight double cuff. Specification : Catheter 36cm straight ; should come in a sterile pack, numerous inflow/outflow holes, made of translucent medical grade silicon rubber, radiopaque stripe, Beta-cap adapter, Beta-cap clamp, Two attached cuffs. S143.01/C 300 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
22 Soft Tenckhoff PD Catheter 42 cm Straight double cuff. Specification : Catheter 42-43cm straight ; should come in a sterile pack, numerous inflow/outflow holes, made of translucent medical grade silicon rubber, radiopaque stripe, Beta-cap adapter, Beta-cap clamp, Two attached cuffs. S143.02/C 300 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
23 Stiff PD catheter (Paediatric) Specification : Stiff Tenckhoff-type catheter for peritoneal dialysis (PD), suitable for surgical, laparoscopic, or percutaneous insertion. Designed for optimal inflow/outflow, with biocompatible materials for temporary or permanent access. Material (• Medical-grade biocompatible silicone • Non-toxic, non-pyrogenic, latex-free, DEHP-free •Radiopaque for X-ray visibility)• Straight or curved configuration with double Dacron cuffs • Multiple side holes near tip for optimal dialysate flow • Includes removable/fixed stiffening wire or stylet. Outer Diameter (OD)-3.5–4.5 mm (10–12 Fr).Length - 30–36 cm. Cuff Position- Proximal: 1–2 cm from exit , Distal: 6–8 cm from tip.Two (double cuffed), Straight (preferred). Accessories(• Stylet or stiffening wire • Tunneler • Trocar (if applicable) • Transfer set connector/adaptor • End cap • Sterile pack with user manual)• ETO sterilized or equivalent • Shelf life: Minimum 3 years • SAL: 10⁻⁶. • CE marked / US FDA / CDSCO approved • Manufacturer must be ISO 13485 certified.• Individually sterile-packed • Label must include product code, size, expiry, batch number, manufacturer, sterilization method.• Supplier to provide user training/demo if needed • Certificate of Analysis (CoA) and sterility certificate with each batch • Warranty against manufacturing defects S144.01/C 720 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
24 Stiff PD catheter (Adult) Specification : Stiff Tenckhoff-type catheter for peritoneal dialysis (PD), suitable for surgical, laparoscopic, or percutaneous insertion. Designed for optimal inflow/outflow, with biocompatible materials for temporary or permanent access. Material (• Medical-grade biocompatible silicone • Non-toxic, non-pyrogenic, latex-free, DEHP-free •Radiopaque for X-ray visibility)• Straight or curved configuration with double Dacron cuffs • Multiple side holes near tip for optimal dialysate flow • Includes removable/fixed stiffening wire or stylet. Outer Diameter (OD)-4.5–5.5 mm (14–16 Fr).Length - 42–48 cm. Cuff Position- Proximal: 1–2 cm fr om exit ,Distal: 8–10 cm from tip. Two (double cuffed), Straight or Curved. Accessories(• Stylet or stiffening wire • Tunneler • Trocar (if applicable) • Transfer set connector/adaptor • End cap • Sterile pack with user manual)• ETO sterilized or equivalent • Shelf life: Minimum 3 years • SAL: 10⁻⁶. • CE marked / US FDA / CDSCO approved • Manufacturer must be ISO 13485 certified.• Individually sterile-packed • Label must include product code, size, expiry, batch number, manufacturer, sterilization method.• Supplier to provide user training/demo if needed • Certificate of Analysis (CoA) and sterility certificate with each batch • Warranty against manufacturing defects 720 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
25 S144.02/C ENDOTRACHEAL TUBE, Double Lumen Endotracheal Tube: 1. Sizes: Left & right (assorted)2. Soft round Bever tip to minimize trauma to patients. 3. Should contain intubation stylet and super slip suction catheter. 300 EACH Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
26 E5.02/C ECG PAPER ROLL FOR TWELVE (12) CHANNEL ECG MACHINE. Size- 210 mm X 20mtr. 20000 PACK OF 12 PCS Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
27 E3.01/C Oxygen delivery musk : 1. Vinyl soft mask with shouldered crush resistant 2mtr, 2. oxygen tubing 200000 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
28 O15.01/C Oxygen Mask, vinyl o2 mask with pre mounted star lumen crush o2 tubing 50000 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
29 O16.01/C CVC 3 Fr. with Anti Kinking Nitnol Guide Wire (Paediatric)- 6CM/10CM * 3Fr. Thermosensitive Polyurethane Double Lumen Paediatric CVC. * It has Anti Kinking Nitnol Guide Wire 3000 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
30 C75.01/C DISPOSABLE NEEDLES 23G 3000 C44.04/C Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
31 Pack of 100 PCS DISPOSABLE NEEDLES 24G 10000 C44.04/C Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
32 C44.05/C DISPOSABLE NEEDLES 26G 3000 C44.04/C Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
33 C44.07/C Capillary tubes Specifications: 1. The Capillary tubes should be specifically designed for use with Siemens Epoc Blood Gas Analyzers. 2.The tubes should be compatible with Siemens Epoc Blood Gas Analyzers. 2. The tubes should be designed for collection, transportation and dispensing of samples for blood gas analysis. 3. The tubes should contain a suitable anticoagulant (e.g., Calcium balanced heparin) to prevent clotting and ensure accurate test results. 4. The tubes should be made of a durable, non-reactive material that minimizes the risk of sample contamination. 5. The tubes should have clear labeling and instructions for use. 200000 BGA-01/1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
34 Supraglottic Airway Device 2nd generation Specification : 1. Cuff-should be made from soft gel like material ( Medical grade thermoplastic elastomer) that should create a non-inflatable, anatomical seal of the pharyngeal, laryngeal and perilaryngeal structures. 2. 15 mm connector. 3. Position guide 4. Gastric channel / drainage port. 5. Bite block 6. Buccal cavity stabilizer 7. Epiglottis blocker 8. Display of size – for quick, easy reference and weight guidance. 9. Can be used as a conduit for intubation. 10. Size 1,1.5,2,2.5,3,4,5. I11.01/C 400 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
35 Oximetry Cable for CCO Monitor (Reusable) O9.01/C 60 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
36 Plasma Filter for Plasmapheresis P4.01/C 200 EACH Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
37 Platinum Chromium Coronary Stent System P82.01/C 100 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
100 Important Note: 1. All prospective bidders are requested to quote the rate in BOQ AS PER ACCOUNTING UNIT (AU) REPEAT AS PER ACCOUNTING UNIT (AU) & item specifications as mentioned in the Table-1. WRONG QUOTING OF THE RATE in BOQ will be dealt with as per penal provisions of the T&C of the Tender. 2. Quality of the product supplied, may be ascertained by testing / physical examination by the experts at any stage of the tender period. 3. The equipment should be US FDA/ CE/ BIS/ CDSCO approved (US FDA/ CE requirements will be applicable only when the Indian Standards like BIS/ CDSCO is not available). 4. The prospective Bidders of the said Tender are requested to make a declaration in Affidavit under Annexure VI(b) in case of sole manufacturer/importer (i.e. proprietary in nature). 5. If the Item(s) under sole manufacturer / importer is (are) Proprietary in nature, quarterly intimation is solicited from the approved Bidders positively regarding the status of their Item(s) Proprietary in nature, otherwise their Item(s) will be blocked in the SMIS. 6. In case of Tie Bid, decision will be taken by the TIA as per G.O. No. 2320-F(Y), dated 07.06.2022 issued from Finance Department Audit Branch (Group T). 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select %
Quoted Rate in Words
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.09 MB
BOQ_2225205.xls
BOQ • 0.31 MB
Technical_Data_Sheet_366.xls
Tender Documents • 2.76 MB
Download all tender documents and submit your bid