| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls | |||||
| 1.01 | Dismantling Brick work | 13 | M3 | - | - |
| 1.02 | Wall plastering chipping | 290 | M2 | - | - |
| 1.03 | Dismantling Floor tiles | 390 | M2 | - | - |
| 1.04 | Dismantling Existing False ceiling & Partition | 140 | M2 | - | - |
| 1.05 | Dismantling RCC | 2.25 | M3 | - | - |
| 1.06 | Dismantling Pressed tiles and Weathering Course | 255 | M2 | 30 | ₹7,650 |
| 2 | Removing all the corroded dust particles in the reinforcement carefully & check the reinforcement (i.e) the Dia of rod should not be corroded more than 20% of orginal dia using vernier caliper, if the dia of corroded rod exceeds more than 20%, additional strengthing will be provided equvalent to the orginal dia of rod. After strengthing Anti corrosive Fosrec Nitrobond coating will be applied over all the exposed surface. The rate inclusive of both labour and material. | 35 | M2 | - | - |
| 3 | Supply and providing Fosrec Rendro chemical micro concrete over the anti corrosion coating of required thickness to match the orginal surface level. The rate inclusive of scoffolding, labour and material etc., | 35 | M2 | 28 | ₹980 |
| 4 | Anchoring of steel reinforcement bars into concrete, including drilling holes to a depth typically 10–15 times the rebar diameter using a rotary hammer drill with carbide-tipped bits; thorough cleaning of the drilled holes using compressed air and brushes to remove all dust and debris; preparation and injection of approved chemical adhesive or grout into the holes; insertion of reinforcement bars with a twisting motion to ensure proper bonding; ensuring correct alignment and specified embedment length; and allowing the anchors to cure undisturbed for the period recommended by the manufacturer, all complete as per specifications | 20 | Nos | - | - |