Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹43.0 LAdmitted-Finance H NO 1215 NEAR RAM MANDIR PONTEMOL CURCHOREM GOA 403706 | SOUTH GOA | GOA | 403706 | -6.20% | ₹43.0 L | L1 | Admitted-Finance |
| 2 | L2₹43.8 L+₹78,012.67 (1.81%)Admitted-Finance MENEZES BHAT ST JOSE DE AREAL NESSAI CURTORIM MARGAO GOA 403709 | MARGAO | SOUTH GOA | GOA | 403709 | -4.50% | ₹43.8 L+₹78,012.67 (1.81%) | L2 | Admitted-Finance |
Tender Value
₹45.9 L
EMD Value
₹91,780
Closing Date
21 Mar 2026, 5:00 pmClosed
Execututive Engineer
O/o The Executive Engineer, Electricity Department, Div-VII,Curchorem
work of Renovation and Improvement of Low voltage at Fonkulem village in village Panchayat Sanvordem, under the jurisdiction of Elect. Sub Div-IV, Div-VII, Curchorem
2026_ED_27916_1
Tender-10(25-26)
Open Tender
Electrical Works
Percentage
90 days
Fonkulem, V.P Sanvordem
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,500
₹91,780
O/o The Executive Engineer, Curchorem
7 Apr 2026
24 Feb 2026
23 Mar 2026
24 Feb 2026
21 Mar 2026
6 Mar 2026
25 Feb 2026 - 4 Mar 2026
5 Mar 2026
Material Cost (Materials which are shown under erection & which are not shown under material will be supplied departmentally.
Supply of RCC pole 9mtrs long 9meters long R.C.C. Pole conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date. Ordinary Port land cement 53 grade IS 12269 Aggregate IS 383-1970 Torsteel IS 1786-7985 MS bar IS 432 P 1&2-1982 The minimum ultimate transverse load of pole shall be 300Kg for 9mtr. RCC Pole respectively and factor of safety shall be 2.5. The pole shall be marked as per IS. The poles shall be tested as per IS 785 & 2905-1989 as amended upto date at the manufactures works in the presence of the departmental representative and test reports shall be furnished for acceptance. The poles will be accepted subject to passing of tests and verification of reinforcement and concrete after breaking one pole from each lot at cost of the manufacturer.
Supply of RCC pole 7.5mtrs long 7.5meters long R.C.C. Pole conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date. Ordinary Port land cement 53 grade IS 12269 Aggregate IS 383-1970 Torsteel IS 1786-7985 MS bar IS 432 P 1&2-1982 The minimum ultimate transverse load of pole shall be 250Kgs for 7.5mtr. RCC Pole respectively and factor of safety shall be 2.5. The pole shall be marked as per IS. The poles shall be tested as per IS 785 & 2905-1989 as amended upto date at the manufactures works in the presence of the departmental representative and test reports shall be furnished for acceptance. The poles will be accepted subject to passing of tests and verification of reinforcement and concrete after breaking one pole from each lot at cost of the manufacturer.
Supply of complete for 9 mtr RCC pole HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, break insulator of 15KV/8KV, HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. GI stay rod of 1800mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanized. GI stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanized. GI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments. Two nos of GI square washer of size 40x40x6mm to suit the 16mm dia GI rod. Two nos of GI hexagonal nut and bolt suitable for threaded portion of the stay rod mentioned above and conforming to IS-1365/67 with amendment No-1. All the GI materials shall conform to IS-226/75 with amendment No- 1 to 3 tested quality. The breaking load shall be 63KN min proof load (40% of breaking load shall be performed on all the stay sets. These figures have been taken from IS-16/74 with amendment . Turn buckle with eye bolts for 11KV line & conforming to the following. One no of turn buckle made out of 16mm dia GI rod and 50x50x6mm M.S. angle galvanized. One eye bolt made out of 20mm dia GI rod with 40mm inner dia eye at one end threaded up to 300mm length from the other side. Two no’s GI nuts suitable for the threaded portion of eye bolt material specification IS-226/77 (tested quality) The breaking load and proof load shall be as per BS16/64 with amendment No-1. GI wire with tensile strength 32Kg/mm to 55Kg/mm soft quality 4.00mm dia 8SWG wire should conform to ISS-280/1972 and galvanized to heavy type as per ISS-4826/1968 with up to date amendments. The strain insulators shall be sound, free from defects, thoroughly vitrified & smoothly glazed & shall comply with the IS: 5300-1969 or the latest version thereof. The L.T. strain insulator shall have a minimum failing load of 44KN.
Supply and providing Stay sets complete for 7.5 mtr RCC pole HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, break insulator of 15KV/8KV, HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, conforming to drawings approved. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. GI stay rod of 1800mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanized. GI stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanized. GI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments. Two nos of GI square washer of size 40x40x6mm to suit the 16mm dia GI rod. Two nos of GI hexagonal nut and bolt suitable for threaded portion of the stay rod mentioned above and conforming to IS-1365/67 with amendment No-1. All the GI materials shall conform to IS-226/75 with amendment No- 1 to 3 tested quality. The breaking load shall be 63KN min proof load (40% of breaking load shall be performed on all the stay sets. These figures have been taken from IS-16/74 with amendment No. Conforming to Drawing enclosed. Turn buckle with eye bolts for 11KV line & conforming to the following. One no of turn buckle made out of 16mm dia GI rod and 50x50x6mm M.S. angle galvanized. One eye bolt made out of 20mm dia GI rod with 40mm inner dia eye at one end threaded up to 300mm length from the other side. Two no’s GI nuts suitable for the threaded portion of eye bolt material specification IS-226/77 (tested quality) The breaking load and proof load shall be as per BS16/64 with amendment No-1. GI wire with tensile strength 32Kg/mm to 55Kg/mm soft quality 4.00mm dia 8SWG wire should conform to ISS-280/1972 and galvanized to heavy type as per ISS-4826/1968 with up to date amendments. The strain insulators shall be sound, free from defects, thoroughly vitrified & smoothly glazed & shall comply with the IS: 5300-1969 or the latest version thereof. The L.T. strain insulator shall have a minimum failing load of 44KN.
Supply of HDGI nuts and bolts 100 X 16 mm The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date. Bolts and nuts shall be supplied in bags of 25 kgs each. The testing of galvanization of bolts and nuts shall be carried out by the manufacturer and test reports shall be furnished before supply of materials. Department reserves the right to witness above testing.
Supply of Enamelled Danger boards for 11 KV The plate should be made from mild stel at least 1.6mm thick and vitereous enamelled white with letters,figures and covectional skull and bones in signal red color on the front side.The rear side of the plate shall be enamelled. All lettering should be centrally spaced. The corners of the plates should be rounded offsize"250mm x 200mm.
Supply of Anti climbing devices with clamps(barbed wire) Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date. Nominal diameter of line wire and point wire shall be 2.24mm each. Nominal distance between the two barbs shall be 150mm. The weight of each coil shall be 25 to 35 kg exclusive of weight of the reel. Tests as per IS shall be carried out at the manufacturer’s work & test reports shall be furnished before supply of materials. The department reserves the right to witness all the above tests.
Supply of H.D.G.I. DP Structure materials M.S. Angle of size 50 x 50 x 6 mm of minimum tensile strength 410 MPa conforming to IS 2062 as amended upto date. The sectional weight of steel shall be 4.5kg/m. The length of each piece shall be 4.5m to 6m. The rolling and cutting tolerances for weight and dimensions of steel shall be as per IS 1852-1985. Tests as per IS shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests. M.S. Channel 100 X 50 MM ISMC of minimum tensile strength 410 MPa conforming to IS 2062 as amended up to date. The sectional weight of steel shall be 9.2kg/m for M.S. Channel 100x50x6 MM ISMC. The sectional weight of steel shall be 7.14kg/m for M.S. Channel 75x40x6 MM ISMC The length of each piece shall be 4.5m to 6m. The rolling and cutting tolerances for weight and dimensions of steel shall be as per IS 1852-1985. Tests as per IS shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.
Supply of LA stay clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.
Supply of SA X arm clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.
Supply of LA X arm clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.
Supply of11 KV GOAB switch 200A 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The AB switches shall be of 200 A current rating:
Supply of ACSR Weasel conductor for earthing & jumpering Includes spreading of ACSR conductor without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points etc. The ground & line clearances at road crossings, along roads, Crossings & other crossings shall be as the relevant I.E. Rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall include cost of tree cutting as well.
Supply of HG fuse unit 11 KV 200A 11 KV H. G. fuse unit detailed specifications enclosed herewith Routine tests and acceptance for post insulators as per IS-2544-1973 as amended upto date and shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.
Supply of 9 KV 5 KA lightening arrestors 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm. The marking of the Lightning Arrestors shall be as per IS The Acceptance tests and routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.
Supply of Distribution Box(MS) with 200A MCCB & kit kat fuses The MS distribution box shall be designed as per the general specifications . The same shall be manufactured and supplied only after the Executive Engineer has approved the design and after the Executive Engineer accepts sample. After acceptance of the sample the Distribution box shall be supplied & erected. The distribution box should be mounted vertically on the ground with proper foundation. The rate specified is inclusive of foundation work, etc. The Distribution box shall be provided with two doors & MCCB of 400A capacity and Kit Kat fuses with 200A ratings shall be provided. A separate compartment with a separate door with sealing arrangement, exclusively for energy meter shall be provided.
Supply of DTC metering unit
Supply of 3 1/2 core XLPE Armoured cable 120sq.mm.1.1KV grade
Supply of 3 1/2 core XLPE Armoured cable 95sq.mm.1.1KV grade
Supply of Alluminium crimp lugs 120 sq. mm.
Supply of Alluminium crimp lugs 95 sq. mm.
Supply of Alluminium crimp lugs 70 sq. mm.(fror Earthing and Jumpering )
Supply of AA conductor ANT Includes spreading of AAC Conductors without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points, guard loops.. etc. The ground & line clearances at road crossings, along roads, L.T. crossings & other crossings shall be as the relevant I.E. rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall in¬clude cost of tree cutting as well. AAC Ant conductor for phases.
Supply of AA conductor GNAT Includes spreading of AAC Conductors without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points, guard loops.. etc. The ground & line clearances at road crossings, along roads, L.T. crossings & other crossings shall be as the relevant I.E. rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall in¬clude cost of tree cutting as well. GNAT conductor for double neutral, & guard loops.
Supply of LT 4 Pin cross arm channel type The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts
Supply of LT 2 Pin cross arm channel type The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts
Supply of SA X arm clamps for 7.5mt RCC pole Cross arms shall be made of HDGI channel of size ISMC 75X40X7.3mm. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified in the drawing. The cross arms shall be fitted horizontally on to the top end of the poles at a height conforming to the relevant I.E. Rules and utilizing suitable size of HDGI clamps, HDGI Nut & Bolts.The length of cut point cross arm should be 1.3 mtrs & guard cross arm should be 1.5 mtrs. The length of cut point cross arm should be 0.7mtrs.
Supply of LA X arm clamps for 7.5mt RCC pole Cross arms shall be made of HDGI channel of size ISMC 75X40X7.3mm. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place . The cross arms shall be fitted horizontally on to the top end of the poles at a height conforming to the relevant I.E. Rules and utilizing suitable size of HDGI clamps, HDGI Nut & Bolts.The length of cut point cross arm should be 1.3 mtrs & guard cross arm should be 1.5 mtrs. The length of cut point cross arm should be 0.7mtrs.
Supply of LT Pin insulator with GI Pin The pin insulators shall be of sound, free from defects, thoroughly vitrified & smoothly glazed of brown color except for the screw threads & the parts on which the porcelain is supported. The insulator shall be in one piece. The pin insulator shall have a top groove & shall be threaded to take mild steel pins & shall conform to IS: 1445-1977. The pin shall be suitable for the minimum failing load of 3.5KN. The insula¬tor shall comply to the tests as per IS: 1445. The fittings shall be conf to IS: 7935-1975 or the latest version thereof . The ferrous pin, nuts & washers except those made of stainless steel shall be hot dipped galvanized. The threads of nuts shall be cut after galvanizing & shall be well oiled & greased. The pin shall have a stalk length of 135mm, shank length of 125mm & minimum failing load of 2.0 KN,.
Supply of LT Shackle insulator with metal parts The L.T. Shackle insulators shall be of brown glazed of size 100x115 mm generally conforming to type 2 figures 4 of IS/445/1966 with amendment no. 1 and as amended upto date & also with IS: 1445/1977 or as amended upto date. The fittings shall be conforming to IS: 7935-1975 or the latest version thereof. The same shall be suitable of a normal system voltage of 440volts with tolerance limits of +-5%. The shackle insulator shall be suitable for the minimum failing load of 16.0 KN. The insulator shall comply to the tests as per IS: 1445. All ferrous fittings & parts other than that of stainless steel shall be hot dipped galvan¬ized. The Strip type fittings shall consists of a pair of M.S. straps, 2 nos. M.S. Bolts with hexagonal head & nuts, 2 nos. spring washers & helically formed conductor dead-end fittings made of aluminum alloy or aluminum-clad steel conforming to the relevant IS specifications
Supply of FRP fencing complete with gateas per specification for distribution transformer (size 4Mx3Mx2M) with concreting for FRP fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. each ratio 1:3:6
Supply of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable
Supply of 11KV, 3 core 185sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable
Supply of 3 WAY RMU ,11KV, 630 Amps,21 kA, 3 sec, SF6 Outdoor RMU- 2 LBS+ 1 CB Extension/Non-Extendable Two (2) Motor operated load break switches (LBSs) with manual operated earthing switches inSF6 and one (1) vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing switches SCADA compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS module (N-1) but not less than 1 no's per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet switch/LIU along with battery, battery charger shall be provided in RMU.
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side.
Supply of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting 11KV end of Distribution transformer .
Supply of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section.
Supply of Straight through joint complete for 11 KV XLPE cable of size 3 x 300sq.mm
Supply of RCC Cable route Markers (400 x 900 x 100 mm)
Supply of Warning tape for entire 11 KV route length.
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing , complete a) Sand
Supply of Vibro press RCC protective covers of size 480mm long x 250mm width and 50 mm thick capable of bearing load of 135 Kg. And covered with earth/sand upto depth of 0.15 mts. Conforming to IS 1255-1967 at non-road crossing
Supply of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's.
Supply of HDGI flat of size 25mm x 5mm for earthing of RMU's
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations of RMU's)
Supply & providing of Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete for RMU's
Supply & providing of 12 mm cement plaster 1:4 ( 1 cement: 4 fine sand) for foundations of RMU's
Supply of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.
Supply of GI pipe,100mm dia, Class B for bridge crossing.
Supply & fixing of Modem for Automatic meter reading
Erection Cost
Erection of RCC pole 9mtrs long 9meters long R.C.C. Pole conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date. Ordinary Port land cement 53 grade IS 12269 Aggregate IS 383-1970 Torsteel IS 1786-7985 MS bar IS 432 P 1&2-1982 The minimum ultimate transverse load of pole shall be 300Kg for 9mtr. RCC Pole respectively and factor of safety shall be 2.5. The pole shall be marked as per IS. The poles shall be tested as per IS 785 & 2905-1989 as amended upto date at the manufactures works in the presence of the departmental representative and test reports shall be furnished for acceptance. The poles will be accepted subject to passing of tests and verification of reinforcement and concrete after breaking one pole from each lot at cost of the manufacturer.
Erection of RCC pole 7.5mtrs long 7.5meters long R.C.C. Pole conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date. Ordinary Port land cement 53 grade IS 12269 Aggregate IS 383-1970 Torsteel IS 1786-7985 MS bar IS 432 P 1&2-1982 The minimum ultimate transverse load of pole shall be 250Kgs for 7.5mtr. RCC Pole respectively and factor of safety shall be 2.5. The pole shall be marked as per IS. The poles shall be tested as per IS 785 & 2905-1989 as amended upto date at the manufactures works in the presence of the departmental representative and test reports shall be furnished for acceptance. The poles will be accepted subject to passing of tests and verification of reinforcement and concrete after breaking one pole from each lot at cost of the manufacturer.
Providing Stay sets complete for 9 mtr RCC pole HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, break insulator of 15KV/8KV, HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. GI stay rod of 1800mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanized. GI stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanized. GI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments. Two nos of GI square washer of size 40x40x6mm to suit the 16mm dia GI rod. Two nos of GI hexagonal nut and bolt suitable for threaded portion of the stay rod mentioned above and conforming to IS-1365/67 with amendment No-1. All the GI materials shall conform to IS-226/75 with amendment No- 1 to 3 tested quality. The breaking load shall be 63KN min proof load (40% of breaking load shall be performed on all the stay sets. These figures have been taken from IS-16/74 with amendment No. . Turn buckle with eye bolts for 11KV line & conforming to the following. One no of turn buckle made out of 16mm dia GI rod and 50x50x6mm M.S. angle galvanized. One eye bolt made out of 20mm dia GI rod with 40mm inner dia eye at one end threaded up to 300mm length from the other side. Two no’s GI nuts suitable for the threaded portion of eye bolt material specification IS-226/77 (tested quality) The breaking load and proof load shall be as per BS16/64 with amendment No-1. GI wire with tensile strength 32Kg/mm to 55Kg/mm soft quality 4.00mm dia 8SWG wire should conform to ISS-280/1972 and galvanized to heavy type as per ISS-4826/1968 with up to date amendments. The strain insulators shall be sound, free from defects, thoroughly vitrified & smoothly glazed & shall comply with the IS: 5300-1969 or the latest version thereof. The L.T. strain insulator shall have a minimum failing load of 44KN.
Providing Stay sets complete for 7.5 mtr RCC pole HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, break insulator of 15KV/8KV, HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. GI stay rod of 1800mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanized. GI stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanized. GI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments. Two nos of GI square washer of size 40x40x6mm to suit the 16mm dia GI rod. Two nos of GI hexagonal nut and bolt suitable for threaded portion of the stay rod mentioned above and conforming to IS-1365/67 with amendment No-1. All the GI materials shall conform to IS-226/75 with amendment No- 1 to 3 tested quality. The breaking load shall be 63KN min proof load (40% of breaking load shall be performed on all the stay sets. These figures have been taken from IS-16/74 with amendment No.. Turn buckle with eye bolts for 11KV line & conforming to the following. One no of turn buckle made out of 16mm dia GI rod and 50x50x6mm M.S. angle galvanized. One eye bolt made out of 20mm dia GI rod with 40mm inner dia eye at one end threaded up to 300mm length from the other side. Two no’s GI nuts suitable for the threaded portion of eye bolt material specification IS-226/77 (tested quality) The breaking load and proof load shall be as per BS16/64 with amendment No-1. GI wire with tensile strength 32Kg/mm to 55Kg/mm soft quality 4.00mm dia 8SWG wire should conform to ISS-280/1972 and galvanized to heavy type as per ISS-4826/1968 with up to date amendments. The strain insulators shall be sound, free from defects, thoroughly vitrified & smoothly glazed & shall comply with the IS: 5300-1969 or the latest version thereof. The L.T. strain insulator shall have a minimum failing load of 44KN.
Fixing of HDGI nuts and bolts 100 X 16 mm The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date. Bolts and nuts shall be supplied in bags of 25 kgs each. The testing of galvanization of bolts and nuts shall be carried out by the manufacturer and test reports shall be furnished before supply of materials. Department reserves the right to witness above testing.
Providing Enamelled Danger boards for 11 KV The plate should be made from mild stel at least 1.6mm thick and vitereous enamelled white with letters,figures and covectional skull and bones in signal red color on the front side.The rear side of the plate shall be enamelled. All lettering should be centrally spaced. The corners of the plates should be rounded offsize"250mm x 200mm.
Providing Anti climbing devices with clamps(barbed wire) Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date. Nominal diameter of line wire and point wire shall be 2.24mm each. Nominal distance between the two barbs shall be 150mm. The weight of each coil shall be 25 to 35 kg exclusive of weight of the reel. Tests as per IS shall be carried out at the manufacturer’s work & test reports shall be furnished before supply of materials. The department reserves the right to witness all the above tests.
Fixing of H.D.G.I. DP Structure materials M.S. Angle of size 50 x 50 x 6 mm of minimum tensile strength 410 MPa conforming to IS 2062 as amended upto date. The sectional weight of steel shall be 4.5kg/m. The length of each piece shall be 4.5m to 6m. The rolling and cutting tolerances for weight and dimensions of steel shall be as per IS 1852-1985. Tests as per IS shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests. M.S. Channel 100 X 50 MM ISMC of minimum tensile strength 410 MPa conforming to IS 2062 as amended up to date. The sectional weight of steel shall be 9.2kg/m for M.S. Channel 100x50x6 MM ISMC. The sectional weight of steel shall be 7.14kg/m for M.S. Channel 75x40x6 MM ISMC The length of each piece shall be 4.5m to 6m. The rolling and cutting tolerances for weight and dimensions of steel shall be as per IS 1852-1985. Tests as per IS shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.
Fixing of LA stay clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.
Fixing of SA X arm clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.
Fixing of LA X arm clamps for 9mt RCC pole All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72 & shall be conforming to the drawings and should be fitted with nut bolts.
Erection of11 KV GOAB switch 200A 12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy. The AB switches shall be of 200 A current rating:
Stringing of ACSR Weasel conductor for earthing & jumpering Includes spreading of ACSR conductor without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points etc. The ground & line clearances at road crossings, along roads, Crossings & other crossings shall be as the relevant I.E. Rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall include cost of tree cutting as well.
Erection of HG fuse unit 11 KV 200A 11 KV H. G. fuse unit detailed specifications enclosed herewith Routine tests and acceptance for post insulators as per IS-2544-1973 as amended upto date and shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.
Fixing of 9 KV 5 KA lightening arrestors 9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm. The marking of the Lightning Arrestors shall be as per IS The Acceptance tests and routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials. The Department reserves the right to witness all the above tests.
Fixing of Distribution Box(MS) with 200A MCCB & kit kat fuses The MS distribution box shall be designed as per the general specifications. The same shall be manufactured and supplied only after the Executive Engineer has approved the design and after the Executive Engineer accepts sample. After acceptance of the sample the Distribution box shall be supplied & erected. The distribution box should be mounted vertically on the ground with proper foundation. The rate specified is inclusive of foundation work, etc. The Distribution box shall be provided with two doors & MCCB of 400A capacity and Kit Kat fuses with 200A ratings shall be provided. A separate compartment with a separate door with sealing arrangement, exclusively for energy meter shall be provided.
Fixing of DTC metering unit
Fixing CCMS Panel for street light 3 phase
Laying of 3 1/2 core XLPE Armoured cable 120sq.mm.1.1KV grade
Laying of 3 1/2 core XLPE Armoured cable 95sq.mm.1.1KV grade
Erection of 100 KVA, Distribution transformer All bolts, studs, screw threads, pipe threads, bolt heads and nuts shall comply with the appropriate Indian Standards for metric threads, or the technical equivalent. Bolts or studs shall not be less than 6 mm in diameter except when used for small wiring terminals. All nuts and pins shall be adequately locked. Wherever possible bolts shall be fitted in such a manner that in the event of failure of locking resulting in the nuts working loose and falling off, the bolt will remain in position. All ferrous bolts, nuts and washers placed in outdoor positions shall be treated to prevent corrosion, by hot dip galvanising, except high tensile steel bolts and spring washers which shall be electro galvanised/ plated. Appropriate precautions shall be taken to prevent electrolytic action between dissimilar metals. Each bolt or stud shall project at least one thread but not more than three threads through the nut, except when otherwise approved for terminal board studs or relay stems. If bolts nuts are placed so that they are inaccessible by means of ordinary spanners, special spanners shall be provided. The length of the screwed portion of the bolts shall be such that no screw thread may form part of a shear plane between members. Taper washers shall be provided where necessary. Protective washers of suitable material shall be provided front and back or the securing screws.
Fixing of Alluminium crimp lugs 120 sq. mm.
Fixing of Alluminium crimp lugs 95 sq. mm.
Fixing of Alluminium crimp lugs 70 sq. mm.(fror Earthing and Jumpering )
Stringing of AA conductor ANT Includes spreading of AAC Conductors without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points, guard loops.. etc. The ground & line clearances at road crossings, along roads, L.T. crossings & other crossings shall be as the relevant I.E. rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall in¬clude cost of tree cutting as well. AAC Ant conductor for phases.
Stringing of AA conductor GNAT Includes spreading of AAC Conductors without any damage and stringing with proper tension without any kinks/damage including binding of conductor at pin points, jumpering at cut points, guard loops.. etc. The ground & line clearances at road crossings, along roads, L.T. crossings & other crossings shall be as the relevant I.E. rules. Tree cutting wherever required is to be carried out before stringing of the Conductor with prior permission of the Engineer in charge. The rates for Stringing of conductor in Schedule-II shall in¬clude cost of tree cutting as well. GNAT conductor for double neutral, & guard loops.
Fixing of LT 4 Pin cross arm channel type The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts
Fixing of LT 2 Pin cross arm channel type The cross arms shall be fitted vertically onto the top end of the poles, at a height conforming to the relevant I.E. rules & utilizing suitable size of HDGI clamps & HDGI washers, HDGI nut bolts
Fixing of SA X arm clamps for 7.5mt RCC pole Cross arms shall be made of HDGI channel of size ISMC 75X40X7.3mm. hot dip galvanizing generally conforming to IS – 2633/72. The cross arm shall not be welded/joined at any place except as specified in the drawing. The cross arms shall be fitted horizontally on to the top end of the poles at a height conforming to the relevant I.E. Rules and utilizing suitable size of HDGI clamps, HDGI Nut & Bolts.The length of cut point cross arm should be 1.3 mtrs & guard cross arm should be 1.5 mtrs. The length of cut point cross arm should be 0.7mtrs.
Fixing of LA X arm clamps for 7.5mt RCC pole Cross arms shall be made of HDGI channel of size ISMC 75X40X7.3mm. hot dip galvanizing generally conforming to IS – 2633/72. The cross arm shall not be welded/joined at any place except as specified in the drawing. The cross arms shall be fitted horizontally on to the top end of the poles at a height conforming to the relevant I.E. Rules and utilizing suitable size of HDGI clamps, HDGI Nut & Bolts.The length of cut point cross arm should be 1.3 mtrs & guard cross arm should be 1.5 mtrs. The length of cut point cross arm should be 0.7mtrs.
Fixing of LT Pin insulator with GI Pin The pin insulators shall be of sound, free from defects, thoroughly vitrified & smoothly glazed of brown color except for the screw threads & the parts on which the porcelain is supported. The insulator shall be in one piece. The pin insulator shall have a top groove & shall be threaded to take mild steel pins & shall conform to IS: 1445-1977. The pin shall be suitable for the minimum failing load of 3.5KN. The insula¬tor shall comply to the tests as per IS: 1445. The fittings shall be conf to IS: 7935-1975 or the latest version thereof & as per approved drawing. The ferrous pin, nuts & washers except those made of stainless steel shall be hot dipped galvanized. The threads of nuts shall be cut after galvanizing & shall be well oiled & greased. The pin shall have a stalk length of 135mm, shank length of 125mm & minimum failing load of 2.0 KN, .
Fixing of LT Shackle insulator with metal parts The L.T. Shackle insulators shall be of brown glazed of size 100x115 mm generally conforming to type 2 figures 4 of IS/445/1966 with amendment no. 1 and as amended upto date & also with IS: 1445/1977 or as amended upto date. The fittings shall be conforming to IS: 7935-1975 or the latest version thereof. The same shall be suitable of a normal system voltage of 440volts with tolerance limits of +-5%. The shackle insulator shall be suitable for the minimum failing load of 16.0 KN. The insulator shall comply to the tests as per IS: 1445. All ferrous fittings & parts other than that of stainless steel shall be hot dipped galvan¬ized. The Strip type fittings shall consists of a pair of M.S. straps, 2 nos. M.S. Bolts with hexagonal head & nuts, 2 nos. spring washers & helically formed conductor dead-end fittings made of aluminum alloy or aluminum-clad steel conforming to the relevant IS specifications
Providing of FRP fencing complete with gateas per specification for distribution transformer (size 4Mx3Mx2M) with concreting for FRP fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. each ratio 1:3:6
Removing of RCC pole 7.5 mts long
Removing of 4 PIN 'X' arm of 75x40 Channel
Removing of 2 PIN 'X' arm of 75x40 Channel
Removing of LT shackle insulator with metal parts
Removing of LT pin insulator with G.I Pin
Laying of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable
Laying of 11KV, 3 core 185sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable
Erection,testing & comissioning of 3 WAY RMU ,11KV, 630 Amps,21 kA, 3 sec, SF6 Outdoor RMU- 2 LBS+ 1 CB Extension/Non-Extendable Two (2) Motor operated load break switches (LBSs) with manual operated earthing switches inSF6 and one (1) vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing switches SCADA compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS module (N-1) but not less than 1 no's per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet switch/LIU along with battery, battery charger shall be provided in RMU.
Erection of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side.
Erection of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting 11KV end of Distribution transformer
Erection of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section.
Providing of Straight through joint complete for 11 KV XLPE cable of size 3 x 300sq.mm
Providing of RCC Cable route Markers (400 x 900 x 100 mm)
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/ LT cables of various sizes including excavation for equipment foundations i.e for RMU's including getting out the excavated soil and disposal of surplus excavated soil.
Refilling of excavated soil in the foundations, trenches etc. with available excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments.
Laying of Vibro press RCC protective covers of size 480mm long x 250mm width and 50 mm thick capable of bearing load of 135 Kg. And covered with earth/sand upto depth of 0.15 mts. Conforming to IS 1255-1967 at non-road crossing
Erection of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's.
Erection of HDGI flat of size 25mm x 5mm for earthing of RMU's
Laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.
Laying of GI pipe,100mm dia, Class B for bridge crossing.
Laterite Masonary Works Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. Double Circuit 11KV cable trench (0.2x0.9x1) i.e 0.18per RM (0.18x500mtr) 90 Cu.mts
Ground penetrating radar survey ( G.P.R ) a) Scanning the roads using ground penetrating radar at every 20 meters interval b) Identification of metallic and non metallic utilities such as water pipelines , ofc, gas lines and any other existing utilities along with depth.
stage.html
html • 0.03 MB
technical_28363.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 11.77 MB
Tendernotice_2.pdf
PDF • 20.44 MB
Tendernotice_3.pdf
PDF • 2.77 MB
BOQ_28363.xls
BOQ • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .