Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 0 | ₹20.3 L Quoted ₹21.0 L | L1 | Accepted-AOC Performance security Rs. 1,01,500.00 shall be submitted before 28 days from the acceptance of the contract as per Condition 19 of IAFW2249 otherwise necessary action will be taken against your firm |
| 2 | L2₹21.8 LRejected-Finance | ₹21.8 L | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹28.0 LRejected-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | SANT KABEER NAGAR | UTTAR PRADESH | 272125 | ₹28.0 L | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹28.1 LRejected-Finance 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | ₹28.1 L | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹30.4 LRejected-Finance 1 C 12 DAYAL REJENCY NEAR B B D COLLEGE LUCKNOW LUCKNOW UTTAR PRADESH 226028 | LUCKNOW | UTTAR PRADESH | 226028 | ₹30.4 L | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Ambrish Builders L2 | M/S R S Traders L5 | A S ENTERPRISES L1 | Krishna Enterprises L8 | Bharat Trading Company L3 | K R GUPTA AND SONS L7 | M/S vibhuti enterprises L4 | GN ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour for cutting/pruning of tree branches upto 3 inches dia along security light pole around 2 mtr radius of security light fitting and removing from site including arrangement of T&P (i.e Axe , rope & ladder etc), complete all as specified and directed. | 210 | Each Job | 50 ₹10,500 | 60 ₹12,600 | 40 ₹8,400 | 103 ₹21,630 | 50 ₹10,500 | 100 ₹21,000 | 10 ₹2,100 | 50 ₹10,500 |
| 2.00 | Dismantling and taking down street light fittings/ Post Top Lantern/ down lighter of any wattage/size for repair replacement of burnt/worn out accessories and carrying to MES store, complete all as directed by Engr-in-Charge.
Note:-(i) Accessories or components need for replacement shall be measured & paid separately under appropriate items. | 850 | Each Job | 60 ₹51,000 | 85 ₹72,250 | 1 ₹850 | 50 ₹42,500 | 20 ₹17,000 | 100 ₹85,000 | 50 ₹42,500 | 50 ₹42,500 |
| 3.00 | M&L for repairing of unserviceable LED street light any make /model of 90-100 watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection, complete all as specified and directed.
Driver make Phillips/ havells/wipro/CG/Bajaj as approved. | 300 | Each | 100 ₹30,000 | 225 ₹67,500 | 120 ₹36,000 | 250 ₹75,000 | 200 ₹60,000 | 440 ₹1,32,000 | 200 ₹60,000 | 180 ₹54,000 |
| 4.00 | M&L for repairing of unserviceable LED street light any make /model of 60-72 watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection, complete all as specified and directed.
Driver make Phillips/ havells/wipro/CG/Bajaj as approved. | 300 | Each | 100 ₹30,000 | 225 ₹67,500 | 120 ₹36,000 | 250 ₹75,000 | 200 ₹60,000 | 330 ₹99,000 | 200 ₹60,000 | 160 ₹48,000 |
| 5.00 | M&L for repairing of unserviceable LED street light any make /model of 40-50 watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection, complete all as specified and directed.
Driver make Phillips/ havells/wipro/CG/Bajaj as approved.
Note for item No 03 to 05
(i) Make of item No. 03 to 05 : Philips/Bajaj/Crompton/Havells
(ii) contractor will mark a identity (i.e CA No . or Firm Name) ,using permanent paint marker pen on each component which will be replaced under repair of street light and he will be liable to change his new replaced items without any extra cost which become unserviceable due to any reason, during execution period of CA and further upto defect liability period.
(iii) It will be contractor responsibility to take the location of unvs street/garden/post top/ search light fittings by MES rep at 9 AM at AGE E/M office on every working day. | 250 | Each | 100 ₹25,000 | 225 ₹56,250 | 120 ₹30,000 | 200 ₹50,000 | 200 ₹50,000 | 240 ₹60,000 | 200 ₹50,000 | 150 ₹37,500 |
| 6.00 | M& L for repairing of unserviceable Gate light of any type/make by replacing burn out/worn-out/ weak LED lamp 25 watt and re- fixing the fitting in position after repair and testing, complete all as specified and directed.
Make: Phillips/Bajaj/Havells/CG as approved. | 60 | Each | 75 ₹4,500 | 135 ₹8,100 | 100 ₹6,000 | 150 ₹9,000 | 200 ₹12,000 | 450 ₹27,000 | 300 ₹18,000 | 150 ₹9,000 |
| 7.00 | M& L for repairing of unserviceable Garden/Gate light of any type/make by replacing burn out/worn-out/ weak Normal LED lamp 9/11 watt and re- fixing the fitting in position after repair and testing, complete all as specified and directed.
Make: Phillips/Bajaj/Havells/CG as approved. | 150 | Each | 50 ₹7,500 | 135 ₹20,250 | 100 ₹15,000 | 97 ₹14,550 | 120 ₹18,000 | 140 ₹21,000 | 50 ₹7,500 | 100 ₹15,000 |
| 8.00 | M& L for repairing of unserviceable Garden/Gate light of any type/make by replacing burn out/worn-out/ weak Normal LED lamp 05/07 watt and re- fixing the fitting in position after repair and testing, complete all as specified and directed.
Make: Phillips/Bajaj/Havells/CG as approved. | 200 | Each | 40 ₹8,000 | 135 ₹27,000 | 80 ₹16,000 | 93 ₹18,600 | 120 ₹24,000 | 130 ₹26,000 | 50 ₹10,000 | 100 ₹20,000 |
| 9.00 | S&F of rigid PVC conduit 'medium grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole/ garden lights/ Gate lights for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp, nut bolt, complete all as specified and directed. | 100 | RM | 25 ₹2,500 | 15 ₹1,500 | 22 ₹2,200 | 30 ₹3,000 | 40 ₹4,000 | 22 ₹2,200 | 25 ₹2,500 | 35 ₹3,500 |
| 10.00 | S&F of flexible PVC conduit 'light grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole/ garden lights/ Gate lights for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp, nut bolt and complete all as specified and directed. | 120 | RM | 25 ₹3,000 | 15 ₹1,800 | 22 ₹2,640 | 33 ₹3,960 | 30 ₹3,600 | 20 ₹2,400 | 25 ₹3,000 | 35 ₹4,200 |
Tender Value
₹40.6 L
EMD Value
₹81,500
Closing Date
14 Mar 2026, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
ROUTINE MAINT OF STREET LIGHT GARDEN LIGHTS GATE LIGHTS ETC AND ITS ALLIED WORKS AT AF STN BAMRAULI UNDER GE AF BAMRAULI
2026_MES_753900_1
9029/E8
Open Tender
Civil Works - Others
180 days
GE (AF) Bamrauli
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Bamrauli
₹81,500
Yes
23 Mar 2026
23 Feb 2026
16 Mar 2026
23 Feb 2026
14 Mar 2026
9 Mar 2026
Labour for cutting/pruning of tree branches upto 3 inches dia along security light pole around 2 mtr radius of security light fitting and removing from site including arrangement of T&P (i.e Axe , rope & ladder etc), complete all as specified and directed.
Dismantling and taking down street light fittings/ Post Top Lantern/ down lighter of any wattage/size for repair replacement of burnt/worn out accessories and carrying to MES store, complete all as directed by Engr-in-Charge. Note:-(i) Accessories or components need for replacement shall be measured & paid separately under appropriate items.
M&L for repairing of unserviceable LED street light any make /model of 90-100 watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection, complete all as specified and directed. Driver make Phillips/ havells/wipro/CG/Bajaj as approved.
M&L for repairing of unserviceable LED street light any make /model of 60-72 watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection, complete all as specified and directed. Driver make Phillips/ havells/wipro/CG/Bajaj as approved.
M&L for repairing of unserviceable LED street light any make /model of 40-50 watt capacity by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection, complete all as specified and directed. Driver make Phillips/ havells/wipro/CG/Bajaj as approved. Note for item No 03 to 05 (i) Make of item No. 03 to 05 : Philips/Bajaj/Crompton/Havells (ii) contractor will mark a identity (i.e CA No . or Firm Name) ,using permanent paint marker pen on each component which will be replaced under repair of street light and he will be liable to change his new replaced items without any extra cost which become unserviceable due to any reason, during execution period of CA and further upto defect liability period. (iii) It will be contractor responsibility to take the location of unvs street/garden/post top/ search light fittings by MES rep at 9 AM at AGE E/M office on every working day.
M& L for repairing of unserviceable Gate light of any type/make by replacing burn out/worn-out/ weak LED lamp 25 watt and re- fixing the fitting in position after repair and testing, complete all as specified and directed. Make: Phillips/Bajaj/Havells/CG as approved.
M& L for repairing of unserviceable Garden/Gate light of any type/make by replacing burn out/worn-out/ weak Normal LED lamp 9/11 watt and re- fixing the fitting in position after repair and testing, complete all as specified and directed. Make: Phillips/Bajaj/Havells/CG as approved.
M& L for repairing of unserviceable Garden/Gate light of any type/make by replacing burn out/worn-out/ weak Normal LED lamp 05/07 watt and re- fixing the fitting in position after repair and testing, complete all as specified and directed. Make: Phillips/Bajaj/Havells/CG as approved.
S&F of rigid PVC conduit 'medium grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole/ garden lights/ Gate lights for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp, nut bolt, complete all as specified and directed.
S&F of flexible PVC conduit 'light grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole/ garden lights/ Gate lights for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp, nut bolt and complete all as specified and directed.
M&L for replacement of Lamp holder of post top lantern fitting/decorative fitting/PTL, complete all as directed by engr-in-Charge.
S&F of switch socket outlet multipurpose type of 6 pin, 16 amp flush type, complete all as specified & directed.
S&F in repair pressed steel terminal boxes made out of 1.2mm thick mild steel sheet, 200mm x 150mm x 60 mm deep including cutting on sheet and fixing existing switches, sockets alongwith 03 mm thick plastic laminated sheet cover, fitted with cadmium plated screw washer and cutting/chasing as required in brick wall to recess the same including making good to disturbed surface with cement mortar ratio 1:4 and treated the surface with existing white/colour wash/distemper etc to match with existing surface, complete all as specified and directed.
S&F in replacement of PVC insulated PVC sheathed stranded copper conductor cable 2.5 Sqmm twin core, complete all as specified and directed.
S&F in replacement of Pole box three phase of size 205 x 255 x 112 mm made out of 2 mm PVC factory made with inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fixe on epoxy insulated pole and MCB 6 Amp 10 kA 240 volt, complete all as specified and directed.
Supply & fixing of PVC insulation tape of width - 18 mm, thickness - 0.125 mm in length of 25 mtr, ISI marked for proper insulation of joints in wire where as required or directed, complete all as specified and directed.
Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying in repair/replacement of cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing, complete all as directed for following size :-
4 Sqmm 2 core
6 Sqmm 2 core
10 Sqmm 2 core
Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying in repair/replacement of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing, complete all as directed for following size :-
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core [Note for item No.17 & 18 :-Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately]
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for electric cable complete in any type of soil, complete all as specified and directed. Note :-For the digging of soil , JCB machine will not be allow at site, it will be done by labour only and contractor will be responsibleto repair the existing cable , pcc plinth etc without extra cost which will be damaged during execution of work.
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point, complete all as specified and directed.
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed.
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable, complete all as specified and directed.
M & L for sand cushioning with Ganga Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable, complete all as specified and directed.
M&L for boring under road horizontely of size 40/50 mm bore using GI pipe for passing of cable in road/path in hard/soft/ loose soil, complete all as specified and directed.
M&L in replacement of following GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor / as garden post including 2 Nos mild steel FI clamps 35x3 mm size to support pipe with pole, complete all as specified and directed.
40 mm bore size
50 mm bore size
M & L for applying two coats of aluminium paint over a coat of red oxide on Steel tubular pole upto 11 mtr including cross arms and clamps except embedded portion of pole in ground and concrete after removing old painted surfaces by scraping of poles complete and making colour band with synthetic enamel paint of approved colour up to 1.2 mtr from coping level including numbering of poles in 150 mm dia of approved colour paint complete all as specified and directed .
Taking down (from High Mast) of single phase electric operated search light motor of capacity 2 HP , dismantling & Rewinding with existing gauge size copper wire and as existing Nos of turns of coils for maintaining existing capacity of the motor and varnishing ,drying incl re fixing & testing for proper rotation of search light fitting at watch tower, complete all as specified and directed.
S&F in replacement of following items in the existing panels and connection with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection, complete all as specified and directed as below. (Note :-Make of TPN MCB : Schneider/L&T/ABB/Legrand)
MCB TPN, 32 Amps, 415 Volt, 'C' series, 10 kA
MCB TPN, 63 Amps, 415 Volt, 'C' series, 10 kA
MCB SPN, 06-32 Amps, 240 Volt, 'C' series, 10 kA
MCB SPN, 63 Amps, 240 Volt, 'C' series, 10 kA
S&F in replacement of interal LED Aviation light comprising of aluminium housing with polycorbonate enclosure including provision of three core copper cable conductor of size 2.5 Sqmm 3 core of white covering for making connection, fixing the fitting on wall including all necessary fixing accessories, complete all as directed and specified by Engr- in-Charge.
S&F in replacement of new generation,post top, energy saving,environment friendly, long life aesthetically designed with good indirect symmetrical light distribution, die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser IP65 protection luminaire with high power LEDs as light source of 26 watt, colour temp 4000 K as light source including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm, complete all as specified & directed. Make- Philips, Cat Part No. BGP200 LED26 CW PSU GR SPD or equivalent in Philips/Havells/CG as approved.
S&F in replacement of new generation,post top, energy saving,environment friendly, long life aesthetically designed with good symmetrical light distribution, spherical shape polycarbonate opal and clear diffuser with high power LEDs as light source of 35 Watt, color Temp- 5700 K & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm, complete all as specified & directed. Make-Philips Cat Part No. BGP200 LED35 CW PSU GR SPD or equivalent in Havells/Crompton/Bajaj as approved.
S&F in replacement of new generation,post top, energy saving,environment friendly, long life aesthetically designed with good indirect symmetrical light distribution, die-cast aluminium bottom housing and spun aluminium powder coated housing with higher eiciency lighting IP65 protection luminaire with high power LEDs as light source of 45 watt, colour temp 6000 K as light source including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed (Make- Philips, Cat Part No. BGP200 LED45 CW PSU GR SPD or equivalent in Philips/Havells/CG as approved.
Supply and fixing in replacement of LED streetlight fitting of 60 Watt high pressure die cast aluminium housing, with minimum 140 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting, complete all as specified and directed. Cat Part No: BRP501 LED084 CW R3C PSU S1 of Philips or its equivalent in Havells/ CG/ Bajaj as approved.
Supply and fixing in replacement of LED streetlight fitting of 70 Watt high pressure die cast aluminium housing, with minimum 140 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting, complete all as specified and directed. Cat Part No: BRP501 LED098 CW R3C PSU S1 of Philips or its equivalent in Havells/ CG/ Bajaj as approved.
Supply and fixing in replacement of LED streetlight fitting of 90 Watt high pressure die cast aluminium housing, with minimum 140 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting, complete all as specified and directed. Cat Part No: BRP502 LED126 CW R3C PSU S1 of Philips or its equivalent in Havells/ CG/ Bajaj as approved.
Supply and fixing in replacement of LED Flood light fitting of 100 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant polycorbonatye glass (IP 66 protection), high impact resistance(IK07) with Surge protection level until 4 kV, color temp 5700 K, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting, complete all as specified and directed. Part No: BVP281 LED085 CW FG SY5NB 100W V1 of Philips or its equivalent in Havells/ CG/ Bajaj as approved.
Supply and fixing in replacement of LED Flood light fitting of 150 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant polycorbonatye glass (IP 66 protection), high impact resistance(IK07) with Surge protection level until 4 kV, color temp 5700 K, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting, complete all as specified and directed. Part No: BVP282 LED181 CW FG SY5WB 150W V1 of Philips or its equivalent in Havells/ CG/ Bajaj as approved.
Supply and fixing in replacement of LED Flood light fitting of 200 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant polycorbonatye glass (IP 66 protection), high impact resistance(IK07) with Surge protection level until 4 kV, color temp 5700 K, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting, complete all as specified and directed. Part No: BVP283 LED240 CW FG SY5WB 200W V1 of Philips or its equivalent in Havells/ CG/ Bajaj as approved.
Supply and fixing in replacement of LED Flood light fitting of 250 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant polycorbonatye glass (IP 66 protection), high impact resistance(IK07) with Surge protection level until 4 kV, color temp 5700 K, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting, complete all as specified and directed. Part No: BVP283 LED240 CW FG SY5WB 200W V1 of Philips or its equivalent in Havells/ CG/ Bajaj as approved.
S&F in replacement of new generation, LED Bollard in cylinderical shape, energy saving, environment friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LEDs as light source & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm, complete all as specified & directed. Make-Philips, Cat Part No.BCP150 LED150/WW PSU 220-240V 7043 (1.0 M) or equivalent in Havells/CG/Bajaj as approved.
S& F in replacement of LED 12 Watt round panel light with dust Proof IP 50 Energy saving warm white LED panel ceiling light, aluminium metal powder coated, surface mounted LED light with driver and light prevent damage from dust, dirt, corrosion, and other factors all as specified and directed (Make-Philips, Cat Part No. SM296C LED15S-6500 PSU WH or equivalent in Havells/CG/Bajaj etc.
S& F in replacement of LED 15 Watt round panel light with dust Proof IP 50 Energy saving warm white LED panel ceiling light, aluminium metal powder coated, surface mounted LED light with driver and light prevent damage from dust, dirt, corrosion, and other factors, complete all as specified and directed. Make-Philips, Cat Part No. SM296C LED20S-6500 PSU WH or equivalent in Havells/CG/Bajaj etc.
S&F in replacement of bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
S&F in replacement of MS bracket for mounting flood light fitting made out of MS angle iron of size 40x40x6 mm of length not less than 1.0 mtr, fixed to pole/ earth and grout using PCC & clamp, nut & bolts including painting of bracket with one coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
S&F in replacement of Contactor suitable for street light timer panel any type of following size. (Make- L&T or equivalent as approved) in existing panel/ location and connection incl necessary alteration in panel/ door as required for proper fixing & connection, complete all as specified and directed.
S&F in replacement of Flexible LED strip 25W, IP 68 WW uses high brightness, transparent,Heat resistant, water proof, anti dust with PVC covering duly visible in dark from far off distance fitted with suitable connectors for inter connection along with driver complete all, plug and socket arrangement suitable to be fitted on edges of buildings, pathways and outer periphery of boundary walls Main gates, Hard standings etc complete with clamping at suitable distance to take the shape of required physical structure of Warm white/Dark blue, complete all as specified and directed. Part No: BGC301 1200LM 5000K L5000 of Philips or its equivalent in Havells/ CG/ Bajaj or as approved. Note : Contractor Shall ensure proper power supply should be 'OFF' at working area. Any type of accident should not be accepted in any consition.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
Tender.pdf
Tender Documents • 1.43 MB
BOQ_844410.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid