Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.3 L+₹1.2 L (3.72%)Rejected-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L2 | Rejected-AOC L2 | |
| 3 | L3₹34.5 L+₹2.5 L (7.68%)Rejected-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L3 | Rejected-AOC L3 | |
| 4 | L4₹34.6 L+₹2.5 L (7.90%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹35.4 L+₹3.3 L (10.3%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹40.9 L
EMD Value
₹81,720
Closing Date
23 Oct 2024, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
SPECIAL REPAIRS/ REPLACEMENT OF EXISTING ALUMINIUM WIRING TO COPPER WIRING AT VARIOUS TECH HANGAR AT AFS YELAHANKA
2024_MES_676640_1
8292/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹81,720
Yes
7 Dec 2024
25 Sept 2024
30 Oct 2024
25 Sept 2024
23 Oct 2024
9 Oct 2024
Amount
Taking down the unserviceable aluminium point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, switch sockets combination, ceiling roses, pendent regulators, bell bush, calling bell etc and making good distrubed surfaces of walls and floors etc. all as directed.
Taking down existing old unserviceable submain wiring removing materials for keeping in safe custody and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) single core PVC insulated heavy duty ISI Marked FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through in and including non metallic rigid PVC conduit of suitable size dia and conduit accessories concelaed/ fixed to wall/floors/ceiling etc and provision of PVC Insulated heavy duty ISI marked FRLS unsheathed copper conductor,1.5 sqmm for earth continuity conductor and connected to common earth dolly including cutting chases for conduits and sinking's for boxes and making good to walls, floors etc suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlests, fan regulators including fixing PVC round block etc., complete all as specified and directed for the following: -
One light point controlled by one 5 Amps switch.
One ceiling fan/Exhaust fan controlled by one 5 Amps switch.
One socket 5 amp on independent board.
All as per item No 3 above but wiring with 2.5 sq mm FRLS copper cable including earth continuty conductor with 2.5 sq mm FRLS copper cable for one 6 pin 15 Amps socket outlet on independent board controlled by 15 Amps switch all as specified and directed.
S&F in repair switch piano 5 Amps flush type one way all as specified and directed.
S&F in repair switch socket combination 2 in 1, 5 Amps piano flush type all as specified and directed.
S&F in repair switch socket combination 5/15 Amps multi pin flush type all as specified and directed.
S&F in repair ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete all as specified and directed.
S&F in repair fan speed regulator, electronic step type, suitable for single phase AC, 240 volts, 50 Hz, 100 watts all as specified and as directed.
M&L for sub-main wiring 2x2.5 sq. mm +1x2.5 sq. mm earth wire unsheathed PVC insulated, single core cable with copper stranded conductor drawn through and including suitable dia non metallic rigid PVC white conduit and conduit accesories concealed/fixed to wall/Hangar&building roof/floor as per site requirement complete all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length.
M&L for sub-main wiring with two runs of 4 sqmm unsheathed PVC insulated, single core cable with copper stranded conductor drawn through and including suitable dia non metallic rigid PVC white conduit and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 4 sqmm copper earth wire complete all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length. Three run of 4 Sq mm cable and PVC conduct is measured as one Run or one Meter.
M & L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10 cm girth all as directed.
S&F in repair building security light LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection complete all as specified and directed.
S&F in repairs LED Tube light dual colour(warm & bright) fitting 1 x20 W, 4 feet ,220V housing with PC diffuser box type with driver,holder including LED tube light connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed.
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down existing ceiling fan of any size, M&L machine Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. Including writing MES No, complete all as specified and directed.
Hanging Only Ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost Complete all as specified and as directed.
Taking down existing exhaust fan 300 mm sweep, M&L machine Painting of Exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. Including writing MES No, complete all as specified and directed.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan all as specified and directed.
S&F in repair sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 2 way single door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed.
S&F in repair sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed.
S&F in repair sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 8 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed.
S&F in repair sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 12 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed.
S&F in repair sheet metal enclosures for MCB distribution board 415 Volts Triple pole and neutral 4 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed.
S&F in repair sheet metal enclosures for MCB distribution board 415 Volts Triple pole and neutral 8 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed.
S&F in repair 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN and current carrying capacity 40 Amps in the MCB DB complete with connection testing and commissioning all as specified and directed.
S&F in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed.
S&F in repair 415V, 10KA 'C' curve miniature circuit breaker (MCB) of TPN 16 To 32 AMP and current carrying capacity in the DB complete with connection testing and commissioning all as specified and directed.
S&F in repair Double pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 A, all as specified and directed.
G K CONSTRUCTIONS (BID ID -3141333)
M/S SRI BALAJI ENTERPRISES (BID ID -3137683)
SREE VARU ELECTRICALS (BID ID -3144341)
chowdeshwariconstructionco (BID ID -3145162)
RAMESH BABU CO (BID ID -3147690)
ARUNOTHAYA TRADERS (BID ID -3148206)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .