| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹22.4 L+₹3.2 L (16.8%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹23.4 L+₹4.2 L (21.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹23.4 L+₹4.2 L (22.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹24.6 L+₹5.4 L (28.3%)Rejected-Finance DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
28 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS BB CANTT SRINAGAR
REPAIR / MAINT OF LT NETWORK AND ALLIED WORK AT BB CANTT, SRINAGAR
2020_MES_402569_2
864/ws-45/2020-21
Open Tender
Civil Works
Item Rate
270 days
BB CANTT SRINAGAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹64,000
Yes
26 Feb 2021
14 Jan 2021
30 Jan 2021
21 Jan 2021
28 Jan 2021
21 Jan 2021
60 days
Amount
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth and getting out in hard/dense soil for foundation, laying of cables/pipes, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 1.00 above but exc 1.5 Mtr but not exc 3.0 Mtr in depth, complete all as specified and directed by Engineer-in-Charge.
M&L for dry sand cushioning to underground cable, 8cm thick before laying and 15cm thick after laying and stretching the cable, complete all as specified and directed by Engineer-in-Charge. Notes :- (a) Dry fine sand of best quality shall be used. (b) Punned thickness shall be measured and paid.
M&L for sub class 'B' old size brick, well burnt as covering to underground cables, laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading leveling and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (soil) to a distance not exc 50 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 100mm bore galvanised iron pipe, light grade with all fittings for cable protection, laid under road / culvert / drain, complete fixed with clamps, made out of 50x6mm thick MS flat, nuts & bolt of appropriate size including closing of ends with soft wooden wedge duly preformed with bitumenous material, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 80mm bore galvanised iron pipe, light grade with all fittings for cable protection, laid under road / culvert / drain, complete fixed with clamps, made out of 50x6mm thick MS flat, nuts & bolt of appropriate size including closing of ends with soft wooden wedge duly preformed with bitumenous material, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 50mm bore galvanised iron pipe, light grade with all fittings for cable protection, laid under road / culvert / drain, complete fixed with clamps, made out of 50x6mm thick MS flat, nuts & bolt of appropriate size including closing of ends with soft wooden wedge duly preformed with bitumenous material, complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 Metres deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level, connecting to the galvanised iron earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire, protected by provision of GI light grade pipe 15mm bore and including provision of concrete pit in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and including 20mm bore medium grade GI pipe for watering perforated at bottom 1.75 Mtr long placed on top edge of earth plate, layers of common salt and charcoal filling, test point made out of 40x6mm flat iron with fixing arrangement funnel, wire mesh and earth work in hard/dense soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 Mtr complete all as per electircal plate No. 03 of SSR-2009 Part-I and connecting to earth test point including testing on completion.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 Metres deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level, connecting to the galvanised iron strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire, protected by provision of GI light grade pipe 40mm bore and including provision of concrete pit in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and including 20mm bore medium grade GI pipe for watering perforated at bottom 1.75 Mtr long placed on top edge of earth plate, layers of common salt and charcoal filling, test point made out of 40x6mm flat iron with fixing arrangement funnel, wire mesh and earth work in hard/dense soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 Mtr complete all as per electircal plate No. 03 of SSR-2009 Part-I and connecting to earth test point including testing on completion.
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete for poles/stays etc., complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete for poles/stays etc., complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in foundation, filling in, mass concrete and copings and the like including necessary form work, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of existing old surface after brushing with metal brush or emery paper of steel tubular poles of 09 Mtr long and applying one coat of aluminium paint on the surfaces of steel tubular pole and painting black and white strips 04 Nos (each strip of 30cm height) with synthetic enamel paint of black and white colour, round the steel tubular pole alternatively from the bottom of the pole also including numbering of pole, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor 1100 Volts grade earthed, cross section area 150 Sqmm 3.5 core including taking up existing unsv cable, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor 1100 Volts grade earthed, cross section area 120 Sqmm 3.5 core including taking up existing unsv cable, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor 1100 Volts grade earthed, cross section area 95 Sqmm 3.5 core including taking up existing unsv cable, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor 1100 Volts grade earthed, cross section area 70 Sqmm 3.5 core including taking up existing unsv cable, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor 1100 Volts grade earthed, cross section area 50 Sqmm 3.5 core including taking up existing unsv cable, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor 1100 Volts grade earthed, cross section area 35 Sqmm 3.5 core including taking up existing unsv cable, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor 1100 Volts grade earthed, cross section area 25 Sqmm 3.5 core including taking up existing unsv cable, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor 1100 Volts grade earthed, cross section area 16 Sqmm 4 core including taking up existing unsv cable, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor 1100 Volts grade earthed, cross section area 10 Sqmm 4 core including taking up existing unsv cable, complete all as specified and directed by Engineer-in-Charge.
Dismantling / Taking up of steel tubular pole 9 Mtr long embedded in cement concrete etc. including transportation to store, complete all as specified and directed by Engineer-in-Charge.
Fixing only steel tubular pole, type 410 SP-31 (9 Mtrs long). Notes :- Excavation, earthwork and PCC shall be measured and paid seperately under relevant items of BOQ.
Supply and erecting in vertical position steel tubular swaged pole type 410 SP-31 (9 Mtr long) with 300x300x6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5 Mtr from ground level / coping and making 30cm high black and white strips with two coats of super enameled paint upto 1.5 Mtr from ground level / coping, complete all as specified and directed by Engineer-in-Charge.
S&F PVC seperators / spacers clamp mounted on ACSR conductor, suitable for 4 run, complete all as specified and directed.
Disconnecting, dismantling and taking down of unserviceable ACSR conductor of any size in any position complete including removing from any size of electric pole, complete all as specified and directed by Engineer-in-Charge.
Disconnecting and dismantling of unserviceable cross arms, bracings, supports, clamps, nuts, bolts etc. of any type including removing from any size of electric pole, complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, commissioning and testing ACSR conductor of any size on existing LT pole including copper binding wire or aluminium tab, complete all as specified and directed by Engineer-In-Charge.
Restretching of LT ACSR conductor and GI wire of any size and on any type of poles including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including refixing / readjusting line spans, line separators, cross arms on poles, complete all as specified and directed by Engineer-in-Charge. Note: Four lines i.e. 3 phase & neutral will be measured one span only
M&L for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, complete all as specified and directed by Engineer-in-Charge.
M&L for cradel hexagonal / rectangular, fabricated with galvanised steel wire 3.15/4mm dia, complete all as specified and directed by Engineer-in-Charge.
M&L for repair/replacement of damaged service aluminium conductor multistranded cable of any size with 6 sqmm 2 core PVC insulated service cable in service connction suspended by insulating hangers not more than 1 Metre apart including GI wire of 4 Sqmm size form LT pole to building complete including jointing on overhead line and connecting in distribution board provided in building, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 16 KA breaking capacity, thermal magnetic type of capacity 63 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 16 KA breaking capacity, thermal magnetic type of capacity 100 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 16 KA breaking capacity, thermal magnetic type of capacity 125 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 36 KA breaking capacity, thermal magnetic type of capacity 160 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 36 KA breaking capacity, thermal magnetic type of capacity 200 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 36 KA breaking capacity, thermal magnetic type of capacity 250 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 36 KA breaking capacity, thermal magnetic type of capacity 315/320 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 36 KA breaking capacity, thermal magnetic type of capacity 400 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole, 50 KA breaking capacity, thermal magnetic type of capacity 630 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge.
Cutting and trimming of tree branches to clear the over head lines in the arc of HT/LT over head lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed by Engineer-in-Charge. Notes :- All tools required for the job shall be arranged by the contractor within the overall cost quoted in the item.
S&F in replacement pin type insulator 100mm height, 65mm dia porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut, suitable for 1100 volts grade, complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps (31x5mm), washers, insulators bolts 14mm, washers and nuts, working pressure 1100 volts, height 100mm, 115mm dia, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement loop type insulator porcelain, vitreous, white, brown or green insulators including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 65x90mm clearance of hole 16mm, complete all as specified and directed by Engineer-in-Charge.
M&L for replacement stay assembly for electric poles complete with accessories (as shown in electrical plate No. 1 of SSR Part-I) stay rod of 20mm dia, 180cm long, stay wire of size 7/3.15mm dia and stay plate of size 30cm x 30cm x 6mm thick, complete all as specified and directed by Engineer-in-Charge. Note :- Excavation, earth work and PCC shall be measured and paid separately under respective items.
S&F in replacement danger notice plate of 1.6mm thick mild steel, viterous enemelled white with letters figures & conventional skull & bones in signal red colour and fixed with MS clamps of suitable size, bolts and nuts of approved size for HT, size 25cm x 20cm, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement danger notice plate of 1.6mm thick mild steel, viterous enemelled white with letters figures & conventional skull & bones in signal red colour and fixed with MS clamps of suitable size, bolts and nuts of approved size for LT, size 20cm x 15cm, complete all as specified and directed by Engineer-in-Charge.
M/S Bilal Construction
M/S U.K. ENTERPRISES
M/S NEW FAROOQ TRADERS
M/S ASHRAF CONSTRUCTIONS
M/S TRADE LINK
M/S Khan Hussain & Co.
M/S MOHD MAQBOOL RATHER
M/S REDLY ENGINEERS
M/S ZENITH TRADE LINK
M/S TAHIRA ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .