CONSTRUCTION OF CYBER CRIME UNIT AND SPECIAL BRANCH (B+G+5) AT 5 MANGALS ROAD PATNA IN THE DISTRICT OF PATNA WITH ELECTRIFICATION
144285
NIT-26/SBD/2026-27/GR-01
Open Tender
GENERAL
Patna
• Legal Status of Bidder
• Place of Registration
• Litigation History
• Registration No
• PAN No.
• GSTIN
• Character Certificate (with Letter No. Letter Date, Issuing Office)
• Electrical License Validity upto (in case of sub-contractors affedevit of both the parties)
• NOC for Debar (if required)
GENERAL
PERCENTAGE
L1
1
21 documents required · 21 mandatory
₹10,000
Processing Fee: 11800
₹52.7 L
CE, BPBCC, PATNA
27 Nov 2026
27 Nov 2026
24 Dec 2026
27 Nov 2026
22 Dec 2026
27 Nov 2026
4 Dec 2026
180 days
Boring, providing and installing bored cast-in-situ reinforced of grade M-25 of specified diameter and length below the pile cap, to carry a safe cement concrete piles working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc.(By Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap). 600 mm dia piles.
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge: Single pile above 50 tonne and upto 100 tonne capacity: Initial test.
Demolishing cement concrete including disposal of fmaterial within 50 metre lead: 1:3:6 or richer mix
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Extra for ecery additional lift of 1.5m or part thereof in: All kinds of soil
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m : All kinds of soil
Clearing jungle including uprooting of rank vegetation ,grass,bush wood ,treesand sampling of girth upto 30 cm measured at aheight of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared
Supplying chemical emulsion in sealed containers including delivery as specified: Chlorpyriphos/ Lindone emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos / Lindance E.C 20% with 1% concentration.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12mm diameter holes with cement mortar 1:2)1cement : 2 coarse sand) to match the existing floor. With Chlorpyriphos EC 20% with 1% concentration.
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns,piers, abutments, pillars,post. struts, buttresses, string or lacing courses, parapets, coping,bed blocks, anchor blocks, plin window sills, fillets etc. upt floor five level excluding the cost of centring,shuttering and finishing:1:1.5:3(1 Cement: 1:5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 40 mm nominal size)
Centring and shuttering including strutting, propping etc.and removal or form work for Foundations,footings, bases Columns
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4(1cement:2:2 coarse sand :4 graded stone aggregate 20mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufacturers.
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg. per square metre on damp oroof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balconies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cost in situ)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Stairs,(excluding landings) except spiral-staircaces.
Centring and shuttering including strutting, propping etc. and removal of form for: Arches,domes,vaults upto 6m span
Centring and shuttering including strutting, propping etc. and removal of form for: Small lintels not exceeding 1.5 m clear span, mouldings as in cornoces, window sills, string, courses, bands, copings,bed plates, anchor blocks and the like.
Centring and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walis-Under 20 cms wide
Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade,Chajjas, corbels etc. including edges
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de-shutering and de centring at all levels over a height of 3.5 m ,for every additional height of 1 metre or part thereof (Plan area to be measured): Suspended floors, roots, laning, beams and balconies (Plan area to be measured)
Centring and shuttering including strutting, propping etc. and removal of form for: Extra for shuttering in circular work (20% of respective centring and shuttering items)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 20 mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 25 mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 28 mm dia.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M-25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M-30 grade with minimum cement content of 350 kg/cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All work above Plinth level upto floor V Level. Concrete of M-25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength;including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M-30 grade with minimum cement content of 350 kg/cum
Extra for R.C.C work above floor V level for each four floors or part thereof.
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Brick work with bricks of class designation 100A in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in : Cement mortar 1:4(1 cement : 4 coarse sand)
Extra for brick work in super structure above plinth level upto floor V
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos .6 mm dia. MS bars at every third course of half brick masonry (with F.P.S.bricks)
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite of any colour and shade:Area of slab up to 0.50 sqm.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite of any colour and shade:Area of slab over 0.50 sqm.
Extra for fixing marble/granite stone over and above coresponding basic ite, in facia and drops of width upto 150 mm with expoxy resin based (Araldite or equivalent) adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform. Vanity counters and similar location in marble/stone work including necessary holes for pillar taps etc. including rubing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and Granite Stone of approved shade
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (avearage) thick base of cement mortar 1:4(1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat . Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames.30 mm thick Fiber glass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564,embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 150 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.50 mm all complete:With 12 mm mild steel U beading
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc.complete:125 x64 x1.90 mm
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing fire resistant door frame of section 50x60 mm on horizontal side & 35x60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120 gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters.The frame shall be filled with Mineral wool Insulation having density min 96 Kg/m³. The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M 10x80) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3 mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer- in charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-in- charge. The glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments).
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on backside of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge,all complete.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron ) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve,including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer-in-charge: 10 x 60 mm.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coar of approved steel primer, welded and bolted including special shaped wahers etc. complete : Hot finished seamless type tubes
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Extra for nosing in marble stone for treads
Extra for marble stone flooring in treads of steps. Not exceeding 30 cm in width.
Providing and laying Ceramic glazed floor tiles 400 x 400 mm (thickness to be specified by the manufacturer) of 1 st quality conforming to IS : 13755 of NITCO , ORIENT , SOMANY , KAJARIA or equivalent make in colours such as white , Ivory , Grey , Fume , Red , Brown , laid on 20 mm thick cement motar 1:4 (1 cement: 4 Coarse sand) including grouting the joints with white cement and matching pigments etc, complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete : Size of Tile 600 x 600 mm.
Providing and laying Vitrified tiles in floor in different sizes {thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Chequerred precast cement concrete tiles 22 mm thick with marbie chips of size 6 mm in footpath & coutyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning tec. Complete on 20 mm thick bed of cement mortar 1:4(1 cement:4 coarse sand) : Light shade using white cement.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia PVC Coupler
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.8mm thick with zinc coating not less than 275 gm/mz
Providing ridges or hips of width 60 cm over all width plain G.S.sheet fixed with G.I. J or, L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete : 0.80 mm thick with zinc coating not less than 275 gm/Sqm consider the length of the ridge 10.35 metres. The ridges will be made out of plain G.I. sheets 0.9 m x 1.8 m
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
Cement plaster in coarse sand : 20mm cement plaster of mix : 1:4(1cement : 4 coarse sand)
Forming groove of uniform size from 12 x 12 mm and upto 25 x 15mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Extra for providing and mixing water proofing material in proportion recommended by the manufacturers: 20mm cement plaster 1:4 (1 cement : 4 sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
White washing with whiting to give an even shade : New work (three or more coats)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture.
b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts
Providing and laying brick tiles of class designation 100 over mumty roof grouted with cement mortar 1:3 (1 cement :3 coarse and) mixed with 2% if integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement :3 fine sand) and finished neat: With F.P. brick tiles
Finishing walls with Epoxy paints(two or more coats) at all locations prepared and applied as per manufacturer!s specifications including appopriate priming coat,preparation of surface,etc complete.On steel work
Finishing walls with Epoxy paints(two or more coats) at all locations prepared and applied as per manufacturer!s specifications including appopriate priming coat,preparation of surface,etc complete.On concrete work
Providing and fixing aluminium work for doors, windows,ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required PDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing / aneling,C.P. brass /stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion:Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15).
Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc.. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of selfhealing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-incharge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and laqying integral cement based water proofing treatment including prepration of surface as required of roofs,balconies ,terraces etc,consisting of following operations,a)Applying and grouting a slurry coat of neat cement using 2.75Kg/sqm of cement admixed with proprietary water proofing compound cleaning the surface before treatment, b) Laying cement concrete using broken bricks/ brick bats 25mm to 100mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 over 20m thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admised with proprietary water proofing compound conforming to IS 2545 to required slope and trating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming tc IS 2645 in recommended proportions.(ii) 11 nd course of 20 mm cement plaster 1:3 (1 cement:3 coarse sand) mixed with water proofing compound in recommended proportion, (iii) Illrd course of applying blown or/ residual bitumen aplied hot at 1.7 kg. per sqm of area, (iv) Ivth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC shet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqni).
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm,
Providing and supplying aluminium extruded tubular and other aluminium sections as per the rchitectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS74,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
Designing, fabricating, testing, protection, installingand fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Per bag
DESCRIPTION
Providing and fixing frameless fixed glass partition made of 12mm thick clear toughened float glass of approved make , edges machine-polished and ground, fixed to the floor, walls, and ceiling using heavy-duty SS 304 grade U-channels / top and bottom patch fittings (Dorma / Ozone or equivalent), EPDM rubber gaskets, transparent silicone sealant, including cutting necessary cut-outs, notches, and holes for hardware, scaffolding up to all heights, cleaning the glass surface post-installation, complete as per architectural drawings and directions of the Engineer-in-Charge.
Providing and fixing Glass to Glass Lock, Material: 304-grade stainless steel with brushed, chrome, or matte black finish, Glass Thickness: Fits to 12 mm toughened, frameless glass. Operation: Double-bolt or single-bolt designs. Inside operates via a thumb-turn knob; outside operates via a computer-wave or brass key. all complete as per satisfaction of engineer In-Charge.
Providing & Fixing Typically SS 304 (best for anti-rust and corrosion resistance), Handle Types: "H" Shape, "C" Shape, Tube Thickness: 1.0 mm to 1.5 mm., Tube Diameter/Profile: Ranges from 32 mm for circular pipes, Finish: Satin Matt (SSS), Glossy/Polished (PSS), Matte Black, or Rose Gold., Compatibility: Suitable for glass door thicknesses of 12 mm, all complete as per satisfaction of engineer In-Charge.
Providing, Supplying and fixing of 6 mm thick Toughened glass in window as per Direction of Engineer Incharge
Supply and Installation of UPVC Fluted Louver Panels: Providing and fixing in position premium quality Unplasticized Polyvinyl Chloride (UPVC) / Heavy-duty PVC Fluted Louver Panels of approved shade, texture, and design pattern. The panels must have a minimum overall thickness of 10mm to 12mm, featuring core multi-groove linear hollow sections designed for architectural depth. The material must be 100% waterproof, termite-proof, borer-proof, and flame-retardant.
Providing and laying heavy-duty, seamless, self-levelling Polyurethane (PU) flooring system of 6 mm thickness over existing sound concrete/screed base. Scope includes mechanical surface preparation (grinding/scarifying) to achieve surface profile, cutting of 4mm x 4mm anchor grooves along margins, cleaning and removal of laitance/dust, applying a solvent-free epoxy/PU primer coat, filling structural cracks/joints with compatible PU patch compound, and laying the main self-levelling screed layer followed by a UV-resistant Aliphatic PU topcoat. The rate shall include the cost of all materials, specialized machinery, tools, plants, NABL-calibrated testing, taxes, and contractor profit, all complete as per technical specifications and directions of the Engineer-in-Charge.
Supplying and fixing heavy-duty PVC / rubberized polymer column/corner guard of size [1200 mm Height × 100 mm Width × 15 mm Thickness] in black color with high-intensity yellow/white retro-reflective safety strips for parking lots, basements, and industrial columns. The guard must be impact-resistant, weather-resistant, and anchored firmly to concrete/masonry column corners using heavy-duty expansion/fastening screws as per manufacturer specifications and site requirements all complete as per direction of EI.
Providing and fixing Glass fiber reinforced concrete screen/jali thickness 30-35 mm of approved pattern, design, thickness and colour. Jali made with 53 grade white cement, quartz silica sand, alkali resistant glass fiber, super plasticizer and polymer and UV resistant synthetic inorganic pigments etc. The screen/Jali shall be fixed by dry fixing with stainless steel 304 grade “L” shaped cramps, dash fasteners etc. complete. Rate shall included the structural Steel frame (Horizontal and Vertical member) support to hold the GRC Jalli at required building height to withstand wind pressure. The Technical specification of screen/jali shall be as under: Dry Density: > 1800 kg/cum Water Absorption: Less than 6% of dry weight by immersion over a period of 24 hours. Compressive Strength: > 400 Kg./CM2 (M-40 Grade) Wet Transverse Strength: > 7N /mm Abrasion Resistance: Less than 2.0 for E.H.D. Thermal Conductivity : 1.63 W/MK at 3% moisture content 1.80 W/MK at 5% moisture content 1200mm x 600mm GRC Circular Band
Providing, mixing, and applying a two-component, solvent-free epoxy resin bonding agent (Fosroc Nitobond EP or approved equivalent) for structural bonding of fresh, wet concrete or repair mortar to existing old concrete surfaces at construction joints, column/beam extensions, or patch repairs.
Providing and laying pre-applied, fully-bonded waterproofing and gas-proofing membrane (Fosroc Proofex Engage or approved equivalent) vertically over prepared temporary or permanent formwork, or adjoining structures of retaining walls. The system shall comprise a 4mm to 5mm thick cell mesh bonded to a blended polyethylene/polypropylene membrane, designed to form a permanent mechanical bond directly with freshly poured vertical concrete walls.
The installation must be done over a smooth, uniform substrate (such as concrete surfaces). Sheets must be hung vertically with the ribbed mesh surface facing inwards (towards the concrete pour) and securely fastened to the formwork substrate using Proofex Engage Detail Strips or approved mechanical fasteners at maximum 1-meter vertical intervals to eliminate sagging. Adjacent sheets must maintain a minimum 65-75mm overlap along the self-adhesive selvedge. All vertical joints, roll ends, and perimeter intersections must be firmly rolled and sealed using Proofex Engage Detail Strip and oversealed using an approved liquid membrane. All Complete as per direction of EI
Providing and laying pre-applied, fully-bonded waterproofing and gas-proofing membrane (Fosroc Proofex Engage or approved equivalent) below the foundation floor slab/raft. The system shall comprise a 4mm to 5mm thick unique cell mesh bonded to a blended polyethylene/polypropylene membrane, designed to form a permanent mechanical bond directly with freshly poured concrete.
The installation must be done over a smooth, prepared mud-slab/blinding concrete or compacted substrate. Sheets must be rolled out with the ribbed mesh surface facing upwards, allowing a minimum 65mm overlap along the self-adhesive selvedge. All roll ends and cut edges must be butt-joined using Proofex Engage Detail Strip (double-sided waterproof adhesive tape) and oversealed at the surface using an approved liquid membrane. All Complete as per direction of EI
Providing, laying, jointing, and testing of 150 mm nominal diameter heavy-duty PVC / HDPE perforated pipe, manufactured with precise perforations executed via CNC cutting technology to the specified slot dimensions, pattern, and open area percentage. The item includes wrapping the entire outer perimeter of the perforated pipe with a non-woven Geotextile filter fabric jacket (of specified GSM, e.g., 150/200 GSM) with a minimum overlap of 100 mm at joints, secured firmly with heavy-duty adhesive tape or ties to prevent soil ingress. all complete as per direction of EI
Providing, fabricating, and fixing 3D embossed custom-designed alphabet lettering, symbols, and architectural logos. The face and returns of the characters shall be precision-profiled using high-performance CNC Fiber Laser cutting machines to ensure absolute dimensional accuracy, burr-free edges, and crisp internal radii as per approved digital vector artwork. Fabricated from Grade 304 Stainless Steel (minimum 16-gauge / 1.5mm thickness) with a flawless uniform hairline brush or mirror-polish finish. Letters shall feature a returns/side-profile depth of 25mm to 50mm, meticulously jointed using seamless argon TIG welding. The entire assembly is to be securely mounted on the structural facade, masonry wall, or an Aluminum Composite Panel (ACP) base background using industrial-grade heavy-duty stainless steel anchor studs, fasteners, and high-tensile silicone adhesives. Rate shall be fully inclusive of all shop drawings, drafting approvals, scaffolding, structural engineering safety calculations, hoisting, tools, tackles, transit insurance, and flawless alignment at all heights as directed by the Engineer-in-Charge.
SIGNAGES WORK Providing and fixing of signages, modular curved frame technology, of various widths and lengths, to form suggested usages, made of aluminium extruded sections, duly anodised, all signages shall be provided with 0.6-0.8mm polycarbonate protecting film over the prints, of appropriate size, print shall on 0.6mm coated, YUPO, make, biodegradable sheet printed on HP 4500 UV flat bed printer., Model : Illusion by SIGNSUTRA or Equivalent.
Way finding ceiling hung sign (both side)
Toilets Gents, Ladies & Handicap (Wall Projected) (both side)
Room designation
DESCRIPTION
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required :610x510 mm bowl depth 200 mm
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete:Semi rigid pipe:40 mm dia
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing toilet paper holder :C.P. brass
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 .
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms: 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore: 15 mm nominal bore
Providing and fixing PTMT grating of approved quality and colour:Circular type:125 mm nominal dia.
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P.brass pillar tap
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing uplasticised PVC connection pipe with brass ions : 45 cm length :15 mm nominal bore
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:450 mm long towel rail with total length of 495 mm,78 mm wide and effective height of 88 mm, weighing not less than 170 gms
Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate of 20mm nominal size) over P.V.C. sheet Im x 1m x 400 micron, finished with 12mm cement plaster 1:3( 1 cement :3 coase sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia PVC Coupler
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Internal work - Exposed on wall: 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Internal work - Exposed on wall: 40 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Internal work - Exposed on wall: 50 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 25 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:15 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:32 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:40 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:50 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:65 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:80 mm dia nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary xcavation,foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 100A
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :15 mm diameter pipe
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :20 mm diameter pipe
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :25 mm diameter pipe
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :32mm diameter pipe
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :40 mm diameter pipe
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :50 mm diameter pipe
Providing and fixing G.I. Union in existing G.I. pipe line,cutting and threading the pipe and making long screws,including excavation,refilling the earth or cutting of wall and making good the same complete wherever required :20 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line,cutting and threading the pipe and making long screws,including excavation,refilling the earth or cutting of wall and making good the same complete wherever required :25 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line,cutting and threading the pipe and making long screws,including excavation,refilling the earth or cutting of wall and making good the same complete wherever required :32 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line,cutting and threading the pipe and making long screws,including excavation,refilling the earth or cutting of wall and making good the same complete wherever required :40 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line,cutting and threading the pipe and making long screws,including excavation,refilling the earth or cutting of wall and making good the same complete wherever required :50 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line,cutting and threading the pipe and making long screws,including excavation,refilling the earth or cutting of wall and making good the same complete wherever required :65 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line,cutting and threading the pipe and making long screws,including excavation,refilling the earth or cutting of wall and making good the same complete wherever required :80 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
DESCRIPTION
Providing and fixing C.P. cast brass twin coat hooks fixed to PVC rawl plug with SS screws Jaguar Cat. No. AON-7761 or approved equivalent.
Providing and fixing in position 100x50 mm dia GI reducing elbow including fix to floor with cement mortar.
Providing and fixing 100 mm dia. GI inlet fitting/ Extension Piece with 2 or 3 inlets of 32 to 50 mm dia, fixed to CI trap with Drip Seal joint and set in cement concrete as per drawing complete.
Providing and fixing in position 110x63 mm dia uPVC balcony Drain including fix to floor with cement mortor.
Providing and fixing of uPVC Waste pipes 6 kg/cm2 (IS: 4985:2000) including with all fittings e.g. couplings, tees, bends, reducers and screwed adoptors jointing with solvent cement as per Manufacturer's specifications complete including cutting holes or chases in wall and making good the same wherever required. (Waste pipe from fixtures AND LAB WASTE).
63 mm dia
50 mm dia
32 mm dia
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects.
Providing and fixing forged brass single acting air release valve with screwed inlet 25 mm dia.
DESCRIPTION
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:32 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:40 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:50 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:80 mm dia nominal bore
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :32mm diameter pipe
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :40 mm diameter pipe
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :50 mm diameter pipe
Painting G.I. pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality :80 mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :25 mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :32 mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :40 mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :50 mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :80 mm diameter pipe
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I. surface box 100mm top diameter,160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 100A
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge:External work:32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge:External work:40 mm nominal outer dia Pipes
DESCRIPTION
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms,depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc.and disposing of surplus excavated soil as directed , within a lead of 50 m:All kinds of soil:Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
Extra for excavating trenches for pipes, cables etc.in all kinds of soil for depth exceeding 1.5 m , but not exceeding 3 m.(Rate is over corresponding basic item for depth upto 1.5 meter.)
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Extra for ecery additional lift of 1.5m or part thereof in: All kinds of soil
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :180x150 mm size P type:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes :Size 90 x 80 cm :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes :Size 120 x 90 cm :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be isible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
DESCRIPTION
Earthwork in excavation over areas ( exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Extra for ecery additional lift of 1.5m or part thereof in: All kinds of soil
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1.4.8 (1 Cement :4 coarse sand :8 graded stone agregate 40 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size.) ( Shelves)
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balconies and access platform.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Brick work with bricks of class designation 100A in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be isible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:H D - 20 : Circular shape 560 mm internal diameter
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge,upto 90 metre depth below ground level:All types of soil:400 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge:200 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge:200 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete:200 mm clamp
DESCRIPTION
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge,upto 90 metre depth below ground level:All types of soil:300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level:All type of soil:300 mm dia
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges,fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge:150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge:150 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of:150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete:150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 150 mm dia
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia.
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 100 mm dia
DESCRIPTION
Supply, Lowering, installation & testing of KSB make submersible pumping set with 3 HP to 5 HP motor 4/5 stage pump suitable for 45-60 m3 hr. at 60 to 100 mtr. Head respectively. With Three Phase.
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Brick work with bricks of class designation 100A in foundation and plinth in : Cement mortar 1:4(1 cement : 4 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)( Foundation, Band at P.L.& S.Tank Cover)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete: Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 75mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee without door (T. Bend)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Per bag
DESCRIPTION
Providing and fixing on wall face unplasticised- PVC moulded fittings /accessories for unplasticised-PVC rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 75mm dia PVC Cowel.
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for sewerage including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion: 110 x 110 x110mm single equal Y without door
DESCRIPTION
Earthwork in excavation over areas ( exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms,depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc.and disposing of surplus excavated soil as directed , within a lead of 50 m:All kinds of soil:Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m : All kinds of soil
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Centring and shuttering including strutting, propping etc.and removal or form work for Foundations,footings, bases Columns
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M-25 grade with minimum cement content of 330 kg/cum
Add for using extra cement in the items of design mix over and above the specified cement content therein.
DESCRIPTION
Supplying and stacking at site.Good earth
Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately).
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer- in-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required: In gratings, frames, guard bar, ladders, railing, brackets, gets & similar works.
Drilling 6mm dia in M.S.angle iron for fixing of staples etc.as per building specification and direction of E/I.
Stone tile work for wall lining upto 10.0m height with special adhesive like araldite or equivalent over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand ) including pointing in-white cement with an admixture of pigment to match the stone: 8 mm thick (mirror polished and machine cut edge ): Granite black stone.
Stone tile work for wall lining upto 10.0m height with special adhesive like araldite or equivalent over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand ) including pointing in-white cement with an admixture of pigment to match the stone: 8 mm thick (mirror polished and machine cut edge ): Raj Nagar plain white marble / Udaipur green marble /Zebra black marble Granite black stone.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Boring, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles.
Extra over item No. 23.3 for providing additional bulb in under reamed piles, under specified dia meter (Only the quantity of extra bulbs are to be paid).: 300 mm dia piles.
Per bag
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufacturers.
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balconies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Arches,domes,vaults upto 6m span
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Mild steel 6.5 mm dia
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Mild steel 7.00 mm dia
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Mild steel 8.00 mm dia
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Providing and fixing flush door shutters conforming to IS : 2202 (Part-I) non-decorative type.core of block board construction with frame of 1st class tiard wood and well mathched commercial 3 ply veneering wiih vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including anodized aluminum butt hinges with necessary screws.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing steel glazed doors, windows and ventilatrs of standard rolled steel sections,joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with steel beading of approved shape and section with screw insted of glazing clips and special metal-sash putty of approved make complete including applying a priming coat of approved steel primer: including the cost of metal beading and other fitting except necessary hinges or pivots as required: Steel windows
Providing and fixing T-iron frames for doors. windows and ventilators of mils steel Tee-sections, joints miltred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concerete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including.
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required: In gratings, frames, guard bar, ladders, railing, brackets, gets & similar works.
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
12mm cement plaster of mix: 1:4 (1 cement : 4 coarse sand)
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying primer coat : With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood):Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Per bag
DESCRIPTION
Earthwork in excavation over areas ( exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
In or under water and/or liquid mud, including pumping out water as required Extra due to slow progress and dewatering: 20% of the rate of item (20% of the rate of the item. The extra percentage in rate is applicable in respect of each item but limited to quantities ofwork executed in
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1.4.8 (1 Cement :4 coarse sand :8 graded stone agregate 40 mm nominal size)
Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. complete (The quantity will be calculated by multiplying the depth measured form the sub-soil water level upto centre of graity of concrete under sub-soil water water level with quantity of concrete in cum executed uder sub-soil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored.)
Centring and shuttering including strutting, propping etc.and removal or form work for Foundations,footings, bases Columns
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balconies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walis-Under 20 cms wide
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de-shutering and de centring at all levels over a height of 3.5 m ,for every additional height of 1 metre or part thereof (Plan area to be measured): Suspended floors, roots, laning, beams and balconies (Plan area to be measured)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Extra for laying reinforced cement concrete in or under water and/or liquid mud including cost or pumping or bailing out water and removing slush etc. complete. (Rate same as per item No, 4.29) Note:-The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1 m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M-25 grade with minimum cement content of 330 kg/cum
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Brick work with bricks of class designation 100A in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required: In stringers, treads landings etc. of stair cases including use of required plates wherever required all complete.
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required: In gratings, frames, guard bar, ladders, railing, brackets, gets & similar works.
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings complete jncluding applying a priming coat of approved steel primer. Using M.S. angle 40x40x6 mm for diagonal braces
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4: 20 to 25 mm thick.
Kota stone slabs 20 mm thick in risers of steps skirting. Dado & pillars laid on 12 mm (average (thick cement mortar 1:3 (1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Details of cost for 10 sqm.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
18mm cement plaster in two coat under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand finished rough with sponge
6mm cement plaster to ceilling of Mix : 1:3 (1 cement : 3 coarse sand)
Extra for providing and mixing water proofing material in proportion recommended by the manufacturers: 12mm cement plaster 1:4 (1 cement : 4 sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Epoxy paints(two or more coats) at all locations prepared and applied as per manufacturer!s specifications including appopriate priming coat,preparation of surface,etc complete.On concrete work
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:H D - 20 : Circular shape 560 mm internal diameter
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and Placing in position suitable PVC water stops for construction/expansion joints between two RCC memberrs and fixed to the reinforfement with binding wire before pouring concrete etc.complete: Serrated with central buld (225 mm wide, 8-11 mm thick).
Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20micron HMHDPE film sandwitched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 100 grouted with cement mortar 1:3 (lcement:3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12mm layer of cement mortar 1:3 (1 cement: 3 fine sand) and finished neat which shall be paid for separately .
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100%polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) forvertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer- in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) forvertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water)for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer- in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.
Per bag
DESCRIPTION
Screened through sieve of I.S. designation 16 mm
Screened through sieve of I.S. designation 4.75 mm
Fine dressing of the ground.
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
With grass Turf
Holes 1.2 m dia and 1.2 m deep
Holes 90 cm dia, and 90 cm deep
Holes 60 cm dia, and 60 cm deep
Holes 45 cm dia, and 45 cm deep.
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge.
Providing and fixing M. S. tree guard 45 cm square in plan, height 1.20 metre above ground level and 0.40 metre below ground level. The vertical members shall consist of four nos. angle iron of size 25x25x3 mm, 1.6 m long, one at each corner and 8 nos flat iron of size 25x3 mm, 1.2 m long. The vertical members shall be welded to 4 nos. 25x6 mm M. S. flats placed horizontally around the vertical member of the cage. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD/ PWD/ any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer, complete in all respect.
Top inside dia 35 cm, outer bottom dia 25 cm, total height 35 cm with wall thickness of 25.4 mm
Play grounds / Public parks (as per yard stick 1Mali =2.00Acre).
Providing & fixing of White River (Stone) Pables size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.
Providing and applying anti termite treatment of infected trees i/c all branches/leaves by spraying chemical emulsion 0.5% (Chlorpyriphos 20% EC) concentration through power spray machine (@ 100 ml Chlorpyriphos per tree i/c cost of chemical) and as per direction of officer-in-charge.and as per direction of officer-in-charge.
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.
Providing and Displaying plants Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot, as per direction of the officer-in-charge.
Providing and Displaying plants Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
Providing and Displaying Bismarkia Palm plant 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Foxtail palm plant well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge.
Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of Bottle palm plant of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge.
Supply and stacking of Ficus religiosa (Peepal) plant of height 150-165 cm. in big poly bags of size 30 cm as per direction of the officer-in-charge.
Supply and stacking of Nauclea cadamba (Kadam) plant of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.v
Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180- 195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge.
Supply and stacking of plant Nerium oleander (kaner) of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm as per direction of the officer-in-charge.
Per bag
DESCRIPTION
Providing and Fixing M. S. pipe as per IS:1239 ( Heavy Class ) complete with all fittings like unions, couplings, bends, elbows, tees, offsets, reducers, flanges, etc. as per requirement at site including painting with two coats of synthetic enamel paint, cutting and making good the walls complete. The cost shall include the MS / GI structural supports as per approved drawings and specifications.
200 mm dia(7.35mm thick) IS:3589
150 mm dia.
100 mm dia.
80 mm dia.
50 mm dia.
40 mm dia.
32 mm dia.
25 mm dia.
Providing and fixing ISI marked SS-304 fire hydrant valve 80 mm inlet with single outlet and fitted with 63 mm dia instantaneous female coupling on the outlet complete including companion flanges, pvc black cap and chain, nuts, bolts and 3 mm thick compressed asbestos gasket at locations as per drawings ( inlet flange as per IS: 5290-1969 Class C ).
Providing and fixing first aid fire hose reel drum wall mounting & swinging type fitted with 20 mm dia 30 m long high pressure hose as per IS : 5132 with 5 mm outlet SS nozzle with shut off valve ( IS: 884-1969).
Providing and fixing 63 mm dia 15 m long EPDM lined fabric hose including SS male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to IS : 636 Type II and coupling to IS: 903 – 1975 with ISI certification.
Providing and fixing standard short size SS branch pipe with nozzle 16 mm dia. Outlet with standard instantaneous type 63 mm dia. Coupling ISI marked.
Providing and fixing 25 mm dia brass ball valve full bore type with lever and screwed female ends. ( 20 kg./sq. cm.)
Providing and fixing fire hose cabinet fabricated from 16 gauge M.S. sheet with double glazed front door and pad locking arrangement, painted Fire Red with stove enameled paint and FIRE HOSE written on front including necessary supports ( to house two lengths of canvas hose with couplings, branch pipe and nozzle).
Providing and fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanges and complete in all respects.
200 mm dia
150 mm dia.
100 mm dia.
80 mm dia.
Providing and fixing C.I. double flanged horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 3mm thick compressed asbestos gasket with companion flanges, complete in all respect.
200 mm dia.
150 mm dia.
100 mm dia.
80 mm dia.
Providing and fixing 25 mm dia gun metal single acting air release valve with screwed inlet tested for 20 kg. / cm².
Providing and fixing 150 mm dia Three –Way Fire brigade connection consisting of 63 mm dia instantaneously male coupling ( To be connected to riser ).
Providing and fixing gun-metal 4-way fire brigade inlet connection of 4 nos. 63mm dia instantaneous type male coupling. (to be connected to static tank).
Providing and fixing fire brigade suction (draw out connection) with female coupling as per I.S:902-1974 complete and with 150mm dia. suction pipe and foot valve (To be connected to static tank)
Providing and fixing stored pressure Multipurpose fire extinguisher consisting of welded M.S. cylindrical body, squeeze lever discharge valve, 30 cms long high pressure discharge hose ISI marked as per IS:15683 including fixing to wall with brackets etc. complete.
Capacity 6 Kg.
Providing and fixing CO2 extinguisher consisting of seamless MS cylindrical body squeeze lever discharge valve, internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle ISI marked as per IS 13869 including fixing with dash fasteners etc. complete.
Capacity 4.5 kg.
Providing and fixing horizontal split casing single/multi stage, single/multi outlet pumping set with bronze impeller with C.I. body and connected by a flexible coupling to a totally enclosed fan cooled induction motor mounted on a common structural base plates with all pump accessories complete as per specifications including pressure gauges with gunmetal isolation valves and anti vibration pads, motor to be suitable for 415 volts, 3 phase, 50 cycles A.C. supply (Specifications as per fire fighting requirements and on the pattern of TAC or local authority approval) as per instruction with starter & cabling and starter to be placed at ground level.
Terrace Pump
Main fire Pump & Sprinkler Pump
Jockey Pump
Diesel Pump
Panel for Fire Pumps
Providing and fixing heavy duty aluminium armored cables 1.1 KVA grade including necessary support clamps at ceiling level and connection legs complete in all respects.
Power cable 3 core 16 Sq.mm
Power cable 3.5 core 25 Sq.mm
Supply, installation, testing and commissioning of Fire Alarm Control Panel with LCD display having battery charger & batteries of 2 loop capacity.
SITC of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required..
SITC of repeater panel with 320 character/Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
SITC of intelligent analog addressable photothermal detector complete with mounting base as required.
SITC of response indicator.
SITC of fault isolator complete base as required.
SITC of addressable manual call point complete as required.
SITC of addressable horn cum strobe complete as required.
Supplying & laying of 2 x 1.5 sq. mm fire alarm armoured cable, 600/1100V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required.
Providing, Fixing and testing of UL listed sprinkler head, Upright / Pendant type standard response sprinkler with quartzoid bulb overrating temperature 68°C of 15 mm orifice and k factor 80 made out of forged brass and chrome finished.
Providing and fixing UL/Fm listed powder coated finish Escutcheon plate complete including fixing in position on pipe and ceiling complete in all respects. (Size=15NB)
Providing and fixing pressure switch in M. S. pipe line including connection etc. as required.
Providing and fixing pressure gauge in M. S. pipe line including connection etc. as required.
Providing & fixing of Air Vessel.
DESCRIPTION
Wiring for light point /Fan Point/ exhaust fan point/ call bell point with 1.5 Sq.mm FR PVC insulated Copper conductor single core cable in surface/ recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. Box etc. as required. (a) Group C
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. 4 X 6 sq, mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. 4 X 10 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. 4 X 16 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4x25 mm2 + 1x16 mm2)
Supplying and fixing following modula'r switch/ socket on the existing modular plate & switch box including connections but excluding modular plate.etc. as required. 5/6 amps switch
Supplying and fixing following modula'r switch/ socket on the existing modular plate & switch box including connections but excluding modular plate.etc. as required. 15/16 amps switch
Supplying and fixing following modula'r switch/ socket on the existing modular plate & switch box including connections but excluding modular plate.etc. as required. 3 pin , 5/6 amps socket outlet
Supplying and fixing following modula'r switch/ socket on the existing modular plate & switch box including connections but excluding modular plate.etc. as required. 6 pin, 15/16 amps socket outlet
Supplying and fixing stepped type electronic fan regulatoron th existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' 160 A, 36 KA, FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' 630 A, 50 KA, TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' 8OO A, 50 KA, TPMCCB
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.18 watt
Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing 70112 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection and complete u.,ith integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.45 watt
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.90 watt
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required9/10 watt LED lamp 12 watt
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 185 sq. mm and upto 400 sq. mm
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 400 sq. mm, 3.5 core
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing of lightning conductor final made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes tec. Complete as required.
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. (For Horizontal run)
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. (For vertical run)
DESCRIPTION
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above Upto 35 sq. mm
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 35 sq. mm. 3.5 core
Supply, Installation and commissioning of Silent type, Air cooled 50 KVA DG set with AMF control with copper earthing etc as required.
Construction of cemented platform of minimum 2 feet height from finished ground level of suitable size as prescribed by manufactrurer of DG set with polycarbonate sheet roof shelter framed on iron frame structure etc as required to install 50 KVA DG silent
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I. box etc as required. (a) Group B
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required. 100 A
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCBilsolator) 5 way, Double door
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6 A to 32 A, TP&N
Supptying and fixing following rating, 24Al4L5 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required' 40 A to 63 A, SPN
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying and fixing 70112 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection and complete u.,ith integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 25 sq. mm, 3.5 core
DESCRIPTION
DESCRIPTION
EQUIPMENTS :
Variable Refrigerant Flow System
Rs. Only
Rs. Only
Rs. Only
SUPPLY of VRF Evaporating (Indoor) Units
Rs. Only
Rs. Only
Rs. Only
1.5 HP (1.2 TR) Ceiling Mounted Low Static Ductable Unit
2.0 HP (1.6 TR) Ceiling Mounted Low Static Ductable Unit
2.5 HP (2.0 TR) Ceiling Mounted Low Static Ductable Unit
3.0 HP (2.5 TR) Ceiling Mounted Low Static Ductable Unit
Rs. Only
Rs. Only
4.0 HP (3.2 TR) Ceiling Mounted Mid Static Ductable Unit
5.0 HP (4.0 TR) Ceiling Mounted Mid Static Ductable Unit
6.0 HP (4.8 TR) Ceiling Mounted Mid Static Ductable Unit
Rs. Only
Rs. Only
8.0 HP (6.4 TR) Ceiling Mounted Hi-Static Ductable Unit
10.0 HP (8.0 TR) Ceiling Mounted Hi-Static Ductable Unit
12.0 HP (9.6 TR) Ceiling Mounted Hi-Static Ductable Unit
16.0 HP (12.8 TR) Ceiling Mounted Hi-Static Ductable Unit
20 HP (16.0 TR) Ceiling Mounted Hi-Static Ductable Unit
ACCESSORIES:
Refnets ( Y- Joints) for Indoor units to Indoor Unit
Refnets ( Y- Joints) for outdoor units to outdoor Unit
REMOTE CONTROLLER
Wireless Remote for Ductable & 4-Way Cassette Indoor Units
Receiver Kit for Ductable & 4-Way Cassette Units.
DESCRIPTION
INSTALLATION & LOW SIDE WORKS
INSTALLATION OF VRF OUTDOOR UNITS.
Rs. Only
Rs. Only
CEILING MOUNTED LOW-STATIC DUCATBLE TYPE INDOOR UNITS
Rs. Only
1.5 HP (1.2 TR) Ceiling Mounted Low-Static Ductable Unit
2.0 HP (1.6 TR) Ceiling Mounted Low-Static Ductable Unit
2.5 HP (2.0 TR) Ceiling Mounted Low-Static Ductable Unit
3.0 HP (2.5 TR) Ceiling Mounted Low-Static Ductable Unit
CEILING MOUNTED MID-STATIC DUCATBLE TYPE INDOOR UNITS
Rs. Only
4.0 HP (3.2 TR) Ceiling Mounted Mid-Static Ductable Unit
5.0 HP (4.0 TR) Ceiling Mounted Mid-Static Ductable Unit
6.0 HP (4.8 TR) Ceiling Mounted Mid-Static Ductable Unit
CEILING MOUNTED HI STATIC DUCATBLE TYPE INDOOR UNITS
Rs. Only
8.0 HP (6.4 TR) Ceiling Mounted Hi-Static Ductable Unit
10.0 HP (8.0 TR) Ceiling Mounted Hi-Static Ductable Unit
12.0 HP (9.6 TR) Ceiling Mounted Hi-Static Ductable Unit
16.0 HP (12.8 TR) Ceiling Mounted Hi-Static Ductable Unit
20 HP (16.0 TR) Ceiling Mounted Hi-Static Ductable Unit
Refrigerant Piping (VRF System)
Rs. Only
54.0 mm dia with 19mm thick insulation
50.8 mm dia with 19mm thick insulation
44.4 mm dia with 19mm thick insulation
38.1 mm dia with 19mm thick insulation.
31.8 mm dia with 19mm thick insulation.
28.6 mm dia with 19mm thick insulation.
25.4 mm dia with 19mm thick insulation.
22.2 mm dia with 19mm thick insulation.
19.1 mm dia with 13mm thick insulation.
15.9 mm dia with 13mm thick insulation.
12.7 mm dia with 13mm thick insulation.
9.50 mm dia with 13mm thick insulation.
6.40 mm dia with 13mm thick insulation.
Drain Piping
Rs. Only
25 mm dia
32 mm dia
Control & Transmission Wiring
2core 1.5/1.0/0.75 sq.mm flexible control cable with saddles/supports & PVC conduits with hard PVC Pipe to connect Outdoor units with Indoor units
Installation, Testing & Commissioning of Multikit Joints
Commissioning of VRF systems including topping of R410A gas as per site requirements. Refrigerant shall be environmental friendly R410A.
Rs. Only
G.I Duct Distribution Works
Rs. Only
Ducting work with 22G sheet metal
Ducting work with 24G sheet metal
Rs. Only
Supply, installation, testing & commissioing of Duct Thermal insulations with Nitrile Rubber Insulation of ducting with 9mm thick cross link sheet, complete with seal at the joints and nylone box straping etc..
Supply, installation, testing & commissioing of Duct Acoustic insulations of ducting with 10mm thick cross link sheet (armasound), complete with seal at the joints and nylone box straping etc..
Canvas Connection & Mouth Connection For Indoor unit.
TOTAL Rs P
Non Schedule Item
Non Schedule Item
Non Schedule Item
Non Schedule Item
Non Schedule Item (MR)
Non Schedule Item (MR)
Non Schedule Item (MR)
Legal Status of Bidder
Place of Registration
Principal Place of Business
Power of Attorney for Signatory Bid.
Satisfactory completed at least one similar work of value not less than 50% of estimated cost.
Total Requirement Value (50% of BOQ)
Actual Qnty done
Earth Work + Sand filling work
Brick Work
RCC + PCC
Stone And Tile Flooring
Aluminum Work
Intergral/ waterproofing work with A.P.P Sheet
Water Supply & Sanitation work
Electrical work
Steel Truss
Amount of Existing commitments and ongoing works in Rs with duly affidavit & issued by proper authority.(Not less than Executive Engineer)
Amount of Work for which Bid already submitted in Rupees
Building Contract Package Size **
Rs.20-50 Crores
Concrete Batching & Mixing plant Minimum capacity 15m3/hr .
Pump for concreting (Optional)
Transit Mixture
Steel shuttering
Rs. 2-10 Crores
Project Manager/ B.E. Civil + 10 Years Exp. (5 years as Manager) or retired E.E.
Site Engineer/ B.E. Civil + 07 Years Exp. (3 years in Building Construction) or retired A.E.
Plant Engineer/B.E. Mech./ Civil + 05 Years Exp. or Dip. Mech + 07 Years Exp. or Retired J.E.
Quality Engineer /B.E. Civil + 05 Years Exp. or Dip. Civil + 07 Years Exp.
Soil & Material Engineer/ B.E. Civil + 07 Years Exp.
Survey Engineer/B.E. Civil + 03 Years Exp. or Dip. Civil + 05 Years Exp.
upervisor JE /Fresh Graduate in Civil or Diploma Civil + 03 Years Exp.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
e NIT 26 SBD 2026-27.pdf
NIT • 1.88 MB
GR-01 BOQ-26 2026-27.xls
NIT • 1.04 MB
GR-01 TECH-26 2026-27.xls
NIT • 0.05 MB
GR-01 SBD-26 2026-27.docx
NIT • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .