Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC D NO 32 1 211 2 BOWDARA ROAD VISAKHAPATNAM 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹36.8 L+₹1.7 L (4.84%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹40.9 L+₹5.8 L (16.6%)Rejected-AOC 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L3 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
15 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, St.Thomas Mount
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
REPAIRS TO LOW TENSION EXTERNAL ELECTRIC SUPPLY AND OTHER ALLIED WORKS AT PALLAVARAM, BAFFLE RANGE, MH, 100 OR QTRS, DEFENCE COLONY AND APS CHENNAI UNDER GE STM
2023_MES_622917_1
8375-REPAIRS TO LOW TENSION EXTERNAL ELECTRIC SUPP
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE STM
As per tender Documents
6 documents required · 6 mandatory
₹500
Garrison Engineer, St.Thomas Mount
₹89,000
Yes
12 Jan 2024
12 Oct 2023
23 Nov 2023
12 Oct 2023
15 Nov 2023
27 Oct 2023
12 Oct 2023 - 23 Oct 2023
Amount
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of stays & Poles, laying of cables etc and getting out in soft / loose soil all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm using excavated soil all as specified and directed.
Removing excavated material/ surplus soil not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed.
Supply, lay / spread in trenches, sieving sand including cleaning, spreading, leveling, punning for laying /cushioning of cable all as specified and as directed. Note: Punned thickness shall be measured and paid.
Supplying and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150mm x 40mm complete including removing old bricks from trenches and taken as schedule of credit.
M&L for Cement concrete Type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete including form work.
M&L for Cement concrete Type C 1 1:3:6 (20mm graded aggregate) for coping to the poles with finishes with out using extra cement.
Disconnecting and taking out the old unserviceable LT UG cable in trenches,wall & poles and taken as credit including supply and Laying in trenches / poles / wall etc LT UG Cable XLPE insulated, armoured, heavy duty with multistranded aluminium conductor, 1100 volts grade conforming to IS specifications and of the following sizes:- Note: Lugs and glands are deemed to be included in the rate quoted for laying of cable and to be used wherever required while connecting cables to the panel board. Earth work such as excavation, refilling etc, shall be measured and paid separately under relevant item:-
(a) LT UG cable 2 core 10 sqmm
(b) LT UG cable 4 core 16sqmm
(c) LT UG cable 4 core 25sqmm
(d ) LT UG cable 3.5 core 35sqmm
(e) LT UG cable 3.5 core 50sqmm
(f) LT UG cable 3.5 core 70sqmm
(g) LT UG cable 3.5 core 95 sqmm
(h) LT UG cable 3.5 core 120sqmm
(j) LT UG cable 3.5 core 185sqmm
Re- laying only ( where directed at site) in trenches and connecting with suitable size of cable jointing kit/lugs/ thimble etc. serviceable under ground cable retrived from taking out as Srl No - 09 of above schedule of following sizes:- Note:- Cable jointing kit will be measured & paid separately under relevant items of Sch 'A'.
(a) LT UG cable 4 core 16 sqmm
(b) LT UG cable 4 core 25 sqmm
(c ) LT UG cable 3.5 core 35 sqmm
(d) LT UG cable 3.5 core 50 sqmm
(e) LT UG cable 3.5 core 70 sqmm
(f) LT UG cable 3.5 core 95 sqmm
(f) LT UG cable 3.5 core 120 sqmm
(f) LT UG cable 3.5 core 185 sqmm
S&F Straight through joints (epoxy) heat shrink type for underground cable including joint kits and labour complete for making joints suitable for LT PVC sheathed / armoured heavy duty cables with aluminium conductor of following sizes :-
(a) LT UG cable upto 4 core 16
(b) LT UG cable 3.5/4 core 25 sqmm to 50
(c ) LT UG cable 3.5 core 70 to150sqmm
(d) LT UG cable 3.5 core 185 to 300 sqmm
Supply and lay in repairs steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 40mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed
Supply and lay in repairs steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 80mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed
Supply and lay in repairs steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 100mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed
Taking down the old unserviceable junction box and taken as credit including S&F Junction box PVC (FRP) Junction Boxes weather proof type with hinged type door off white colour of size 240x130x110mm with three pole connector and 1 No neutral link complete fixed on pole with suitable clamps, bolts and nuts with fixing arrangements all as specified and directed. Make : Sintex or equivalent.
Dismantling steel poles/ struts, any size including pcc couping.
Supply and erect steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP- 31 (9.00 metres long) conforming to IS-2713 including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer over the exposed surface and applying two coats of black bitumenous paint over the embeded portion of pole, erecting in truly vertical position including excavation in any strata and earth work complete all as specified and directed. Note :- PCC for foundation and coping will be measured & paid separately under relevant items of Sch 'A'.
M&L for removing the existing street light fitting of any type & make and Supply & installation of new street light fittings,60W LED 5700K New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaries with high power LED as light source in the existing pole duly wired complete all as specified and directed.
M & L for dismantling and taking down the existing street light fitting led type for repair and replacing the unservicable LED driver with new upto 100W LED 5700K and refixing the same in the existing pole duly wired complete all as specified and directed.
M&L for removing the existing street light fitting of any type & make and Supply & installation of new 90 W LED 5700K New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaries with high power LED as light source in the existing pole duly wired complete all as specified and directed.
Removing the existing Gate light & Supply and installation of new 40W LED 5700K New generation Post top energy saving & environmental friendly long life versatile spun aluminium IP66 roadway luminaries with high power LED as light source and connecting in the existing cable complete all as specified and directed.
Removing the existing unserviceable bollards light & Supply and installation of new 9 W/10W LED bamboo series IP 65, out door luminaires, New generation energy saving & environmental friendly long life aesthetically designed aluminium land scape luminarire for diffused lighting with high power LED Bollards as light source and connecting in the existing cable complete all as specified and directed Make:- Havells Cat part MOUNTBL10WLED830PSYMTOPMMA/ BAJAJ cat No. BGBOL 605 9W LED WW / CROMPTON cat No. LBLA-10-CDL.
Supply and laying 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 3 core 2.5 sq. mm nominal cross section in service connections/strret light connection from junction box to street light fittings.
Removing the existing unserviceable flood lights from high mast poles and supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Dismantling unserviceable power factor improvement capacitor of various capacities and Supply and fix heavy duty Cylindrical capacitors AC 440 volts, 50 Hz, Delta connection new power factor improvement capacitor of following capacities complete all as specified and directed. Make : havells, ABB or equivalent
(a) 25 KVAR Capacity
(b) 20.0 KVAr Capacity
(c ) 15 KVAR Capacity
(d) 10 KVAR Capacity
(e) 5 KVAR Capacity
(f) 3 KVAR Capcity
Dismantling unserviceable capacitor duty contactor and Supply and fix capacitor duty contactor of following capacities complete all as specified and directed. Make : havells, ABB or equivalent
(a) 25 KVAR Capacity
(b) 20.0 KVAr Capacity
(c ) 15 KVAR Capacity
(d) 10 KVAR Capacity
(e) 5 KVAR Capacity
(f) 3 KVAR Capcity
S & F MCCB 3 pole 400 Amps,415 volts with rupturing capacity 36 KA. All as specified including taking out old one.
S & F MCCB 3 pole 250 Amps,415 volts with rupturing capacity 25 KA. All as specified including taking out old one
S & F MCCB 3 pole 125 Amps,415 volts with rupturing capacity 16KA. All as specified including taking out old one
S & F MCCB 3 pole 25 to 100 Amps,415 volts with rupturing capacity 16 KA. All as specified including taking out old one.
Preparation of old surface and painting of steel tubular electric poles above coping level including brackets,clamps etc with good quality silver paint(two coat) complete including writing pole no and all as specified and directed.
Finding and rectification of electrical fault by Checking of external/internal(LT) elect supply feeder, street light feeder,OH conductors /under ground cables using elect tools, equipments and safty devices after arranging elect shut down of feeders from sub station to remove elect faults like tightning of loose connection,removing of any electric short,meggring of cable,excavation of soil for removing of faulty cable on a particular span and relaying of cables after removing of fault, re-tightning of cable lugs etc all as required at site and as directed by Engr in Charge. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safty devices. (ii) Any major materials used for rectification of faults like Cables,MCB/MCCB/cable jointing kits/cables of any type etc will be measured and paid seperately or supplied by department.(iii) Rate including hire of HT/LT fault Locaterany other tools/equipments and Earth Work. works should be completed with in 12 hrs.
Material and labour for servicing DG Set Engine complete oil servicing, necessary replacement of below mentioned spares and servicing work for following KVA DG Set incl 6 months warrantee for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant as required.
(a) DG set 380 KVA
(b) DG set 82.5 KVA
Material and labour for general oil servicing of DG Set Engine complete and replacement of below mentioned spares and servicing work for 15 KVA DG Set incl 6 months warranty for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant - 1 Ltrs.
Dismantling self starter of any make from diesel engines of any make, opening up, overhauling / servicing including replacement of armature coils bushes carbon brushes, springs, screws, etc., assembling back, re-fixing and testing for genset capacity following capacity:-
(a) DG set 380 KVA
(b) DG set 82.5 KVA
(c) DG set 15 KVA
M&L fuel pump & Fuel injectors calibration charges for DG set capacity for followings KVA complete all as specified and as directed by Eng-in-Charge.
(a) DG set 380 KVA
(b) DG set 82.5 KVA
'V' belt for fan / dynamo / water pumps for genset capacity for followings KVA (Make : FENNER / DUNLOP)
(a) DG set 380 KVA
(b) DG set 82.5 KVA
M&L for replacement of automatic voltage regulator (AVR) of armature of DG set capcity for followings KVA, 415 volts 3 phase 1500 RPM 50 Hz suitable make.
(a) DG set 380 KVA
(b) DG set 82.5 KVA
Material & Labour for Cutting and cleaning the tree branches around the street light poles/ /sub stn/ LT OH lineconductors and maintain 2 mtr gap all around free from branches of tree and clear the site and throw away cut branches etc, to a distance exceeding 50m all as directed. Note: Span shall be measured along with the direction of OH/ LT.
Supply, install, test & commissioning LT panel out door, floor mounted/pedestal type,cubical, self supported,CPRI approved ,front and rear openable , double door hinged type with locking arrangement and slopping top canopy ,suitable ventilations on both sides with wire mesh, IP-52 protection with dust and vermin proof etc.fabricated out of 3.15 mm CRCA sheet duly powder coated with 7 tank chemical process,mounted/fixed on and including MS angle iron stand of 1.0 mtr height (50 cm above FFL and 50 cm below FFL) ,fabricated out of 50x50x6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation,control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size/capacity of copper strips for switch gear connection from main bus bar,earth bus strip of 32x6 mm size for entire length of panel ,suitable size of MS gland with gland plate and alluminium lugs/thimbles for all incoming/out going cables etc.complete all as directed by Engineer-in-Charge and accommodating the followings:-
Removing of old earthing including earth plate and M&L for Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron earth strip 25x4 mm by means of bolts, washers ,watering pipe 20mm dia, medium grade GI pipe,with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fitting as protection pipe for strip from plate electrode to test point /plant/machineries etc. including necessary excavation and earth work in any type of soil, salt, charcoal dust, concrete pit in PCC (1:3:6) type C-I having outer dimension 60cmx60cmx60cm and internal dimension 30cmx30cmx30cm, pre-caste RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia deformed bares @15 cm centre to centre both direction and 10 mm dia MS handle of suitable size charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
PSK Enterprises
EVEREST ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .