Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC | ₹49.2 L Quoted ₹55.0 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹55.6 L+₹62,200 (1.13%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | ₹55.6 L+₹62,200 (1.13%) | L2 | Rejected-Finance Being other than lowest tenderer |
| 3 | L3₹92.3 L+₹37.3 L (67.8%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹92.3 L+₹37.3 L (67.8%) | L3 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
3 Nov 2021, 6:00 pmClosed
GE (NW) KUNJALI
DR HOMI BHABHA ROAD, NAVY NAGAR, COLABA, MUMBAI - 400 005
8407 REPAIR MAINT OF LT PANELS COPE POINTS AND SWITCH GEAR AT VARIOUS JETTIES WHARF AT ND MBI
2021_MES_466494_2
8407/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹94,000
Yes
15 Nov 2021
4 Oct 2021
5 Nov 2021
7 Oct 2021
3 Nov 2021
9 Oct 2021
4 Oct 2021 - 7 Oct 2021
Amount
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 2000 amps for phases and for neutral including powder coated Siemens GREY painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at CASSIN No. 9 including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMING: a) ACB 1600Amps 4pole, 50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING: b) MCCB, 4 pole 800 Amps, 25KA,Thermal magnetic - 4Nos (Out going) c) MCCB, 4 pole 400 Amps, 36KA,Thermal magnetic - 2Nos (Out going) d) VAF meter class 1with CT's - 1 No e) indication lamps (R,Y,B) LED type - 1 set MAKE of ACB / MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 2000 amps for phases and for neutral including powder coated Siemens GREY painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at CASSIN No. 14 including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMING: a) ACB 1600Amps 4pole, 50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING: b) MCCB, 4 pole 800 Amps, 25KA,Thermal magnetic - 4Nos (Out going) c) MCCB, 4 pole 400 Amps, 36KA,Thermal magnetic - 2Nos (Out going) d) VAF meter class 1with CT's - 1 No e) indication lamps (R,Y,B) LED type - 1 set MAKE of ACB /MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 2000 amps for phases and for neutral including powder coated Siemens GREY painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels, cable termination,cable gland etc complete at CASSIN No. 16 including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMING: a) ACB 1600Amps 4pole,50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING: b) MCCB, 4 pole 800 Amps, 25KA,Thermal magnetic - 4Nos (Out going) c) MCCB, 4 pole 800 Amps, 36KA,Thermal magnetic - 4Nos (Out going) 60HZ d) VAF meter class 1with CT's - 1 No e) indication lamps (R,Y,B) LED type - 1 set MAKE of ACB/ MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 2000 amps for phases and for neutral including powder coated Siemens GREY painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination, cable gland etc complete at CASSIN No. 12 including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMING: a) ACB 1600Amps 4pole, 50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING: b) MCCB, 4 pole 800 Amps, 25KA,Thermal magnetic - 4Nos (Out going) c) MCCB, 4 pole 400 Amps, 36KA,Thermal magnetic - 2Nos (Out going) d) VAF meter class 1with CT's - 1 No e) indication lamps (R,Y,B) LED type - 1 set Make of ACB /MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 2000 amps for phases and for neutral including powder coated Siemens GREY painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at CASSIN No. 5 including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMING: a) ACB 1600Amps 4pole,50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING: b) MCCB, 4 pole 800 Amps,25KA,Thermal magnetic - 4Nos (Out going) c) MCCB, 4 pole 400 Amps,36KA,Thermal magnetic - 2Nos (Out going) d) VAF meter class 1with CT's - 1 No e) indication lamps (R,Y,B) LED type - 1 set MAKE of ACB/ MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 2000 amps for phases and for neutral including powder coated Siemens GREY painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels, cable termination,cable gland etc complete at CASSIN No. 17 including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMING: a) ACB 1600Amps 4pole, 50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING: b) MCCB, 4 pole 800 Amps, 25KA,Thermal magnetic - 4Nos (Out going) c) MCCB, 4 pole 400 Amps, 36KA,Thermal magnetic - 2Nos (Out going) d) VAF meter class 1with CT's - 1 No e) indication lamps (R,Y,B) LED type - 1 set MAKE of ACB/ MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, out door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical COPPER bus bar of capacity 5000 amps for phases and for neutral including powder coated Siemens GREY painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels, cable termination,cable gland etc complete at CASSIN No. 15 including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMING: a) Enclosure for ACB 4000Amps 4pole, 50 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING: b) Enclosure for ACB, 4 pole 800 Amps, 25KA,Thermal magnetic - 6Nos (Out going) c) VAF meter class 1with CT's - 1 No d) indication lamps (R,Y,B) LED type - 1 set MAKE of ACB/MCCB : Schinder/ Legrand/Seimens/L & T NOTE: ACB 4000A and 800A 4 Pole will be fixed by the contractor and the same shall be paid and meaured for seperately under item no. 8 and 9.
S & F ACB, 415 volts, four pole of cap 4000 Amps, 50 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - L & T cat part No SL96075 or equivalent in siemens/Schneider/Legrand
S & F ACB, 415 volts, four pole of cap 800 Amps, 50 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - L & T cat part No SL96075 or equivalent in siemens/Schneider/Legrand Note for item no. 1 to 7: All panels must be equipped with earth leakage relay and SCADA compatible Note for item no. 8 to 9 : LT panel will be fabricated having proper enclosure for ACB and the ACB mentioned in item no. 8 and 9 will be fixed by the contarctor including inter connection of CT's and rate for same deeemed to be included in item no. 8 and 9
Supply and fix vable jointing STRAIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 120 to 185 sqmm 3½ core complete all as specified and directed. Make : Rychem/3M
Supply and fix vable jointing STRAIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 240 to 400 sqmm 3½ core complete all as specified and directed. Make :Rychem/3M
Supply and fix vable jointing STRAIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 95 to 120 sqmm 3½ core complete all as specified and directed. Make :Rychem/3M
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240sq mm 3½ core, laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Make : Gloster/Polycab/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400sq mm 3½ core laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Make : Gloster/Polycab/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
M/S SOMANATH ENTERPRISES
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .