Tender Value
₹43.4 L
EMD Value
₹86,800
Closing Date
26 Jun 2024, 6:00 pmClosed
Garrison Engineer Chandimandir
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-07/2024-2025 SPL REPAIR TO RX HALL AND PROVN OF FALSE CEILING AN CAR PARKING SHED UNDER AGE B/R I AT CHANDIMANDIR
2024_MES_656513_1
GE/CHM-07/2024-2025
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹86,800
Yes
6 Nov 2024
29 May 2024
29 Jun 2024
29 May 2024
26 Jun 2024
12 Jun 2024
Amount
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, all as specified and directed.
Taking down chowkhats or frame n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed.
Taking down chowkhats or frame exceeding 1.5 Square Metre but not exceeding 4 Square Metre each with shutter(s) (without taking off shutters from the frame), complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each, and removal from site complete all as specified & directed.
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators, three track sliding window chowkhat section and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete all as specified and directed.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors/window/ventilators /partitions, (Sliding / openable) including joinging cleats, glazing clips, rubber neoprene beading, powder coated aluminim snap beading, screws, 02 Nos Handle, tower bolt, sliding door bolt etc. complete all as specified and directed Note : (i) Minimum thickness of power coating shall not be less than 50 micron. (ii) Weight of aluminum section only shall be measuerd and paid. (iii) Aluminum doors/windows /ventilators to be fixed to jambs with chromium plated screws . (iv) The rate shall be inclusive of neoprene beadings, snap beading, screws etc and in case of sliding shutters locking arrangement and rollers in sliding shutters. Weight of fitting fixtures will not be measured for arriving the weight of aluminum section. (v) Glass /wooden panel/ACP sheet shall be measured and paid separately under respective items. (vi) Design as directed by Engineer in charge.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed.
Brick work with sub class ‘B’ bricks , old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed.
Door closer hydraulically regulated of aluminium extruded section, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, complete all as specified and directed.
Supply only 5.00mm thick ordinary quality tinted glass, fixed to aluminum frame work in panels exc 0.5 Sqm in each pane, complete all as specified & directed.
3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading) in square n.exc 0.5 Sqm in each panes complete all as specified and directed.
Galvanized MS wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide, zinc chrome complete all as specified and directed.
Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar including removal of any existing treatment complete all as specified & directed.
PCC 1:3:6 type C-1 (using 20m graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement, including demolition of exisiting PCC complete all as specified and directed.
3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gms/sqm) laid over a coat of oil bound bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc having 75mm side lap joint and 100m end lap joint after preparing the surface as per standard practice and as per manufacturer instructions including dismantling of existing felt /treatment, complete all as specified & directed.
Rendering 15mm thick (average thickness) plaster in cement mortar 1:4 on concrete roof/ wall surfaces including flashings and junction of parapets etc , finishing the surface even and fair without using extra cement all as specified and directed by Engineer-in-charge.
40mm thick brick tiles over and including 15mm thick Cement mortar 1:4 joints, grouted & pointed flush as the work proceeds mixed with crude oil 5% by wt of cement complete all as specified and directed.
All as per item No 19 here-in-before but except tiles.
PCC 1:2:4 type B-0 (12.5 mm graded stone aggs) as in roof padding, roof kerbs rounded or chamfered on edges complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Vitrified ceramic tiles 8-10mm thick Light shade (square / rectangular) polished, area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over a 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed
Glazed ceramic coloured tiles of size 300mm x 450mm x 7mm thick as in dado, set and jointed in neat cement slurry and grouted in white cement complete as on vertical surfaces over and including 10 mm thick bedding layer in CM 1:4 complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in CM 1:6, complete all as specified and directed.
25mm thick Plain cement concrete 1:2:4 type B-0 using 12.5mm graded aggregate as in sub base complete all as specified & directed.
Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. at the places out side the premises complete all as specified and directed.
Rendering 15mm thick plaster in cement mortar 1:4 on brick or concrete surface of roof with mixing of WPC, finished even and fair without using extra cement complete all as specified and directed by Engineer-in-charge. Note :- WPC will be measured & paid separately as supply only).
Rendering 15mm thick in Cement and Sand mortar 1:4 over fair faces of brick / concrete ,finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 15mm thick in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement in patches complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over and including a coat of primer complete all as specified and directed.
Preparation of old surfaces of walls and applying two coats of oil bound distemper, complete all as specified and directed
4mm thick False ceiling fibre cement board, white in colour , 595mm x 595mm in size, fire and moisture resistance, fixed with and including standard GI snap grid framing (Powder coated) and suspended not exceeding 900mm below from ceiling with 3mm dia wire including clips and misc fittings etc in pattern as approved by GE, (size of panel shall be of 605 x 605mm and GI snap grid framing shall be of 1mm thick standard section i.e. channels, angles, tee etc) fixe in repair complete all as specified and directed.
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre fixed as in repair complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 20 cm deep and getting out in hard/dense soil, complete all as specified and directed.
Excavation in post holes (or similar hole) each in hard and dense soil n.exc 0.50 cu m getting out and removing surplus spoil at a distance not exc 50 metre and making good surfaces complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation for fencing posts complete all as specified & directed.
Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 t complete all as specified & directed by Engineer-in-Charge
Pre-painted galvalume aluminium zinc (AZ-70) coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc complete all as specified & directed by Engineer-in-charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
Concrete interlocking pre polished paver block, with grey cement and pigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade laid over and including 25mm thick sand cushioning, complete all as specified and directed
Concrete interlocking pre polished paver block, with grey cement and pigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade laid over and including 25mm thick sand cushioning, including dismantling of old tile complete all as specified and directed
Concrete interlocking pre polished paver block, with grey cement and pigment, design as approved, any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 Grade laid over and including 25mm thick sand cushioning, including dismantling of old tile complete all as specified and directed
Factory made coloured chequered cement concrete tiles 300mm x 300mm x 22-25mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 20mm thick screed bed in cement mortar 1:6, including dismantling of old tile complete all as specified and directed
Plain cement concrete type C-1, 1:3:6 using (20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, side kerbs, ramp, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed.
Welding in repair exc 2.5cm but n.exc 5cm thickness of metal to be welded exc 6mm but n.ec 9mm, welded with flats pieces, with adjoining agnles/ tubular section complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise complete all as specified and directed.
Supply only integral water proofing compound (ISI Marked) complete all as specified & directed.
Steel windows , ventilator fixed type with glazing bars, including one shop coat of red oxide zinc chrome primer complete all as specified & directed.
15mm dia GI tubing medium grade with all fittings , fixed into walls, ceiling or laid under floors and taking down existing tubing, complete all as specified and directed.
20mm dia GI tubing medium grade with all fittings , fixed into walls, ceiling or laid under floors and taking down existing tubing, complete all as specified and directed.
Bib taps brass, with wall flange, chromium plated, cast copper alloy fancy type, short body, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed as in repairs, complete all as specified and directed.
Grating doom 140mm dia of PTMT (minimum weight 50gms) complete all as specified and directed.
Wash hand basin, vitreous china, flat back, white of size 550 x 400 mm with and including angle brackets fixed as in repair complete all as specified and directed.
Chromium plated hand jet (health faucet) for 15mm bore pipe with 100cm long flexible tube, including fixing of hook on wall, fixed in repairs, all as specified.
Brass, chromium plated, tubular towel rail 20 mm dia. ‘D’ type, 60 cm long between flanges including brackets, fixed as in repair complete all as specified and directed.
Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), complete all as specified and directed.
Vitreous china wash down single piece EWC water closet pan of size 715 x 335 x 715 mm, white in colour alongwith cistern (Pedestal pattern) white (with all fitting) including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, etc fixed as in repairs complete all as specified & directed.
vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) fixed as in repair complete all as specified and directed.
15mm dia PVC connection with PTMT nut, of length 450mm, fixed as in repairs, complete all as specified and directed.
Central hole Basin Mixer, without popup waste system , cast copper alloy, chromium plated, screwed for iron pipe or for union, suitable for 15mm bore pipe, fixed in repairs, complete all as specified and directed.
15mm bore pillar tap, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe, fixed in repair, complete all as specified and directed.
PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed as in repair complete all as specified and directed.
110 mm bore PVC (SWR) bends of any radius complete, fixed as in repair all as specified and directed.
4mm thick aluminium composite panel sheet (ACP) fixed with aluminium anodised beading and rubber packing with all the clips and fittings colour as approved by Engr In Charge complete all as specified and directed.
Hard core of broken stone or boulders of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified & directed.
Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socket or power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete all as specified and directed.
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including provn of new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note for serial item No 72 to 75: Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.
All as per serial item 72 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed
All as per serial item 72 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 72 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed.
Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed.
Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose combined two module (ISI marked), complete all as specified & directed.
Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed.
Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed.
Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
Lamp holder, PVC/Polycarbonate type with back plate angular type fixed on wall suitable for batten fitting ,complete all as specified and directed.
LED lamp 9 watts, B-22 type (inverter bulb)complete all as specified .
Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, Complete all as specified and directed .
Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 100 to 125Amps & outgoing 4 way having IP 54 protection Complete all as specified and directed .
MCCB, 100 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed
MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 8 way SPN with 200 Amps busbar 240V completed all as specified and directed.
MCB, SPN , 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB ,SP , 240 volt, 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size , fixed as in repair complete all as specified and directed.
LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
LED lights fitting miror type 1x 10W, 220V, 2 ft inveter rechageable cool day light LED batten type inlcuding cpmmectomg up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed.
Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : - (i) For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cable shall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth (iii) PVC conduit & cutting chases will be measured and paid separtely
Sub main wiring with Four single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 32mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : - (i) For the purpose of measurement, 4 single core of 10 sqmm and one single core earth cable of 10 sqmm cable shall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth (iii) PVC conduit & cutting chases will be measured and paid separtely
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter
LED street light fitting 35 Watt 230 V AC outdoor type, white 6K with high pressure die cast aluminum housing and heat resistant complete with driver,including lamp bracket upto 1.5metre length of 40mm dia GI pipe (light grade) for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics, with IP 66 protection, complete all as specified and directed.
Round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light, complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
LED pannel surface mounted o size 2'x2', 36 watts cool day light fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed .
20 to 25 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified and directed .
32 to 40 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified and directed .
K L Kataria and Sons
m/s AR Construction co
MS R G ENTERPRISES
KUNDRA CONSTRUCTIONS
M/s Om parkash
Gunjan and Gunjan Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .