Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | ₹30.0 L Quoted ₹31.1 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹33.8 L+₹2.7 L (8.69%)Rejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | ₹33.8 L+₹2.7 L (8.69%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹34.9 L+₹3.8 L (12.3%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹34.9 L+₹3.8 L (12.3%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹38.1 L+₹7.0 L (22.4%)Rejected-Finance 3 224 RUI KI MANDI SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | ₹38.1 L+₹7.0 L (22.4%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹38.5 L+₹7.4 L (23.9%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | ₹38.5 L+₹7.4 L (23.9%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
20 Nov 2024, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
REPAIR AND REPLACEMENT OF INTERNAL ELECTRIFICATION, LED LIGHT, CONDUCTOR AND ALLIED WORK AT 6 PARA, 5 PARA, 23 PARA, 50 (I) PARA BDE, NCC BN, OTM ACCN, 509 ABW, AATS, 411 ENGR REGT ABD 801 TA UNDER GE (E) AGRA
2024_MES_681752_1
9708/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹1 L
Yes
21 Jan 2025
30 Oct 2024
27 Nov 2024
30 Oct 2024
20 Nov 2024
13 Nov 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete and all as specified and removing from site.
M&L for Point wiring complete with PVC insulated and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, MS sunken boxes duly painted with one coat of red oxide and one coat of black paint not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. (a) One light/Fan/Exhaust Fan point controlled by one switch.
All as per item No 2 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board.
All as per item No 2 above but one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches.
All as per item No 2 above but One Bell/Buzzer point controlled by one push button on same board with other switches or independent.
All as per item No 2 above but One light point controlled by two 2 way switches.
All as per item No 2 here in before but with cable size FRLSH cable 4 Sq mm for one AC socket out let/ 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm all as specified and directed
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FRLSH PVC insulated unsheathed cable with proper colour coding drawn in existing PVC concealed conduit with all accessories and FRLSH PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, including cutting and chasing of wall surface for sunken box and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. One light /fan/Exhaust Fan point controlled by one switch
All as per item No 8 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board.
All as per item No 8 above but one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches.
All as per item No 8 above but One Bell/Buzzer point controlled by one push button on same board with other switches or independent.
All as per item No 8 above but One light point controlled by two 2 way switches.
All as per item No 8 here in before but with cable size FRLSH cable 4 Sq mm for one AC socket out let/ 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm all as specified and directed
Supply and fixing switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fixing Switch piano flush button single pole one way 15 amps 240 Volts with polycarbonate body complete all as specified and directed.
Supply and fixing Switch piano flush button single pole two way 6 amps 240 Volts with polycarbonate body complete all as specified and directed.
Supply and fixing socket 5 amps 3 pin flush type, 240 volts. with polycarbonate body com-plete all as specified and directed.
Supply and fixing socket outlet, 6 pin 5 and 15 amps multipurpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
Supply and fixing Bell push, flush type, 5 amp, complete all as specified and directed.
Supply and fixing in repair call bell, Ding dong type, 230 volts AC single pole complete all as directed.
S & F in repair ceiling rose, 3 phase/PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals all as specified and directed.
S & F in repair stepped type electronic fan regulator switch/socket type ISI marked on the existing phenolic laminated sheet etc. as required, complete all as specified and directed.
S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 feet 20W) luminaire lumen >2000 lm, system efficiency of >100 lumens /W, with Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >100 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
Supply and fixing in repair LED luminaire 595 mm x 595 mm, 36 watt, 220 V AC, 6500 K surface/ recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting complete all as specified and directed.
Supply and fixing in replacement LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 25 mm dia GI light grade pipe, 1.00 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting and writing the date of fixing on security light with permt marker complete all as specified and directed. Note:-The period of defects liability shall be 02 Years from the date of installation of security light.
M&L in repair for Submain wiring with two single core FRLSH 4 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified. Note:- Two single core FRLSH 4 sqmm copper conductor, one run PVC conduit and one run of FRLSH 4 sqmm earth wire shall be considered & measured as one unit.
M & L in repair Submain wiring with two single core FRLSH 6 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connec-tion to earth dolly complete all as specified Note:- Two single core FRLSH 6 sqmm copper conductor, one run PVC conduit and one run of FRLSH 6 sqmm earth wire shall be considered & measured as one unit.
M & L in repair Submain wiring with two single core FRLSH 10 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 10 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connec-tion to earth dolly complete all as specified Note:- Two single core FRLSH 10 sqmm copper conductor, one run PVC conduit and one run of FRLSH 10 sqmm earth wire shall be considered & measured as one unit.
Supply and fixing in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, complete all as specified and directed.
S& F in repair sheet metal enclosure Vertical TPN DB 4 Way double door As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 earthbar and Cable ties for Cable manage-ment, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for easy of installation, Prefitted masking sheet, Reversible Door for IP 54 DB's, suitable for 160 Amp MCCB as incomer and SP/TP MCB's as outgoing including taking down old unsv MCB DB and MCBs complete all as specified and directed.
Fixing only in repair MCB DB triple pole with neutral 12 way, sheet metal enclosure double door type, 415 Volts AC, complete all as specified and directed. Note:- MCB TPN DB 12 way will be issued under Sch 'B' free for fixing .
Fixing only in repair MCB DB triple pole with neutral 8 way, sheet metal enclosure double door type, 415 Volts AC, complete all as specified and directed. Note:- MCB TPN DB 8 way will be issued under Sch 'B' free for fixing .
Fixing only in repair MCB DB triple pole with neutral 4 way, sheet metal enclosure double door type, 415 Volts AC, complete all as specified and directed. Note:- MCB TPN DB 12 way will be issued under Sch 'B' free for fixing .
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 4 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 8 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with appropriate size bus bar and common neutral link all en-closed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 12 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
Supply and fixing in repair MCB TPN 40-100 Amp rating 415V, 10KA 'C' curve and current carrying ca-pacity in the MCB DB complete with connection complete all as specified and directed.
Supply and fixing in repair MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection complete all as specified and directed.
Supply and fixing in repair MCB SPN 40-63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection complete all as specified and directed.
Supply and fixing in repair one way sheet metal enclosure suitable for MCCB, 4 pole, 160 Amps, As per IEC 61439-3 complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole, 160 Amps, 50 Hz, Icu=25 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 80% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , con-nected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanised iron strip 25x4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering, GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply and fix air terminal single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed.
M & L for test point terminal block made of gun metal or phosphoras bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long n.exc height head screw complete all s specified and directed
S & F aluminium strip 25x3.15 mm with saddles and fixing screw etc for roof and down conductors and above ground complete all as specified and directed.
M & L for Pre-cast cement concrete block masonary with solid blocks exc 30 cm in width and setting in mortor complete type B-1, 1:2:4 (20 mm graded aggregated) for fixing GI pipe for air termination rods) complete all as specified and directed.
Supply and fixing GI Tubes, 'Medium grade' 40mm dia complete to walls and ceilings complete all as specified and directed.
S&F porcelain insulator of required size not exceeding 10cm long with two Nos hole each on both end for fixing properly with nuts and bolts on wall of building for separated to lightening conductor or earthing strip from building all as required at site complete all as specified and directed. Note:- The distance between two insulators fixed on wall not more than 1 Mtr length complete all as specified and directed.
Supply and fixing in repair switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fixing in repair Switch piano flush button single pole one way 15 amps 240 Volts with polycarbonate body complete all as specified and directed.
Supply and fixing in repair socket 5 amps 3 pin flush type, 240 volts. with polycarbonate body com-plete all as specified and directed.
Supply and fixing in repair socket outlet, 6 pin 5 and 15 amps multipurpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
Supply and fixing in repair Switch socket combination 2 in 1, 5 Amp flush type, 230 volts with polycarbonate body complete all as specified and directed
Supply and fixing in repair Switch socket combination 2 in 1, 16 Amp flush type, 230 volts with polycarbonate body complete all as specified and directed
S&F in repair of sunk in cast iron/Pressed steel terminal box of size 5"x 5", 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint outside/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications, complete all as specified and directed.
S&F in repair of sunk in cast iron/Pressed steel terminal box of size 7"x 5", 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint outside/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications, complete all as specified and directed.
S&F in repair of sunk in cast iron/Pressed steel terminal box of size 8"x 10", 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint outside/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications, complete all as specified and directed.
Supply and fix in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp.
Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLSH PVC insulated and unsheathed,multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size MS Sunken Box with 3 mm thick hylam sheet/PVC box for mounting switches, regulator including FRLSH multi-strand PVC insulated unsheathed copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following : - (a) One light /fan point controlled by one switch.
All as per item No 62.00 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board.
All as per item No 62.00 here in before but one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches.
All as per item No 62.00 here in before but One Bell/Buzzer point controlled by one push button on same board with other switches or independent.
All as per item No 62.00 here in before but with cable size FRLSH cable 4 Sq mm for one AC socket out let/ 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm all as specified and directed
Supply and fixing MCB DB triple pole with neutral sheet metal enclosure double door type, 415 Volts AC, with appropriate size bus bar plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCBs and with enclo-sure blank plates for unused way suitable for 4 way ISI marked including taking down old unsv MCB DB and MCBs complete all as specified and directed.
Supply and fixing in repair modular switch single pole, 6 Amps 1 module.
Supply and fixing in repair modular switch piano flush type 16 Amps single pole one way, one module.
Supply and fixing in repair modular socket outlet 2/3 pin 6 Amps combined 2 module.
Supply and fixing in repair modular socket multipurpose 3 pin 6/16 Amps combined 2 module.
Supply and fixing in repair Modular Bell push 6A 1 module
Supply and fixing in repair Fan step regulator, 120W - 2 module
S & F in repair plug top 3 pin 16 Amps ISI Marked as specified and as directed.
Supply only metal clad socket industrial 2pin & earth, 20A, 230V complete suitable for AC Box.
Supply only metal clad plug top industrial 2 pin & earth, 20A, 230V complete suitable for AC Box.
SIYA ASSOCIATES (BID ID -3168000)
S S TRADERS (BID ID -3170463)
M/s United Engineers (BID ID -3167763)
M/S SHARADA ASOCIATE (BID ID -3170439)
M/S R.S. CONTRACTOR & SUPPLIER (BID ID -3166574)
M/S OMKAR SINGH YADAV (BID ID -3169384)
Allied Builders (BID ID -3170111)
Mahendra Enterprises (BID ID -3170147)
Unnati Engineers (BID ID -3170407)
M/S NAVIN & ASSOCIATES (BID ID -3169904)
3Krishna Enterprises (BID ID -3169941)
N.K. ENTERPRISES (BID ID -3170268)
aman construction & general suppliers (BID ID -3170343)
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .