EE, E400KV SUB-STATION DIVISION, MORADABAD
Electy. 400 KV Sub-Station Campus Delhi Road, Moradabad
COMPLETE OVERHAULING AND TESTING HEALTH CHECK UP OF 400 KV PNEUMATIC TYPE CIRCUIT BREAKER INSTALLED AT 400 KV SUB STATION MORADABAD
2024_UPTCL_919252_5
E-TENDER NO. 01/2024-2025
Open Tender
Electrical Works
Fixed-rate
60 days
MORADABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE, E400KV SUB-STATION DIVISION, MORADABAD
₹2,000
30 May 2024
24 May 2024
30 May 2024
24 May 2024
30 May 2024
24 May 2024
Amount
The following works are to be carried out at 400KV S/S, Moradabad.
Overhauling of pneumatic mechanism assembly of 400 KV SF – 6 Circuit breaker of 500 MVA ICT-I at 400 KV Sub-Station, Moradabad. In all three Poles mechanism assembly. -Dismantling of control valve assembly along with copper band pipe from breaker, -Complete dismantling of Control Valve assembly by cleaning of its parts by cleaning agent, replacement of control valve, O-Ring P 80,Cap seal assembly, C&D roller & refitting the control valve with its proper adjustment. -Dismantling of main closing spring, cleaning of piston drum, checking of shock absorber lubrication. -Dismantling of close/trip coil assembly, clean its plunger, lubricant and adjustment of its air gap. -Dismantling of horizontal rod, pins and its linkage cleaning & lubrication. -Checking of all air pipe lines and accessories. -Replacement of all O-ring P 8 from pipeline and replacement of NRV safety valve if required. -Checking and tightening of all electrical connection in the marshelling box. -Refixing of pneumatic mechanism assembly with proper adjustment. -Checking Satisfactory close/trip operation of the breaker both by local and remote. Determine Operating times of following Operation- Closing Opening Operations. Contact Timing, Contact resistance. Pole Discrepancy time operation. Note- For the above work all the T&P Items, man & Consumable Material, Crane (If required) are to be Provided by the Contractor. After Completion of overhauling work of C.B. the service engineer is provide warranty of any leakage for next one year. And also provide C.B. time testing report at the contractor letter head. Circuit Breaker Analyzer Kit Shall be Provided by Contractor
SATKAR TRADERS
SWITCHGEAR AND TRANSFORMER CARE CENTRE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .