Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹75 L
EMD Value
₹1.5 L
Closing Date
30 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
DAY TO DAY REPAIR/MAINT OF INTERNAL ELECTRIC SUPPLY, FITTING/FIXTURE PLUMBING, FLOORING, PLASTRING, TILING JOINERY, BOUNDRY WALL FENCING, APPROCH PATH, SEWAGE SYSTEM, DRAIN AND B/R WORK IN OTM AND MD ACCN AT MIL STN UNDER GE (EAST) LUCKNOW.
2025_MES_731902_1
CWE/LKO/E/T-49 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EAST LUCKNOW
₹1.5 L
Yes
20 Sept 2025
20 Sept 2025
6 Nov 2025
20 Sept 2025
30 Oct 2025
11 Oct 2025
20 Sept 2025 - 11 Oct 2025
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete, all as specified.
M&L for 40mm thick PCC 1:2:4, type B1 using 20mm graded crushed stone aggregate as in flooring, finished even and smooth without using extra cement, complete, all as specified & directed.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, complete all as specified.
M&L for cement concrete 1:3:6 type C2 , 75 mm thick as in plinth protection smooth without using extra cement incl cutting joints at every 3 m & at corner, Joints to be filled with mastic bituminous.
M&L for PCC (1:2:4) Type B-1, using 20 mm graded stone aggregate as in Coping
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, all as directed.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement, complete, all as specified.
M&L for 15mm thick on fair faces of concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound finished even and smooth without using extra cement . (Liquid water proofing compound to be measured paid separately) complete all as specified and directed.
Supply only Liquid water proofing compound complete all as spesified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on stone masonry surfaces or surfaces other than fair face of brick work of walls, finished even & smooth without using extra cement, complete, all as specified
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint complete all as specified.
M&L for Preparation of new or previously undercoated surface of ceiling and applying three coats of white wash on ceiling all as specified and directed.
M&L for Preparation of new plastered surface of wall and applying two coats of OBD over a coat of primer on wall all as specified and directed.
M&L for Preparation of old surface of ceiling and applying one coat of white wash on ceiling all as specified and directed.
M&L for Preparation of old surfaces of wall & applying one coat of cement base paint of approved shade/tint complete all as specified.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efforescent salts, trading oil, greasy sopts etc and preparation of plastered surfaces and applying two coat of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, over a coat of 2mm thick wall care putty & primer of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over Complete all as specified and directed
Taking down chowkhat frame with shutter (without taking out shutter from the frame) n exc 1.50 Sqm and removing from sites complete all as specified and directed.
Taking down chawkhat frame with shutter (without taking out shutter from the frame) exc 1.50 Sqm but n. exc 4 sqm each and removing from site complete all as specified and directed.
S&F 75x50mm single rebated factory made 100% solid WPC (Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with dencity not less then 780kg /Cum all as specified and directed.
S&F 65x100 mm single rebated factory made 100% solid WPC (Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with dencity not less then 780kg /Cum all as specified and directed.
S&F 65x125 mm double rebated factory made 100% solid WPC (Wood Polymer Composit) door frame from 100% lead free ( Single & extruded process) material with dencity not less then 780kg /Cum all as specified and directed.
S&F Factory made 30 mm thick 100% solid WPC (Wood Polymer Composite) solid prelem both side 14 micron Flush door shutter wit 10mm deep CNC moulding design of required size comprising of virgin PVC resin of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 650 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S&F 30mm thick factory made solid WPC (Wood plastic composit) moulded glzed door shuter with wire mesh in 08 number of division with brown wood grain texture including SS wire mesh (G-304) 0.36 mm minimum dia of wire and average width of aperature 1.4mm with XPM Aluminium alloy wire cloth of wire shall to be fixed with 15x15 square tube in side rails with screwing 8x28 heat metel zink coated screws can be remove of fix again after changing of wire mesh needed. The density not less then 650kg /Cum shall be as per manufacture instruction complete all as specified and as directed
S&F powder coated aluminium anodised frame/chowkat of Alu door fixed with rawal plug and screw or wire expansion hold fasteners
S&F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F for powder coated aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S&F powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge
S&F 12 mm thick toughened glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required and pivot at top fancy type SS handle of size not less than 300 mm on both sides of shutter with suitable locking arrangement and frosted film with logo & letter for glass door all necessary fitting complete all as specified and directed.
M&L as in repair for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty, fixed in repairs, with & including replacement of floor tiles if any broken during repair work and making good disturbed surfaces matching to the existing surfaces complete all as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apeerture 1.40 mm and fixed with tinned tacks, or galvanised wire staples, all as directed.
All as per item No 206 but of size 5'' x 5''.
S&F butt hinges of size 100mm medium weight, stainless steel ISI marked complete all as specified.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section all as specified.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section all as specified.
S&F 150 mm size aluminium alloy handles, fabricated type, extruded section.
S&F in repair 100 mm butt hinges extruded brass,with mild steel hing pin ,bright polished and fixed, type B-11
S&F in repair 75mm butt hinges extruded brass,with mild steel hing pin ,bright polished and fixed, type B-12
S&F in repair 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified.
S&F in repair 75mm hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws
S&F in repairs aluminium extruded section body door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg. and fixed.
S&F in repairs 150mm long fancy stainless steel handle for cupboard & wardrobe shutter complete all as specified and as directed by Engr-in-charge
S&F in repairs 200mm long fancy stainless steel handle for wardrobe shutter complete all as specified and as directed by Engr-in-charge
S&F in repairs 100mm brass Mortice lock (Godrej pattern), vertical type, 4-lever complete all as specified and as directed.
M&L 18/19 mm thick prelaminated particle board, interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work fixed as in repairs.
S&F 18 mm thick solid WPC board one side prelaminated decoratiove teak face and other side white and balancing as in kitchen shelf, shutters etc including chawkats and all fitting accessories etc including dismantling, complete all as specified and directed
S&F 18/19mm thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work
S&F 0.9mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions
S&F continuous (piano) hinges, mild steel, bright finish or electro galvanized width of flaps 30mm (when open) fixed with CP steel screws.
S&F floor door stopper as in repair of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified.
S&F in repair Hat pegs, solid body,125mm to 175 mm brass fancy type, all as specified fixed
S&F as in repair mild steel helical door spring 150mm ordinary rat tail rod pattern spring including roller and roller plate including welding if required complete all as specified.
S&F in repairs 50mm dia, polished, hard wood knobs fixed with screw
S&F in repairs Ball catches with 150 mm long & 8mm dia steel ball, and brass body and striking plate including letting in and fixed
S&F 125 mm dia CP brass shower rose incl shower arms with or without swivel joints any size including fixing to steel pipe or union add if fixed in repair all as specified and directed.
S&F as in repair CP soap dish any type fixed to plugs with chromium plated brass screws all as specified.
S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers complete all as specified and directed.
S&F in repair for three layer rotational moulded polyethylene water storage tank cylindrical hoisted & fixed in position incl dismantiling water tank complete all as specifed capacity 500 ltrs.
S&F for in repair three layer rotational moulded polyethylene water storage tank cylindrical hoisted & fixed in position incl dismantiling water tank complete all as specifed capacity 1000 ltrs.
S&F in repair 25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density Plastic ball Screwed for iron pipe and fixed (Minimum weight 455 gms. Make Prayag/Polytuff
S&F in repair 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density Plastic ball Screwed for iron pipe and fixed (Minimum weight 210 gms. Make Prayag/Polytuff
S&F in repair 15 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density Plastic ball Screwed for iron pipe and fixed (Minimum weight 142 gms. Make Prayag/Polytuff
Cleaning and removing all scale and dirt etc from tank and mouth of circulating pipe of capacity exc 250 n.exc 500 ltr complete all as specified.
Cleaning and removing all scale and dirt etc from tank and mouth of circulating pipe of capacity exc 500 n.exc 1000 ltr complete all as specified.
S&F stainless steel Kitchen plate rack of overall minimum size 750 mm x 900 mm and 250 mm deep, with partitions for small/large plates etc made out of stainless steel 1 mm thick fixed with rawl plug and CP steel screws complete, all as directed.
S&F sink made of stainless steel 1mm thick for kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to dwarf wall, connecting union to pipe, overall minimum size 495mm x 420mm bowl size 410mm x 330mm x 160mm including 32mm dia waste pipe of polythelene of low or high density, 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete, including taking down old unserviceable
S&F kitchen sink with drainage board made of stainless steel 1mm for kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brakkets, bedding in cement mortar on to dwarf wall, conntecting union to pipe, overall mimimum size 915mmx460mm with bowl size 410mmx330mmx160mm including 32mm dia waste pipe of polythelene of low or high density, 32mm bore chromium plated brass waster fitting with long screwed shanks and fly nuts, flage end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC
1:2:4 type B0, complete including taking down old unserviceable sink.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, all as specified and directed
M&L for machine cut kota stone slab flooring 18-20mm thick over cement screed bed 20 mm thick in CM 1:6, base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L Glazed ceramic tiles in vertical surfaces 600x300x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors including screed bed 15mm thick or beding layer for laying floor finishes CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match
S&F vitrified ceramic tiles dark/light shade digital tiles/(double charged), 10mm thick (square/ rectanglar) polished , exceeding 0..36 sqm of each tiles not exceeding 0.42 sqm, in floors etc. laid over 15mm thick screed bed 1:6 , set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specified.
Dismantling of stone slabs and tiles of any description or thickness in floors, platform, aprons etc laid bedded and pointed in any mortar
M&L, 20 mm thick granite (of any type and colour ) work (table rubbed and polished ) in steps, Jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust and admixture of pigment to match with shade of granite complete all as specified.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
Dismantling AC sheet (Corrugated, Semi Corrugated etc) as in roofs etc including ridges complete all as specified.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in room covering/cladding to wall, including ridge cover fixed with self tapping screws etc all as specifed.
Dismantling wrought iron or mild steel work of any description
S&F framed work as in doors or gates of angle or other section with gussset plates, rails, braces etc complete drilled for fixing steel sheetings or other coverings. Doors etc to be prepared for hanging or sliding with and including either hooks or hinges steel hanging door fittings ( exclusive of steel sheeting or other coverings running rails and guides) and hanging also fastening and fixing complete quality conforming to Fe-290W (Gde E-265) quality B complete all as specified.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified.
S&F mild steel rolled/tubular sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters , fixed with angle cleats or other connecting plates etc. conforming to Grade Fe 410W(Gde E-265 quality `B’ all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness including cover filltets complete all as specified
Providing and fixing of E-board 'Everest' or equivalent make 600 x 600 x 4mm thick white prelaminated sett embosed reinforced desigener (lake & HM as approved ceiling board/tiles at all height laid on Armstrong Hot dipped Galvanised imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work will comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers of GI wire 4mm dia to be fixed by approved rawl plugs, level and justers and screws etc.
S&F 5 mm thick hollow PVC Wall panlling heavy duty including PVC beading at corner and top & bottom of any design, fixed on wall as per manufacture instruction complete all as specified and directed.
Taking down rain water pipes ( any size or pattern) incl all fittings , shoes, bends, swan neck etc complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps complete all as specified and directed.
S&F of 110mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed.
S&F of 75mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed.
M&L for PVC (SWR) Gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal of 110mm bore single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and as directed.
S&F PVC (SWR) Junction Double, (Double T) equal or unequal of 110mm bore single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and as directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal of 75mm bore single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and as directed.
S&F PVC (SWR) Junction Double, (Double T) equal or unequal of 75mm bore single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and as directed.
S&F in repair vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified. Make- Parryware/Hindware.
S&F in repairs vitreous china wash hand basin, white, flat back of size 550x400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified.
S&F Vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe ). and trap including connection to drain (or out going pipe) and to flushing pipe anti sphonage pipe etc complete including flush pipes and all joints add if fixed in repairs.
S&F in repairs Plastic water closet seat cover coloured/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed.
S&F in repair 10 Litres capacity PVC valveless syphonic action type flushing cistern low level, white with inlet ball valve float and handle including brackets connection to pipes and fixing of lever if any joint between flushing pipe and socket of WC pan pre-made
S&F in repairs vitreous china urinal half stall type white excluding flushing cistern ,flush pipe and waste pipe
S&F in repairs glass corner shelf assembly consisting of 5.5mm thick sheet glass 250X250mm size fixed with chromium plated brackets as in repairs all as directed
S&F in repair glass self assembly con
sisting of 5.5 mm thick glass sheet glass self 12 Cm wide with CP bracket gaurd and railing 60 Cm long all as specified.
S&F in repair PVC floor trap plain with grating including jointing with solventt in run lead 75/100 mm out let complete all as specified.
S&F 15 mm bore GI tubing medium grade with all fittings and fixed complete to wall and ceiling or laid in floors including taking down
S&F 20 mm bore GI tubing medium grade with all fittings and fixed complete to wall and ceiling or laid in floors including taking down
S&F CP brass towel rails 20 mm dia and 600 mm long fixed as in repair incl chromium plated brass screw and wooden / cleats.
S&F in repairs PVC cabinet with mirror and door of size 560X410mm all as specified and directed.
S&F in repair health faucet for EWC CP hand hold with flexible pipe 1.5m long complete set all as specified. Make: Jaguar /ESS-ESS/Prayag
S&F in repair CP concealed stop cock/ angle valve for 15 mm bore pipe.
S&F in repai gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe 20mm borer.
Dewatering of soak well , septic tanks by using mechanical pump diesel driven with fuel operator and crew of water etc at site all as specified and directed by Engineer in charge.
S&F in replacement flexible LED strip uses high brightness yellow colour with electrinic driver all as specified and directed.
Cleaning of soak well, septic tanks by way of desludging foreign material manually/mechanically and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off outside of MOD premises (at the location notified by the local Municipal Corporation/ Cantt board as per rules of public health), including digging required nos of pits for depositing sludge and future capping the pit with the 25 cm thick layer of soil and sprinkling bleaching powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
Cleaning of blockage of 150mm bore sewer lines (i.e. branch sewer line, main sewer line) by way of cleaning desludging foreign material as well as roding of sewer line between successive manholes manually/mechanically or pumping out sewage from blocked line including desludging where required and ordered by Engineer-in-Charge and keeping sewer line functional from Ist manhole upto final drop as septic tank, soakage well all as specified and directed .
Cleaning of all manholes upto 1.5 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
Supply and fix LED tube light fittings 1200 mm, 10 W higher energy saving decorat
Cleaning of all manholes upto 3.00 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder ( including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
Cleaning of all blockages of Nahni traps/floor traps/bottle traps, blockages of WC's, upto 1st manhole/Gully Trap in shafts, vertical CI soil/waste pipe stacks, CI Tee/door bends etc & cleaning of drain pipes of any dia by rodding and removal of sludge/silt/liquid mud sand (in foul conditions) etc, out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board). To Maintain of internal & external sewage system in functional state at all the time by engaging/deploying minimum One Safaiwala alongwith one Helper from 0900 hours to 1700 hours at Complaint cell of AGE B/R-II area mentioned in the contract on daily basis, with manual/ pressure cleaning pump and flexible rods and other necessary equipments (as per rules of public health), complete all as specified and directed.
M&L for factory made RCC man hole cover /drain cover with cover frame comprising of 75mm thick cover, including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M-30 grade concrete by vibro compression process, medium duty confirming to IS-12592 including fixing on manhole, demolition of existing coverwith cover frame and removal of debris from site complete all as specified and directed. Note : The factory made RCC cover shall be ISI marked and as approved.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete .
M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius built in cm 1:4
Re- use of brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius built in cm 1:4
M&L Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
S&F for M.S framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged in to spikes, framed guard bars, barred iron doors and similar work complete all as specified
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, and removing surplus soil to a distance n exc 50m and making good surface in soft/loose soil
Dismantling fencing wire mesh, any type
S&F for mild steel work in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc,.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed .
S&F in repair galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts including securing or type at crossings with and provision of galvanised mild steel wire staples or steel pins, etc as directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire
Supply only chainlink MS galvanised chain link fencing any size mesh all as specified
S&F in repair Coloured Polycarbonate Sheets 6mm thick (multi wall) as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
M&L for cement concrete type C2, 1:3:6 using 40 mm graded stone aggregate as in embedding of fencing post etc,.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc.
ement concrete 1:5:10 type E-2 (40 mm graded aggregate) in foudations, filling and mass concrete complete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4 type B2 using 40 mm graded crsued stone aggregate as in PCC hard standing, finish the surfaces even and smooth without using extra cement (in panel necessary form work included) complete all as specified and directed.
Forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade 'A'
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 30mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand
S&F exterior tiles of superior quility 400x400x12MM thick of approved size/design/shade set and jointed in neat cement slurry & pointed in white or coloured cement to match as in floor over and including 20mm thick screed bed in cm 1:4 complete all as specified and directed.
M&L chequred cement concrete tiles 30 cm x 30 cm x 20 mm thick set and jointed and pointed in neat cement slurry with grey cement and pigment in floors including 20 mm screed bed in CM 1:6 complete all as specified.
M&L for PCC 1:3:6, type C-2 (40mm graded aggregate) as in foundation, sub base complete all as specified.
M&L sand filling under floors or in foundations including watering and consolidation
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection finished even and smooth using extra cement complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete
Demolition and breaking up drain pipes 150mm dia salt glazed stone ware AC or rein forced concrete pipe incl PCC haunching etc set in cement mortar including removal from site complete all as specified and directed by Engr-in-charge
Excavation in trenches not exc 1.5 m wide and not exc 1.5m depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Excavation in trenches exc 1.5m but & n.exc 3.0m depth for foundation, etc. or for shafts, wells, cesspits, manholes, etc. not exc 10 Sqm on plan and not exc 1.5 m depth & getting cut in soft/loose soil complete all as specified.
M&L for Cement concrete in foundations, filling and mass concrete type D2 1:4:8 (40mm graded aggregate) complete allas specified and directed by Engr-in-charge.
M&L for Salt glazed stoneware drain pipes 150mm grade ‘A’internal dia laid in trenches and jointed complete all as specified and directed by Engr-in-Charge.
M&L for 450 mm reinforced concrete pipes, class NP2, laid and jointed complete with collars including jointing with cement joints with PCC bed and haunching with PCC 1:4:8 type D-2 using 40mm graded stone aggregate for 450mm bore NP2 pipe line including excavation and earth work and returning, filling in trenches and removal of soil upto 1.5m, including taking up broken sewage pipe line , all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 for 150mm bore of pipe as concrete bed to drain pipes including packing under and haunchng against the sides of pipes after they are laid and tested complete all as specified and directed by Engr-in-Charge
Returning filling in trenches including spreading leveling, watering and well ramming in layer not exc 25 cm thick complete all as specified and directed.
Removing of excavated materials to a distance 1.5km and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching complete all as specified and directed.
M&L for PCC Type B0(1:2:4) using 12.5 mm graded stone aggregate) as in man hole, surface channel and drain complete including finished surface.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including form mould mitered or stopped ends complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed
M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6 to 8 mm dia and over cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for formwork to soffits of suspended slabs as similar work n.exc. 250mm thick on rough finished surface of concrete.
ive ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all
Supply and fix in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into existing T8 conventional fluorescent tube light fitting after changing the necessary electric connections as required at site complete all
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as
S & F, 450mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser all as specified and directed. Note for item No. 01 to 240 :- BOQ has been prepared by clubbing items for 03 jobs. There may be similar description/nature of items at more than one place. In case different rates are quoted for same work, lowest rate quoted for each item shall prevail and liable to be paid in bill. No claim shall be entertained at a later stage.
Note for item no-113,114 & 115 1.The cleaning shall be carried out with mechanized operation by means of diesel / electric operated vehicle mounted hydraulic operated high pressure suction -cum -jetting machines fitted with pump of required capacity and the sludge sucked out with Super Succer Machine of required capacity and sent to storage tanks for further disposal to the authorised disposal site land at any distance and without any additional cost. 2. The sludge deposited in sewage line shall be fully cleaned and disposed off the same outside the MOD land at any distance and without any additional cost , on the same day when it was taken out.The job shall be carried out with safety precaution equipment and with strict supervision . 3. During the mechaized operation , the service provider /Contractor shall be equiped with Gas monitor , nylon rope ladder , torch light and compressor blower etc along with the sewage cleaning truck mounted suction / jetting machine . 4. The unit rate quoted by the contractor shall interalia deemed into the cost of providing skilled driver and operator and supervising engineer including provision of water for jetting & removal of sludge /silt /liquid /mud & sand (in foul position )etc. 5. The contractor shall engage the above mentioned T & P and intimate to Enginner - In -Charge in writing with Machine No./ Vehicle No. etc for their record and prior approval . 6. A Register shall be maintained showing the Machine No /Vehicle No. and their deployment at site mentioning time and date duly sighned by concern JE , Engr -in- charge and contractor and the same register shall be produced while claiming the payment by the tenderer .
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.20 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete
Supply and fix switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete .
Supply and fix switch piano flush type, 06 Amp, single pole, two way, 230 volt complete.
Supply and fix bell push, flush type, 06 Amp, 230 volt.
Supply and fix socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt.
Supply and fix switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete.
Supply and fix ding dong bell, AC, 230 volt, single pole complete all
Supply and fix electronic ceiling fan regulator with rotary
step, two module, humfree, AC, 240 volt, 100 Watt and duly ISI marked complete.
Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting.
Supply and fix frame plate with match cover one module plate
Supply and fix frame plate with match cover two module all
Supply and fix frame plate with match cover three module all as specified and directed.
Supply and fix Modular switch one way 6A 230V AC 50 HZ SP one module
Supply and fix Modular switch one way 16A 230V AC 50 HZ SP one module all as specified.
Supply and fix Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified.
Supply and fix Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module all as specified.
Supply and fix fan regulator 2 module Modular type 230V AC 50 HZ SP complete all as specified.
Supply and fix in replacement of decorative wall mounting type LED light fitting, 1 x 10 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and fix in replacement of single side connection LED T8 tube light rod 18/20 Watt, 6500K of four feet long into and including LED tube rod light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete .
Supply and fix in replacement of LED security light fitting 45 watt, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete.
S&F in repair LED surface mounted Batten 20-22 watt, powder coated die cast / extruded aluminium Body (Thickness ≥ 1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED Driver & electrical circuitary), of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc as required with Minimum 5 year OEM warranty. System lumen efficacy 120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supplying and fixing in repairs LED bulkhead fitting 9 watt IP 66 & IK 09 with polycarbonate body duly prewired connection with 0.75 sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete
Renewal of decorative wall mounting type pre-wired LED light fitting, 1x15 watt, 230 V made of Polycarbonate body, shade, lamp holder, 10 watts LED lamp B22 CDL complete.
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete.
Supply and fix in replacement of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all.
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper b
us bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 12 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all
Supply and fix in replacement of MCB, SP, AC, 240 volt of 06 to 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fix in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all.
Note :- For item No- 117,118 & 119 1. The Nos of person indicated in above items as assumed by the department, shall remain present at the complaint cell of SDO Barabanki area mentioned in CA. Contractor may have to deploy more manpower in the particular area and deploy adequate sewage cleaning machinary/ equipments to clean the line and open blockages. Rates quoted shall be deemed to have considered in the items all such contingencies. 2. In case of non availability/ absence of any of minimum required man power, the recovery for the same shall be effected @ Rs 500.00 per day for the absence period proportionaly. 3. If necessiated by the Engr-in-charge/GE for work on Sunday/ holidays, the contractor shall provide tradesmen with helpers. 4. Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produced for verification at the time of payment of each RAR/Bill.
All as per serial item No 166 here-in-before but one bell point controlled by one bell push, 06 Amp.
All as per serial item No 166 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp.
All as per serial item No 166 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete.
Supply and fix only LED bulb 9 Watts suitable for B22 white in colour.
Supply only LED bulb 12 Watts suitable for B22 yellow in colour.
Supply only LED bulb 9 Watts suitable for E27 thread type yellow in colour.
S & F Laminated sheet cover hylam ISI marked 3mm thick including cutting of sheet for fixing switches/sockets as required at site incl suitable size screws - 04 Nos for fixing on existing MS sunken boxes complete all as specified and directed of size 8'' x 5'' .
S & F Laminated sheet cover hylam brand ISI marked 3mm thick round sheet for fixing on junction boxes as required at site incl suitable size screws - 01 Nos complete all as specified and directed .
S & F Replacement of unserviceable PVC Conduit 20mm, ISI marked, complete all
S & F Replacement of unserviceable wire of size 1.5 Sqmm with PVC insulated FRLS multistranded copper conductor for working Voltage 1100 Volts single core of 1.5 Sqmm .
S & F gang box suitable for 6 Amp Socket and 6 amp switch.
S & F gang box suitable for 16 Amp Socket and 16 amp switch.
All as per serial item No 166 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
All as per Serial Item No 166 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete.
All as per item No 206 but of size 7'' x 4''.
S & F enclosure suitable for MCB complete all
Repair/ replacememnt of Supply and fixing wall fan of 300 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 Cum/min with all accessories complete all as directed by Engineer - in - charge.
Repair/ replacememnt of Supply and fix PVC air freshner 250 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all.
Repair/ replacememnt of Supply and fix PVC air freshner 300 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all.
Rewinding of Ceiling/ Exhaust/ Cabin fans and pedestal fans comprising of followings: a) Rewinding of stator with supper enameled copper wire (gauge of wire shall be same as provided by the manufacturer) including varnishing the new winding wire with quick dry varnish properly. b) Replacement of defective worn out bush where required, (ball bearing, capacitor will be measured and paid separately). c) Oiling/greasing and reassembling the fans with new split pin, check nut, locking bolt, washer, holder clip and connector including providing new twisted twin core flexible copper cable of size 23/0.0076 of 1 Mtr length. d) Testing of repaired fan shall be carried out in the yard of AGE E/M (East) to the entire satisfaction of the Engr-in-Charge. Note: Rewinding shall be carried out in pump house, Painting of Fans deemed to be include in respective Item. 30.01 Ceiling fan of 1200 mm Sweep
M&L, replacement of ball bearing of size 6201/6202/6203 .
S&F, Capacitor 2.5 MFd for ceiling fan of any size and exhaust fan of size 300/230mm cabin fan any Sweep
S & F, 450mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser all as specified and directed.
S & F, 600mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser all as specified and directed.
Taking down the Geyser of any make and size horizontal or vertical from Site for repairs/overhauling/replacement of unserviceable parts including replacement of old nuts and bolts with washers heavy duty including disconnection of electric supply, water supply lines and refixing the the Geyser in the serviceable condition after assembling, testing and reconnecting the electric/ water supply line all as specified and directed. Note:- Replacement of unserviceable parts of old Geyser shall be measured and paid separately under respective item here in after except bolt, nuts and washers."
M &L Spray painting of fan with one coat of super enamel white paint (Berger/Asian/Nerolac) after cleaning of body and blades, down rods, with detergent powder and writing MES Nos with black paint at given site under SDO (MES) Barabanki area as directed (Note:- The work shall be carried out at site)
Supply and fix in replacement unserviceable heating element 2.0 KW of Geyser (ISI marked) for any make and type all as specified and directed.
Supply and fix in replacement thermostat(ISI Marked) suitable for any type, and capacity of geyser all.
Supply and fix in replacement unserviceable indicating lamps red and green colour for Geysers.
Supply and replacement of unserviceable door assembly ISI marked comprising of inlet and outlet thermostate, housing with gasket with bolts, nuts, washers, screws of packing suitable for any type and make of geyser.
M & L, repairng of leakage of inner copper/steel tank of any type /capacity and make of Geyser by brazing including necessary denting, etc
Supply and replacement of unserviceable plug top 3 pin 15 Amp all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
TenderET49Latest.pdf
Tender Documents • 1.36 MB
BOQ_819437.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .