Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹14.1 LAWARDED | AWARDED |
Tender Value
₹16.7 L
EMD Value
₹21,000
Closing Date
14 Mar 2025, 10:55 pmClosed
Public Works Department
Conversion of H.T. line to L.T line providing test report & getting approval from HESCOM authorities and laying cables for power supply to the executive engineer pwd division of the,circuit houses old ibs and other essential buildings at gadag. under head of account 2059-80-053-4-00-200 for FY 2024-25(RESERVED ST)
PWD/2024-25/EL/WORK_INDENT18481
PWD/2024-25/EL/WORK_INDENT18481
Reserved
Electrical
Electronic Documents, First(One Cover)
PWD Division Office Gadaga
₹500
₹21,000
7 Mar 2025
7 Mar 2025
13 Mar 2025
Conversion of H.T. line to L.T line providing test report & getting approval from HESCOM authorities and laying cables for power supply to the executive engineer pwd division of the,circuit houses old ibs and other essential buildings at gadag.
Supplying and Errection of RCC Pole- 9 Mtr Long. 145 Kg WL for street light(Dwg No. BESCOM/GM/QS&S/02Dated 24-11-2018) as per IS-785 ---- Work should be carried out as per the direction of engineer in...
PSCC Pole - 9 Mtr Long , 200 Kg WL (Dwg No. BESCOM/GM/QS&S/17-11-2018) as per ERC standard. ( Stud pole) ---- Work should be carried out as per the direction of engineer incharge of work.
Errection of RCC/ PSCC pole of 9 to 10 Mtr long in a pit of 1.80 Mtr depth. ---- Work should be carried out as per the direction of engineer incharge of work.
11 KV, Cross Arm with HT Top Support glass reinforced hot pressed SMC compound ---- Work should be carried out as per the direction of engineer incharge of work.
Fixing of cross Arm, single Top support, EG stirrup, Anticlimbing Device, Guy set, Gaurding etc., ( Fixing of HT/LT Single Top support. ---- Work should be carried out as per the direction of engineer...
Insulator as per IS-1445 for Ceremic, IS-7935 for GI Pin, IEC-61109 for Polymeric. Disc insulator 45 KN Porcelain. ---- Work should be carried out as per the direction of engineer incharge of work.
Cross Arms (MS & GI) as per IS-1977 : LT- 2 Pin Cross Arms - GI ---- Work should be carried out as per the direction of engineer incharge of work.
Fixing of cross Arm, single Top support, EG stirrup, Anticlimbing Device, Guy set, Gaurding etc., ( Fixing of 2 Pin cross Arm with insulator and Braces fixing) ---- Work should be carried out as per t...
Clapmps A Type (MS & GI) as per IS-1977 : PSCC Pole (200 Kg WL) Clamp GI ( Dwg No. BESCOM/GM/QS&S/31 Dtd: 24-11-2018) ---- Work should be carried out as per the direction of engineer incharge of work.
Supplying of spiral earth electrode ---- Work should be carried out as per the direction of engineer incharge of work.
Fixing of spiral earth electrode ---- Work should be carried out as per the direction of engineer incharge of work.
Supplying Double pole TC Set for Errection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977, For 100/300kVA 4/5 Star Rated Transformer on RCC Pole-9 Mtr Long, 300 Kg WL-GI ---- Work should b...
Errection of Double pole Transformer Structure Using 9 Mtr Long RCC (145Kg WL)/ PSCC (300 Kg WL ) Pole including fixing structure Materials, Errection of Poles etc., complete for mounting Transformer ...
Insulator as per IS-1445 for Ceremic, IS-7935 for GI Pin, IEC-61109 for Polymeric. Disc insulator 45 KN Porcelain. ---- Work should be carried out as per the direction of engineer incharge of work.
Fixing of Guyset with break insulator making use of 7/3.15 mm (7/10 SWG ) galvanised steel wire with turn buckle and anchoring rrangement as per approved drawing. (Excluding Excavation of PIT) complet...
Distribution Transformer - 3 Phase, 11 KV / 433 V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 . A. Open Bushing Type 250 KVA Aluminium Wdg, Star 2 (5 Star) ---- Work should be carried o...
Erection of Transformer & Structures. Erection of 200 - 250 KVA Transformer. ---- Work should be carried out as per the direction of engineer incharge of work.
Supplying, fixing, wiring, earthelectrode for grounding conduits, I.C. cutout sand other equipments on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit. The pit should b...
Supplying of caution/danger board as per drawing No-ESCOM/GM/CP/40/Dt24-10-2007 ---- Work should be carried out as per the direction of engineer incharge of work.
Fixing of caution/danger board ---- Work should be carried out as per the direction of engineer incharge of work.
Supplying of anti climbing device GI Barbed wire (12mtr/1 kg GI barbed wire) ---- Work should be carried out as per the direction of engineer incharge of work.
Fixing of anti climbing device GI Barbed wire (12mtr/1 kg GI barbed wire ---- Work should be carried out as per the direction of engineer incharge of work.
5 of 81 8.02 Supplying and fixing of Guy wire & GI Wire as per IS-2141, 8 SWG GI wire (4.064 mm Dia), StdWt: 131Kg /KM Rs 75040/MT =Rs 75.04/KG
---- Work should be carried out as per the direction o...
Supplying and fixing of Guy wire & GI Wire as per IS-2141 7/10 SWG Guy wire (7/3.251 mm Dia), StdWt: 680 Kg /KM Rs 77226/ MT=Rs 77.23/KG
---- Work should be carried out as per the direction of engine...
Supplying of lightning arrestors, as per IEC-60099-4 9 KV,5kA polymeric type with GRPUND DISCONNECTOR ---- Work should be carried out as per the direction of engineer incharge of work.
fixing of lightning arrestors, as per IEC-60099-4 9 KV,5kA polymeric type with GROUND DISCONNECTOR ---- Work should be carried out as per the direction of engineer incharge of work.
LT Distribution box as per IS-13947 Part 1 & 2 : LT distribution box for 100/ 250 KVA DTC with MCCB's (SMC) ---- Work should be carried out as per the direction of engineer incharge of work.
1.1 KV Class HR (Heat Registant) PVC insulated & Un sheathed Aluminium Wires Multistrand Single core Lead wires as per IS- 694: 2010: PVC wire - 120 Sq mm Al Wt: 32 Kg. Total Wt: 45.5 Kg / 100 Mtr coi...
Heavy duty Copper Terminal Long Barrel 120 Sqmm Copper terminal, Apprx Wt: 64 Gr. ---- Work should be carried out as per the direction of engineer incharge of work.
PG Clamp Rabbit to Insulated wire 120 Sqmm. ---- Work should be carried out as per the direction of engineer incharge of work.
Line Spacer for TC Wiring (Dwg No. BESCOM.GM/QS&S/38 Dtd. 24-11-2018) ---- Work should be carried out as per the direction of engineer incharge of work.
GI Fish plate ---- Work should be carried out as per the direction of engineer incharge of work.
Guy Clamp - GI ---- Work should be carried out as per the direction of engineer incharge of work.
For Distribution Transformer Centre (DTC) MS Box for Housing the ETV Meter 3 Phase 4 wire 5 Amps , with associated LT CT 0.5 Accuracy Class , ring type, with wiring Clamps, B & N and All other accesso...
Fixing 1 circuit of LT Wiring for 250 / 500 KVA Transformers via metering box. ( Including fixing of necessary supports like 2 Pin cross arms, Spacers etc.,) ---- Work should be carried out as per the...
Measuring Equipment: LT 3 Phase, 4 wire, CT Operated DLMS Complaint ETV Meter- 5A, Class 0.5s Accuracy ( Used for 25 HP/18 KW and above Installations, DTC Metering) ---- Work should be carried out as ...
Supplying of HG fuse Unit as per IS-5350 Part-2, 11KV HG Fuse unit with solid core insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) type (3 nos) ---- Work should be carried out as per the directio...
Fixing DOLO Cutout /Horn Gap Fuse including fixing cross Arm and wiring. ---- Work should be carried out as per the direction of engineer incharge of work.
Supplying and fixing of 11 KV 200 Amps Single break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018 ---- Work should be carried out as per the direction of engineer incharge of work.
Fixing GOS including wiring (11 KV Single break 200 Amps) ---- Work should be carried out as per the direction of engineer incharge of work.
Supplying of H- frame Set for fixing 11 Kv, 200 Amps Single break GOS (For DP Structure for Providing Ne GOS for sectionalisation) MS ---- Work should be carried out as per the direction of engineer i...
Erection of H Frame set ---- Work should be carried out as per the direction of engineer incharge of work.
Digging of Pit 1.80 Mtr Depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC support as per approved Drawing. ( Hard Soil) ---- Work should be carried out as per the direction of engineer incharge o...
Digging pf Pit for Guy set ( Hard Soil ) ---- Work should be carried out as per the direction of engineer incharge of work.
HT & LT Metering Equipment : LT Metering Cubicle at Low Tension for 50 KW to 150 KW having specification. ( Excluding Meter Cost & Modem) & design as per the prototype approval ---- Work should be car...
Erection of LT Metering Cubicle on Platform ---- Work should be carried out as per the direction of engineer incharge of work.
GPRS Modem with accessories. ---- Work should be carried out as per the direction of engineer incharge of work.
LT Feeder pillar box Thermostet Plastic) : 8 Way HRC Fuse Based Thermoset Plastic LT Feeder piller box and 1 No of 630 Amps Load break Switch with copper Bus Bar as Per IS-13947 Part -1&2 (Dwg no BESC...
11 KV, 3 core, XPLE HTUG Cable with pressure extruded inner sheet, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires-2.5 mm dia) ---...
Laying of Cable in Existing Trench / GI Pipe/ Stone ware /RCC Hume pipe using wooden/Aluminium Roolers as directed by the departmental staff. HT Cable 3x95 to 150 Sqmm. ---- Work should be carried out...
Cable Joint and wiring kit for HT UG Heat shrinkable straight Through Joint. 3x95 to 3x150 Sqmm. ---- Work should be carried out as per the direction of engineer incharge of work.
1.1 KV, XLPE or Heat resistant PVC insulated, PVC exutred Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 95 Sqmm, ...
Laying of Cable in Existing Trench / GI Pipe/ Stone ware /RCC Hume pipe using wooden/Aluminium Roolers as directed by the departmental staff. LT Cable 35 to 95 Sqmm. ---- Work should be carried out as...
LTUG Cable Heat shrinkable Through Joint 35 to 95 Sqmm. ---- Work should be carried out as per the direction of engineer incharge of work.
Heat shrinkable Terminations: 35 to 95 Sqmm. ---- Work should be carried out as per the direction of engineer incharge of work.
Soreading and forming with sand alround the cable to a depth of 75 mm and width of 500 mm.(Does not include cost of sand.) ---- Work should be carried out as per the direction of engineer incharge of ...
HDPE/PLB Pipe 50/42 mm with cost and conveyance of all materials, labour, with loading and unloading etc. including unforseen items of work as directed by the Engineer in Charge of work for satisfacto...
Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per dr...
Making and fixing Pot head for HT Cable only, Heat shrinkable type terminations 3x95 to 3x150 Sqmm .
---- Work should be carried out as per the direction of engineer incharge of work.
---- Work should be carried out as per the direction of engineer incharge of work.
Turn Buckle (GI)
---- Work should be carried out as per the direction of engineer incharge of work.
Anchor Rod using 12mm rounds/guy Rod-MS
---- Work should be carried out as per the direction of engineer incharge of work.
Anchor Rod using 12mm rounds/guy Rod-GI
---- Work should be carried out as per the direction of engineer incharge of work.
---- Work should be carried out as per the direction of engineer incharge of work.
Strain Clamp, 3bolt type for 70/90 kn Disc Insulator
---- Work should be carried out as per the direction of engineer incharge of work.
Name of work- Conversion of HT Line to LT Line in the premises of Circuit House at Gadag. Preperation of Test report and submitting to HESCOM and getting approval from compitent authorities. Laying LTUG cables to Executive Engineer PWD Division office, Circuit House, Old circuit houses and other essential buildings in the premises of circuit house at Gadag. Test
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module
---- Work should be carried out as per the...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required.25mm
Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Dong Bell
---- Work should be c...
Supplying and fixing surface / Flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch
---- Work should be carried out as per the direction o...
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket
---- Work should be carried out as per the direction of e...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying of .feet -PVC Batten with integrated LED tube . with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor ...
Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball be...
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, r...
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary ...
Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF ...
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgi...
Supply and fixing of condensing coil for Split Air Conditioners.2 Ton capacity ---- Work should be carried out as per the direction of engineer incharge of work.
Supplying and fixing capacitor's (of approved make) for window /split air conditioners. 25 to 45mfd running capacitor.
---- Work should be carried out as per the direction of engineer incharge of wor...
Supplying and fixing capacitor's (of approved make) for window /split air conditioners.80 to 200mfd starting capacitor. ---- Work should be carried out as per the direction of engineer incharge of wor...
Supplying & fixing relay for over load protection for window and split air conditioners. ---- Work should be carried out as per the direction of engineer incharge of work.
Supplying and fixing the fan motor for blowers and condenser of 1/5 HP, single shaft/double shaft suitable for split / window air conditioners.
---- Work should be carried out as per the direction of...
Supplying & filling refrigerant (F-22/F/12) for air conditioning equipment's. Which includes the labour & Nitrogen gas for pressure and leak testing.
---- Work should be carried out as per the direct...
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .