| .10BOQ (REPAIR/ MAINT / REWIRING OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES IN TECHNICAL AREA AT AF STN SURATGARH) | ||||||
| 1.00 | Attending day to day complaints lodged in complaint register at AF Stn Suratgarh Technical area. The contractor will adhere time schedule for attending complaints as directed by Engr-in-Charge as follows:
(a) Attending complaints for checking the existing electrical items for continuous electric supply including carrying out minor repairs etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repairs such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan (without taking down), shifting/refixing of LED light fittings, switch & socket, MCB etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/ sub mains/ internal circuits of existing electrical system of main building/ block and . required to make the system in order/ functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-In-Charge (this will be included in unit rate).
Notes:- (i) The complaint for "No Light" shall be attended immediately/ On Priority.
(ii) Contractor shall submit the complaint register alongwirth complaint slip verfied from JE E/M or Engr-in -charge.
(iiI) In case daily complaints are not attended,per complaint per day penalty recovery shall be charged Rs. 200/-
(iv) The contractor shall deploy a team of one electrician and one helper to report to JE E/M daily by 0930 hrs to attend complaints and general electrical maintenance as directed by JE E/M or Engr -in-Charge.
(v) Proper attendance register and complaint attended register will be maint by JE E/M.
(vi) The team of complaint attended will be utilised by JE E/M for attending complaints and will not be used by contractor for other maint work which are catered in the subject work.
(vii) All complaints attended and general maint carried out to the satisfaction of Engr-in-Charge for 08 hours per day will be measured as each job. | 240 | Each Job | 1,780 ₹4,27,200 | 1,000 ₹2,40,000 | 200 ₹48,000 Lowest |
| 2.00 | M&L for in replacement of sub-main wiring (concealed) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 150 | RM | 175 ₹26,250 Lowest | 190 ₹28,500 | 300 ₹45,000 |
| 3.00 | M&L for in replacement of sub-main wiring (concealed) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 25 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 200 | RM | 190 ₹38,000 Lowest | 220 ₹44,000 | 380 ₹76,000 |
| 4.00 | M&L for in replacement of sub-main wiring (existing concealed PVC conduit) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through existing PVC/steel conduit including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 350 | RM | 145 ₹50,750 Lowest | 175 ₹61,250 | 270 ₹94,500 |
| 5.00 | M&L for in replacement of sub-main wiring (existing concealed PVC conduit) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through existing PVC/steel conduit including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 350 | RM | 180 ₹63,000 Lowest | 200 ₹70,000 | 350 ₹1,22,500 |
| 6.00 | All as per srl item No 5 here in before but two single core 10 Sqmm | 200 | RM | 220 ₹44,000 Lowest | 250 ₹50,000 | 500 ₹1,00,000 |
| 7.00 | M&L as in replacement of sub-main wiring (Surface) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn on and including 25 mm dia non-metallic PVC conduit fixed on wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 250 | RM | 145 ₹36,250 Lowest | 175 ₹43,750 | 275 ₹68,750 |
| 8.00 | M&L as in replacement of submain wiring with four single core 6 sqmm PVC insulated FRLSH multistranded copper conductor cable drawing into and including stove enameled steel conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 6 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed.
Note- (a) Four runs of single core cable and specified earth continuity conductor and PVC conduit with fitting acessories will be measured as one run.
b) Cost of cutting, chasing and make good to existing surfaces are deemed to be including in the quoted rate by the contractor. | 80 | RM | 195 ₹15,600 Lowest | 250 ₹20,000 | 650 ₹52,000 |
| 9.00 | Taking down carefully aluminum point wiring (light, fans, socket etc) complete including conduit etc and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed. | 2,745 | Per Point | 5 ₹13,725 Lowest | 10 ₹27,450 | 40 ₹1,09,800 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Sept 2026, 6:00 pmClosed
GE AF SURATGARH
SURATGARH
REPAIR AND MAINT AND REWIRING OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES ALONGWITH CONNECTED ITEMS IN TECHNICAL AREA AT AF STN SURATGARH
2026_MES_785693_1
8380/E8
Open Tender
Civil Works
Item Rate
210 days
GE AF SURATGARH
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF SURATGARH
₹90,000
Yes
23 Sept 2026
21 Aug 2026
23 Sept 2026
21 Aug 2026
21 Sept 2026
7 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.1 | BOQ (REPAIR/ MAINT / REWIRING OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES IN TECHNICAL AREA AT AF STN SURATGARH) | - | - | - | - |
| 1 | Attending day to day complaints lodged in complaint register at AF Stn Suratgarh domestic area. The contractor will adhere time schedule for attending complaints as directed by Engr-in-Charge as follows:
(a) Attending complaints for checking the existing electrical items for continuous electric supply including carrying out minor repairs etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repairs such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan (without taking down), shifting/refixing of LED light fittings, switch & socket, MCB etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/ sub mains/ internal circuits of existing electrical system of main building/ block and . required to make the system in order/ functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-In-Charge (this will be included in unit rate).
Notes:- (i) The complaint for "No Light" shall be attended immediately/ On Priority.
(ii) Contractor should be submit the complaint register alongwirth complaint slip verfied from JE E/M or Engr-in -charge.
(iiI) In case daily complaints are not attended,per complaint per day penalty recovery shall be charged Rs. 200/- | 240 | Each Job | 130 | ₹31,200 |
| 2 | M&L for in replacement of sub-main wiring (concealed) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 150 | RM | 131 | ₹19,650 |
| 3 | M&L for in replacement of sub-main wiring (concealed) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 25 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 200 | RM | 132 | ₹26,400 |
| 4 | M&L for in replacement of sub-main wiring (existing concealed PVC conduit) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through existing PVC/steel conduit including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 350 | RM | 133 | ₹46,550 |
| 5 | M&L for in replacement of sub-main wiring (existing concealed PVC conduit) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through existing PVC/steel conduit including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 350 | RM | 134 | ₹46,900 |
| 6 | All as per srl item No 5 here in before but two single core 10 Sqmm | 200 | RM | 135 | ₹27,000 |
| 7 | M&L as in replacement of sub-main wiring (Surface) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn on and including 25 mm dia non-metallic PVC conduit fixed on wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. | 250 | RM | 135 | ₹33,750 |
| 8 | M&L as in replacement of submain wiring with four single core 6 sqmm PVC insulated FRLSH multistranded copper conductor cable drawing into and including stove enameled steel conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 6 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed.
Note- (a) Four runs of single core cable and specified earth continuity conductor and PVC conduit with fitting acessories will be measured as one run.
b) Cost of cutting, chasing and make good to existing surfaces are deemed to be including in the quoted rate by the contractor. | 80 | RM | 135 | ₹10,800 |
| 9 | Taking down carefully aluminum point wiring (light, fans, socket etc) complete including conduit etc and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed. | 2,745 | Per Point | 136 | ₹3,73,320 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.96 MB
Tenderdocuments8380.pdf
Tender Documents • 0.93 MB
BOQ_880434.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .