Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59,205Accepted-AOC | L1 | Accepted-AOC ACCEPTED. | |
| 2 | L1₹59,220Accepted-AOC S S HOGG MARKET 2ND FLOOR SHOP NO W2 B3 KOLKATA 700087 | KOLKATA | WEST BENGAL | 700087 | L1 | Accepted-AOC ACCEPTED. | |
| 3 | L1₹2.2 LAccepted-AOC 56 LENIN SARANI P O DHARAMTOLLA P S TALTALA KOLKATA 700013 | KOLKATA | WEST BENGAL | 700013 | L1 | Accepted-AOC ACCEPTED. | |
| 4 | L1₹6.4 LAccepted-AOC 4 BIDHAN ROAD BASANT NIKETAN 1ST FLOOR BIDHAN ROAD SILIGURI DARJEELING WEST BENGAL 734001 | JALPAIGURI | WEST BENGAL | 734001 | L1 | Accepted-AOC ACCEPTED. |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
2 Sept 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Principal, NBDCH
Sushrutanagar, Dist- Darjeeling, Pin- 734012
Supplying and installation of Dental Equipment. (2nd Call)
2022_HFW_395427_1
401/NBDCH Date. 16.08.2022
Open Tender
Equipments
Item Wise
30 days
Siliguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹24,000
Yes
Office of the Principal, NBDCH
12 Nov 2022
16 Aug 2022
5 Sept 2022
16 Aug 2022
2 Sept 2022
18 Aug 2022
18 Aug 2022
Dental Equipments
Automatic panoramic with Cephalometric X-Ray Developer (Compatible for GENORAY PAPAYA PLUS OPG Machine)
Lead Screen
Ultrasonic cleaner (minimum 6 ltr capacity with mesh bucket)
Ultrasonic cleaner (minimum 13 ltr capacity with mesh bucket)
Wards periosteal Elevator
Coupland's Elevator
Cryer's Elevator
Warwick James Elevator (St)
Warwick James Elevator (Curved)
Lower molar forceps
Upper molar forceps
Upper premolar forceps
Root forceps
B P handle (No.3)
Metal suction tip
Lawson tait forceps
Austin flap retractor
Toothed tissue forceps
Needle holder (with catch)
Sinus forceps
Mosquito haemostat (Curved)
Artery haemostat (Curved)
Suction machine
Bone AWL (Curved)
Air polishers attached with dental chairs. (Prophy Jet)
Gracey curette set of 6 instruments
Universal curettes
Orban knife
Scissors goldman-fox
Glickman periosteal elevator#24G
Schluger#9-10 surgical file
Blakes gingivectomy handle
Crane Kaplan pocket marker set of two
Laser tips
Ultrasonic Scaler Machine with corresponding tips (Manufacturer model UDS-P:-Woodpecker)
SATELEC SCALER: SATELEC Suprasson® P5 Booster Technical specifications Supply voltage: . . . . . . . . . . . . . . . . 110 V~ or 220/230 V~ 50/60 Hz Equipment classification: . . . . . . . . . Class II - BF type Operating conditions: . . . . . . . . . . . Intermittent duty 5min / 10min Max. power consumption: . . . . . . . . . 40 VA Vibration frequency: . . . . . . . . . . . . 27 to 32 kHz Water pressure: . . . . . . . . . . . . . . . 1 to 5 bar (15 to 73 psi) Overall dimensions: . . . . . . . . . . . . . Height 60 mm . . . . . . . . . . . . . . . . . . . . . . . . . . Width 155 mm . . . . . . . . . . . . . . . . . . . . . . . . . . Depth 150 mm Weight: . . . . . . . . . . . . . . . . . . . . . 1.2 kg
RESTORATIVE INSTRUMENTS KIT CONTAINING 1 x Explorer # Double Ended # 1 (EXD5) 1 x Spoon Excavator # 1 1 x Ball Burnisher # 1 1 x PLUGGER serrated #1 Conservative instruments S/19 in pouch (EXD5) 1 x Hatchet # 1 (CP53/54) 1 x Plastic filling instrument # 1 (PF2) 1 x Margin trimmer premium # 1 (MT28H) 1 x Margin trimmer premium # 1 (MT29H) 1 x Hollenback carver # 1 (CVHL3S) 1 x Ward carver # 1 (CVWR1S) 1 x Diamond shape # 1 # small (CVFR2/3H) 1 x Plastic filling instrument # 1 (PLGH3) 1 x London College (DPU17) 1 x Single end probe # 1 (EXS6XL) 1 x Thin willan # 1 (POW6) 1 x Cement spatula # 1 (CS3) 1 x Chisel # 1 (CP7) 1 x Hoe # 1 (CP24) 1 x Mirror handle # MH3 # 3(MH3) 1 x Mouth mirror top plain no. 5
Rubber dam kit (Pedo) -(Item Code Ddkp)Manufacturer: GDC
Rubber dam kit (adult)(Item Code DDK) Manafacturer -GDC Rubber dam forcep RDF4E Rubber dam punch RDPA Rubber dam sheet RDLA Rubber dam clamp set RDCOB11 Rubber dam template RDT Rubber dam frame RDAF6P
THERMOPLASTICISED GUTTA PERCHA GUN AND PEN SYSTEM Obturation Pen System 1 x Main unit 1 x Charging stand 1 x Power adapter 1 x WP4004 tip (Taper 4%) 1 x WP4504 tip (Taper 4%) 1 x WP5506 tip (Taper 6%) 1 x WP5508 tip (Taper 8%) 4 x Heat insulation sleeve of tips 1 x Instruction manual Obturation Gun 1 x Obturation gun 1 x Power adapter with cable 1 x Gutta percha injection needle 23G # 24mm 1 x Gutta percha injection needle 23G # 28mm 2 x Gutta percha injection needle 25G # 24mm 2 x Heat insulation hood 1 x Heat insulation sleeve for injection needle 2 x Cleaning brush 1 x Pushing ram 1 x Wrench
Dental amalgamator with side-to-side movement with digital timer
ELECTRIC PULP TESTER (DIGITAL) 1 x Pulp vitality tester 1 x High output alkaline battery (9-volt) 2 x Autoclavable stainless steel standard size tooth probes (anterior and posterior) 2 x Autoclavable stainless steel precision size tooth probes, for testing small or difficult to access labial or lingual surfaces or accessible crown margins 1 x Autoclavable lip clip with wire assembly 1 x Durable plastic storage case
NEEDLE BURNER WITH SYRINGE CUTTER
Class B fully automatic Autoclave (front loading having wet and dry cycle minimum capacity 22 liters)
Restorative Instruments set(pedo)
Extraction forcep pedo set
DC X-RAY MACHINE TECHNICAL DATA Generator- High frequency, Microprocessor controlled, Constant potential (DC). Control of high voltage-Closed loop. X-ray Generator type-560 Watts (max) at 70 Kv, 7 mA. High Voltage Range- 50 kV to 70 kV ( in steps of 1 kV). Tube head current range- 4 mA-8 mA ( in steps of 1 mA). Control of tube current- Closed loop. Time to perform test- 40 msec to 4 sec (in steps of 10 msec). Exposure timer accuracy-<± 5%. Focal spot sizes, minimum values-0.4, 0.5 and 0.8 mm IEC . Duty Cycle-1.15 Adaptive & auto limit based on temperature. PHYSICAL RQUIREMENTS Weight of tube head-5 kg (approx.) Support tube material -Aluminum. Mounting type-Base unit adaptors for wall mounted or floor mounted. Height no unit with arms folded-49” ± 0.5 (1245 mm) – wall mount. 77” ± 0.5 (1956 mm) – floor mount. Arm length options-1465 mm, 1695 mm & 1915 mm.
Wet model trimmer with 10/12 inches carborundum stone disc
Crown remover (Pneumatic)-micro stroke frequency -20 moments per second , weight -250gms , steel grade-302
LED Light cure machine (Woodpecker)
Light body dispensing gun-Completely operated by hand, cartridge -two component,easy auto-mixing-1:1, made up of high quality plastic( reinforced nylon frame, durable plastic rod)
Electric inlay wax carver- Single Electric carving pen, Max temperature 230'C, 4 extra stainless steel tips.
Base former
SET OF PILERS CONTAINING 139 piler (Tc insert) with 1 sqmm tip (CAT) Adams pilers with Tc Insert (JAYPEE) Band cutting scissor (CAT) Band pusher Band seater Band contouring pliers Band removing pliers Pin and ligature cutter with Tc coated (CAT) Distal end cutter with Tc coated (CAT) Weingart pliers with Tc coated (CAT) Artery forceps straight and curved Mathews pliers Howe's pliers straight and curved Bracket holding forceps Measuring gauge / bracket measuring gauge (murli) 444 ribbon arch pliers Debonding pliers straight and curved Loop forming lpiers Half round pliers Heavy duty wire cutter Wire tugger Crimping pliers 3 prong pliers Turret without torque
X-ray viewers
Spot welder with soldering attachments
Typodent articulator with metal teeth
Typodont models for different malocclusion
Shaef Trading Systems
RSM INTERNATIONAL
QUALITY TECHNOLOGY
RSM INTERNATIONAL
QUALITY TECHNOLOGY
CHOWDHURY BROTHERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .