| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.0 L+₹2.8 L (18.7%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹19.4 L+₹4.3 L (28.2%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
12 Sept 2024, 6:00 pmClosed
HQ CWE PATIALA
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact 01752200082
CERTAIN REPAIR AND MAINTENANCE/ IMPROVEMENT TO WATER COOLED AC PLANTS CHILLAR, CONDENSER PUMP MOTOR AND AHU ALONGWITH CONNECTED ITEMS IN TECH AREA AT MIL STN DAPPAR
2024_MES_665607_1
CWE/PAT/T-19/2024-25
Open Tender
Electrical and Maintenance Works
Works
180 days
DAPPAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) DAPPAR
₹40,000
26 Oct 2024
12 Jul 2024
14 Sept 2024
12 Jul 2024
12 Sept 2024
29 Jul 2024
12 Jul 2024 - 27 Jul 2024
Amount
Removing old unserviceable thermal insulation and supply and insulation of thermal insulation thickness 40mm on ducts / chiller pipe line exposed to sun light using closed cell O nitrite rubber elastometric insulation of density 40-55 kg/m3 thermal conductivity of 0.037 W/mk at 20 degree celcius mean temp and MZ 7000 (without any additional vapour barrier) and with chemical treated factory laminated Woven fibre glass cloth with 200+/- 20 gsm to be applied on ducts manufactureds recommended rubber based adhesive in a blend of solvents complete all as specified and as directed.
Materia & Labour for descaling of complete condenser units for central/ package type AC plants of capacity Condenser unit of AC plant up to 60 TR by means of adding descaling chemical solution (HCL) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and re fixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. all as specified and directed
Cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of PVC finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by Engineer in Charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable PVC guard, water distibutor, PVC pipe, cooling tower motor etc of up to 100 TR capacity of the AC plants at different locations complete all as specified and as directed.
Servicing of cooling coils and air filters of AHUs intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for capacity upto 14000 CFM.
Removing old unserviceable port Y strainer and material and labour for Y strainer 100mm size of both end flanged including supply and welding flange of size 100 mm two nos complete all as specified and as directed.
Supply and fix in repairs Gun Metal gate valve with Iron wheel head screwed both ends for GI steel tubing 25 mm dia including taking down unserviceable valves complete all as specified and directed
Supply and fix in repairs Gun Metal gate valve with Iron wheel head screwed both ends for GI steel tubing 32 mm dia including taking down unserviceable valves complete all as specified and directed
Dismaltling and Material & Labour Angle iron 50x50x5 mm for post & struts for support to cold water and hot water pipe line of AC Plant including cutting tops to shape as directed, drilling holes, nothich for wire etc including all necessary drilling, bolting or riveting, etc conforming to FE 410W Gde E-250 complete all as specified and directed
Supply , installation and testing in replacement of temperature on / off controller, 8 Amps relay for compressor (Exsiting Model No SZ-7510T at site) with sensor connected in MAGs (No and Nc) complete as specified and as directed.
Supply and fixing in replacement of super GEC 1.5 Sqmm 2 core copper white twin flate double layer insulation appliances wire , 23/52 complete as specified and as directed. Loc :- For connection to sensor , AC plant panel to AC 1 MAG and AC 2 MAG
Taking down old unserviceable butter fly valve and material and labour for butter fly valve of size 100 mm with rubber packing complete all as specified and as directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 40 mm complete all as specified and as directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve of size 20mm with rubber packing complete all as specified and as directed.
Supply, fixing, testing and commissioning in replacement of 100 mm size non-return valve with dual plate of CI body SS plates vulcanized NBR seal flanged end and PN 1.6 pressure rating for chilled / hot water circulation including insulation complete all as specified and as directed.
Taking down old unserviceable water flow switch of any size, supply and fixing testing of water flow switch ( Flow rate 150 psi) as per existing make and model / suitable size including suitable wiring with control panel complete all as specified and as directed.
Supply, installation and testing in replacement of 3 Way valve with actuator as per suitable site condition all as specified and directed .
Taking down unserviceable liquid line filter drier and material and labour for liquid line filter drier suitable for 13 TR /20 TR water cooled scroll unit of makeBlue Star including removing of refrigerent empty cylinder R-22 flushing the system with nitrogen gas pressure testing and leak repairing vaccumising the system 700 micron charging the refrigerent of R-407 / R22, complete all as specified and as directed.
Supply, fixing and testing in replacement Microprocessor Scroll Controller for compressor of 39 TR Capacity of central type AC Plant ( existing Make Blue Star) having start / stop functions, settings option to change the setting along with all suitable connection / wiring as per requirment completed all as specified and directed.
Taking down old unserviceable expansion valve up to 20 TR compressor suitable for using 39 TR Water Cooled centralised AC plant complete all as specified and as directed.
Taking down old unserviceable Air vent valve 15 / 20 mm and supply and fixing testing of air vent valve 15 mm complete all as specified and as directed.
Supply and fix in replacement of MCB TPN 40-100 Amp 415 volt , 10ka complete all as specified and as directed.
Supply and fix in replacement of MCCB 160 Amp, 4P, 415 volt , 36KA complete all as specified and as directed.
Supply and fix in replacement of MCCB 200Amp, 4P, 415 volt , 36KA complete all as specified and as directed.
Supply and fix in replacement of MCCB 400 Amp, 4P, 415 volt , 36KA complete all as specified and as directed.
Supply and fixing in replacement of MCB SP 6 To 32 amp rating 240V, 10KA 'C' curve complete all as specified and directed.
Supply and fixing in replacement of MCB SPN 32 AMP rating 240V, 10KA 'C' curve complete all as specified and directed.
Supply and fixing in replacement of MCB SPN 40 to 63 AMP rating 240V, 10KA 'C' curve complete all as specified and directed.
Providing and fixing in replacement of measurement range 0 - 150 psi, 0-10 kg/sqcm Glycerin filled botton connecteion round type pressure gauge complete all as specified and as directed.
Supply and fix in replacement of Chilled water sensor as per existing make and type complete all as specified and as directed.
Supply and fix in replacement over load relay 9 to 15 amp complete all as specified and as directed.
Supply and fix in replacement over load relay 6 to 10 amp complete all as specified and as directed.
Supply and fixing in replacement of high pressure switch (HP switch) upto 260 PSI NO and 190 PSI NC including removing of refrigerent empty cylinder and checking of pressure testing leak testing vaccume the system of 700 micron charging the refrigerent in the system complete all as specified and as directed.
Supply and fixing in replacement of low pressure switch (LP switch) upto 25 PSI NO and 45 PSI NC including removing of refrigerent empty cylinder and checking of pressure testing leak testing vaccume the system of 700 micron charging the refrigerent in the system complete all as specified and as directed.
Disconnecting, dismantling the defective three phase induction motor 415 volts 50 Hz of any RPM for motor of Capacity 15 HP and rewinding with super enamelled copper wire of best quality of existing size / gauge and weight including replacement of insulation material, varnish bearing connection plate and all other petty items required to make the motor in functional and reassembling the motor including installation commissioning and testing on full load all as specified and as directed. NOTE :- (i) Disconnecting and removing the electric motor from installed position and loading unloading, transporting to authorised/approved work shop (ii) Dismantling existing burnt winding from the motor and rewinding complete with super enamelled copper winding wire of existing guage including all material such as insulated paper sleeves tape varnish etc complete for class F insulation and including shaft metalising, bearing cover slieving , necessary replacement of cooling fan, nut-bolt etc (iii) Loading, unloading and transporting motor & reinstalling in position and in alignment including electric conection commissioning and testing in actual working condition for 8 hours continuosly to check the performance on full load and designed RPM to the complete satisfaction of Engr-in-Charge all as specified and directed
All as per Sr Item No 34 here-in- before but for Induction Motor of Capacity 7.5 / 10 HP
Disconnecting, dismantling of centrifugal monoblock pump set 10 / 7.5 Hp Capacity of any RPM and dismantling and replacement of defective parts such as impeller nut, glant, impeller key, gland packing water deflector bush bearings sleeve, gasket, volute stud and nuts suction and delivery flange and stud and nuts and all other petty items required to make the pumpset in functional and reassembling the pumpset including installation commissioning and testing all as specified and as directed.
Material and labour in replacement of for replacement of terminal connecting plate suitable for 7.5 HP/5 HP/3HP/2HP of monoblock pumpset complete all as specified and as directed.
Material and labour in replacement of fanbelt any size of suitable model for using of AHU motor, complete all as specified and as directed.
Supply and charging of Refrigerent R-22 in sealed container of 45 Kg complete all as specified and as directed.
Preparation of old painted surface of MS / CI pipes inlet / out let and applying a coast of synthetic enamel paint as per colour code given by the deptt complete all as specified and as directed.
Supply, laying and testing in replacement of MS pipes (ERW steel) including cutting bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 100mm as per IS 3589 (1981) thickness 6.0 mm fixed in replacement of existing unserviceable, by cutting road and footpath and making surface good as previous complete all as specified and as directed.
Supply, laying and testing in replacement of MS pipes (ERW steel) including cutting bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 32 mm as per IS 3589 (1981) thickness 6.0 mm fixed in replacement of existing unserviceable, by cutting road and footpath and making surface good as previous complete all as specified and as directed.
Supply, laying and testing in replacement of MS pipes (ERW steel) including cutting bending and welding as per site requirement and specials with flanged and drilled ends, jointing materials like nuts, bolts and gasket etc of nominal dia 25 mm as per IS 3589 (1981) thickness 6.0 mm fixed in replacement of existing unserviceable, by cutting road and footpath and making surface good as previous complete all as specified and as directed.
Providing and fixing in replacement of in position the mercury-in-glass industrial type thermpmeters range 20 to 55 degree cencius & 0 to 120 degree fahrenheit complete all as specified and as directed.
Servicing / Cleaning and testing of HWG capacity 55 KW / 63 KW capacity safely, Materia & Labour for checking and replacement of burnt out / not working of thermostate / suitable elements as per site conditions , all internal control wiring alongwith all necessary connections check and repair complete all as specified and directed
Supply , installation and testing in replacement of Digital step contoller of Hot Water Generator 55 KW / 63 KW capacity along with Voltmeter and apm meter with all necessary wiring / connection complete as specified and as directed.
Supply and fix in replacement of DOL starter for 7.5 HP / 5.5 KW motor complete all as specified and as directed.
Material and labour for taking out all old unserviceable PVC fills from cooling tower of capacity upto 100 TR and supply anf fixing of fills of size 300mm x 200mm x 150mm (Approx fils qty 80 -100 Nos)all required at site or existing size of fills at site conditions completeed all as specified and directed.
Supply and fixing in replacement of air intake mesh suitable / as per existing size for covering of cooling tower alongwith all necessary items all as specified and as directed.
Taking up condenser / evaporator from AC plant and transporting to condenser manufacture workshop and removing old unserviceable copper tube from condenser and supply, fixing testing and commissioning copper tube cell for existing size and capacity and nos of copper cell for condenser suitable for 39 TR water cooled scroll unit complete all as specified and as directed. Note : Warranty of condenser defect liability period is minimum one year after completion of contract.
Supply, installation, testing and commissioning in replacement of suitable size of electric rod heater for hot water generator complete all as specified and as directed.
Material and labour for replacement of sprinkler of 90/100 TR cooling tower including all necessary connections all as specified and as directed.
Supply and fix in replacement of preforated cable tray hot dip galvanised of size3mm mm thick, 200mm width and 40mm height made out of GI sheet and all as specified and directed.
Taking down existing any size of cable, Supply,laying,jointing,testing LT cable, XLPE insulated,PVC insulated armoured, with aluminium conductor ,1100V grade complete all as specified and directed for 4 core 16 sq mm. Location :- AC Plant panel to AHU 1 & AHU 2
Taking down existing unsv any size of cable, Supply,laying,jointing,testing LT cable, XLPE insulated,PVC insulated armoured, with aluminium conductor ,1100V grade complete all as specified and directed for 3.5 core 300 sq mm. Location :- For connection of Stebilizer
Taking down UNSV Filters and Supply , fixing and testing of AHU Pre Filter overall size as per site 595 x 290 x 50mm , Box type or existing suitable size complete all as specified and as directed.
Taking down UNSV Filters and Supply , fixing and testing of AHU Pre Filter overall size as per site 595 x 596 x 50mm , Box type or existing suitable size provide complete all as specified and as directed.
Supply and fixing in replacement of push Button / Auto manual switch / Micro Switch / potentiometer / Limit switch / Lever switch for 200 KVA Servo stabilizer as specified and as directed.
Supply and fixing in replacement of indicator light / DPDT/SPDT/SPST for 200 KVA Servo stabilizer as specified and as directed.
Supply and fixing in replacement of carbon brush for 200 KVA Servo stabilizer as specified and as directed.
Supply and fixing in replacement of Dimmer 200 Amps capacity for200 KVA Servo stabilizer as specified and as directed.
Supply and fixing in replacement of transformers for 200 KVA Servo stabilizer as specified and as directed.
Taking down old unservicable heating strips and supply and fixing of heating strip suitable to 13/20 TR compresser with all necessary connections complete all as specified and directed
Taking out unserviceable servo auto manual voltage stabiliser and transporting at work shop, opening of Voltage stabiliser of capacity 200/250KVA and repair / replacement of unserviceable spare parts such as PCB/servo card, voltmeter 500v : 96mm-02Nos, 300V:72mm-03Nos, Three phase control panel - 01 No, Carbon bruses - 12 Nos, Variac coil 200 Amps, control transformer (CT) - 02 Nos, reinstalling at its original position after repair, servicing and testing complete all as specified and as directed.
Materia & Labour for dehydration/filtration of 200 KVA /250 KVA Stebilizer oil with mobile transformer filtration plant at site with all required accessories connected to transformer and carrying out filtration of old transformer oil for the desired dielectric strength of 60 KV at 2.5mm gap all as specified and directed.
Material only transformer oil for topping up low viscosity EHV grade having 60 KV di-electric strength conforming to IS-335 in original company sealed drum for replacement or topping up to oil level mark at the conservator all as specified and directed
Disconnecting HT/LT and earth termination connections from stebilizer 200/250 KVA Capacity , taking down the stebilizer from plinth/platform and loading into the vehicle; transporting the same to workshop for carrying out necessary repairs and back reconnecting HT/LT connections at site and charging the on load, commissioning and testing including meggar test at site all as directed
Supply, instalation and testing in replacement of LED Solar Lifgt fitting 20 Watt including lithium ion battery, solar panel, charge controler with dusk soen sensor complete fixed at height of 8 mtr height of pole of 100mm dia medium grade GI with aluminium paint of 100mm dia midium grade GI with aluminium paint. ( Including all excavation and PCC Work).
Supply and fixing in replacement of Manual 4 Pole 400A , 415V change over in sheet steel enclosure with extended handle switch confirming IS /IEC 60947-3 complete all as specified and directed
Supply, assembly and erection in repair of GI sheet with C & SS rectangular/square duct made out of L shapped hollow profile, duly factory boxed, incl all accessories such as corner, cleat, carraige bolt, gasket and appropriate sealant on longitudinal joint etc complete of size 24 gauge complete all as specified and directed .
Material & Labour in repair for duct insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 50 mm all as specified and including the following :- (a) Material & Labour for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of milllscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Materia & Labour for applying rubber based adhesive CPRX compound. (c) Materia & Labour for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) Materia & Labour for securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 50 mm at maximum intervals of 1.2 mtr.
Taking down unserviceable /burnt scroll compressor of capacity 13 TR and M & L for scroll compressor of capacity 13 TR suitable for 39 TR air cooled plant of make Voltas including removing of refrigerent R-407 in an empty cylinder, flushing the system, carrying out nitrogen gas pressure testing and accordingly leak reparing(if any), vaccumising the system, charging the refrigerent - R-407C complete all as specified and directed Make :Danfoss Model No.SY300A4PBE complete all as specified and directed Note:-Initial charge of refrigerent will be paid separately
Excavation in trenches in soft/loose soil n exc 1.5m wide andn. Exc1.5m deep and getting out includingforming bottom surfaces to required level or slope for taking out embeded cables,brick/pcc protective tiles and relaying new/old cable complete all specified and all as directed
Materia & Labour for sand cushioningng (drysand) to under ground cable for cable protection provided with layers 8cm deep before laying and 15 cm after laying the cable complete all as specified and directed. Note :- Punned thickness will be measured only.
Supply and laying in replacement of factory un reinforced precast concrete cable cover class LV, type-1, flat, size 250 x 150 x 40mm with ISI mark factory made complete all as specified & directed.
Removal of surplus excavated soil to a distance exc 50 m but not exc in 100 m and deposited where directed at a level n'exc 50 m above the starting point complete all as specified and directed.
Returning filling in soft/ loose soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer complete all as specified and as specified.
M/s Kataria Construction Company (BID ID -3093668)
HARISH SALES CORPORATION (BID ID -3083990)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .