Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹124.2 CrAccepted-AOC LANE 5 NEAR SARDAR PATEL STATUTE 10 MAHADEVNAGAR SOCIETY STADIUM ROAD AHMEDABAD | AHMEDABAD | AHMEDABAD | GUJARAT | 1st | Accepted-AOC First lowest | |
| 2 | 2nd₹130.4 Cr+₹6.2 Cr (4.98%)Rejected-Finance RG METRO ARCADE SECTOR 11 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | 2nd | Rejected-Finance second lowest | |
| 3 | 3rd₹131.5 Cr+₹7.3 Cr (5.91%)Rejected-Finance | 3rd | Rejected-Finance third lowest | |
| 4 | 4th₹133.7 Cr+₹9.5 Cr (7.65%)Rejected-Finance C 88 RDC RAJ NAGAR GHAZIABAD 201002 U P | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201002 | 4th | Rejected-Finance fourth lowest | |
| 5 | 5th₹137.5 Cr+₹13.3 Cr (10.7%)Rejected-Finance WARD NO 19 BRAHMNAGAR GAFI NO 2 ROBERTSGANJ DIST SONBHADRA | ROBERTSGANJ | SONBHADRA | UTTAR PRADESH | 5th | Rejected-Finance fifth lowest |
Tender Value
₹161.5 Cr
EMD Value
₹1.6 Cr
Closing Date
14 Feb 2022, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
OFFICE OF THE SUPERINTENDING ENGINEER, 17TH CIRCLE UPJN (U) CHARUCHANDRA PURI COLONY INFRONT OF DIG BUNGLOW, GORAKHPUR
Gorakhpur sewerage scheme zone c2 part 1 under AMRUT SCHEME
2022_UPJNM_673065_1
10/v-15/10 dt 06.01.2022
Open Tender
Civil Works - Water Works
Percentage
730 days
GORAKHPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹23,600
PROJECT MANAGER, CONSTRUCTION UNIT, UP JAL NIGAM
₹1.6 Cr
OFFICE OF THE SE, UPJN, GORAKHPUR
29 Mar 2022
7 Jan 2022
14 Feb 2022
7 Jan 2022
14 Feb 2022
7 Jan 2022
18 Jan 2022
120 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Work | |||||
| 1.01 | EARTH FILLING IN S.T.P. CAMPUS
Supplying and Earth filling of earth in plingth in layers not exceeding 20 cm in depth including , breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing etc. including all labour material T&P etc complete in all respect upto satisfaction of engineer in charge. | 9,690 | cum | 282.21 | ₹27,34,614.9 |
| 1.02 | S.T.P.
Total station survey of the project area, construction of level pillars at all important locations, soil investigation, designing (As per relevant seismic zone), supplying all materials, constructing STP of 10 MLD on SBR technology on module basis such as on given site area of about 4 acres, the proposed 10 MLD STP is to be extended (in near future) upto 40 MLD capacity, with desired effluent parameters as BOD<10 mg/l, COD<50 mg/l, T.S.S.<10 mg/l, Total Nitrogen <10mg/l, TP (as P)<1mg/l, Fecal coliform (MPN/100ml)<100, pH= 6.5 to 8.5, with trussed fibre shed over walkway of STP, Laboratory & its equipments, glassware, chemicals etc 1 no Type 'C' Residence having an area of 62.70 m2 each, Godown having an area of 50.0 m2 internal approach road, Landscaping, Tubewell boring upto min 2nd strata for water supply in the campus alongwith its submersible pumps, piping, valves, over head storage in min 2000 litres, power connection, wiring etc complete, campus Toilet effluent to be connected in the M.P.S. with all other appurtenant works, supplying of 1400 mm dia (I.D.) D.I. K-7 Pipe, excavation, laying from treated effluent pipe to open channel including its trenchless crossing of existing flood protection earthen bund also including its bye pass by 1400 mm dia (I.D.) D.I. K-7 pipe upto TEPS), fixing / jointing with all specials including two nos sluice valve / knife gate true to gradient for diverting the effluent flow during Monsson and dry period with all material, labor, T&P etc, complete in all respect including 3 months Trial & run after successful testing and commissioning for Gorakhpur Sewerage Scheme, Sub Zone C2 part 1. | 1 | job | 14,71,79,123.9 | ₹14,71,79,123.9 |
| 1.03 | M.P.S. (CIVIL WORKS)
Civil work of MPS of 40 MLD capacity (indicative dia. is 12.0 m I.D. and depth is 19.0 m B.G.L.) with well sinking (including its well plugging etc all) interconnection of 900 mm dia (I.D.) rising main of DI K-9 in MPS at proper level and alignment including hydraulic testing, Metering room, H.T. panel room, Transformer and D.G. platform, screen channel, Gate valve chamber, Sluice valve chamber, Air valve chamber, common header chamber etc complete for completion of work in all respect. | 1 | Job | 8,80,98,162.03 | ₹8,80,98,162.03 |
| 1.04 | E&M WORKS
E&M works will be for 10 MLD capacity with peak factor of 2.25, including manual and mechanical screens (screens should be designed and installed for complete Zone C discharge i.e. 40 M.L.D. average discharge), gate, pumps (2 No sewage submersible pumps peak discharge 22.5 MLD Capacity (1W+1S)), D.G. set, sub station, power connection all other E&M and instrumentation components with 3 months trial & run. Complete in all respect for proper completion of work. The discharge arrangement from M.P.S. should be such as during proper functioning of S.T.P. etc it goes to S.T.P. and during Major maintenance etc it can be diverted to join the TEPS disposal pipe.
Indicative quantity is attached . | 1 | job | 3,32,10,340.83 | ₹3,32,10,340.83 |
| 1.05 | (Treated Effluent Pumping Station) T.E.P.S.
Civil work of TEPS of 40 MLD capacity (indicative dia. is 12.0 m I.D. and depth is 11.0 m B.G.L.) with well sinking (including its well plugging etc all), interconnection of 900 mm dia (I.D.) rising main of DI K-9 in TEPS at proper level and alignment, including hydraulic testing, Metering room, H.T. panel room, Transformer and D.G. platform, Gate valve chamber, Sluice valve chamber, Air valve chamber, common header chamber etc complete for completion of work in all respect. | 1 | job | 4,34,55,563.84 | ₹4,34,55,563.84 |
| 1.06 | (Treated Effluent Pumping Station) T.E.P.S.
E&M works will be for 10 MLD capacity with peak factor of 2.25, including gate, pumps (2 No TEPS pumps to handle discharge of 10 MLD Capacity (1W+1S)), D.G. set, sub station, power connection all other E&M and instrumentation components with 3 months trial & run. Complete iin all respect for proper completion of work.
As per attached Indicative quantity. | 1 | job | 1,44,46,389.23 | ₹1,44,46,389.23 |
| 1.07 | RISING MAIN
Soil investigation, designing (hydraulic & structural design as per Manual on sewerage and sewage treatment, G.O.I.), supply of 900 mm dia. D.I. K-9 pipe conforming to latest I.S. 8329 / 2000 or its latest amendments including D.I. S/S or flanged specials, C.I. double flanged sluice valves as per I.S. 780 / 1960 or its latest amendments complete in all respect F.O.R. destination including insurance, excavation of trench in all types of soil, carting of pipes, specials & S.V., lowering them into trenches over proper bedding (including supply of all material, carting, laying in layers), laying R.M. pipe true to alignment and gradient, jointing, fixing in position including nut & bolts, rubber insertion, white lead etc including cutting of pipes etc for making of lengths, filling back the trench with excavated earth, compacting and inluding supply of all material for construction of R.C.C. thrust blocks as per requirement etc. testing & commissioning complete in all respect upto the satisfaction of Engineer-In-Charge. | 240 | RM | 23,452.45 | ₹56,28,588 |
| 1.08 | RISING MAIN
Soil investigation, designing (hydraulic & structural design as per Manual on sewerage and sewage treatment, G.O.I.), supply of 450 mm dia. D.I. K-9 pipe conforming to latest I.S. 8329 / 2000 or its latest amendments including D.I. S/S or flanged specials, C.I. double flanged sluice valves as per I.S. 780 / 1960 or its latest amendments complete in all respect F.O.R. destination including insurance, excavation of trench in all types of soil, carting of pipes, specials & S.V., lowering them into trenches over proper bedding (including supply of all material, carting, laying in layers), laying R.M. pipe true to alignment and gradient, jointing, fixing in position including nut & bolts, rubber insertion, white lead etc including cutting of pipes etc for making of lengths, filling back the trench with excavated earth, compacting and inluding supply of all material for construction of R.C.C. thrust blocks as per requirement etc. testing & commissioning complete in all respect upto the satisfaction of Engineer-In-Charge. | 16.45 | RM | 14,257.75 | ₹2,34,540.02 |
| 1.09 | OPEN CHANNEL DRAIN (for channalising the treated effluent discharge from flood frotection bund towards Rohini river
Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.(0-1.5M) | 61.5 | Cum | 205.9 | ₹12,662.85 |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_1072931.xls
BOQ Document • 0.43 MB
90477495.pdf
Tender Document • 3.74 MB
tenderdoc.pdf
Tender Document • 10.12 MB
90477497.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .