Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹445.51+₹43.52 (10.8%)Rejected-Finance CHHINDWARA | CHHINDWARA | CHHINDWARA | MADHYA PRADESH | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹591.18+₹189.19 (47.1%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical All required Document Not Submit | |
| 5 | Rejected-Technical NAHAR COLONY KOLUA ROAD BUS STAND KE PASS ASHOKNAGAR | ASHOKNAGAR | ASHOKNAGAR | MADHYA PRADESH | - | Rejected-Technical All required Document Not Submit |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
26 Jun 2023, 4:00 pmClosed
DIVISIONAL MANAGER
Division manager chhindwara project division khajri road chhindwara 480001
TENDER REGARDING ITEM SUPPLY FOR CHAIN LINK FENCING AND RCC POLE
2023_MPVVN_279890_1
918/2023_24
Open Tender
Miscellaneous Goods
Item Rate
30 days
Division manager chhindwara project division
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹30,000
18 Jul 2023
29 May 2023
27 Jun 2023
29 May 2023
26 Jun 2023
29 May 2023
Amount
GALVANIZED STEEL CHAIN LINK FENCE Line Wire – Galvanised steel wire of 3.15 mm diameter Fabric Size – 100x100 mm Height – 150 cm Line Wire – 2 numbers of line wires of 4.00 mm diameter Standard- Conforming to IS-2721-2003, with up to date amendments
RCC FENCING POLES HIGHT 2.0 M Type – Straight Lenght – 2.00 m Dimensions – Bottom 10x10 cm square, Top 8x8 cm square Cement Concretc Mix – Cement, sand and metal ratio 1:2:4, with 12.5 nominal size coarse aggreate. Sand used should be free from clay and salt, concrete mix shall be conforming to grade M-15 of IS: 456:2000 Reinforcement – 4 round vertical bars of 6 mm diameter. 11 No of stirrups of 6mm diameter round MS bare 20 cm centre to center. Hooks- 5 no. bottom hook should be provided 60 cm above the bottom of the pole. second at 82.5 cm, third hook at 112.5 cm, fourth hook at 150 cm, top and fifth hook at 195 cm from bottom. Manufacturing- In order to ensure desired compressive strength, RCC fencing poles should be compacted with the help of platform vibrators. Surface should be uniform and free from voids. The concrete cover over the reinforcement should not be less than 1.5 cm
ALI AGRO
SHARAD FURNITURE MART
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .