Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹51.9 L+₹1.1 L (2.18%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹52.7 L+₹1.9 L (3.83%)Rejected-Finance | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹52.9 L+₹2.2 L (4.25%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L4 | Rejected-Finance Other than lowest. |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
14 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adampur
Military Engineeer Services AF Stn Adampur 144103
SPL REPAIR / REPLACEMENT OF ELECTRIC SUPPLY TO SMQ AT CAMP AREA AF STN ADAMPUR
2023_MES_576479_1
GE/AF/ADM-62/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Adampur
Refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE AF Adampur
₹98,000
Yes
24 Feb 2023
21 Jan 2023
15 Feb 2023
1 Feb 2023
14 Feb 2023
1 Feb 2023
21 Jan 2023 - 31 Jan 2023
Amount
Excavation in trenches n. exc 1.5 m wide for foundations, laying cables / pipes etc. not exceeding 1.5 m deep and getting out in soft/ loose soil complete, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified.
Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete, all as specified.
Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
Plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping to poles poles, bases of out door panel boards etc., including ncessary form work with fair finishing surface of concrete complete, all as specified.
Factory made unreinforced pre-cast concrete cover block HV type-1 flat of size 300x180x40mm laid flat and dry in trenches over the cable for protection as length perpendicular to the direction of cable adjacent to each other IN REPLACEMENT complete, all as specified.
Boring holes under road pavement / hardstanding by trenchless technology using ultrasound technique and necessary machine for inserting & including 80-100 mm bore HDPE pipe complete, all as specified.
GI pipe light grade with all fittings fixed as termination post, fixed to poles/ walls/ laid under floors or roads etc complete, including taking town existing pipe, all as specified of following size: -
40mm bore
50mm bore
DWC (Double wall corrugated) HDPE pipe laid in trenches for protection of cable/ earth strip and like with necessary connecting acessories like snapfit coupler etc. complete all as specified of following size: -
40 mm internal dia
50 mm internal dia
80 mm internal dia
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing complete, IN REPLACEMEMT,all as specified of sectional area: -
25 Sq.mm,4 core
50 Sq.mm,3.5 core
70 Sq.mm,3.5 core
95 Sq.mm,3.5 core
120 Sq.mm,3.5 core
185 Sq.mm,3.5 core
NOTE: Excavation and earth work, sand cushioning, protection cover & protection pipe shall be measured and paid for separately.
LT panel board, outdoor type, CPRI approved all as specified in particular specifications of contract clause 19.15 including installation, commissioning & testing, comprising the following components/acessories, IN REPLACEMENT: - (a) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and other parameter rating Amp upto 300A & volt upto 500V -01 Set. (b) LED indicating lamp for R,Yand B phases-01set (set of three) (c) Internal power & control wiring with suitable size PVC insulated multistranded copper wire (d) Almn bus bar of 300 Amp capacity, 4 strip mounted on porcelain insulators. (e) MCCB 4 pole, 415 volt, 200 Amp, 36 kA -01 No. (Incomming) (f) MCCB 4 pole, 415 volt, 100 Amp, 25 kA - 04 Nos. (Outgoing). (g) MCCB 4 pole, 415 volt, 63 Amp, 16 kA - 03 Nos. (Outgoing).
Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable of size 2.5 Sq. mm (nominal area), including PVC insulated unsheathed stranded copper conductor single core FRLSH cable of size 2.5 Sq. mm (nominal area) as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with base frame and cover plate of required module (suitable for modular switch/sockets) for one socket outlet three pin, 6/16 Amp, independent, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of BoQ. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
Modular switch, one way, 16 Amp, complete all as specified.
Modular socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete, all as specified.
Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
2 runs of 10 Sq. mm main cable + 1 run of 10 Sq. mm earth cable
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit, 25 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -
SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type complete.
VTPN, 4 way with 200 Amp rated bus bar, 415 V, double door type having housing and including MCCB 4 pole 100 Amp, 25 kA complete.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 63 Amp complete all as specified.
MCB suitable for 415 volt AC supply, four pole with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 63 Amp complete all as specified.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified.
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified.
Northern cable fault locatoers
R K ENTERPRISES
J.K & Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .