29 conditions · 9 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a) Attested Certificates(s) issued by Executive or Nominated Authority of the government Departments or Semi-Government/Public Sector Undertakings for the value of the work done for them during the qualifying period including current financial year certifying the bill amounts paid Agreement-wise and Date-wise or attested photo copy of such certificate. Such certificates will be accepted only from Govt. / Govt. bodies / PSUs authorities. Certificates issued by Private Bodies will not be considered.
(b) Audited Balance Sheets clearly indicating contractual receipts from the works done for Govt./ Govt. bodies / PSUs/Pvt. Organization in the P&L Account of the balance sheet duly certified by the Chartered Accountant for the completed & current Financial years.
NOTE: (i) Financial Year shall normally, be reckoned as 1st April to 31 st March of the Next Year. However, for Turnover Criteria, the Financial Year as applicable to the Company /Tenderer is to be considered, if it defers from the above. (ii) Current Financial year is reckoned as the incomplete Financial year in which the date of tender submission falls. (iii) Chartered Accountant statements duly indicating yearly receipts will not be considered until and unless backed by Audited Balance Sheets. (iv) If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
If JV firms are allowed to participate; Financial eligibility of the JV Firm shall be adjudged based on satisfactory fulfilment of the Para No.17.15.2 of part-I of IRSGCC- 2019 for J.V guide lines (with upto date correction slip).
NOTE: If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
The individual / firm should have minimum valid "B" grade electrical license or above and should be on their own name/Firm name issued by the Competent Authority. A copy of license should be uploaded through IREPS with their offer, failing which the tender will be rejected.
Similar Nature of work: "Works of wiring/cabling or installation and commissioning of electrical items (other than on coaches) such as lights, fans, pumps, charging arrangements, earthing etc (with or without supply of items/equipments) for 230V, 1phase or 415V, 3phase system or higher voltages" a copy of similar nature of work should be uploaded through IREPS with their offer, failing which the tender will be rejected.
94 conditions · 10 needing a document upload
TENDER SHALL BE REJECTED if it is not accompanied by the following:
Cost of tender document & EMD deposited through IREPS e- payment
In case of Partnership firm : The tender form shall be submitted only in the name of partnership firm.
In case tenderer is JV Firm : The tender form shall be submitted 1.1.2 only in the name of the JV and not in the name of any constituent member.
Uploading of Certificate in support of Technical Eligibility (As detailed in Standard Technical Criteria).
Submission of Certificate(s) in support of Financial Eligibility (As detailed in Standard financial criteria).
IN CASE OF ADVERTISED TENDER VALUE IS MORE THAN RS. 20 CRORES: Bid capacity is applicable, the tenderers should submit proforma attached in DOCUMENTS. In case, the tenderer/s failed 1.3.1 to upload BID CAPACITY PROFORMA along with offer, their/his offer shall be considered as incomplete and will be rejected summarily.
In case tenderer is other than sole proprietorship firm, following documents shall be uploaded by the tenderer:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered). [iv]An undertaking by all partners of the partnership firm that they are not blacklisted or 1.4.1 debarred by Railways or any other Ministry / Department of the Govt. of India / any State Govt. from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 1.4.2 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company; and (ii) A copy of 1.4.3 Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iv) copy of PAN number of the Company.
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 1.4.4 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Incase JV Firms are allowed to participate: Uploading of MEMORANDUM OF UNDERSTANDING as per the format given in "Documents attached with tender" and also below documents.
In case one or more members is/are Proprietary Firm or HUF, the following documents shall be enclosed:: A copy of notarized affidavit on Stamp Paper declaring that his/her Concern is a 1.5.1 Proprietary Concern and he/she is sole proprietor of the Concern OR he/she is in position of "KARTA" of Hindu Undivided Family (HUF) and he/she has the authority, power and consent given by other partners to act on behalf of HUF.act on behalf of HUF.
In case one or more of the members of the JV is/are partnership firm(s), following documents shall be submitted:]:(a)A copy of the Partnership Deed, (b)A copy of consent of all the partners or individual authorized by partnership firm, to enter into the Joint 1.5.2 Venture Agreement on a stamp paper, (c)A copy of Power of Attorney (duly registered as per prevailing law) in favour of the individual to sign the MOU/JV Agreement on behalf of the partnership firm and create liability against the firm.
In case one or more members of the JV is/are companies, the following documents shall be submitted: (a)A copy of resolutions of the Directors of the Company, permitting the company to enter into a JV agreement, (b) A copy of Memorandum and 1.5.3 Articles of Association of the Company. (c) A copy of Authorization/copy of Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender, sign MOU/JV Agreement on behalf of the company and create liability against the company.
IN CASE THE TENDER VALUE MORE THAN RS. 50 LAKHS; Tenderers shall submit a notarized affidavit on a non-judicial stamp paper stating that all their statements / documents submitted along with bid are true and factual.
Uploading of Declaration regarding Employment of Retired Engineer/Retired Railway Officer as per clause no.17 of Part-I of IRSGCC. [in the format attached in - Documents]
Uploading of NEFT FORM - as per the format attached with the tender document.
The list of personnel / organization on hand and proposed to be engaged for the tendered work.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work.
Uploading of Statement Showing the particulars of Works on Hand & Works Completed as per the format attached to the tender document.
Uploading of certificate by local suppliers in regard to meeting the Minimum Local Content requirement to avail benefits under Public Procurement Policy Order-2017 (A) for procurement order of value less than Rs. 10 crores: self certificate in accordance with Para-9(a) of Public Procurement(Preference to Make in India) Order 2017. (B) For Procurement Order of value more than Rs. 10 crores, the certificate from Statutory auditor/cost auditor/practicing CA as the case may be in accordance with Para-9(b) of Public Procurement (Preference to Make in India) Order 2017.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
IN CASE OF SINGLE PACKET TENDERS; CONSORTIUM AGREEMENTS, JOINT VENTURE FIRMS AND MOUS SHALL NOT BE CONSIDERED
IN CASE OF TWO PACKET TENDERS CONSORTIUM AGREEMENTS AND MOUS SHALL NOT BE CONSIDERED . BUT JOINT VENTURE FIRMS ARE CONSIDERED FOR ELIGIBILITY.
CONDITIONS FOR PARTICIPATION OF PROPRIETARY FIRM / PARTNERSHIP FIRM /PRIVATE LIMITED COMPANY / LIMITED COMPANY/ JV FIRMS:
In case the tenderer is an individual / proprietary concern, the experience and turnover shall be in the name and style of the Individual / Proprietary concern only.
In case the tenderer is a Partnership Firm, the experience and received contractual payments shall be in the name and style of the firm only. The other guidelines at Clause 18 of Part I of 4.1.1 IRSGCC shall be applicable . Note: The partner of a Partnership Firm cannot claim the credentials of Partnership firm to the extent of his share either during the subsistence of the Partnership firm or after its dissolution.
FOLLOWING DOCUMENTS SHALL BE ENCLOSED:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create 4.2.1 liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered).
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) and AOA (Articles of Association) of the company; and (ii) A copy of Authorization/Power of Attorney issued by the Company 4.2.2 (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iii) copy of PAN number of the Company.
In case of JOINT VENTURE (JV) FIRMS: Clause No.17 of Part-I of IRSGCC with upto date correction slip shall be applicable in all aspects for Participation of Joint Venture[JV] firms in works tenders. JV firm should submit Memorandum of 4.2.3 Understanding[MOU] as per the format attached as annexure to the tender in DOCUMENTS. Submission of all other documents by JV firm / Members of JV should also be as per Cl.No.17.14 of Part-I of IRSGCC.
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 4.2.4 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 4.2.5 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Uploading of other relevant documents connected to the tender; such as Declaration regarding employment of Retired Engineer/ Retired Railway officer, NEFT Form, List of Personnel/Organization, List of Plant/machinery, Particulars of works on hand and completed (As per the formats attached in the list of Documents)etc.
Hyderabad Division: 1) Replacement of old distribution panels in Central Hospital, Lallaguda with advanced switch gear for safety and reliability 2) Extension of AT Supply to the 30% Lighting Circuit of FOB, COP & SS Rooms over the division.
03-OEW-25-26-SrDEE-M-HYB
03-OEW-25-26-SrDEE-M-HYB
Open
Works - General
12 Months
Hyderabad, Telangana
₹0
₹2.3 L
8 May 2025
11 Apr 2025
130 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 69,80,003 | ||
| — | 5.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 6 way TPN DB in surface/concealed with IP 56 protection & comprising of 2 x 63A 4P 300mA RCBO, 18 x 6/10/16/20/32A MCB SP with Double door, flush mounting, similar to Legrand make as per the directions of engineer at site. | — | — | — | 69,865 | |
| — | 5.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 8 way TPN DB in surface/concealed with IP 56 protection & comprising of 2 x 63A 4P 300mA RCBO, 24 x 6/10/16/20/32A MCB SP with Double door, flush mounting, similar to Legrand make as per the directions of engineer at site. | — | — | — | 71,640 | |
| — | 450.00 | — | — | ||
| Supply of 4core 400 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 | — | — | — | 10,81,800 | |
| — | 450.00 | — | — | ||
| Laying of 4 core 400 sq.mm multi strand LT XLPE cable, connecting with suitable glands connectors etc. Testing and commissioning of LT XLPE cable as per directions of the engineer at site. | — | — | — | 66,600 | |
| — | 500.00 | — | — | ||
| Supply and commissioning of 4core 240 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest | — | — | — | 7,99,000 | |
| — | 500.00 | — | — | ||
| Laying and commissioning of 4core 240 mm² LT XLPE UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest | — | — | — | 48,500 | |
| — | 400.00 | — | — | ||
| Supply of 4 core 185sq.mm multi strand aluminum armoured LT XLPE cable confirming of IS 7098/Pt.I/1988 or latest | — | — | — | 4,39,600 | |
| — | 400.00 | — | — | ||
| Laying of 4 core 185 sq.mm multi strand LT XLPE cable, connecting with suitable glands connectors etc. Testing and commissioning of LT XLPE cable as per directions of the engineer at site. | — | — | — | 30,400 | |
| — | 300.00 | — | — | ||
| Supply of 4core 120 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 2,35,200 | |
| — | 300.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4 core 120 sq.mm multi strand LT XLPE cable as per directions of the engineer at site. | — | — | — | 15,000 | |
| — | 300.00 | — | — | ||
| Supply of 4core 70 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 1,68,000 | |
| — | 300.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4 core 70 sq.mm multi strand LT XLPE cable as per directions of the engineer at site. | — | — | — | 9,900 | |
| — | 300.00 | — | — | ||
| Supply of 4core 25 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 67,500 | |
| — | 300.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4 core 25 sq.mm multi strand LT XLPE cable as per directions of the engineer at site. | — | — | — | 3,300 | |
| — | 200.00 | — | — | ||
| Supply of 4core 16 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 36,400 | |
| — | 200.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4 core 16 sq.mm multi strand LT XLPE cable as per directions of the engineer at site. | — | — | — | 1,800 | |
| — | 2770.00 | — | — | ||
| Supply & laying of 8 SWG G.I. Wire along with LT XLPE cable. | — | — | — | 24,930 | |
| — | 1100.00 | — | — | ||
| Excavation of cable trench in all types of soils for LT cable as per the directions of engineer at site | — | — | — | 1,43,000 | |
| — | 900.00 | — | — | ||
| Cutting of asphalted road/ concrete/ cement and excavation of cable trench 30cm widex90cm, deep road, etc., for laying of LTUG cable. After laying of cable, the trench should be brought to its original position by providing tar/concrete/cement as per the site conditions and as per directions of Rly. Engineer. | — | — | — | 1,94,400 | |
| — | 100.00 | — | — | ||
| Supply of 50 mm dia "B" class G.I. pipe and fixing with suitable clamps on rail posts/walls including bends, couplings, etc., laying of cable through G.I. pipe as per the directions of Engineer at site. | — | — | — | 89,300 | |
| — | 100.00 | — | — | ||
| Supply of 100 mm dia "B" class G.I. pipe and fixing with suitable clamps on rail posts/walls including bends, couplings, etc., laying of cable through G.I. pipe as per the directions of Engineer at site. | — | — | — | 1,30,700 | |
| — | 400.00 | — | — | ||
| Supply & erection of HDPE pipe of 50 mm dia, PN-6, PE-100 of material grade as per the directions of Engineer at site | — | — | — | 72,000 | |
| — | 1600.00 | — | — | ||
| Supply & erection of HDPE pipe of 110 mm dia, PN-6, PE-100 of material grade as per the directions of Engineer at site | — | — | — | 6,96,000 | |
| — | 2.00 | — | — | ||
| Supply of earth pit materials and construction of earth pit as per IS 3043:1987 specification. This item also includes of supply and erection of CI pipe of size of 100mm inner diameter, 13mm thickness and 3000mm length. This work also includes of fabrication and fixing of GI strips for earthing connection. Excavated earth pit should be filled by mixture of coke/charcoal, salt and sand up to top. Provision of brick masonry chamber of size 650mmx650mm and depth upto 1000mm including light type CI cover frame and applying 12mm thick cement plaster in 1:3 inside and to all the exposed faces up to 300mm below. Foundation level, curing, etc. All required materials for this job such as CI pipe cover with frame, salt, cement sand, charcoal gravel, bricks, etc., required bolts, nuts and double washers, number plates or painted plates. Tentative quantity of salt and charcoal shall be of 2.5CMt. The CI pipe should be painted with 2 coats of bitumen paint as per the directions of Rly engineer at site. Note: The work should be strictly done as per IS 3043:1987 specification or latest. | — | — | — | 17,400 | |
| — | 8.00 | — | — | ||
| Supply and erection of earth electrode (as per RDSO Drawing No.ETI/OHE/P/7021 & RDSO Spec no. TI0LKO(PSI)@47&47@2020 Dt:25.08.2021 or latest) | — | — | — | 53,040 | |
| — | 120.00 | — | — | ||
| Supply, fixing, connecting & commissioning of GI strip of size 25x3 mm as per the directions of the engineer at site. | — | — | — | 8,160 | |
| — | 2.00 | — | — | ||
| Design, fabrication, supply, fixing, connecting, testing and commissioning of steel sheet iron cubical type 14 SWG Outdoor IP65 rated Main distribution board with the following switches/ MCCBs including sectionalized copper bus bar of capacity 600 Amps (copper bus bar should be RYBN uniform sizes) along with 1 No. Multifunction meters (bidirectional) and 0.2S class CTs with RS485 port and RYB LED indication lamps with control MCBs and all other connected accessories etc., 2 x 315 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault along with 315A On load COS, 5 x 200/250 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC (Short circuit), Ground fault, 3 x 125/160 A 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault 1x63A 10KA FP MCB, 2x32A 10kA FP MCB, 2x32A 10KA DP MCB Note: 1) All MCCBs should be Microprocessor only 2) ICs=100% Icu and all cables terminations to be done along with double compression glands and required lugs as per the direction of Engineer at site. | — | — | — | 8,90,312 | |
| — | 1.00 | — | — | ||
| Supply of Professional infrared thermal camera imager for hot spot and cold spot tracking with minimum of 2.2 inch colour LCD display, visual camera of 48608 pixels, selectable colour palette, Image Capture Frequency of atleast 9 Hz, Thermal Sensitivity of 150 mK, Operating Temperature of 0 C to 50 C , Measurement Range of -20 C to 300 C, Accuracy of ± 2 C or ± 2 % (Whichever is better), with SD Card Storage of minimum 4 GB, Memory Review option, USB Interface for charging and downloading images, Rechargeable Li-Ion Battery with warranty of atleast 2 years including battery, USB Mains charger, Charger Adapter, USB Lead, Micro SD Card, SD Card Adapter and calibration certificate similar to model No Meggar TC321 | — | — | — | 1,10,507 | |
| — | 2.00 | — | — | ||
| Design, fabrication, supply, fixing, connecting, testing and commissioning of steel sheet iron cubical type 14 SWG Outdoor IP65 rated Main distribution board with the following switches/ MCCBs including sectionalized copper bus bar of capacity 400 Amps (copper bus bar should be RYBN uniform sizes) along with 1 No. Multifunction meters (bidirectional) and 0.2S class CTs with RS485 port and RYB LED indication lamps with control MCBs and all other connected accessories etc., 2 x 200/250 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault along with 200A On load change over, 4 x 125/160 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault, 2 x 100 A 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault 1x63A 10KA FP MCB, 2x32A 10kA FP MCB, 2x32A 10KA DP MCB Note: 1) All MCCBs should be Microprocessor only 2) ICs=100% Icu and all cables terminations to be done along with double compression glands and required lugs as per the direction of Engineer at site. | — | — | — | 6,54,912 | |
| — | 1.00 | — | — | ||
| Design, fabrication, supply, fixing, connecting, testing and commissioning of steel sheet iron cubical type 14 SWG Outdoor IP65 rated Main distribution board with the following switches/ MCCBs including sectionalized copper bus bar of capacity 800 Amps (copper bus bar should be RYBN uniform sizes) along with 1 No. Multifunction meters (bidirectional) and 0.2S class CTs with RS485 port and RYB LED indication lamps with control MCBs and all other connected accessories etc., 2 x 400 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault along with 400A On load change over, 4 x 200/250 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault, 2x125/160 A 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault 6x63A 10KA FP MCB, 10x32A 10kA FP MCB, 4x32A 10KA DP MCB Note: 1) All MCCBs should be Microprocessor only 2) ICs=100% Icu and all cables terminations to be done along with double compression glands and required lugs as per the direction of Engineer at site. | — | — | — | 5,41,517 | |
| — | 200.00 | — | — | ||
| Supply, fabrication and installation of MS checker plates of 6mm thickness along with channels and all connected accessories as per directions of engineer at site | — | — | — | 33,000 | |
| — | 5.00 | — | — | ||
| — | — | — | 32,500 | ||
| — | 20.00 | — | — | ||
| — | — | — | 96,220 | ||
| — | 20.00 | — | — | ||
| Construction & providing of Cable trench covers with 1:2:4 RCC concrete as per the directions of engineer at site. | — | — | — | 27,600 | |
| — | — | — | 86,29,372 | ||
| — | 9000.00 | — | — | ||
| Supply & laying of PVC conduit pipe of 25 mm dia 2 mm thick in concealed as per the directions of Engineer at site | — | — | — | 2,79,000 | |
| — | 2000.00 | — | — | ||
| Supply & fixing of PVC Conduit moulded bend pipe 32/25 mm dia 2 mm thick in concealed | — | — | — | 56,000 | |
| — | 500.00 | — | — | ||
| Supply & fixing of PVC junction box of suitable way for 32/25 mm dia 2 mm thick PVC conduit pipe in concealed | — | — | — | 12,500 | |
| — | 15000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 1.5 sq. mm FRLS Cu. Conductor. | — | — | — | 2,55,000 | |
| — | 13000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 2.5 sq. mm FRLS Cu. Conductor | — | — | — | 3,64,000 | |
| — | 10000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 4 sq. mm FRLS Cu. Conductor | — | — | — | 4,40,000 | |
| — | 6000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 6 sq. mm FRLS Cu. Conductor | — | — | — | 5,64,000 | |
| — | 2000.00 | — | — | ||
| Supply, laying, connecting & commissioning of three core multi strand 1.5 sq. mm FRLS Cu. Conductor | — | — | — | 1,16,000 | |
| — | 2000.00 | — | — | ||
| Supply and erection of ceiling rose. | — | — | — | 42,000 | |
| — | 400.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 32 A DP RCCB with 30 mA Residual Capacity as per direction of engineer at site. | — | — | — | 11,34,000 | |
| — | 100.00 | — | — | ||
| Supply & erection of 3 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 6,100 | |
| — | 100.00 | — | — | ||
| Supply & erection of 3 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 7,700 | |
| — | 60.00 | — | — | ||
| Supply & erection of 6 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 5,760 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NEFTForm.pdf
ATTACHMENT
ExperianceCertificate.pdf
ATTACHMENT
GCC_April-2022_2022_New.pdf
ATTACHMENT
CorrectionSlip2022_CE-I_CT_GCC-2022Policy14.07.2022_1.pdf
ATTACHMENT
ACS-3toGCCApril.2022RBCE_CE-I-CT2023_04_26.pdf
ATTACHMENT
ACS-2toGCC-2022-CE-1-CT-GCC-2022-POLICY_13.12.2022.pdf
ATTACHMENT
ApprovedTB3-25-26Panel.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .