Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.9 L+₹69,018 (4.01%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹18.0 L+₹75,908 (4.41%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹18.1 L+₹90,428 (5.26%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹18.5 L+₹1.3 L (7.53%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
24 Jan 2022, 6:00 pmClosed
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR/MAINT ELECTRIC LT CABLE AND INDOOR TYPE PANELS AT SWC HQ BUILDING AT JAIPUR MIL STN
2021_MES_497756_1
GE/J-47/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JAIPUR
As per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹50,000
Yes
14 Mar 2022
28 Dec 2021
26 Jan 2022
28 Dec 2021
24 Jan 2022
11 Jan 2022
28 Dec 2021 - 10 Jan 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L for sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying complete all as specified in SSR Part-II
M&L for bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete
Dismantling and taking out UG cable any size unserviceable items fixed in any position and removal from site, all as directed.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 Sqmm nominal cross section 4 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed.
All as per Item No. 7 above but of size 25 Sqmm nominal cross section 4 core.
All as per Item No. 7 above but of size 35 Sqmm nominal cross section 3.5 core.
All as per Item No. 7 above but of size 50 Sqmm nominal cross section 3.5 core
All as per Item No. 7 above but of size 70 Sqmm nominal cross section 3.5 core
All as per Item No. 7 above but of size 95 Sqmm nominal cross section 3.5 core
All as per Item No. 7 above but of size 120 Sqmm nominal cross section 3.5 core
All as per Item No. 7 above but of size 150 Sqmm nominal cross section 3.5 core.
All as per Item No. 7 above but of size 185 Sqmm nominal cross section 3.5 core.
All as per Item No. 7 above but of size 240 Sqmm nominal cross section 3.5 core.
S & F in replacement molded case circuit breaker (MCCB) front operated switch disconector wirh extenderd shaft and IP 65 FP 400 Amps 36 KA rupturing capacity 415 volts including all fitment assesuries , lugs and suitable size nut and bolt , drilling work as per required and electric connection, as per existing make and shape complete all as directed.
All as per Item No. 17 above but IP 65 FP 160 Amps 36 KA.
All as per Item No. 17 above but IP 65 FP 100 Amps 36 KA.
All as per Item No. 17 above but IP 65 FP 63 Amps 36 KA.
S & F in replacement molded case circuit breaker (MCCB) IP 65 TP 160 Amps 36 KA rupturing capacity 415 Volt incl all fitment assesuries , lugs and suitable size nut and bolt , drilling work as per required and electric connection,as per existing make and shape complete all as directed.
All as per Item No. 21 above but IP 65 TP 250 Amps 36 KA
S & F in replacement On Load change over switch front operated switch disconector with extenderd shaft and IP 65 FP 400 Amps 36 KA rupturing capacity 415 Volt incl all fitment assesuries , lugs and suitable size nut and bolt , drilling work as per required and electric connection,as per existing make and shape complite.
S & F in repair Butterfly Valve of 80 mm bore complete
S & F in repair Butterfly Valve of 50 mm bore complete .
S & F in repair Ball Valve of 32 mm bore complete .
S & F in repair Fire brigade inlet connection 2 way -
S & F in repair Fire brigade inlet connection 4 way -
S & F in repairs Sprinkler glass bulb type (Standard response) as Per IS:15105/TAC guidelines 79 degree temperature rating pendent type
S & F in repairs Sprinkler flexible pipe 1.5 mtr long
S & F in repairs MS ERW Pipe of 32 mm bore complete
S & F in repairs MS ERW Pipe of 50 mm bore complete
S & F in repairs MS ERW Pipe of 80 mm bore complete
Supply and fixing in replacement of LED indicator lamp Red , Yellow and Blue including wire and lugs etc complete
M&L for earthing with galvanized steel earth plate electrode 600mmx 600mmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32x6mm, by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No. 03 of SSR Part -I connected to earthing point , PCC pit in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40mm thick cover, watering arrangement with funnel and wire mesh and 20mm bore medium grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earh work including testing on completion.
S&F in repair single pointed air termination aluminium rod 12mm dia 300 mm long including nuts & bolts for fixing air termination rod to pole/ pipe duly insulated by providing appropriate insulator all as required at site.
M&L in replacement test point terminal block made of gun metal or phosphorpous bronze size 75x75x25 mm drilled and screwed including 3 nos 8 mm dia 25 mm long hex. head screw complete all as specified and directed by EIC.
Supply and fix in replacement aluminum strip 25x3.15mm as roof conductor or down conductor or along the pole/pipe complete with saddles/ insulators made out of porcelain or fibere and fixing screws all as required at site or directed.
Supply & fix in Replacement GI strip 32x6mm, buried in ground or fixed to wall etc for loop earthing.
Supply ,installation , testing and commissioning of LT panel board fabricated out of 2 mm thich powder coated CRC sheet with copper bus bar 4 pole equal of capacity in colour code R,Y & B1000 Amps 415 Volts indoor type floor mounted angle Iron Size not less then 1.5 mtr x 1.5 m x 0.3M installed on porcelain insulators with bus bar chamber. the panel shall be dust and vermin proof, protection class IP 42 class front opening & compartmental type with approach for cable entry and for easy maintinancce duly internally wired with FRLS , PVC insulated standerd copper cable of 2.0 Sqmm including LED indicator R,Y,B 3 Phase volt meter digital type and comprising of the following : Incoming MCCB 400 Amps 4 pole 36 Ka 415 Volts 70 to 100 % , 50 Hz Out going MCCB 250 Amps 4 Pole 36 KA 415 Volts 70 -100% , 50 HZ ----05 Nos
Supply and installed of 3 Phase Automatic Phase Sequence corrector of 50 Amp load capacity Complete
Supply and installed of 3 Phase Automatic Phase Sequence corrector of 20 Amp load capacity Complete
Supply and fixing of seprator and connector as per existing shape and size all as spesified and directed
Schedule of Credit
SHREE BHAGWATI ENTERPRISES
M/s Radhey Enterprises
JAGDAMBA CONSTRUCTION COMPANY
M/S Sheeba Enterprises
M/S Anil Enterprises
LAKSHMI ASSOCIATES
Bhawani Electricals
Stuti Trading Company
M/S JALANDRA CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .