Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹26.7 L+₹45,724 (1.74%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹27.7 L+₹1.5 L (5.54%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹28.0 L+₹1.7 L (6.59%)Rejected-AOC FLAT NO 1 PLOT NO 54 GRD FLOOR TULSI ASTHA NEAR SHRI ANAND RUSHIUDYAN SECTOR 12 VASHI NAVI MUMBAI 400 703 | THANE | MAHARASHTRA | 400703 | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹28.7 L+₹2.4 L (9.32%)Rejected-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L5 | Rejected-AOC Not Lowest |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
2 Sept 2022, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD,MUMBAI-400088
SPECIAL REPAIRS TO WATER TANK AND REPLACEMENT OF EXTERNAL WATER PIPE LINE AND PUMP SETS OF KV MANKHURD, UNDER GE (NW) MANKHURD
2022_MES_543584_1
8162/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (NW) MANKHURD
AS PER NIT TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹64,000
Yes
11 Oct 2022
5 Aug 2022
5 Sept 2022
5 Aug 2022
2 Sept 2022
19 Aug 2022
Amount
Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed.
M&L for 20 mm thick(12+8mm) polymer modified ready mixed cement plaster including necessary scaffolding up to 24 m height complete all as specified ( NOTE :- WPC shall be measured and paid separately).
Supply only integral water proofing compound
Chipping, removing carefully loose/damaged concrete incl plastering (total thickness upto 60mm ) from RCC surfaces of columns, beams,Chajas, soffits of slabs etc by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land, complete all as specified and directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement by sand blasting with suitable pump as directed by the GE and wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed . Note:- Mode of measurement: superficial area of concrete will be measured.
M&L for providing mild steel TMT bars in various structural RCC elements like column, beams and Slab etc. including cutting, bending, fixing the bars,welding with existing bars etc. complete all as specified and directed. Note: This item is applicable for additional bars required in the existing RCC structures.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Monolith-PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 60mm in thickness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. Note : Items no 8 to 11 has to be done proir micro concrete and shall be paid seperately (Note: Reinforcement only shall be measured and paid separately).
Material & Labour for applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
Drilling and fixing teflon noozzles in RCC Members , including , drilling holes , drilling 12 mm dia , 50 to 100 mm deep holes in structural members at the interval of 300 to 500 mm staggered manner or as directed by the consteltants in RCC structural element , cleaning of holes , clean the holes by air blower piror to fixing the noozles , fixing of noozeles insert 12 mm dia Teflon nozzels in cleaned holes ,External end of nozolles to be machine to recive outlet of grouting gun , fix it insiode the holes by applying thixotropic epoxy putty to ensure complete sealing , cure the system for min 12 hrs cutting of nozzles cut the nozzles by chisel after completion of grouting with out damaged structurel element
M & L for Grouting injecting low viscosity high moleculer weight thermosett /monopol or equivalent polymer by pressure and using injecter with accessorises till nozzles refused the accept the grout incliding , mixing of materials , mixing material components quantities as per mfg instruction by weight batching grouting fill the grouting gun with material maintain desired pressure in the gun air by compreser maintion thr pressure at exit ( 3 to 4 kg / cm2 ) by monitering pressure gauge at exit ., gout the material through pre fixed nozzles in the structurel elements till its refusal . seal the nozzles with putty after the refusal , moniter leakages through other nozzles while grouting and seal them as per requirement complete all as specfied and directed.
M & L for two coats of water proof paint inside OHT of approx 20.00 mtr of food grade paint materials from Pidilite, Dr Fixit or STP equivalent make all as specfied and directed
Dismantling of brick work /stone bouldersbuilt in cement mortar including all quins, arches, pillars etc complete all as specified and as directed.
M & L for brick work in CM (1:6) using sub class 'B' bricks strainght or or curved as curved as required on plan exc 6mtrs mean radius etc.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, as in wall etc complete all as specified & directed. Note: PCC bond stone and face work shall be measured and paid separately.
Extra over stone walling for hammer dressing to face stones with maximum depression on fair face from straight edge held against the dressed surface not exceeding 40 mm for granite or trap stone of face beds & joints as specified of random rubble walling uncoursed or brought upto course complete all as specified.
M& L for raised pointing to random rubble masonry uncoursed or brought upto courses in CM 1:6 , complete all as specified & directed.
Demolition of stone slabs and tiles laid beded and pointed in any mortar of any description or thicknes in floors , aprons etc
M&L 75 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded aggregate) AS in sub base of flooring complete all as specified and as directed
M&L 100 mm thick Cement concrete type B2, 1:2:4 (using 20 mm graded aggregate) AS in sub base of flooring complete all as specified and as directed
M&L Machine pressed precast concrete interlocking paver block Coloured any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over and including 25 mm thick sand cushion complete all as specified
Excavation in trenches,n.exc 1.5m wide and n.exc 1.5m in depth for foundation/ for laying of GI/DI water tubing etc and getting out in soft/loose soil any type of soil complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) as in foundations,filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B2(20mm graded aggregate) as in surface channels and drains complete all as specified & directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
M&L Stairs (framed) including stringers, treads, landing, balusters, hand rails etc, including cleats, brackets, etc witih ms Angle flat etc confirming to Fe- 410 Gde E. complete all as specified and as directed.
M & L two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of previously untreated surfaces of steel and iron exc 10 cm width or girth.
Supply , install, testing and commissioning of Monoblock Pump set with CI casing , high tensile steel shaft impeller, priming funnel with lock, electric driven of capacity 10 HP with discharge ranging from 12.5-6 LPS and head, ranging from 28-52 Mtrs directly coupled with three phase, 50 Hz, 415 Volts, squirrel cage induction motor of suitable capacity and including suitable PCC foundation, MS channel,bolts, nuts, anti-vibration pads, suitable suction and delivery pipe etc complete all as specified and directed. Make: Kirloskar/ Danfoss/ Crompton Greaves/ Havells
Returning filling in including spreading leveling watering and well ramming in layers not exc 25cm.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point.
M & L for DI fittings class K-12 conforming to IS:9523/2000 upto 100mm dia of any type, size, such as bend, tapper, tee piece, cross etc complete all as specified and directed.
Supply, lay/fix, connect and testing DI water tubing of 100 mm bore with spigot and socket ends class K-9 conforming to IS:8329/2000 in any length suitable for rubber tyton joint including one rubber joint laid in trench complete all as specified and directed. Make-: Electro Steel Casting
Supply, lay/fix, connect and testing steel water tubing of 100 mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings and fixtures,Clamps and fixed to wall/ceiling or laid on floors including taking down of old unserviceable pipe complete all as specified and directed. Make-: Electro Steel Casting
All as per item No 36 above but of size 80mm dia.
All as per item No 36 above but of size 50mm dia.
All as per item No 36 above but of size 40mm dia.
All as per item No 36 above but of size 25mm dia.
S&F in repair sluice valve 100mm bore, cast iron body, flanged and drilled end, conforming to IS-14846, ISI marked, class PN 1.6 including all joints with rubber or fibre board, gaskets, bolts and nuts, washers, iron wheel including taking up / down old unserviceable valves from any position and any addition / alteration for fixing required complete all as specified and as directed Make-: Kirloskar/ Leader/ Kartar/ VAG
S&F in repairs gunmetal gate or globe valve for 50mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed. Make -: Zoloto/ Leader/ Sai
All as per item No 42 above but of size 40mm dia.
Meterial and labour for construction of block masonary valve pit of size 100cmx100cmx100cm (internal dimension) and MS plate cover with angle iron frame, hings and locking arrangements and handle including necessary excavation in any type of soil, returning filling in and removal of surplus soil to distance not exc 50 mtr, rendering block masonary wall in cement motor (1:4) (internaly/externaly) and applying two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces after dismentling old unserviceable one all as speciffied and directed by Engineer -in -Charge
M&L for cutting existing road/hard standing not exc 45x50 cm in wide & depth getting out excavated material for laying water tubing returning filling & well ramming watering finish suraface 10 cm from top including provision of PCC 1:3:6 for repairing, including removal of surplase soil all as directed
S& F of HDPE pipe 150mm dia, PN-10 for laying in ground, road crossing etc for protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge
M & L for Rendering 15mm thick on fair faces of brick work or concrete surfaces cement plaster 1:6, all as specified and directed.
S & F in repair cast iron Ball Foot valve 100mm flange type model B-05 (N) conforming to IS with MS nuts bolts, washer, rubber gasket etc., any pattern as approved including taking out/ dismantling old unserviceable one and testing complete all as specified and as directed. Make : KIRLOSKAR/UPADHYAYA/LEADER/NORMEX/VENUS.
Supply, installation, testing and commissioning in repair of LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ,outdoor type,cubicle , dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet duly powder coated painting (7 tank process) , CPRI approved, hinged door, front and rear opening with locking arrangement, cable alleys, bus bar chamber and switch gear comparments, copper bus bar 200 Amps rating for three phases and 150 Amps for neutral duly covered with heat shrinkable sleeves colour coded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting MCCBs/switch gears with main bus bar by using copper bus links or copper conductor flexible wires of suitable rating and connecting with terminal blocks of appropriate rating by cable lugs, thimbles etc., earthing terminals, affixing danger notice plate, each compartment shall be numbered/lettered for indication and control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement and a clear space to be kept from bottom of panel for proper termination of cables and including cable connection to MCCBs, switch gears with necessary cable glands, lugs, nuts, bolts and washers etc., complete all as specified and directed including comprising of following:- (a) MCCB 100 Amps (Magnetic thermal setting type), 4 Pole, 25 KA, 415 Volts, AC, 50 HZ -01 No (Incoming) Make: Schneider/ ABB/ L&T/ Legrand (b) MCCB 32 Amps (Magnetic thermal setting type), 3 Pole, 16 KA - 02 Nos. (Out going) (d) MCB TPN 40 Amps -01 Nos.(Out going) Make: Legrand/ L&T/ Havells (e) MCB SPN 32 Amps - 02 Nos (f) Star Delta Starter for 10 HP Pump- 02 No. Make : L&T (g) Motor protection relay-02 No Make: C & S (h) LED indicator RYB- 03 Nos Make: C & S/ L&T (j) Time switch with contactor -1 No Make:C & S/ L&T (k) VAF meter - 1 No Make: AE/ Conserv/ Schneider The drawing of panel shall be got approved by GE before fabrication of panel.
Dismantling existing PVC water storage tanks and Supplying, hoisting and fixing rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) of 1000 Litres capacity with and including covers, hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes etc complete all as specified and as directed Make : Sintex
All as per item no 50.00 above but of capacity 2000 ltrs
All as per item no 50.00 above but of capacity 5000 ltrs
Supply and fix in repair PVC Ball valve 40mm bore ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. Make: Prayag
All as per item No 53 above but 55mm bore
Supply and fixing water pressure gauge 0-14 Kg/Sq cm including clamps, nuts, bolts & washers complete all as specified and as directed. Make: H-Guru
M&L for earthing complete with GI earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of GI Strip of size 32x6 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed. (1) 7.5 RM GI strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately (2) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI earth plate. Note : A sum of Rs 43,785.00 towards sch of credit shall be deducted to arrive the contract sum.
Shree Ayyappa Engineering
Parmatma Enterprises
M/s Shreeji Construction Co
mp construction co
A P ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .