Tender Value
₹5 Cr
EMD Value
₹10 L
Closing Date
22 Jun 2023, 5:00 pmClosed
Medical Superintendent cum Member Secretary, RMRS
SMS Hospital, Jaipur
Heart Valves
2023_SMSMC_334655_1
1370_06.05.2023
Open Tender
Miscellaneous Goods
Item Wise
730 days
SMS Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Medical Superintendent, SMS Hospital, Jaipur
₹10 L
Yes
SMS Hospital, Jaipur
9 Jan 2024
9 May 2023
23 Jun 2023
9 May 2023
22 Jun 2023
2 Jun 2023
15 May 2023
Mechanical Valve Moulded pivot: - Bileafleat prosthetic heart valve with moulded pivot made up pyrolytic carbon (mitral +aortic) opening angle 75 degree or more. Should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. Should be in use for more than 20 year and acceptability by cardiac surgeon.. Expiration Date should be 3 years from the date of purchase.
Mechanical Valve Open pivot design:- Bileafleat prosthetic Heart valve with open pivot made of pyrolytic carbon (mitral + aortic) of all sizes. Should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. should be in use for more than 20 year and acceptability by cardiac surgeon, low profile sewing ring made up of polyester, should be radio opaque during X-ray and fluoroscopy. Expiration Date should be 3 years from the date of purchase.
Mechanical Valve with pivot guard design:- Bileafleat prosthetic Heart valve with open pivot made of pyrolytic carbon (mitral + aortic) of all sizes. Should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. should be in use for more than 20 year and acceptability by cardiac surgeon, low profile sewing ring made up of polyester, should be radio opaque during X-ray and fluoroscopy. Expiration Date should be 3 years from the date of purchase.
Mechanical Valve:- Bileafleat prosthetic Heart valve with opening angle 85 degree or more made of pyrolytic carbon (mitral + aortic) of all sizes. Should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring, should be in use for more than 20 year and acceptability by cardiac surgeon. Low profile sewing ring made up of polyester, Should be radio opaque during X-ray and fluoroscopy. Expiration Date should be 3 years from the date of purchase.
Bileaflet Mechanical Valve All Size of bileaflet Mitral and Aortic Valve with continuously rotating leaflets (360.Degree) and Available with disposable sizers and holders. .Only latest version is acceptable. 17 to 33 sizes, pannus preventing mechanizam, and housing reinforced with titanium alloy stiffening ring.
Monoleafleat prosthetic Heart valve to fit into server sub valve or fusion made of polyethylene Disc and Haynes Alloy” with swing ring mad from knitted polyester of all size. Should have minimal gradient +Tax Extra across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve. Should be in use for more than 20 year and acceptability be cardiac surgeon. Low profile sewing ring made up of polyester. Should be radio opaque during X-ray and fluoroscopy. Expiration date should be 3 years from the date of purchase.
Triple composite procine Valve:- Must be CE (European Certificate to be submitted ) Or FDA approved . Mitral and aortic.
Bioprosthetic valve.:- Bovine pericardial valve with silicone rubber sewing ring, stented ( cobalt-chromium alloy material)
Bioprosthetic valve:- Bovine pericardial valve with glide technology (GT) and linx anticalcification (AC) designed for supra-annular placement in aortic position.
Bioprosthetic valve:- Triple composite bovine pericardial valve with elgiloy stent material for both mitral and aortic position. Should have Anti calcification treatment done. Should have tenting system for avoiding suture looping in mitral position. Should have sizes for aortic position from 19 to 25mm and for mitral position from 25 to 31mm.
BIEAFLET AORTIC VALVE WITH CONDUIT:-Should have double velour woven graft. Should be collagen impregnated to control hemostasis and reduce the hemorrhagic complications. Should have mechanical and bioposthetic heart valve with low pressure gradients. With pivot guard design and leaflet opening and 75 degree or more. Ciff design should enhance implantability.Should have minimum taper conduit to facilitate strong coronary anastomosis. Should not have any pleats to allow easier positioning and attachment of the coronary arteries. Wide range of sizes from 19mm-33mm.Dacron graft of 3mm
Bio prosthetic conduit valve to replace aortic root (Bio- bentall)
Stent less tissue heart valve (CE Certified) for mitral and aortic position with all the sizes available should be in clinical use with long term proven result.
Free style tissue heart valve with aortic conduit of all sizes for aortic position to replace aortic root, should be stent less, should have zero pressure preservation technique to given long term durability.
Annuloplasty rings annuloplasty rings for mitral and tricuspid annulus. All sizes should be available. It should be available in the following vatieties. A Flexible
Annuloplasty rings annuloplasty rings for mitral and tricuspid annulus. All sizes should be available. It should be available in the following vatieties. B Rigid
Annuloplasty rings annuloplasty rings for mitral and tricuspid annulus. All sizes should be available. It should be available in the following vatieties. C physiological
Annuloplasty rings annuloplasty rings for mitral and tricuspid annulus. All sizes should be available. It should be available in the following vatieties. D Incomplete Ring
Right ventricle to pulmonary artery conduit of all sizes. Both xenograft and prosthetic graft.
Suture less heart valve for aortic position and for Mitral position.
Trans catheter aortic valve replacement valve (TAVR). Self-ExpandingSize 19-27mm. should perform in both circular and elliptical annuli.
Trans catheter Mitral valve replacement valve (TAMR).
Arch aneurysm graft with elephant trunk surgery extension
Bovine pericardial valve with resilia tissue (V-Fit) technology.
Polyester Tubular Graft collagen impregnated sizes – 6*40, 7*40 and 8*40, MRI friendly
Polyester Tubular Graft Arch Aneurysm Graft All Sizes three branch and four branch
Bioprosthetic valve:- Triple composite bovine pericardial valve with elgiloy stent material for both mitral and aortic position. Should have Anti calcification treatment done. Should have tenting system for avoiding suture looping in mitral position. Should have sizes for aortic position from 19 to 25mm and for mitral position from 25 to 31mm.
Specifications for Tissue Heart Valves:- Porcine tissue heart valves for Aortic/Mitral Heart position available in all Sizes. Good Fluoroscopic Visibility. VIV Ready for Future Intervention. Lowest profile-9mm lowest in the market). Linx AC technology, with flexfit system reduces the rinse time.
SPECIFICATIONS FOR SEMI-RIGID Ring : Annuloplasty Rings for Mitral Position, all Sizes should be available It should be available in the following varieties Semi Rigid Ring.
Curved Leaflets Bileaflet Prosthetic Heart Valve with (Aortic & Mitral) Should be Curved Pyrolytic Carbon Leaflets Aerofoil Housing Profile Innovative Hinge Mechanism Titanium Housing coated with Carbofilm Soft Carbofilm coated swing ring Should have an opening angle of 80 Degree. Should be in use universally for atleast 15 years. Size 23-33mm in mitral &Size 17-27mm in aortic
Truly Supra Annular BileafletProsthetic Heart Valve (Aortic) Should be Pyrolytic Carbon Leaflets. Should be pivot ear design. Should Have Biolite carbon coated Dacron sewing cuff for biocompatibility. Rotatable Valve. Should Have pyrolite Housing with Titanium stiffening ring. Should have an opening angle of 78 Degree. Should have suture markers on sewing ring for better positioning of valve. Size 19-25mm.
PericardiumHeart Valvewith Carbofilm coated sewing cuff (MITRAL) The valve should be Bovine pericardium made of double sheet structure of Pericardium. The Leaflet of valve should be fixed on a flexible polymeric stent can tolerate under back pressure of 2.000mmHg The sweingcuff should be coated with Carbofilm to improve hemo-compatibilty. The tissue should be fixed with Glutraldehyde and then neutralized with Homocystic acid. It should be stored in a paraben solution and should not require rinsing of the valve. Size 25 to 31mm
Bovine Pericardium Heart Valve with Crown Design (Aortic The Leaflet of valve should be fixed on a flexible polymeric stent can tolerate under back pressure of 2.000mmHg 2. Low Profile Height 3. Sweing Cuff Diameter should be less 4.The tissue anti calcification treatment should be fixed with Octanediol solution 5. The tissue Used in the valve should be 100% Bovine Pericardium only. Size 19-29mm
Semi Rigid Annuloplasty Rings Mitral All Sizes The exclusive alloy core cell design is a laser-cut one-piece structure that enables annular dynamics mimicking those of a physiological annulus 2)Superelastic alloy core “remembers” its prefixed shape, meaning it returns to its original form even after being flexed back and forth 3)semi-rigid annuloplasty ring has been engineered to give the stability needed to support the annulus while ensuring flexibility of movement. 4) Should have Ease of implant with good visibility, placement, and attachment to ensure proper annular fit (5) Should be available in 24mm, 26mm, 28mm, 30mm, 32mm, 34mm, 36mm & 38mm
Native porcine tissue Valve (Mitral) Native Porcine valve with minimized muscle shelf Should have flexible PEEK polymer stent Should have AOA anti calcification treatment and supra annular implant position with cinch II implant system with automated deflection of stent posts.Should have low pressure fixation and long term usage data(Over 25 years) Mitral Sizes:25mm,27mm,29mm,31mm,33mm
Bovine paricardial Tissue Valve Aortic Bovine Pericardial interior mounted leaflet.Three laser cut bovine pericardial leaflets matched for thickness and deflection to provide consistent performance Should be AOA tissue treatment Should have two part PEEK frame-Flexible & deformation resistant Frame inpregnated with BASO4,MRI Compatible Soft & Pliable sewing Cuff. Sizes 19 to 27 mm.
Bovine Jugular Vein Pulmonary Valve Conduit Integrated Valve Conduit for reconstruction of RVOT Bovine Jugular Vein Pulmonary Valved Conduit Should be available in wide range of sizes Size 12mm,14mm,16mm,18mm
Annuloplasty ring (Tricuspid Ring) for for tricuspid Valve repair Should be rigid three dimentionsal annuloplasty ring incomplete in shape to avoid interference to conduction system Height should be less than 3.5mm Additional Septal lateral compression should have titanium core encapsulated with silicone and covered with polyester fabric. Sizes 32mm
DEV PHARMA
Meril Life Sciences India Pvt.Ltd.,
PAREKH INTEGRATED SERVICES PRIVATE LIMITED
RADIANCE MEDICAL SYSTEM
India Medtronic Pvt. Ltd.
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .