| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LQualified | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹4.7 L+₹73,231 (18.6%)Qualified 2 3 AMIT VIJAY APT CHSL KASTURBA CROSS ROAD NEAR BHANU PARK KANDIVALI WEST MUMBAI 400 067 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | L2 | Qualified MSE, MII, Category: General | |
| 3 | L3₹4.7 L+₹79,831 (20.2%)Qualified PLOT 16 1ST FLOOR NEAR RPS CHOWK MAHARSHI DAYANAND SARASWATI MARG SEC 88 FARIDABAD HARYANA 121002 | FARIDABAD | HARYANA | 121002 | L3 | Qualified MSE, MII, Category: General | |
| 4 | L4₹6.2 L+₹2.3 L (57.9%)Qualified 3 NEW TRIMURTY CO OP HOUSING SOCIETY INGOLE NAGAR WARDHA ROAD NAGPUR 440005 MAHARASTRA | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | L4 | Qualified MSE, MII, Category: General | |
| 5 | L5₹7.8 L+₹3.8 L (97.4%)Qualified OFFICE E2 MANALI ARCADE NEAR D MART PADMAVATI PUNE SATARA ROAD PUNE MAHARASHTRA 411009 PUNE MAHARASHTRA 411009 | PUNE | MAHARASHTRA | 411009 | L5 | Qualified MII |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
9 Aug 2022, 2:00 pmClosed
Visual inspection as per item descreption.
Rebound Hammer Testing as per item descreption. Non Destructive Testing as per item descreption.
Ultrasonic Pulse Velocity Test as per item descreption.
Carbonation Test as per item descreption.
Core Test as per item descreption.
Concrete electrical resistivity test as per item descreption.
PH value test as per item descreption.
Chemical analysis as per item descreption.
Slab Load Test as per item descreption.
Structural design and drawings as per item descreption.
Preparation of BOQ for repair and retrofitting with material specifications and quantity breakup.
Vetting of repair and retrofitting scheme from any Govt Engg College.
3639578
GEM/2022/B/2397992
Visual inspection as per item descreption.,Rebound Hammer Testing as per item descreption. Non Dest
45 days
Delhi; South West Delhi
Total value wise evaluation
BOQ
4 documents required · 4 mandatory
3 yrs
₹3 L
80%
Exempted
9 Aug 2022
30 Jul 2022
9 Aug 2022
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Visual inspection as per item descreption. | Structural assessment, Non destructive testing and repair and retrofitting design for residential building No P-13 and P-15 Servant Quarters at RR Hospital. There are two Identical blocks G plus 3 RCC framed structure The consultant carry out the following inspection at the site and shall be submittedd the documents Visual inspection, for surface damages, delamination, spalling, local weaknesses, etc and their damage classification. The visual inspection shall cover all the residential units and all the structural components, Visual inspection would be documented in the form of worksheets, photographic records, and distress over drawings, sketches etc All the observations shall be be tabulated duly giving reasons for observed damage and remedial measures for each type of distress and damage in conjection with NDT results | 2 | Nos | South West delhi | 45 |
| 2 | Rebound Hammer Testing as per item descreption. Non Destructive Testing as per item descreption. | Rebound Hammer For determining the estimated compressive strength of concrete and uniformity of concrete in terms of surface hardness as per IS 13311 Part 2 1992. Non Destructive Testing Non Destructive Evaluation of the structural elements by various tests at required locations and structural assessment based on these parameters | 100 | Nos | South West delhi | 45 |
| 3 | Ultrasonic Pulse Velocity Test as per item descreption. | Ultrasonic Pulse Velocity Test for ascertaining the quality of concrete, soundness and density of concrete, uniformity of concrete in terms of density as per IS 13311 Part 1 1992, ASTM C597 83, BS 6809 1981 and BS 1881 Part 203 and BS EN 13791. | 100 | Nos | South West delhi | 45 |
| 4 | Carbonation Test as per item descreption. | Carbonation Test Measurement of carbonation depth by phenolphthalein spray test at selected location on RCC members of the structures covered under the study to see the depth of carbonation as per BS EN 14630 2006, 13295 2004. Ratio of carbonation depth to cover depth is also measured to check the intensity of carbonation attack on steel bar. | 18 | Nos | South West delhi | 45 |
| 5 | Core Test as per item descreption. | Core Test Extracting the concrete core samples at select locations from RCC members of the structure covered under study and evaluating the properties fck value, grade of concrete in the laboratory from the core samples selected as per IS 456 2000, IS516 1959, IS 1199 2002 without encountering any steel reinforcement of RCC members at specified locations with portable power driven core cutting equipment | 20 | Nos | South West delhi | 45 |
| 6 | Concrete electrical resistivity test as per item descreption. | Concrete electrical resistivity test Conducting electrical resistivity test for estimation of likelihood of corosion based on electrical resisitivity values. | 33 | Nos | South West delhi | 45 |
| 7 | PH value test as per item descreption. | PH value test To draw samples of concrete and pH Value test to check alkanity of concrete as per relevant IS 456 2000, BS 8110. | 6 | Nos | South West delhi | 45 |
| 8 | Chemical analysis as per item descreption. | Chemical analysis To draw samples of concrete and carry out chemical analysis of the samples including measurement of Chloride Content | 4 | Nos | South West delhi | 45 |
| 9 | Slab Load Test as per item descreption. | Slab Load Test Load carrying capacity analysis and deflection measurement of any kind of slab of building as per IS 456 2000 | 2 | Nos | South West delhi | 45 |
| 10 | Structural design and drawings as per item descreption. | Structural design and drawings of the various components required to be strengthened reconctructed in the buildings , along with methdology of execution of repairs and retrofitting works. | 1 | Nos | South West delhi | 45 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3639578.pdf
GEM_BID
atc-structural-audit_2022-07-30-13-56-54_b9939402ecde0a133ff3f6f886278991.pdf
BOQ
boq-structural-audit_2022-07-30-13-56-54_ad499bc95f054defc3bb71c5f768168c.csv
BOQ
atc_23225c59-8499-43f5-9d1c1659169789801_rchandrakanth.542h@gov.in.docx
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .