Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹18.7 L+₹1.5 L (8.80%)Rejected-Finance BORBARUAH BAZAR A T ROAD DIBRUGARH ASSAM | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹21.2 L+₹4.0 L (23.0%)Rejected-Finance B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹21.9 L+₹4.7 L (27.5%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹22.9 L+₹5.7 L (33.3%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
23 Oct 2023, 6:00 pmClosed
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
REPAIR MAINT OF LT DISTRIBUTION PANELS FEEDER PILLAR BOX SERVO VOLTAGE STABILIZER UNDER GE DINJAN
2023_MES_615819_2
84216E8
Open Tender
Electrical and Maintenance Works
Item Wise
180 days
GE DINJAN
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE DINJAN
₹50,000
Yes
6 Nov 2023
3 Oct 2023
25 Oct 2023
3 Oct 2023
23 Oct 2023
11 Oct 2023
4 Oct 2023 - 7 Oct 2023
Amount
M & L for Serviceing and repairing of Oil Cooled Servo Voltage Stabilizer , by disconnecting of all incomming and out going cable , opening of top cover carefully, cleaning of motor , service connection ,gear pininon and replacement of minor spares such as fuse, diode, carbon brushs, holder, internal electrical wiring and electronic accessories and insulated properly by varnishing, greasing, CRC spraying, electrical connections, filtration of transformer oil, making electrical connection by replacing the consumable spares such as gaskets, rubber oil seals complete etc but other spares as listed here-in-after shall be replaced and cost of spare parts as supply only shall be measured and paid separately under relevent item after that testing of servo voltage stabilizer in presence of Engr-in-charge , complete all as specified and directed by Engr-in-Charge capacity servo voltage stabilizer 200 KVA thre phase.
All as per serial item no 01 here-in-before except for capacity 500 KVA 3 Phase.
Supply only Potentiometer.Make Volina/Hindustan/AE
Supply only Voltmeter (Digital).
Supply only Ampere Meter with (Digital)
Supply only P C B Holder. Make Volina/Hindustan/Servocon
Supply only Servo Motor 10 Kg Torque. Make Volina/Hindustan/Servocon
Supply only Servo Motor 20 Kg Torque. Make Volina/Hindustan/Servocon
Supply only Carbon Brush (20amps to 200 amps) Make Volina/Hindustan/Servocon
Supply only Carbon Holder & Spring. Make Volina/Hindustan/Servocon
Supply only Servo motor gear pinion. Make Volina/Hindustan/Servocon
Supply only Drive assembly 200/250 KVA per phase. Make Volina/Hindustan/Servocon
Supply only Digital Control Panel with Circuit board for high / low Voltage cut per phase suitable for 3 phase Voltage Stabilizer of capacity upto200/500KVA.
Supply only front control with wiring kit .Make Volina/Hindustan/Servocon
M&L rewinding of Dimmer Starter (Barrier) for 200 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Complete all as specified and as directed
M&L rewinding of Dimmer Starter (Barrier) for 500 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Complete all as specified and as directed
M&L Rewinding of Transformer assembly for 200 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge. Make Volina/Hindustan/Servocon
M & L for spray painting of Servo stabliser (any type power or distribution)) of capacity upto and including 200 kVA ( in situ ) outdoor type, installed and located at different sites in scattered area under the GE including the following: - (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) Spray painting with two coats of synthetic enamel paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed .
M & L for spray painting of Servo stabliser (any type power or distribution)) of capacity upto and including 500 kVA ( in situ ) outdoor type, installed and located at different sites in scattered area under the GE including the following: - (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) Spray painting with two coats of synthetic enamel paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed .
Supply only new Servo stabliser oil of dielectric strength not be less than 60 kV and conforming to IS-335 of 1993 for filling/ topping up oil of stabliser up to desired level complete all as directed.
Dehydration and filtration of existing servo stabliser oil of stabliser at different location with filtration machine and heating system to get the minimum di-electric strength of oil 60 kV minimum without disturbing the power supply system and refilling/ topping up /replacement of unserviceable stabliser oil complete all as specified and as directed.( Note: Stabliser oil required extra for filling/topping up shall be measured and paid separately under the relevant items of this schedule).
Disconnection of existing Air Circuit Breakers (ACBs), 3 Pole/4 Pole,manually/electrically operated, fixed/draw-out type, AC 440 Volts,breaking capacity 50-100 kA, rated current 800-2000 Amps, form all incoming and outgoing electrical connections,checking serviceability of each components viz. ON/OFF button,CTs, tripping coil, shunt trip device,auxillary switches,locking arrangement,safety shutter,arc shield etc., replacement of defective lugs,thimbles etc.,replacement of defective parts, through cleaning of ACB both internally and externally, reassembling of parts including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by the Engineer in Charge. (ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
M&L for Locable Trip Push Button (LTPB), complete all as per OEM's specifications.
M&L for Locable Trip Push Button Kit (3IC & 2 BC), complete all as per OEM's specifications.
M&L for Locking of ACB in Isolated Position (LIP) type C,complete all as per OEM's specifications.
M&L for Locking of ACB in any Position (LAP) type C,complete all as per OEM's specifications.
M&L for Racking interlock type CC, complete all as per OEM's specifications.
M&L for Racking Padlock Assembly, complete all as per OEM's specifications.
M&L for Door Interlock, complete all as per OEM's specifications.
M&L fot Mechanical operation counter, complete all as per OEM's specifications.
M&L for Mounting Kit for Front mounted counter in repair.
M&L for Shunt release, complete all as per OEM's specifications.
M&L for under voltage release, complete all as per OEM's specifications.
M&L for Earth fault Release, complete all as per OEM's specifications.
M&L for vertical terminal adaptors for draw out ACB, complete all as per OEM's specifications.
M&L for electronic timer adjustable type from 3 to 30 sec, Complete all as per OEM's specification.
M&L Double door feeder piller box of size o.7x0.7x0.5 m and provn for fixing of ACB of capacity 630 Amps including suitable size bus bar,connection, testing complete all as specified and directed.
S & F Synthetic Rubber insulated mats, (IS 5424) suitable for electrical shock safety for voltage upto 11 kv of sizes 2m x 1m and thickness not less than 12 mm all as specified and directed.
S & F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 15x20cm size
M&L plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed for the poles and stay.
M&L for plain cement concrete 1:3:6 type C1, (using 20mm graded stone aggregate) for coping of poles and stay including necessary form work complete all as specified and as directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the Galvanised iron earth wire 4.0mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agregates with 40mm thick cover of RCC (1:2:4) reinforeed with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 40x40x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering , perforated at botytom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filled 150 mm thick all around the earth plate test point made out of 40x8mm FI galvanised with fixing arraangement, funnel wire mesh and earth work in any type of soil returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
Material and labour for Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the Galvanised iron earth strip 32x6mm size by means of bolls, nuts, check nuts and washers of galvanised iron and earth strip protected by provision of GI medium grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agregates with 40mm thick cover of RCC (1:2:4) reinforeed with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 40x40x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filled 150mm thick all around each plate, test point made out of 40x8mm flat iron galvanised with fixing arraangement, funnel wire mesh and earth work in any type of soil returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electical plate -3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
S & F CT & PT as per existing ratio at site which can suitably fixed in existing ammeater & voltmeter of LT electrical pannel at site
Taking down existing old/unserviceable MCCBs of any description from LT panel board complete all as specified and directed.
S & F for MCCB, AC, 415 Volts, 50 KA breaking capacity, 4 Pole of rating 400 Amp, ices = icu = 100% with adjustable thermal & fixed magnetic setting, 70-100% complete fixed with LT panel board all as specified and directed. (Make :Havells/Legrand/indoasian or equivelant given in Appx B)
M&L On load change over switch 400 A with enclosure rated voltage 415V-AC 50 Hz,type FP fixed on wall with nut and bolt including taking down complete all as specified and directed .Make-Havells Cat No-IHCNFOO400 or equivelant given in Appx B
S & F for MCCB, AC, 415 Volts, 36 KA breaking capacity, 4 Pole of rating 250 Amp, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make : Havells/Legrand/indoasian or equivelant given in Appx B)
S & F for MCCB, AC, 415 Volts, 36 KA breaking capacity, 4 Pole of rating 200 Amp, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make : Havells/Legrand/indoasian or equivelant given in Appx B)
S & F for MCCB, AC, 415 Volts, 36 KA breaking capacity, 4 Pole of rating 160 Amp, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make :Havells/Legrand/indoasian or equivelant given in Appx B)
S & F for MCCB, AC, 415 Volts, 36 KA breaking capacity, 4 Pole of rating 125 Amp with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make :Havells/Legrand/indoasian or equivelant given in Appx B)
S & F for MCCB, AC, 415 Volts, 36 KA breaking capacity, 4 Pole of rating 100 Amp , with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make :Havells/Legrand/indoasian or equivelant given in Appx B)
S & F for MCCB, AC, 415 Volts, 25 KA breaking capacity, 4 Pole of rating 63 Amp , with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and directed. (Make : Havells/Legrand/indoasian or equivelant given in Appx B)
S & F MCB, SPN, 240 Volts, 5 to 32 Amps, 'C' Series, capacity complete all as specified and directed. (Make: Legrand, Cat No. 408609 to 408617 or equivelant given in Appx B)
M&L Copper strip of size 32mm x 6mm including taking down old one complete all as specified and directed.
S&F in repaire for galvanised iron strip 32 x 6 mm buried in ground complete all as specified and directed.
Material and labours for spray painting only external surfaces of dimension n.exc 1.8 m x 1.4 m x 0.6 m to 1.0m x 0.9m x 0.6 m without taking down pannel accessoriesone and apply two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete including preparation of old surfaces of steel surfaces by scrapping, rubbing all as specified and directed.
Material and labours for panel reparing by welding/brazing etc making door to opening properly for any existing electrical panal all as specified and directed.
S& F in repair electric panel door lock of same type as per existing one with key all as specified and directed.
S & F in repair of PVC insulated aluminium bus bar into electric panel as per existing size and hole all as specified and directed.
Supply, installation, testing and commissioning of Outdoor LT Feeder Pillar ( with certification by CPRI / ERDA for IP 65) for SHOPPING COMPLEX of suitable size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and Copper bus bar of 450 Amps PVC insulated in step way for 3 phase 4 strip system fixed on hygroscopic base insulator including INCOMER: MCCB 400 Amps, 50 kA, 4 Pole in One (01) No, multifunction meter, LED Indication Lamps R/Y/B, OUTGOINGS: (i) 250A MCCB, 36kA, 4P - 1 No. (ii) 32A MCCB, 36kA , 4P - 1 No. (iii) 80A MCCB, 36kA, 4P - 1 No. (iv) 100A MCCB, 36kA, 4P - 3 Nos. (v) 40A TPN MCB - 2 Nos. (vi) 32A DP MCB - 2 Nos.,duly prewired with appropriate size of Copper bus bar thimbled (for accomodating outgoing cable connections) suitable size busbar chamber in order to accomodate all accessories with proper insulation with inlet and outlet cable provisions incorporated.
Supply, installation, testing and commissioning of Outdoor LT Feeder Pillar (with certification by CPRI / ERDA for IP 65) for SIGNAL UNIT of suitable size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and Copper bus bar of 450 Amps PVC insulated in step way for 3 phase 4 strip system fixed on hygroscopic base insulator including INCOMER: MCCB 400 Amps, 50 kA, 4 Pole in One (01) No, multifunction meter, LED Indication Lamps R/Y/B, OUTGOINGS: (i) 200A MCCB, 36kA, 4P - 3 Nos. (ii) 63A MCCB, 36kA , 4P - 1 No. as Outgoing feeder duly prewired with appropriate size of Copper bus bar thimbled(for accomodating outgoing cable connections) suitable size busbar chamber in order to accomodate all accessories with proper insulation with inlet and outlet cable provisions incorporated.
Supply, installation, testing and commissioning of Outdoor LT Feeder Pilar (with certification by CPRI / ERDA for IP 65) for OLD SIGNAL OFFICER MESS of suitable size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and Copper bus bar of 100 Amps PVC insulated in step way for 3 phase 4 strip system fixed on hygroscopic base insulator including INCOMER: MCCB 63 Amps, 50 KA, 4 Pole in one (01) No, multifunction meter, LED Indication Lamps R/Y/B, OUTGOINGS: (i) 40A MCCB, 36kA , 4P - 2 Nos. (ii) 40A DP MCB -2 Nos. duly prewired with appropriate size of Copper bus bar thimbled(for accomodating outgoing cable connections) suitable size busbar chamber in order to accomodate all accessories with proper insulation with inlet and outlet cable provisions incorporated
Supply, installation, testing and commissioning of Outdoor LT Feeder Pilar (with certification by CPRI / ERDA for IP 65) for DOI of suitable size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and Copper bus bar of 200 Amps PVC insulated in step way for 3 phase 4 strip system fixed on hygroscopic base insulator including INCOMER: MCCB 100 Amps, 50 kA, 4 Pole one (01) No., with multifunction meter and LED indication lamps R/Y/B OUTGOINGS: (i) 32 MCCB, 36kA , 4P - 1 No. (ii) 40A MCCB, 36kA , 4P - 1 No (iii) 63 MCCB, 36kA , 4P - 1 No (iv) 40A TPN MCB - 1 No. (v) 32A DP MCB - 4 Nos.as Outgoing feeder duly prewired with appropriate size of Copper bus bar thimbled (for accomodating outgoing cable connections) suitable size busbar chamber in order to accomodate all accessories with proper insulation with inlet and outlet cable provisions incorporated
Supply, installation, testing and commissioning of Outdoor LT Feeder Pillar ( with certification by CPRI / ERDA for IP 65) for CWE OFFICE of suitable size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and Copper bus bar of 200 Amps PVC insulated in step way for 3 phase 4 strip system fixed on hygroscopic base insulator including INCOMER: MCCB 160 Amps, 50 kA, 4 Pole in Two (02) Nos, 1 no. 160A COS, with multifunction meter, LED Indication Lanps R/Y/B OUTGOINGS: (i) 100A MCCB, 36kA, 4P - 4 Nos. (ii) Time Switch Feeder (32A TP MPCB) - 1 No. duly prewired with appropriate size of Copper bus bar thimbled(for accomodating outgoing cable connections) suitable size busbar chamber in order to accomodate all accessories with proper insulation with inlet and outlet cable provisions
Supply,Installation, commissioning and Testing of 33 KV Outdoor type Oil cooled current Transformer Ratio : 50/25/5-5A,Class -1.0,Burden : 15VA complete all as specified and directed by Engr-in -Charge.Make -Crompton Greaves or equivalent
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.
Boring under road without disturbing the top surface of the road and taxiway for passing throught the cable all as directed.(Note-Necessary infrastructure required for boring shall be arranged by the contractor at his owwn cost)
M&L for 100 mm dia steel tubes (light grade) galvanised with fittings laid in trenches /wall for protection of underground cable when crossing the road /fixing on wall complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV,type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and directed.
S&F Indication lamp set of three of colour Red , Yellow and Blue for LT Panel Board including taking out old one complete all as specified and directed.
Supplying and fixing of digital step indicator- EE- 610 of Make EMCO or equivalent make make given in Appx B complete all as specified and directed.
S&F 33 KV lightening arrestor of station class: 2.0, NDC, 10 KAP, PM Rel current - 40 KA of Make Cromptom Greaves or equivalent make given in Appx B complete all as specified and directed.
M/S Abhi Traders
Garg Brothers
ms singh construction
Shree Trilok Electric Corporation
M/s Singh enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .