Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-PreQual/Technical 69 IIIRD FLOOR POCKET C 7 SECTOR 7 ROHINI NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Not Admitted-PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-PreQual/Technical SCO 1785 DEEP COMPLEX HALLOMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | CHANDIGARH | Not Admitted-PreQual/Technical Not Complied with technical specification |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
25 Jul 2019, 6:00 pmClosed
GM RSRDC LTD JAIPUR
GM RSRDC LTD SETU BHAWAN, JHALANA DOONGARI, JAIPUR
SUPPLY OF WALK IN COLD ROOM RELATED TO FORENSIC DEPARTMENT FOR 100 SEATED MEDICAL COLLEGE, BHILWARA
2019_RSRDC_152817_1
RSRDC NIT NO.074 DATED 03.07.2019 SL.NO. 02
Open Tender
Civil Works
Item Rate
60 days
MEDICAL COLLEGE, BHILWARA
PLEASE REFER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹500
PD RSRDC LTD ELECT UNIT 1 JAIPUR THROUGH NEFT/RTGS
₹44,000
7 May 2020
5 Jul 2019
26 Jul 2019
5 Jul 2019
25 Jul 2019
8 Jul 2019
Amount
Walk in cold room
Specifications:-
Walk in cooler must be efficient and have high quality of insulation preferable polyurethane foam thickness 60 mm with 0.5 mm Stainless Steel 304 on outer and inner covering of walls/sealing having low thermal conductivity between 0.019 to 0.022 W/M° C.
Prefabricated PUF Panels to prepare a external room of size (L x W x H) 10 ft x 10ft x 9ft .
Cold Room temperature +2 to +8 Deg. C.
Pre fabricated PUF panels for floor with GI Antiskid flooring.
Supply of 1 No. flush type door along with door closer with 180 degree open facility.
Walk in cooler must be such that it may be shifted to different place easily without any major loss of room and cooling unit. Preferably made up of good quality cam locking system with metallic plunger should be provided to interlock each panels without using rivets or nails or any other fastening material. The Cyclopentane puf panels should be self extinguishing under ASTM: 1692 and the density of panels should be 40 +/- 2° 1g/m3. Corner panels should be provided for preparing neat and clean compact room. Firm should provide a undertaking from the principals for atleast 22% electrical savings from the normal PUF.
Heat Load: Please indicate the Heat Load in BTUH, minimum heat load shall be 10000. Air cooled condensing unit shall comprise of compressor. Condensing & evaporating unit shall be Quantity 2 Nos. (1 Working + 1 Stand by). The Refrigerant shall be R-404a/ 22.
Evaporator unit matching with condensing unit complete with coil section and suitable defrosting arrangement (Euro vent standard). Evaporating unit casing should be of SS-304. Quantity 2 Nos. (1 Working + 1 Stand by). Refrigerant R-404a/ R-22. Split type unit with 100% stand by
Refrigeration units shall be automatic without any operator
Safety equipment’s shall be incorporated
HP/LP cut out & Thermostat controlled unit.
Shall have Safety release lever to open the cold room from inside in case some person is locked inside the cold room.
Shall be Design at ambient temperature of 45 Deg C
Shall have Ozone friendly Cyclopentane blown foam at ± 2 Kgs. / Cubic Mtr.
High 90-95% closed cells.
Refrigerant piping shall be with cooper pipes, Drain piping and Suction Line Insulation.
Refrigerant controls shall includes
Thermostatic expansion valve.
Liquid line and filter drier.
HP/LP switches
Protection by thermostat
Electrical digital temperature indicator cum controller for auto cutoff system.
With vapor proof lighting in the room.
Heat load calculation should be submitted along with the tender documents.
Suitable stabilizer should also be supplied with both the unit.
The make and models offered along with design for compressor unit, condensing unit, evaporator unit and other items included in offer.
List of customers where such walk-in-type cold rooms units have been supplied & commissioned and performance certificates in last five years. It is essential that party must have supplied such cold rooms in past as per the qualification and eligibility criteria.
Service center should be based at Jaipur/Rajasthan. Service Center to attend the complaint within a period of 6 hours to prevent the damage to dead bodies/high value kits.
Firm should be liable to provide the breakdown service within 24 hours to prevent the storage of kits.
Firm should submit the list of users along with 10 performance certificate from the users from Institute of National Repute.
Firm will be responsible for complete installations.
Proper Stainless steel selves along the internal wall be provided for keeping bead bodies/kits & reagents in Consultation with the department.
Gaurantee period will be three years and firm is bound to provide the services (CMC) for next seven years on hospital terms & condictions.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .