| Sl No | Description | Qty | Unit | v k builder L2 | M/S SHIVA TRADERS L1 |
|---|---|---|---|---|---|
| 1.00 | M&L for installation of false ceiling using Square edge Glass fibre core fully encapsulated ceiling tile of size 595x595x15mm having volume density 100~110Kgs/m3, weight 1.8kg/m2 and 0.3mm thick suspended metal grid system complete all as per manufacturer's instructions and all as specified and directed.
Make : ANUTONE (Tiles-Subtex Ebony & grid system-Skelet Trelis T15) or equivalent of Armstrong Ceiling Solutions / Saint-Gobain Gyproc
Note : False ceiling must comply the following technical Parameters:-
a) Fire (Class) - 1 & P b) Acoustics – NRC 0.9, c) Thermal conductivity (W/mk)– 0.066
d) Climate (°C, RH) – 40, 95 e) Light reflectance (%) – low f) Green (VoC, RC %) – Low, 35 | 158 | Sqm | 2,000 ₹3,16,000 Lowest | 2,900 ₹4,58,200 |
| 2.00 | M&L for installation of false ceiling using perforated GFR gypsum panel, backlined with acoustical fleece, having 3x3mm square perforations @ 8.33mm pitch in H1 pattern, size 1200x2400x12.5mm tapered long edges, volume density of base board 700 Kgs/m3, weight 9Kgs/m2 installed by using suspended metal grid system (Strut framework system) complete all as per manufacturer's instructions and all as specified and directed.
Make : ANUTONE (Tiles-Pixel 0308 H18 & grid system-Strut framework system) or equivalent of Armstrong Ceiling Solutions / Saint-Gobain Gyproc
Note : False ceiling must comply the following technical Parameters:-
a) Fire (Class) - 1 & P b) Acoustics – NRC 0.8, c) Climate (°C, RH) – 50, 70
d) Light reflectance (%) – Paint dependent e) Green (VoC, RC %) – Low, 25 | 735 | Sqm | 5,000 ₹36,75,000 | 2,900 ₹21,31,500 Lowest |
| 3.00 | M&L for installation of wall panelling/ lining using Slats, made of pinewood E1 grade fibe rboard, melamine finish, groove perforated slats L24-2 - (2mm grooves @24mm pitch with 4.9% open area) , backlined with Sound texblack acoustical fleece of 0.27mm thick, surface density 63g/m2,tongue-groove edge for a seamless look, 5-test fire retardant grade, size 192x2440x16mm, volume density of base board 700Kg/m3, weight of base board 11.2Kg/m2 installed by using Strut framework system complete all as per manufacturer's instructions and all as specified and directed.
Make : ANUTONE (slate-Salon Series – Slats Surco Plus & grid system-Strut framework system) or equivalent of Armstrong Ceiling Solutions / Saint-Gobain Gyproc
Note : False ceiling must comply the following technical Parameters:-
a) Fire (Class) - A b) Acoustics – NRC 0.8, d) Climate (°C, RH) – 50, 70
e) Light reflectance (%) – 75 (Maple Arce) f) Green (VoC, RC %) – E1, 25 | 300 | Sqm | 8,500 ₹25,50,000 | 7,000 ₹21,00,000 Lowest |
| 4.00 | M&L for installation of wall panelling/ lining using Slim, poly fibre panels, core-pigmented, high-density, Synth PF rigid panels of size 1200x2400x9mm, volume density 200-210kg/m3, weight 1.8kg/m2 adhered on backer board, square edge magnetite bonded 2mm wide pinewood fibre core tiles of size 600x1200x10mm, volume density 400kgs/m3, weight 4kg/m2 and Strut framework system complete all as per manufacturer's instructions and all as specified and directed.
Make : ANUTONE (panels-Synth PF & grid system-Strut framework system) or equivalent of Armstrong Ceiling Solutions / Saint-Gobain Gyproc
Note : False ceiling must comply the following technical Parameters:-
a) Fire (Class) - A b) Acoustics – NRC 0.9, c) Thermal (W/mk)– 0.04
d) Climate (°C, RH) – 50, 99 e) Light reflectance (%) – Colour Dependant
f) Green (VoC, RC %) – Nil, 60 | 350 | Sqm | 8,000 ₹28,00,000 | 4,600 ₹16,10,000 Lowest |
| 5.00 | Demolition of brick work or stone/ boulder masonry work built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed. | 35 | Cum | 100 ₹3,500 Lowest | 100 ₹3,500 Lowest |
| 6.00 | M&L for Brickwork with old size sub class 'B' fly ash bricks, straight or curved on plan exc 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed. | 34.7 | Cum | 6,500 ₹2,25,550 | 5,000 ₹1,73,500 Lowest |
| 7.00 | M&L for Brick work with old size sub class 'B' fly ash bricks , straight or curved on plan in half brick thick wall built in Cement mortar 1:4 complete all as specified and directed. | 25 | Sqm | 1,000 ₹25,000 | 900 ₹22,500 Lowest |
| 8.00 | M&L for applying 1mm average water proof cement based putty @1kg (undiluted) per sqm on plastered /old prepared surface of wall using fully automatic airless spray machine and sanding when dry with 240 grit sand pad using mechanical wall sander to make the surface even, smooth, clean, free from dust and ready to receive finishing primer/paint coat complete all as specified and directed.
Note : (i) Putty powder shall be mixed with water as per manufacturer's recommendation/instruction using mechanical putty mixer having mixing capacity of min 2.5 kg putty per minute and allow 6-8 hrs time to dry the putty surface.
(ii) Fully automatic airless spray machine shall have 1 litre per minute minimum flow speed and 3300PSI pressure
Make : Birla white / JK putty/ Burger | 2,040 | Sqm | 100 ₹2,04,000 Lowest | 100 ₹2,04,000 Lowest |
| 9.00 | M&L for one coat of acrylic water based interior grade primer @ 0.9litre(undiluted)/ 10 sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine and allow 6-8 hours to dry the surface before painting of subsequent coats complete all as specified and directed.
Make : Asian(Apex Altima)/ Burger(weather coat all Guard)/ Nerolac(Excel total)
Note : (i) The emulsion used shall be of approved colour by GE diluted as per manufacturer's instructions | 670 | Sqm | 150 ₹1,00,500 | 25 ₹16,750 Lowest |
| 10.00 | M&L for applying two coats of water based premium acrylic smooth interior emulsion of approved colour over primed surface with fully automatic airless spray machine complete all as specified and directed.
Make : Asian(Apex Altima)/ Burger(weather coat all Guard)/ Nerolac(Excel total)
Note : (i) The emulsion used shall be of approved colour by GE diluted as per manufacturer's instructions
(ii) Fully automatic airless spray machine shall have 1 litre per minute minimum flow speed and 3300PSI pressure
(iii) The emulsion shall have silicon additive excellent dirt pickup resistance with low VOC ( less than 50), Antifungal/ Anti Algai properties.
(ii) Emulsion not less than 1.79 litre(undiluted)/10 Sqm in two coats shall be used. It can be diluted as per manufacture's instructions | 670 | Sqm | 150 ₹1,00,500 | 45 ₹30,150 Lowest |
Tender Value
₹1.8 Cr
EMD Value
₹2.5 L
Closing Date
26 Jun 2026, 6:00 pmClosed
GARRISON ENGINEER SAUGOR
GARRISON ENGINEER SAUGOR Military Engineer services Garrison Engineer Saugor MP- 470001
SPL REPAIR TO BLDG NO ES-16 UNDER AGE B/R-I OF GE SAUGOR
2026_MES_768100_1
GE/SGR/TOK-35 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
Saugor
Class B category a (i) and as per tender documents
7 documents required · 7 mandatory
₹1,000
GARRISON ENGINEER SAGAR
₹2.5 L
Yes
8 Sept 2026
27 May 2026
29 Jun 2026
27 May 2026
26 Jun 2026
18 Jun 2026
27 May 2026 - 3 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for installation of false ceiling using Square edge Glass fibre core fully encapsulated ceiling tile of size 595x595x15mm having volume density 100~110Kgs/m3, weight 1.8kg/m2 and 0.3mm thick suspended metal grid system complete all as per manufacturer's instructions and all as specified and directed.
Make : ANUTONE (Tiles-Subtex Ebony & grid system-Skelet Trelis T15) or equivalent of Armstrong Ceiling Solutions / Saint-Gobain Gyproc
Note : False ceiling must comply the following technical Parameters:-
a) Fire (Class) - 1 & P b) Acoustics – NRC 0.9, c) Thermal conductivity (W/mk)– 0.066
d) Climate (°C, RH) – 40, 95 e) Light reflectance (%) – low f) Green (VoC, RC %) – Low, 35 | 158 | Sqm | - | - |
| 2 | M&L for installation of false ceiling using perforated GFR gypsum panel, backlined with acoustical fleece, having 3x3mm square perforations @ 8.33mm pitch in H1 pattern, size 1200x2400x12.5mm tapered long edges, volume density of base board 700 Kgs/m3, weight 9Kgs/m2 installed by using suspended metal grid system (Strut framework system) complete all as per manufacturer's instructions and all as specified and directed.
Make : ANUTONE (Tiles-Pixel 0308 H18 & grid system-Strut framework system) or equivalent of Armstrong Ceiling Solutions / Saint-Gobain Gyproc
Note : False ceiling must comply the following technical Parameters:-
a) Fire (Class) - 1 & P b) Acoustics – NRC 0.8, c) Climate (°C, RH) – 50, 70
d) Light reflectance (%) – Paint dependent e) Green (VoC, RC %) – Low, 25 | 735 | Sqm | - | - |
| 3 | M&L for installation of wall panelling/ lining using Slats, made of pinewood E1 grade fibe rboard, melamine finish, groove perforated slats L24-2 - (2mm grooves @24mm pitch with 4.9% open area) , backlined with Sound texblack acoustical fleece of 0.27mm thick, surface density 63g/m2,tongue-groove edge for a seamless look, 5-test fire retardant grade, size 192x2440x16mm, volume density of base board 700Kg/m3, weight of base board 11.2Kg/m2 installed by using Strut framework system complete all as per manufacturer's instructions and all as specified and directed.
Make : ANUTONE (slate-Salon Series – Slats Surco Plus & grid system-Strut framework system) or equivalent of Armstrong Ceiling Solutions / Saint-Gobain Gyproc
Note : False ceiling must comply the following technical Parameters:-
a) Fire (Class) - A b) Acoustics – NRC 0.8, d) Climate (°C, RH) – 50, 70
e) Light reflectance (%) – 75 (Maple Arce) f) Green (VoC, RC %) – E1, 25 | 300 | Sqm | - | - |
| 4 | M&L for installation of wall panelling/ lining using Slim, poly fibre panels, core-pigmented, high-density, Synth PF rigid panels of size 1200x2400x9mm, volume density 200-210kg/m3, weight 1.8kg/m2 adhered on backer board, square edge magnetite bonded 2mm wide pinewood fibre core tiles of size 600x1200x10mm, volume density 400kgs/m3, weight 4kg/m2 and Strut framework system complete all as per manufacturer's instructions and all as specified and directed.
Make : ANUTONE (panels-Synth PF & grid system-Strut framework system) or equivalent of Armstrong Ceiling Solutions / Saint-Gobain Gyproc
Note : False ceiling must comply the following technical Parameters:-
a) Fire (Class) - A b) Acoustics – NRC 0.9, c) Thermal (W/mk)– 0.04
d) Climate (°C, RH) – 50, 99 e) Light reflectance (%) – Colour Dependant
f) Green (VoC, RC %) – Nil, 60 | 350 | Sqm | - | - |
| 5 | Demolition of brick work or stone/ boulder masonry work built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed. | 35 | Cum | - | - |
| 6 | M&L for Brickwork with old size sub class 'B' fly ash bricks, straight or curved on plan exc 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed. | 34.7 | Cum | - | - |
| 7 | M&L for Brick work with old size sub class 'B' fly ash bricks , straight or curved on plan in half brick thick wall built in Cement mortar 1:4 complete all as specified and directed. | 25 | Sqm | - | - |
| 8 | M&L for applying 1mm average water proof cement based putty @1kg (undiluted) per sqm on plastered /old prepared surface of wall using fully automatic airless spray machine and sanding when dry with 240 grit sand pad using mechanical wall sander to make the surface even, smooth, clean, free from dust and ready to receive finishing primer/paint coat complete all as specified and directed.
Note : (i) Putty powder shall be mixed with water as per manufacturer's recommendation/instruction using mechanical putty mixer having mixing capacity of min 2.5 kg putty per minute and allow 6-8 hrs time to dry the putty surface.
(ii) Fully automatic airless spray machine shall have 1 litre per minute minimum flow speed and 3300PSI pressure
Make : Birla white / JK putty/ Burger | 2,040 | Sqm | - | - |
| 9 | M&L for one coat of acrylic water based interior grade primer @ 0.9litre(undiluted)/ 10 sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine and allow 6-8 hours to dry the surface before painting of subsequent coats complete all as specified and directed.
Make : Asian(Apex Altima)/ Burger(weather coat all Guard)/ Nerolac(Excel total)
Note : (i) The emulsion used shall be of approved colour by GE diluted as per manufacturer's instructions | 670 | Sqm | - | - |
| 10 | x}M&L for applying two coats of wat | 670 | Sqm | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_860174.xls
BOQ • 0.47 MB
PSTOK35.pdf
Additional Documents • 0.97 MB
GPTOK35.pdf
Tender Documents • 0.90 MB
DateCorrg2TOK35.pdf
PDF • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .