Loading…
Loading…
Tender Value
₹11.7 Cr
EMD Value
₹7.4 L
Closing Date
25 Jul 2025, 11:00 amClosed
SWR: Hubballi Division: Bannihatti (BNHT): 02 additional Loop lines with 02 Shunting necks.
13UBL2025-26-01
13UBL2025-26-01
Open
6 Months
Dharwad, Karnataka
₹0
₹7.4 L
27 Jun 2025
27 Jun 2025
01-Signal Schedule-A
02-Signal Schedule-B
03-Signal Schedule-B1
04-Signal Schedule-C
05-Signal Schedule-D
06-Telecom Schedule-A
07-Telecom Schedule-B
08-Telecom Schedule-B1
Item Breakup - 01-Signal Schedule-A
Supply of Double walled corrugated pipe Metre 103.5mm inner dia & 120mm outer dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as per Technical specification ( Inspection Consignee )
Supply of GI pipes - 100 dia 4.5mm thick as Metre specified ( Inspection Consignee )
Supply of HDPE duct 40/33 (OD/ID) dia in Kilometre 500/1000 mtrs along with End Cap, End Plug, Cable Sealing Plug and Couplers, as per RDSO/SPN/ TC/45/2013 Rev.2 (upto Amdt.2) or latest ( Inspection Consignee )
Supply of surface base to suit CLS signal Numbers pole 140mm dia with necessary inspection as per specification / drawing/ description enclosed in this document( Inspection Rites )
Supply of FRP 4 aspect colorlight unit Numbers assembly as per RDSO Spec.No. RDSO/SPN/ 194/2006 Rev .2.0 or latest (Terminal box,mounting socket, hood, side flangeand fixing bolt & nut, eye bolt, M12bolt-3 Nos. and Fixing bolt 12 Nos ( Inspection Rites )
Supply of FRP CLS Signal Units 3 Aspect Numbers unit without leness, lamps and transformer as per RDSO Specification. No. RDSO/SPN/194/2006 Rev 2.0 or latest. Accepted Make: Akshay ( Warranty Period : Upto 30 months from the date of supply) ( Inspection Rites ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of FRP CLS unit 2 Aspects without Numbers lenses, lamps or transformers as per RDSO Specification No.RDSO/SPN/194/2006 Rev.2.0 or latest Accepted Make: Akshay (Warranty Period : Upto 30 months from the date of supply ( Inspection Rites )
Supply of Calling On Signal- complete as Numbers per specification/ drawing enclosed.( Inspection Rites )
Supply of Ground type shunt signal Numbers complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document.( Inspection Rites )
Supply of post type shunt signal-complete Numbers with hood etc., with necessary inspection a s per specification/ drawing/ description enclosed in this document.( Inspection Rites )
Supply of Colour light Signal pole 140mm Numbers dia, 4.6m/ 3.6m tall with necessary inspection as per specification/ drawing/ description enclosed in this document. (Supply of colour light Signal pole 4.6m tall and 140 mm dia) ( Inspection Rites )
Supply of Colour light Signal pole 140mm Numbers dia, 4.6m/ 3.6m tall with necessary inspection as per specification/ drawing/ description enclosed in this document. (Supply of colour light Signal pole 3.6m tall and 140 mm dia) ( Inspection Rites )
Supply of ladder with platform and shoes Numbers t o suit CLS pole 4.6m/ 3.6m tall, with necessary inspection as per specification/ drawing/ description enclosed in this document. Supply of ladder with platform (4.6m) for CLS) ( Inspection Rites )
Supply of ladder with platform and shoes Numbers t o suit CLS pole 4.6m/ 3.6m tall, with necessary inspection as per specification/ drawing/ description enclosed in this document. Supply of ladder with platform (3.6m) for CLS ( Inspection Rites )
Supply of Off-set brackets-large/ small Numbers made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. (Supply of Off set bracket-large) ( Inspection Rites )
Supply of off set bracket large/ small made Numbers of cast iron with necessary inspection as per specification / drawing / description enclosed in this document a) Supply of off set bracket Small ( Inspection Rites )
Supply of Vitreous enamel coating boards Numbers consists of signal Number plates of size 280 x 102 x 2 mm or latest dimensions . (Note :white background with lettering in black) with half round clamp to suit signal post and horizontal flat for support made out of MS flat of size 40 mm x 3 mm thick and with suitable nut, bolts and washers. The signal number plates data particulars to be collected from consignee before supply. Firms accepted offer Make/Model: ME, Firm should supply the, 01(one) no sample to be approved before bulk supply ( Inspection Consignee ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of Main LED Signal Aspect-Red as Numbers per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest ( Inspection RDSO)
Supply of Main LED Signal Aspect-Yellow as Numbers per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest ( Inspection RDSO)
Supply of Main LED Signal Aspect-Green as Numbers per RDSO Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest ( Inspection RDSO)
Supply of multi lamp route indicator (LED Numbers double digit) from 1 to 19 white LED with housing as specification enclosed.( Inspection RDSO)
Supply of SubsidarySignal Aspect-Calling Numbers on LED as per RDSO Specifications RDSO/SPN/153/2011 Rev4.1 or latest ( Inspection RDSO)
Supply of SubsidarySignal Aspect-Shunt Numbers LED as per RDSO Specification RDSO/SPN/153/2010 Rev1.1 or latest ( Inspection RDSO)
Supply of High Avalibility Single Section Set Digital Axle Counter (HA-SSDAC) with Dual Track sensor Devices as per RDSO specification No. RDSO/ SPN/ 177/ 2012 version 3.0 or latest ( Phase reversal type) as per details given below a) Configuration 2DP-1 section b) length of cable required with each track devices - 15 mtrs ( Inspection RDSO)
Supply of V.F. and Signaling Transformers Set as per RDSO spec No. IRS-TC-22/76 or latest ( Inspection Rites )
Supply of Relay, Non-AC Immune, plug-in Numbers type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34 & IRS:S 23or latest. The interlocking code for this unit shall be ABDEF. ( Inspection RDSO)
Supply of Relay, AC Immune, plug-in-type, Numbers Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23or latest. The interlocking code for this unit shall be ABDGH. ( Inspection RDSO)
Supply of lamp proving relays for LED Numbers aspects with plug boards, connectors and retaining clips with necessary inspection as per specification.( Inspection RDSO)
Supply of Relay, AC immune plug-in-type, Numbers style "QBA1" DC biased line, 24V, 8F/8B contacts, front and back contacts metal to carbon complete with plug board, retaining clip and connectors conforming to BRS:932A, IRS:S - 60, IRS:S-34 AND IRS:S- 23 or latest. The interlocking code for this unit shall be ACDEH.( Inspection RDSO) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of KLCR relays 24V, ACI (Supply of Numbers Key Lock Checking Relay (KLCR) with one number K-50neutral Relay toworkon 24V DC non AC immunizedas per specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt 1 or latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S 34 IRS:46or latest. ( Inspection RDSO)
Supply of Terminal Block: 6 way Poly Numbers butylene Terephthalate (PBT) of size 25mm (link centre to centre) as per RDSO ORG. No. SA23756/Alt.3 or latest, S23757tAlt.4 or latest and specifications IRS: S 75-2006 Rev. 2.0 (Tentative) or latest, IRS: 5 23-88 Amd. 1 or latest. ( Inspection RDSO)
Supply of Terminal Block 1 way Poly Numbers butylene Terephthalate (PBT) of size 60mm (link centre to centre) as per RDSO DRG. No.SA23745/Alt.5 or latest, SA23746/Alt.5 or latest, S23747/Alt.5 and specifications IRS: S 75-2006 Rev. 2.0 (Tentative) or latest, IRS: S 23-88 Amd. 1 or latest. ( Inspection RITES)
Tool Kit for High Availability Single Section Set Digital Axle Counter as per Specification No. RDSO/SPN/177/2012 (Version - 3) or latest, consisting of :- (i) Portable Data Analyser (Downloading Event Logger Data for analysis and report generation) - 1 No. (ii) Pure Sine Wave Digital Multi-meter Fluke Make (Model-1871) or Rishab Make (Model-28S) - 1 No. (iii) Extender Card - 1 No.(iv) Dummy Wheel - 1 No. (v) Ring Spanner (17-19, 24-26) - 1 No. each (vi) Open End Spanner (17-19, 24-26) - 1 No. each (vii) Socket Spanner with Handle - 1 No. (viii) Torque Wrench (Jaicom JPR or equivalent 88 NM_ - 1 No. (ix) Screw Driver No. 902 or as directed by Engineer-in- Charge - 1 No. (x) Screw Driver No. 935 or as directed by Engineer-in -Charge - 1 No. (xi) Marking Jig for Drilling - 1 No. (xii) Dummy Load to check Power Supply (Resistive) - 1 No. and any other additional specialized Tools suggested by RDSO Approved OEM required for Trouble Shooting and Maintenance of Equipment ( Inspection Consignee )
Supply of apparatus cases (full/ half/ Numbers quarte r size) to suit Southern Railway standard with necessary inspection as per s p e c i fi c a t i o n / drawing/ description enclosed in this document (Supply of apparatus case-Full size) ( Inspection RITES)
Supply of apparatus cases (full/ half/ Numbers quarte r size) to suit Southern Railway standard with necessary inspection as per s p e c i fi c a t i o n / drawing/ description enclosed in this document ( Supply of apparatus case-Half size)( Inspection Rites )
Supply of E-Type Locks ( Inspection Rites ) Numbers HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of Universal Locks with one steel Numbers key for every ten locksorpartthereof(Forexample, if locks ordered is 10,1 key is to be supplied and if locks ordered is 20, 2 keys to be supplied. However, 2 keys to be supplied if locks ordered is between 11 and 19)
Supply of magneto telephone handle type Numbers and supply and wiring of Ni-cad power pack 4V-2.2AH with charger to work on 110VAC, at the station house, LC Gate and top points. [Magneto telephone handle type with Ni-cad power pack 4V-2.2AH with charger to work on 110VAC, wire PVC 16/0.2mm copper, and all other miscellaneous materials shall be supplied by the Contractor.] ( Inspection Rites )
Supply of wago terminal of 2 conductor Numbers disconnecting terminal block for 2.5 sqmm wire termination make: wago/elmex or similar with accessories & taxes. ( Inspection Rites )
Supply of powder coated Relay rack Numbers universal type as per DRG. No. S&T/MFT/291. The relay rack shall be supplied with caffolding, stainless steel nuts and bolts for fixing the rack, supporting angles, frame mounting triangle base with J' bolts, insulation of required numbers and suitable inner frames to suit Q style relays I K50 pre wired tag blocks. ( Inspection Consignee )
Supply of powder coated Cable termination Numbers rack of size 880mm x 2075mm made using 50mm x 50mm x 6mm (6mm thickness) MS angles. The cable termination rack shall be supplied with stainless steel nuts and bolts for fixing the rack, tripod bases and reel insulators (for K rack, P rack and power rack), cable ladder of 400mm width and 2075mm length with two angles of size 40mm x 40mm x 5mm (5mm thickness) and supporting flats of size 25mm x 25mm. Suitable holes shall be drilled to fit hylam sheet as per standard practice ( Inspection Consignee )
Supply of 2 pin socket - 5A with switch, Numbers fixing the same on the hardwood plank available and extending the 110VAC using wire PVC 3/0.75mm copper, in all the apparatus cases, as per the instructions of Railway representative at site. [2 pin socket - 5A with switch, wire PVC 3/0.75mm copper and all other miscellaneous materials required for the work shall be supplied by the Contractor]. ( Inspection Consignee )
Supply of PVC insulated Wire Coils Multi- Numbers strand, single core, copper conductor 16/0.2 (16 wires, diameter of each wire is 0.20mm) (0.55q.mm) wire coil as per specifications IS 694:2010 or latest, IRS: S 76-89 Amd. 3 or latest. Length of coil should be lOOm. Colour of coil to be specified by Engineer in charge ( Unit;Coil=Nos) ( Inspection Consignee ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of PVC insulated Wire Coils Multi- Numbers strand, single core, copper conductor 28/0.3 (28 wires, diameter of each wire 0.30mm) flexible wire coil as per specifications IS 694:2010 or latest, IRS: S 76-89 Amd. 3 or latest. Length of coil should be lOOm. Colour to be specified by Engineer in charge. ( Inspection Consignee )
Supply of 10 Sq.mm PVC insulated, multi- Metre strand, single core, copper conductor 140/0.3 (140 wires, diameter of conductor 0.3mm) cable as per IS: 694 or latest, IRS: S 76-89 Amd. 3 or latest. Cable to be supplied in 100 meter coil. ( Inspection Consignee )
Supply of non-deteriorating type of fuse Numbers holders and fuse links 240V AC/DC as per specification IRS: S 78-2006 or latest, IS 13703 (Part 2):1993 knife edge type fuse of El fuse link type (up to 20A) ( Inspection Consignee )
Fuse link IA I 2A I 6A I I0A I I6A / 20A as Numbers specified by Engineer In charge. ( Inspection Consignee )
Supply of Basic material to construct a Set Maintenance Free Ring Earth with Four Pits (For Interlocked Station, LC Gates/IB Signalling Application) for achieving less than one Ohm as per as per RDSO Spec No. RDSO/ SPN/ 197/2008 or latest and as per relevant Technical specification ( Inspection RDSO )
Supply of Basic material to construct unit Set maintenance free earth consisting as per RDSO SPN/197/2008 or latest ( Inspection RDSO )
Supply, Commsissioning of Copper Plate Earthing System complete as per Drg.No.SG/SWR/058 with provision of (i) Copper plate 300l ifn X 300mm X 3 mm, (ii) Earth Pit 6 ft depth filled up with charcoal 10 kg & salt 25 kg in alternate layers up to 2 ft from bottom, (iii) Water funnel on Perforated GI pipe of length 4.5 ft., (iv) Cast Iron top plate 12 x 12 (v) Drawing of copper - earth from earth to location with 25 mm x 3 mm copper strip for termination (All miscellenous materials to be supplied by the contractor) ( Inspection Consignee )
Supply of Earth Leakage detector 12 Numbers channel (4 Channels110V AC, 2 Channels- 110V DC, 6 Channels- 24V DC) as per RDSO Spec./256/ 2002 or latest with 6 digit counter.( Inspection RDSO)
Supply of Steel Almirah (Model : Godrej Numbers Store well/slimline 4S ) ( Inspection Consignee )
Supply of UL standard PPTC fuses complies Set to UL Themistor standard 1434 with rating -2 Amps, make LITTLE FUSE, FUZETEC, TYCO, BOURN, RAYCHEM or Better.( Inspection Consignee )
Supply of chair RK Empire (RK-CMMST)( Numbers Inspection Consignee ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply office table (Occice table 017 CBL Numbers office furnitures ( CBL8027)( Inspection Consignee )
Supply of Electrical Point Machine, Non- Numbers trailable type, Conforming to RDSO Spec. No. IRS.S.24/2002,amendment no.1 or latest with the following parts:- (a) 220mm Throw with interlocking for Operation of The point as per RDSO Drg. no. S-3395A (b) Switch extension Bracket (P-Bracket) and insulation Plates as per RDSO drg.no.S3591, 3592 & 3593 (c) Detector rods (Long & Short) as per RDSO drg. no.S- 3594-95, Lock rods (Long & Short) as per RDSO drg. no.S-3597-97 (d) Drop lug as per RDSO drg. no. S-3598 including all insulations and accessories. Electric Point Operating Machine-IRS Type 220mm Throw ,High thrust (AC immunity 160V AC) non -trailable to operate on 110 V DC complete with lock & Detector slides, Cable terminal Box and Clamp Lock & Ground Connections. Confirming to IRS:S24/2002 & Assy. Drg. No.- RDSO-S/11000 & for motor IRS:S37/82 ( Inspection RDSO)
Supply of coding / decoding programable Numbers system as per specification HP DA 326TU. Intel Core i3-7100U 7th Gen processor, 2.4 Ghz base processor speed, 2 Cores, 3MB cache, 4GB RAM, 1TB hard disk, DVD writer, 15.6 FHD screen, Wi-Fi, Bluetooth card reader, web cam, Windows 10 Home or latest. Accepted make - HP, DELL or Lenovo ( Inspection Consignee )
Supply of 2C X 1.5Sq.mm copper armoured Metre FRLS cable with proper clamping, supports & terminations. Make: Make: Varsha/ Polycab/ Havells or better ( Inspection RDSO)
Supply of Electric key transmitter (Rotary Numbers type) RDSO Drg No. SA 22601 (Adv) Alt-4 and specification No. IRS S-21/2001( Inspection RDSO)
Supply of crank handle box / Emergency Numbers key box made of teak wood with glass fronted door as per drawing 03/91 with decolum sheet on all exposed surface and for with RKT inside the box with L&T micro push switch with 2NO+2NC contacts and veeder counter non-reset type ( Inspection Consignee )
Supply of FRP road warning equipment ( Set Inspection Rites )
Supply of Emergency Inspection Rites )
Supply of LC Gate panel ( Inspection Rites ) Numbers
Supply of Online UPS of 1 KVA capacity Numbers input voltage 160V AC - 280 V AC, output voltage 230V AC, Operating Freq 47-63 Hz with back up time 30 min (APC or Emerson) ( Inspection RDSO)
supply of AC/DC Digital Clamp meter Numbers Current measurement upto 200A AC/DC True RMS measurement for AC voltage & current.(Large jaw opsize of 18mm ) Model: FLUKE 362/Rishabh or higher specification. ( Inspection Consignee ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply and installation of De-ioniser plant Numbers (Aqua-ion model No. ACAMB 4 Bed type)( Inspection Rites ) Total 19186947.13
Item Breakup - 02-Signal Schedule-B
Independent Checking & verification of Station Interface Circuits for Stations having upto 25 Routes, by IRSE/ IRSTELO License Holders.
Independent Checking & verification of Station Application Logic Circuits for Stations having upto 25 Routes, by IRSE/ IRSTELO License Holders.
Additional Payment for checking and Per Unit verification of Interface Circuits/ Logic Circuits having more than 25 routes, by IRSE/ IRSTELO License Holders. Note: In case of alteration in approved SIP or TOC, payment shall be applicable per route basis as per item No.11 & 12. (Per UNIT= Per Route / Per Station)
Fabrication , Supply & lnstallation of Dual Set VDU Control Table - 1 No. and table for block instruments - 2 Nos. per set. as per approved Drawing No.RVNL/S&TlSCl14lN2018. lt includes transportation of materials to station. lt shall be comprising of the following materials:- 1) Teak wood top of 1 inch thickness (finished size) with Teak wood beading around the table with polishing and neat finishing. 2) Stainless Steel Allen Head screws,Nuts, Bolts and washers whereever required. Necessary allen keys of suitable sizes will be provided as spares. 3)Tower bolt arrangement for all front doors. 4) 01 universal lock, 1 Cam lock with universal key and sealing arrangements for all back doors. 5) Plastic Flush door handle for all doors. 6) M.S Sheet of 1.2 mm thickness to be used for all doors and shelves. 7) Vertical/ Horizontal slotted angles / slotted DIN rail of suitable size to be provided. 8) Cable troughs of suitable size with fixing arrangements. 9) Legs and vertical structure of 40 Sq MS Pipe. 10) Horizontalsupports of 20"40 M.S Pipe. 11) Structure for holding VDU with clamping provision 12) Earthing provision with symbol. 13) Powder coating of complete M.S frame , doors, and slotted angles to required color. 14) Provision of arrangements for DC fans for heat exhaust 15) Acyrilic Railing with Stainless Steel supports. 16) 01 Shelf arrangement for Block Bell equipment etc., 17) Provision for flxing of lsolation Transformer on either side for Block counter table. 18) Matching hole arrangements to be provided as per Drawing for cable. (Inspection Consigne) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Modular Power supply Arrangement for Set VDU (42"-85") and Industrial PC (Embedded PC) with input and output redundancy arrangement and hot pluggable modules in set. One set Consists of :- 1. Input O-Ring diode Module with potential free-1 no contacts ( PFC) for two 110V DC sources from IPS and Single 110V DC Bus. Quantity : 1 No. 2.Isolated Inverters (Master/Slave), Input 110 V DC, Output : 110/120 V AC 500 VA Quantity : 2 Nos. 3.Isolated DC-DC Converters, Input 110V DC, Out Put 24V DC/10A , Quantity : 2 nos. 4.3U SS Rack with back Panel mother Board/front panel power connectors inverter auto changer over switch and all required over switch and all required protection circuits ( 3U height for main rack 132.5mm +/- 10% & 1U height for mounting 44.5mm +/-10%) Quantity; 1 No. ( Total 4 items ) Make: Gallant or Similar. (Inspection Consigne)
Supply and Placing of Trunking and Numbers Capping (RCC Duct) of 500mm Width as per Drg. No. SDO/Cable laying/ 007 (Annexure-10), as detailed in document No. RDSO/SI/G/2010 Ver.1.1 or latest on 'Guidelines on signalling cable laying' (1Nos=700mm)
Supply and laying of Split DWC pipe of Per Unit 120/103 mm dia, 2 meter long in already dug cable trenches. The unit of RMT means two split pipes of 1 Mtr each. Material shall be supplied as per specification RDSO/SPN/204/2011 or latest" {Per Unit- RMT}. (Inspection Consigne)
Supply and Laying of PVC Warning Tape Kilometre colour Orange, width of 250mm (10") by printing with black letters 'Indian Railway Signal/Telecom/OFC Cable' on both sides. (Inspection Consigne)
Video recording of cable trench using Kilometre minimum720P and above HD camera and submit one copy in New removable hard discs (With capacity as per requirement); Two copies in DVD-R
Supply, transporting and installation of Set Concrete (RCC) Route Indicators at intervals of 50 meters as per instructions of engineer in charge as per drawing no. SK 12/10.They should be of standard RCC with letters "SCR S&T cable" as per type of cable laid to drawing. In case of telecom quad cable joint locations it shall be painted with GREEN and ORANGE colour for normal indication of cable path. (Inspection Consigne)
Excavation of pit, casting concrete Numbers foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation bolts, cement, river sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Erection of surface base, signal pole, Set mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of speed limit board wherever necessary, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. (Supply of surface base, Offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule). ['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor].
Excavation of pit and casting concrete Numbers foundation as per Drg, No.SG/CN/02/10 using metallic templates, for erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor].
Erection of Ground type shunt signal Numbers complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. (Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this schedule). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Fixing Multi lamp/ Stencil type route Numbers indicators-complete, termination of tail cables, wiring as per approved circuit diagram using wire PVC 3/0.75mm & 16/0.2mm copper, provision of EWS required Nos., and painting (Supply of route indicators is notcovered in this schedule) [Fixing bolts and nuts, EWS locks wires PVC 3/0.75mm & 16/0.2mm copper, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. Fixing and wiring of Multi lamp route indicator
Fixing of Offset brackets using 'U' bolts and Numbers nuts, erection of Post type shunt Signals, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock and painting of one coat of red oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down.
Supply and fixing of retro-reflective type Numbers Goods Warning Boards as per practice & SEM(Angle/Rail is to be supplied by Railway). (Inspection Consigne)
Supply and fixing of retro-reflective type Numbers Calling- ON/STOP/BSLB/Legend boards as per practice & SEM (Angle/Rail is to be supplied by Railway). (Inspection Consigne)
Dismantling and releasing of existing Numbers C o l o u r light Signals complete (upto 4 aspects) with o r without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The w ork includes breaking the concrete foundation,
Supply, transportation, installation, testing Numbers and commissioning of MSDAC for mentioned DP as per SIP of the purpose of TCs, complete system including central evaluators, processors, final track clearence relays for each track section, reset boxes, monitoring consoles. Diagnostic PC/laptop for suitable configuration LV boxes, detection points, mushroom housing for track sid electronic, deflector plates and all other accessories for sucessfull commissioning as per RDSO specification No RDSO/SPN/176/2013 (ver.3) or latest specification of OEM/ manufacture and as per TS given in Annexure-A (Inspection RDSO) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply and Installation of Rack mountable Numbers 48 Fibre management system (FMS) conforming to RDSO/SPN/TC3712000(rev- 3) amdt-1 or latest similar to COMSCOPE make or better, suitable forsplicing and front patching 48F cable with all accessoriesand terminating the optical fibre cable with splicing and front patching in FMS in the equipment room. (OFC Pigtail patch chords of suitable length and all other materials required for splicing are to be supplied by contractor). (Inspection RDSO)
Supply and Installation of Pre-wired Crank Set Handle Cum Key Lock Relay Box (of MS Sheet) along with LEDs, with approved type push buttons, Wago or similar Disconnecting type Terminal Blocks inlcuding DIN rail etc., as per tentative drawing enclosed. Installation, fixing and wiring of boxes for Key Lock Relays to be carried with Contractor's wiring and fixing material. The work shall be carried as per the instructions of site engineer. (Inspection RDSO)
Supply and installation of teakwood glass Numbers fronted box of size 300mm x 600mm x 75mm with hooks to keep various keys w i t h description engraved on the tags. [ T W G l a s s fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall be supplied by the Contractor]. (Inspection Consigne) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Manufacture and supply of teak wood tool Set box of size 1000X750X100mm made of 25mm thick teak wood persplex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: a. Digital Mulltimeter similar to Model No.Rish Multi 15S with suitable carrying case and test probes. b. Multimeter similar to Model No.HM 102 BZ Hungchung with test probes with suitable carrying case.- 1 No. c. Centre zero ammeter 30-0-30 Amps - 1 No. d.. Screw drivers of different types and sizes with common handle - 1 set e. Spanner double ended 33mm - 1 No. f. Spanners double ended 3/8x1/2" - 1 No. g. Spanners double ended 5/8x3/4" - 1 No. h. Spanners double ended 7/8x1" - 1 No. i. Hammer 1 1/2 lbs ball pane - 1 No. j. Hacksaw frame - 1 No. k. Adjustable screw spanner 12" - 1 No. l. Insulated cutting pliers- 1 No. m. Insulated nose plier- 1 No. n. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. o. Electric soldering iron 110V 35W Soldron/Philips make - 1 No. p. Megger 500V/ 500Mohms. with Probe - 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site. [Teak wood tool box made of 25mm teak wood plank, perspex sheet, all the tools mentioned above, padlock and other miscellaneous items shall be supplied by the Contractor]. (Inspection Consigne)
Erection lway/2way/4way with scaffolding suitably concreting tn-pod bases using J-bolts, fixing rack support of size 50 x 50 x 6 mm on to the wall. Reel insulators are to be provided for insulating the rack from the scaffolding & tn-pod bases.
Provision of 2 Machine cut grooves in Metre parallel at a separation of 8 cms each to a depth of 150 mm in the platform surfaced/tiled floor for laying cable.
Supply and Fixing of PVC casing and Metre capping/PVC pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/Reservation office /Data logger/FOIS room etc. (All required material for fixing to be arranged by the contractor) (Inspection Consigne)
Supply and fixing of Flex printed Sun Square boards of various sizes of various drawings Foot of Power diagram, Relay index chart, Station Rule Diagram, FTOT Particulars, yard layout diagram board etc with diffrents colours as per instructions of Site In-Charge/Railway Representative. (Inspection Consigne) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Printing, Binding & supply of the following Numbers Registers with latest proforma given by in- charge officer each registr of 100 pages. Station Asset Register/Deficiencies Book/Officer Inspection book/ Work site orientation classes note book/Station Message book/Infrigement measure book fog signal gears/Route cancellation register/Relay room Key register/Cable testing summary/Signal maintenance record register/Power Systems Battery maintenance Register/Mechanical Signalling Register/Axle Counter Maintenance Register/Block instrument Maintenance Register/Track circuit maintenance Register/Lifting barriers maintenance Register/Electrically operated point maintenance Register/Electronic lnterlocking Maintenance Register/Location box maintenace Register/Earth Testing record Register/Relay room register/Joint Inspection of Points and Crossings register/Block Proving Axle Counter Register/Diesel generator /SoIar panel Register. (Inspection Consigne)
Supply, commissioning of Integrated Power Supply (IPS) system SMPS based Up to 6 lines in RE area confirming to RDSO specification NO. RDSO/SPN/165/2012 VERSION 3.0 with latest amendment and configuration as enclosed Annexure-A, List of spares enclosed Annexure -B, Tools to be supplied as per Annexure -C including power supply module for axle counter (BPAC), Data Logger and with EI Module. The IPS should be suplied with 60 Nos of 200AH LMLA battery, along with 16Sqmm Cable for IPS battery 20 Mtrs, ASM Panel: 50 Mtrs and Data Logger 50 Mtrs required. The supplier shall take up installation , wiring, testing and commission with minimum one month prior notice period from Railways. 2. All the required cables/ Miscellaneous items for commissioning shall be supplied as part of this tender. 3.Supply, installation, testing and commissioning of SPDs (class B&C) are covered in scope of this tender, Supply items shall be inspected by RDSO. (Inspection RDSO)
Supply and Provision of Power Supply Numbers Change over arrangement at SM room. CLS panel of size 800x500x275mm powerd coated of MS sheet thickness 1.6mm as per RDSO specification No TI/SPC/PSI/CLC/0020 . (Inspection Consigne) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Manufacture Distribution Panel for IPS using Hylem sheet 10 mm as per site requirement and erecting it using MS angle clamp 65mm X 65mm X 8mm, HRC fuse block, Mains control switch, ammeter by-pass switch, voltmeter, ammeter, PBT terminals 60mm and wiring the same using wire PVC 7/1.40mm as per approved power diagram. This also includes termination of power cables using teakwood clamp of size 25mm X 60mm X 150mm on a base plank of 25mm thick 150mm width. (MS angles 65mm X 65mm X 8mm, Hylem sheet of 10 mm Thickness, as per site requirement, bolt and nuts required for manufacture of power panel, HRC fuses, box and carriers, teak wood clamp, wire 7/1.40mm, PVC casing and capping and all other miscellenous materials will be supplied by the contractor, Supply of PBT terminals 60mm is not included in the schedule.) (Inspection Consigne)
Transportation, Erection and wiring of IPS Numbers to power distribution panel. This includes transportation of IPS batteries from store of Dy CSTE/CN to the site, Erection of IPS panels on teakwood planks, interconnection between panels and wiring the IPS to power distribution panel using 10 sqmm multi- strand copper cable. The wiring should be done neatly using Aluminium ladder with Phynolic sheet (Aluminium ladder, Phynolic sheet of thickness 6 mm, teak wood plank of width 150 mm and thickness 25mm, 10 sqmm multi-strand copper cable and all other miscellaneous materials to be supplied by the contractor). (Inspection Consigne)
Excavation of pit, casting concrete Numbers foundations as per Drg No.SG/Proj/SK/DG/01/08 for installation of DG set as per the direction of Site In- charge Railway Representive and Carry out 1st service of the DG set as per the Manufacturer's instructions.
Supply, Commissioning, Validation & Networking of DATA LOGGER system for Rly. S&T instrument as per RDSO Spec No. IRS:S- 99/2006 (Amdt 3) with 1024 Digital and 64 Analog inputs consisting of following: A. Supply of Data logger- 01 No. B. CMU with UPS (minimum 6 hrs. battery back up)- 01 No. C. Wiring of inputs from relay contact to intermediate tag block & intermediate tag block to Data logger equipment. Note: 1. All Installation, commissioning & networking materials like wires etc. will be supplied by the firm as per specification. 2. Detail Technical requirement is as per attached document. (Inspection RDSO) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply, Commissioning, Validation & Networking of DATA LOGGER System for Rly. S&T installations as per RDSO Spec No. IRS:S- 99/2006 (Amdt.- 3) or latest with 512 Digital and 32 Analog inputs consisting of following: A. Supply of Data logger- 01 No. B. CMU with UPS (minimum 6 hrs. battery back up)- 01 No. C. Installation, Testing, Commissioning, Validation & Networking- As per requirement. D. Wiring of inputs from relay contact to intermediate tag block & intermediate tag block to Data logger equipment. Note: 1. All Installation, commissioning & networking materials like wires etc. will be supplied by the firm. 2. Detail Technical requirement is as per attached document (Inspection RDSO)
Excavation of pit, casting concrete Numbers foundation and erection of apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Refer Chapter-20, 15.1 for Drg.) (Supply of apparatus case is not included in this schedule). [Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor.]
Excavation of pit, casting concrete Numbers foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, a n d fixing of one hardwood shelf plank
case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Refer Chapter-20, 15.1 for Drg.) (Supply of apparatus case is not included i n this schedule). [Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints,varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor] HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Termination o f m a i n , t a i l , Signaling and Per Unit power cables and internal wiring on terminal/ fuse blocks in n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal b o a r d t o s u i t e a c h a p p a r a t u s case, varnishing all teakwood items, fixing of terminals/ fuse b l o c k s o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. A f t e r terminations a r e o v e r , the side openings o f apparatus c a s e foundation shall be closed w i t h brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply o f P B T terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Nondeteriorating t y p e o f f u s e s o f various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, w i r e PVC3/0.75mm c o p p e r a n d other miscellaneous materials shall b e supplied b y the Contractor]. Termination on 25/60mm PBT terminals (new location) (Phynolic sheet) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Termination o f m a i n , t a i l , Signaling and Per Unit power cables and internal wiring on terminal/ fuse blocks in n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal b o a r d t o s u i t e a c h a p p a r a t u s case, varnishing all teakwood items, fixing of terminals/ fuse b l o c k s o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. A f t e r terminations a r e o v e r , the side openings o f apparatus c a s e foundation shall be closed w i t h brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply o f P B T terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Nondeteriorating t y p e o f f u s e s o f various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, w i r e PVC3/0.75mm c o p p e r a n d other miscellaneous materials shall b e supplied b y the Contractor]. Termination on PBT fuse block (new location) (Phynolic sheet)
Manufacture a n d s u p p l y o f M . S . relay Set frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type HMU as required b y Railways and fixing them i n apparatus cases for all types of signal control circuits, L C gate control circuit a n d Point control circuits, fi x i n g o f p l u g b o a r d s , relays, resistors a n d electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination a s per approved circuit d i a g r a m a n d p a i n t i n g the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this schedule). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, p a i n t s , s o l d e r i n g m a t e r i a l s , resistors, condensers a n d a l l o t h e r miscellaneous materials required f o r t h e w o r k shall be supplied b y the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type HMU) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Wiring of Signal/ Point/ LC control circuit Set (up to 8 relays/plug in type HMU)
Wiring of Signal/ Point/ LC control circuit Set (up to 12 relays/plug in type HMU)
Filling earth around location boxes/signal cum foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming. The earth shall be taken from Railway premises as instructed by Railway representative at site.
Provision of earth electrodes as per Numbers drawing No.SG/SN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, ASM room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
Strengthening of foundations of signals, Numbers Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, carrying out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.
Supply and provision of Rubber mat of not Square less than 6mm thick and with an insulation Foot to withstand 650VAC, on the floor of relay room etc at places as indicated by railway representative at site.
Supply and installation of teakwood glass Numbers fronted box of size 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall be supplied by the Contractor]. (Inspection Consigne) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Fixing of PBT terminal block/ PBT fuse Per Block block, rubber grommets, clamping of Section cables using teakwood cable clamps and b a s e planks, termination of cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm- teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using luminium tags provided on each cable with letterspunched neatly. (Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor].Fixing of PBT terminal blocks 25mm/60mm centre) and termination ( Unit; Per Block section=Per terminal Block) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Fixing of PBT terminal block/ PBT fuse Numbers block, rubber grommets, clamping of cables using teakwood cable clamps and b a s e planks, termination of cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm- teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using luminium tags provided on each cable with letterspunched neatly. (Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. Termination using PBT fuse block in cable termination rack (Unit;-Nos=Per fuse Block)
Supply and Fixing of PVC casing and Metre capping/PVC pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/Reservation office /Data logger/FOIS room etc. (All required material for fixing to be arranged by the contractor) (Inspection Consigne)
Supply, Installation and Commissioning of Numbers Active Class 'A' Protection with Lightning Event Counter as per RDSO Spec No. SPN/197/2008 with Three Year Warranty (Make Erico, LPI or Similar). This schedule includes supply of 30 mtrs cable for connecting Air terminal & earth as specified by OEM. (as per Technical Specification enclosed) (Inspection RDSO)
Installation of Maintenance Free Ring Earth Set with Four Pits (For Interlocked Station, LC Gates/IB Signalling Application) as per RDSO specification No.RDSO/ SPN/197/ 2008 or latest and as per Technical Specification
Installation of Unit Maintenance Free Earth Set Pit as per RDSO specification No.RDSO/ SPN/197/ 2008 or latest and as per Technical Specification
Installation,Testing/ commissioning Earth Leakage Detector 12 channel . HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of design set for circuit.
Design and Drawing for complete indoor Per signalling work for new Pl/El/RRl station. PI/EI/RRI
Preparation of Station Working Rules, Per CRS/CSTE sanction papers etc as practice application in Railways for yards/LC Gate/lBH.
Design and development of outdoor Per drawings for outdoor signalling work for application new Pl/El/RRl station.
Installation of combined type point Numbers machine - IRS type and connecting all ground connections including wiring and termination in point machine and interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw bar lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways. [All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor].
Excavation of pit, erection of cable Numbers termination boxes on Rails/L-Angles and concreting as per DRG. No. SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable throughing and one GI pipe 150mm long 32mm dia for drawal of jumper wires for Point machines etc.., provision of one EWS lock and painting the boxes inside and outside with one coat of red-oxide and to coats of aluminium paints. CT Boxes, Rails/L-angles of differenet length shall be supplied by Railways. (Cement, sand, stone jelly of size 20/25mm, paint, varnish, GI pipes 32mm dia - 300mm long - 2 Nos and 150mm long - 1 No., clamp nuts - 12mm thick- 2 Nos. for each pipe, fixing bolts and nuts with washers, EWS locks and all other miscellanious items required to be supplied by contractor).
Supply of SSBPAC (Digital) for Single Line Pair as per RDSO Specification No. RDSO/SPN/175/2005 Ver. 1 or latest along with station master block panel along with DTMF based Electronic Block Bell & Block Telephone equipment as per specification No RDSO/SPN/191/2005(Ver. 0) or latest (Installation), Microprocessor Lighting & Surge protection Devices for power line 24 DC Class-C, Lighting & surge protection devices for DATA Line Class-D, EKT for Shunt Key as per Drg. no. SA-22601/Alt.4 & IRS: S-21/2001 and associated data cable including wired relay rack with relays. (Inspection RDSO) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply, commissioning of Heat and smoke multi sensor as per RDSO/SPN/ 217/2018 ver-2 or latest along with its base, backbox and all accessories in complaince with IS:2175 and IS:11360 standards and Underwriters Laboratory (UL) listed. (Inspection RDSO)
Supply, commissioning of Fault isolator as per RDSO/SPN/217/2018 ver-2 or latest with backbox and all other accessories, (Inspection RDSO)
Supply, commissioning of linear heat sensing cable as per RDSO/SPN /217/2018 ver-2 or latest. (Inspection RDSO)
Supply, commissioning of linear heat sensing interface module, (Monitor module) for LHS cable with backbox and all other accessories as per RDSO/SPN/ 217/2018 ver-2 or latest in complaince with IS standards and Underwriters Laboratory (UL) listed. (Inspection RDSO)
Supply, commissioning of Networkable single loop addressable Fire alarm Control panel expandable upto 4 loops with GSM interface (without GSM module) as per RDSO/SPN/217/2018 ver-2 orlatest. This work involves supply ,fixing, installation and testing of control panel. The control panel shall be networkable to Zonal /Divisional headquarters preferably over TCP/lP and shall have clock synchronization facility. This includes Networking module (TCP/IP) for control panel along with power supply unit and battery set of required capacity for 24 hours backup as per RDSO specification.. The panel should support degrade mode operation in complaince with IS: 2189 , EN 54 standards and Underwriters Laboratory (UL) listed .(Inspection RDSO)
Supply, commissioning of GSM module for Control panel with backbox and all other accessories as per RDSO/SPN/217/2018 ver-2 or latest. with auto dialer function to SMS during failure or fire situtation. (Inspection RDSO)
Supply, commissioning of Manual call point (resetabble) with backbox and all other accessories as per RDSO/SPN/217/2018 ver-2 or latest. (Inspection RDSO)
Supply, commissioning of Relay module with backbox and all other accessories as per RDSO/SPN /217/2018 ver-2 or latest. (Inspection RDSO)
Supply, commissioning of Hooter and Visual strobe alarm units with backbox and all other accessories as per RDSO/SPN/217/2018 ver-2 or latest along with its power supply unit. (Inspection RDSO) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply, commissioning of Control module with backbox and all other accessories as per RDSO/SPN/ 217/2018 ver-2 or latest. (Inspection RDSO)
Supply, commissioning of EOL as per RDSO/SPN/217/2018 ver-2 or latest as directed by the site Engineers. (Inspection RDSO)
Supply, commissioning of Monitor module for 3rd party with backbox and all other accessories as per RDSO/SPN/217/ 2018 ver-2 or latest. (Inspection RDSO)
Supply and fixing of PVC pipe of 25mm Metre size of IS standards on wall/floor etc All necessary items like screws/nails required to be supplied by contractor. (Inspection RDSO)
Laying / drawing of various type of cables Metre on PVC pipe / capping casing, or cable trays, ladder, shelter etc as instructed by Railway engineer at site. (Indoor cables to be drawn through pipe, outddor cables if required to be clamped on wall/Floor etc)
Supply of multi torn Sounder cum strobe of Numbers more than 80dbA and more than 75cd provided with suitable fitting and accessories. Make" Siemens /Bosch/ Honeywell or better. (Inspection RDSO)
Supply, Commissioning of Electrical operated Lifting barrier complete set operated at 110 V AC/DC with all spares and toolkit as per RDSO specification No. RDSO/SPN/208/2012 Version 2.0 with all amendment -1 or latest and driven mechanism boom as site length (approx 10m), balancing weight, boom support and motorized boom locking arrangement, circuit controllers, operating panel, road warning bell/hooters/buzzers and all accessories complete in all respect as per specification No. RDSO/SPN/208/2012 Version 2.0 with all amendment -1 or latest with all accessories for Electrical operated Lifting barrier including Nut & Bolts with casting of cement concrete foundation for padestal and boom rest post of Electrical lifting barrier for level crossing gate. (Inspection RDSO)
Fixing of EKT instrument with (or) without Numbers crank handle or on suitable fixtures at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire PVC 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting. (Supply of electric key transmitter and crank handles is not covered in this schedule). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility by using 25mm thick teakwood, bolts and nuts, paints, push switches, padlocks and other miscellaneous materials required for this work shall be supplied by the contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Earthing work excavation of foundation cum and other trenches in hard soil (For Sliding boom) (Qty= 10CUM) Total 48713064.45
Item Breakup - 03-Signal Schedule-B1
Laying of HDPE duct 40/33mm dia in the Kilometre trenches and in protective works already provided
Blowing of OFC cable(24F as per RDSO Kilometre specn.TC 55-2006 Rev.1 with amendment 1.1) in already laid PLB HDPE Duct, 40/33mm Dia, by using Blowing machine, providing the sufficient loops in loop/joint chambers and other associated works.
Concreting of cable laid in the trench or GI RMT pipe/DWC/HDPE pipe in which cable is already laid to a size of 300*300mm with 1:3:6 mortar. (All the matetrials required for the work should be supplied by the contractor){Per Unit- RMT}
Excavation of cable trench in all kinds of Metre soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. Laying of cables is not included in this schedule.
Excavation of cable trench in all kinds of Metre soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. Laying of cables is not included in this schedule.
Excavation of trench to a depth of 1 Mtr. Metre for track crossing of cables, laying of DWC/ RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule)
Excavation of trench to a depth of 1 Mtr. Metre for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule). HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Provision of GI pipes (50/100mm dia) for Metre cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor].
Laying telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this schedule).
Refilling of cable trench 1m depth by 0.3m Metre width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling.
Refilling of cable trench 1m depth by 0.5m Metre width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling.
Excavation of cable coil pit to a size of cum 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and leveling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor].
Digging of cable trench to a depth of not Metre less than 30 cms in rocky terrain, concreting the trench with 150mm thick concrete with 1 Cement: 2 sand: 4 graded stone aggregate 20mm nominal size. All the materials to be arranged by contractor
Concreting of cable laid in the trench or GI Metre pipe/DWC/HDPE pipe in which cable is already laid to a size of 300x300mm with 1:3:6 mortar. (All the materials required for the work should be supplied by the contractor).
Excavation of cable trench in hard rocky Metre area/ hard soil including clearing of roots of tree, rocks, bushes etc. to a depth 0.6 m and to a width of 0.5 m and refilling of cable trench of 0.6 m depth by 0.5 m width throught, with earth after laying of cables, and consolidating the trench by ramming and levelling. Laying of cable is not included int his schedule. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Excavation by Manual means in rock and cum very hard rock with hammer / chisel / pavement breaker etc. where blasting is not permitted due to special circumstances and if specifically ordered in writing including drilling and all incidental work in all conditions as directed by Engineer- in- charge. (Without deduction of Equivalent Quantity of Normal Soil)
Track crossing by Horizontal Boring Metre Method based on RDSO Report No. BS - 105. This also includes insertion of HDPE Pipe of 110mm Outer dia in the Bore drilled. (Supply of HDPE Pipe is not included). Total 8166677.00
Item Breakup - 04-Signal Schedule-C
Transportation of Signalling materials by Per Unit road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. (Transportation of Signalling materials more than 100km) Total 292000.00
Item Breakup - 05-Signal Schedule-D
Supply of Electronic interlocking excluding Station panel processor (Hot Standby) for stations with signalling functions upto 125 units as per function table enclosed along with 5% spare, tools, manuals and instruments.
Incremental rate for signalling functions in Each EI System over and above 125 functions under item No. 1 above. ( Unit: Each=Per function )
Supply of portable work station to run Numbers along with EI configuration tools, data inputs, simulation and functional testing, diagnostics and trouble shooting and commissioning of EI system.
Supply 65" (Inch) Digital UHD Signage with Numbers full function Digital Signage display as per technical specification. Make:- LG, SAMSUNG (PM43H), SONY with (3 Year Warranty)
Supply of industrial grade embedded PC Numbers for operator VDU as per RDSO TAN No. STS/TAN/3007 Version 1.0 or latest with adequate storage memory to work in Hot standby mode.
Installation, Wiring, Testing. Soldering of El all El equipments earthing of EI equipments, relay rack and Power Equipment etc. including supply power cable and Documents/Manuals etc.
Training Engineers/Officers.
Commissioning of Distributed Electronic El lnterlocking system. Total 38585117.82
Item Breakup - 06-Telecom Schedule-A
Supply of 10 pair switch Board cable of Metre 0.6mm dia/Delton make or similar as per TEC spec No GR/WIR 06/03 of march 2002. ( Inspection Consignee )
Supply of HDPE Duct 40/33 ( OD/ID) dia in Kilometre (500/1000 Mtr) as per Spec GR No. G/CDS- 08/02 Nov 2004 with latest amendment ( Inspection Consignee )
Supply of STP CAT 6 cable as per Boxes RDSO/SPN/TC/65/2019 Rev.5.0 with latest amendment Firm's Make/Brand:NETWORK CABLES.(1Box=305meter)( Inspection Consignee )
Supply of 1 Quad / 2T VF Transformer 470 : Numbers 1120 (Cylindrical Type ) as per RDSO specn No. IRSTC :76/2001 with amendment No. 1 or latest ( Inspection Consignee )
Supply of 20 pair CT box with WAGO Numbers terminal ( Inspection Consignee )
Supply of Emergency socket Box as per Numbers RDSO DRG.No TCA-20060(ADV) with 6 PIN Emergency socket as per specification No.IRS.TC-42/87 with amendment no.3 or latest Firm's offer- emergency socket box in M.S Material Body as per RDSO DRG.No TCA-20060(ADV) with 6 pin emergency socket as per RDSO specification no. IRS: TC-42/20 version 1.0 Make Telecom, HSN Code IS 8517 ( Inspection Consignee )
Supply of GI pipes - 50mm dia -3.65mm Metre thick as per Technical specification ( Inspection Consignee )
Supply of Master Telephone of Electronic Numbers LC gate communication system as per RDSO Spec No.RDSO/SPN/TC/51/2021 Rev.3.0) Amdt 1 or latest.( Inspection Consignee )
Supply of Slave Telephone of Electronic LC Numbers gate communication system as per RDSO spec No.RDSO/SPN/TC/51/2021 (Rev.3.0) Amend - 1 or latest.( Inspection Consignee )
Supply of 24V DC Power Supply unit with Numbers MF Battery for master & slave phones for Electronic LC gate Telephone System as per RDSO, RDSO SPN/TC/51/2021 Revision -1.0 or lates ( Inspection Consignee )
Supply of 2/4 wire combined portable Numbers control phone as per RDSO specification IRS TC 75/99 with MENDMENT NO.04. Accepted make: Industrial instruments & controls.( Inspection Consignee )
Supply of 4 wire DTMF way station Numbers equipment as per RDSO specification No. IRS-TC 60/2007 with amendent no 1 latest wirth 4 wire control telephone as per specification no IRS TC 38/97 with Amendent No.1 latest ( Inspection Consignee ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of Power Supply Unit for Way Numbers Station Equipment with MF Battery 12 Volt / 7 AH as per RDSO Specification No IRS- TC-72/97 with Amdt. 1 or latest. Make Epsilon or similar Firm' Offered Make: INDISCO ( Inspection Consignee )
supply & configuration of PCM TDM Numbers integrated access multiplexer 1u height /19 rack mountable with 8e1 port ( with 1+1 protection ) cable e1 db 37/8 rj 45- 1 no. unit to support 124/128 DSO level cross connect unit to support dual DC/48v & power supply adopter- 1 no. suitable for existing equipment maple 4cs. firms offer: make/model: MROTEK & team eng( Inspection Consignee )
Supply of E&M card suitable to be Numbers accomodated in maple 4C Multiplexer with 8 channel 2W/4W configureable with one number of 50 pin SCSI connector cable. Firms offer make/model: MROTEK ( Inspection Consignee )
Supply maintenance Free (SMF) Batteries for 25W VHF radio Communication Use. As per specification enclosed with 24 months warranty: Make: Panasonic, Exide, Amaron, Quanta or HBL only ( Inspection Consignee )
Supply and transportation of Thermo Numbers shrink jointing kit RTSF4 for quad cable as per RDSO specification No.IRS.TC:77-2012 (rev.3) or latest. Thermoshrink jointing kit for jointing underground 0.9mm dia. Cond 4/6 quad cable as per specification no IRS TC77/2012 (rev.3) with amend. 1,2 &3 or latest. ( Inspection Consignee )
Supply of basic materials to construct unit Numbers maintenance free earth as per RDSO spec.No RDSO/SPN/197/2008 or latestand confirming to RDSO Drg.No SDO/RDSO/E&B/001 dtd 19.09.2018. It consist of following : Copper bonded steel electrode of 3.0m long 17.2 mm dia with coppper bonding thickness of minimum macrons and UL listed and marked 1 No Earth enhancement material supplied in sealed bags of minimum 10kg = 3Nos "Copper strip of 150x 25x6mm to terminate earth rod=1no. Copper strip of 300x 25x6mm (MEEB)=1no. Copper strip of 150x25x6mm (SEEB)=1no. Supply of 35sq mm mult strand single core PVC insulated copper cable as per IS:694 for connecting main earth electrode in duplicate. Supply of 16 sqmm mult strand single core PVC insulated copper cable as per IS:694 for connecting MEEB to SEEB and SPD to MEEB Supply of 10 sq mm mult strand single core PVC insulated copper cable as per IS:694 for connecting various equipment to SEEB " ( Inspection Consignee )
Supply of Double Walled corrugated pipe- Metre 103.5mm inner dia & 120mm outer dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as specified in Vol.II of the Tender document.( Inspection Consignee ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY Total 990925.61
Item Breakup - 07-Telecom Schedule-B
Fixing of 20 Pair CT box and termination of Numbers cable at the station/LC gates etc. this includes fixing of PIJF cables and CT box on the wall with necessary wooden
Fabrication, installation and fixing of Numbers emergency socket post, box and emergency socket as per the drawing No.OHE/1.6A/94 (enclosed). These emergency socket posts to be fixed alongwith the cable route at an interval of not more than 1 km .As per the dia
Supply & Installation of 4 Wire DTMF Head Numbers quarters Control room Equipment as per RDSO Specification No.IRS-TC 60/2007 Amdt 1 or Latest ( Inspection Consignee )
Supply, Installation and Commissioning for Numbers 4 Port Gateway to support 4 PortConcurrent Emergency Communication at HQ /W ay station to support 4 wire ports/ 4 Port Gateway with built in 2 wires to 4 wire Hybrid convertor to support 4 wire output as Per Clause 13 of RDSO/SPN/TC /99/ 2012 Rev.2 or latest ( Inspection Consignee )
Supply, commissioning of VRLA batteries of 48V 200Ah capacity in charged condition as per technical specification. ( Inspection Consignee )
Supply, installation and commissioning of Numbers 48 V SMPS based FR-BC charger with N+1 configuration of 25 amps basis SMR module equipped with 50 amps as specification no. RDSO/SPN/TL/23/99 VE.4 Amdt 1or latest. ( Inspection Consignee )
Provision of GI pipes(50/100mm dia) for Metre cable laying withoffset at both ends and with coupling over RCC bridges/Drainage/Culverts with concrete mansory supports of size 300mm x 300mm x300mm at an interval of 2m. Thee ends of the pipes shall be closeed with brick mansory abutments work so that no cable is exposed. THe work shalll be carried out as per the instructions of Railway representive at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule.) [ Stone jelly of size 20/25mm, bricks, sand, cement and other miscellaneous materials required for the work shall be supplied by the contractor).( Inspection Consignee ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of Digital Clock suitable for Office Numbers Complex with GPS synchronisation in standalone mode (Colour of LED:Red) as per clause 6 of RDSO Specification No. RDSO/SPN/TC 62 /2008 Rev.3.0 or latest along with GPS receiver as per Clause 8 of this specifications. This includes Supply and installation of complete GPS clock and receiver in Control Offices of Bhavnagar Division as per direction of Railway Site engineer of the Consignee( Inspection Consignee )
Installation of unit maintenance free earth Numbers as supplied in schedule includes 1)Digging of earth to required depth 2) insertion of electrodes 3)Filling of earth enhancing compound (Approx. 30kgs 4) Provision of exothermic weld connection to copper tape of 25mm x6mmx 150mm 01 no to earth electrodesrequired for weld will be arranged by the contractor) 5) This includes CC cover 1.5ftx 1.5ft 1 ft wall thickness 2" with cover 3" thickness. Cables 35sqmm/ 16qmm/10sqmm for connecting earth to bas bar, busbar to busbar, busbar to various equipment. Earth electrode of 17mm dia and 03m long high tensile low carbon steel circular rods and outer surface (minimum cupper bonding thickness of 250 micron to made requirement of under writers laboratories (UL) 467-2007 or latest. Copper strip of 150x25x6mm to be welded with each electrode, Copper strip of 300x25x6mm for main equipment-potential busbar in relay room , power room and panel room. Copper tape 25mmx2mm for ring foermation of earth enhancement material in bags for each earth electrode . Inspection chamber of site 300mmx300mmx300mm(inside dimension of approx 50mm Thich with pulling hooks to cover the earth pits.Note : The installation of this item shall be carried out by the contractor as per RDSO spec.NORDSO/SPN/197/2008 or latest andconfirming to RDSO Drg.No SDO/RDSO/E&B/001 or latest.
Supply and installation of lightening & Numbers surge arrestors of class B & C suitable for single phase supply in TT network as per RDSO Spec.no RDSO/SPN/165/2012 . Or latest. ( Inspection Consignee )
SUPPLY OF 24U RACK specification given Numbers below.1.Depth of the Rack (mm)-Up to 1000.2.Mount Type - free standing. 3.Secure Locks-Available. 4.Support cable entry from top or bottom-Yes5. Numbers of Rack trays - 16.Number of Fan For Heat dissipation (nos)- 4.7.PDU Power Strips- Available.8..Type of glass used in front doorTransparent Toughened Glass. etc make:- Valrack/ ComRACK or similar. with minimum one year warranty ( Inspection Consignee )
Supply, commissioning of 24 Fiber Management System with SC connectors including splicing, suitable accessories, etc ( Inspection Consignee ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of 230V AC/48V DC operated Single Pair channel Fiber to Ethernet media converter similar to make of Cisco/MRO-TEK/D- Link.Firm's Offer: Dlink DFE-855S- 15I,10/100Base-TX to 100Base-FX (SC) 10Km Single modemode Media Converter DFE-855S-15I 10 Kms Single mode Media converter Built-in a 2-port switch that supports modified cut-through frame forwarding packet forwarding system. Supports bandwidth control supports IEEE802.3u 100Base-TX, 100Base-FX (Fast Ethernet, 100Mbps) Built-in 128KB RAM data buffer Supports auto MDI-MDIX function Supports far end fault function LED display for link/activity, full/half,10/100M Longest transmission up to distance 120 km Easy Management ( Inspection Consignee )
Supply and fixing of OFC patch cards 5 Numbers Mtrs length as per site requirements ( Inspection Consignee )
Supply of 2 meter CAT 6 Patch cord( Numbers Inspection Consignee )
Supply of 20 Pair Krone Termination box Numbers complete with mounting arrangement.02 Nos of Krone modules with 10 ports each module.Suitable to connect 0.6 mm wire.With frame plate.Box made of MS sheet with 0.8mm thickness.Cable entry holes with washers.Powdered coating.Lock and key system. ( Inspection Consignee )
Installation of 100/50/20 Pair Krone Numbers Terminal Box as supplied vide NS items on hard wood plank of size 8"x13"x1" plank and wiring. Hard Wood plank and other materials like screws, bolts etc to be supplied by the contractor at his own cost.
Supply and installation of 6U wall Numbers mounting rack of reputed make with standard accessories as one tray, spike buster, fan tray etc of make D- Link, CP plus or better ( Inspection Consignee )
Supply of Single push button telephone Numbers similar to Panasonic ABS Telephone instrument single push button Panasonic (KX-TSC60) ( Inspection Consignee )
Supply of 8 port managed non PoE layer 2 Numbers Access switch similar to IHT 8 Port switch(S2082M)( Inspection Consignee )
Supply of PVC pipe 25mm dia, round Metre conduit, as per Indian standard, of reputed make, confirming to IS:9537 (Part) - 1983 (reaffirmed 2007) or latest.( Inspection Consignee )
Supply of 25mm casing capping similar to Metre Atul ISI Marked FRLS PVC conduits ( casing caping beet one inch)( Inspection Consignee )
Fixing of PVC pipe or casing & capping, Metre using bends, couplers, T-joints & flexible pipe wherever necessary with fixtures. (All required materials for fixing like clamps, bends, couplers, T-joints & flexible pipe, etc are to be borne by the contractor. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of 25 watt VHF Digital Radio Set as Numbers per RDSO Specification No.RDSO/SPN/TC/107/2018 Revision: 0.0.or Latest:, Item D with standard microphone, Antenna, Antenna Cable of 30 metre length connector, with 12 Volt DC 10A, Power supply equipment for above 25 Watt Digital Radio Set with 12V,100AH,VRLA Battery. Firm offers Make/Brand "Motorola Make Digital XiRM8668i Radio".( Inspection Consignee )
Supply and installation of OFC Joint closure Numbers conforming to TEC Spec. and splicing of Optic Fibre Cable' (48 Fibres) and testing of fibre for 1310 :1550 nm. (Inspection by Consignee)( Inspection Consignee )
Supply & installation of Jointing pit as per Numbers drawing with cover and required trenching to ease out cable/duct. (Inspection by Consignee)
Providing dry sand in FRP/RCC chambers uptp 400mm height.
Laying of HDPE duct in trenches supply Metre and pulling of nylon rope through it.
Blowing of armoured optic fiber cable (OFC Kilometre cable supplied by Rialways ) into the duct supplied vide NS.2 of supply portion by using blowing machine and associated works. Before blowing the duct integrity shall be tested. If a n y defect is found during duct integrity test, the entrie lenght of HDPE duct from one chamber to another chamber is to replaced by the contracror at free of cost ,
Laying telecommunication cables as per cable plan in cable trenches, mansory ducts, RCC pipes, DWC pipes, GI pipes, PVC pipes etc (Supply of cables is not included in this schedule).
Straight through/derivation with/without Numbers transformer joints: Installation Thermo shrinkable jointing kits for straight through /derivation joints for LC gate, pump houses etc where VF transformers are not required and derivation joint by using 2T transformer (to be housed in the joint). This includes tapping of nominated Quad at a specific location shown by the Railway Engineer at site to the jelly field cable already laid.All materials including valco tapes except thermo shrinkable jointing kit shall be supplied by the contractor.(Refer Annexure for instructions on cable jointing)
Excavation of square coil pit upto a depth Numbers of 1 Mtr.x 1.5 Mtr for providing coil at locations box,point,signals etc This includes back filling and ramming of trench/pit after laying the cable and consolidation of soil.
Transporting and supply and installation of Numbers concrete (RCC) route indicators at intervals of 50 mtrs as per technical specification They should be of standard RCC with Letters"SWR Telecom cable" as per type of cable laid to drawing.In case of telecom quad cable joint locations it shall be painted with red colour. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Concreting the pipes trench in which cable Metre is already drawn with concrete 30 cm x 30 cm thick using 1:2:4 ratio & back filling with exacavated soil. (Cement, sand metal are to be supplied by the contractor). This is also applicable for concrete platforms /metal/tar/cement roads.
Excavation of trench to a depth of 1 Mtr for Metre track crossing of cables, laying of DWC/RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not inculded in this schedule). Total 1087861.21
Item Breakup - 08-Telecom Schedule-B1
Excavation of cable trench in all kinds of RMT soil except hard rockty area including clearing of roots of tree,rocks,bushes etc to a depth of 1.0 Mtrs and to a width of 0.3Mtrs .Laying of cables is not included in this schedule.
Digging of cable trench to a depth of not RMT less than 30cms in rocky terrain concreting the trench with 150mm thick concrete with 1 cement 2 sand and 4 graded stone aggregate 20mm in size. All the material is to be arranged by contractor.
Refilling of cable trench 1m depth by 0.3m Metre width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling Total 328020.00