| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹4.7 L+₹635.23 (0.14%)Rejected-Finance | L2 | Rejected-Finance Being L2 Bidder | |
| 3 | L3₹4.7 L+₹1,583.90 (0.34%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bidder |
| Sl No | Description | Qty | Unit | RAKSHIT CONSTRUCTION L2 | CHANDA CONSTRUCTION L3 | SEKHAR CHANDA L1 |
|---|---|---|---|---|---|---|
| 1.00Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] | ||||||
| 1.01 | Avg. run 6 Mtr [4(b)/ E-25 ] | 27 | Pt. | 875 ₹23,625 | 876 ₹23,652 | 873 ₹23,571 Lowest |
| 1.02 | Avg. run 8 Mtr [4(c)/ E-25 ] | 30 | Pt. | 1,075 ₹32,250 | 1,076 ₹32,280 | 1,073 ₹32,190 Lowest |
| 2.00Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with MODULAR type switch as per GS. | ||||||
| 2.01 | On Board [ 3 (i) / E- 20 ] | 7 | Pt. | 249 ₹1,743 | 250 ₹1,750 | 248 ₹1,736 Lowest |
| 2.02 | 4.5 mtr. [ 3 (iv) / E- 20 ] | 4 | Pt. | 938 ₹3,752 | 939 ₹3,756 | 937 ₹3,748 Lowest |
| 3.00Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works | ||||||
| 3.01 | 20 mm size [ 7(a)/ E- 16 ] | 90 | mtr | 51 ₹4,590 | 52 ₹4,680 | 50 ₹4,500 Lowest |
| 3.02 | 25 mm size [ 7(b)/ E- 16 ] | 80 | mtr | 69 ₹5,520 | 70 ₹5,600 | 68 ₹5,440 Lowest |
| 4.00Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. | ||||||
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
4 Oct 2024, 4:00 pmClosed
Executive Engineer,Hooghly Electrical Division,PWD
Office of The Executive Engineer, PWD, Hooghly Electrical Division , Purta Bhavan 3rd Floor , Sarat Sarani , Kodalia
Electrical Installation work of duty rest room with toilet including SITC of AC machine at doctor rest room at Serampore Walsh SD Hospital,Serampore, Hooghly Electrical Installation Work.
2024_WBPWD_759451_1
WBPWD/EE/ HED /SHORT/ NIeT-101 of 2024-25
Open Tender
Electrical Work/ Equipment
Item Rate
5 days
Hooghly
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,000
7 Sept 2026
28 Sept 2024
7 Oct 2024
28 Sept 2024
4 Oct 2024
28 Sept 2024
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Avg. run 6 Mtr [4(b)/ E-25 ]
Avg. run 8 Mtr [4(c)/ E-25 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with MODULAR type switch as per GS.
On Board [ 3 (i) / E- 20 ]
4.5 mtr. [ 3 (iv) / E- 20 ]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
25 mm size [ 7(b)/ E- 16 ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
19 mm dia 3 mm thick [ 6 (a)/ E- 3 ]
25mm dia 3 mm thick [ 7 (a)/ E- 3 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by E.I.C) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm) + 1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ] For AC Point
2x (6 sqmm) + 1x (4 sqmm) [1(y) / E- 9 ]
S & F solderless Copper socket by crimping of Copper wires.
1.5 sq mm [9(i) / F-5]
2.5 sq mm [9(i) / F-5]
4 sq mm [9(ii) / F-5]
6 sq mm [9(iii) / F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS
175 x 100 x 65 [11(c)/E-4 ,13(c)/E-5]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
2 Row 12 Module 1(e)/E-17]
6 module 1(b)/E-17]
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board as per GS [ 20( a )/D-13 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/Siemens/L&T as approved by E.I.C. )
4 Way (Make - Make - Legrand/Siemens/L&T as approved by E.I.C] [ 14 / D- 10 ] .
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+12 Way [Siemens /Schneider or equivalent model of Legrand/L&T] as approved by EIC. [ 13 / D- 9 ]
2+8 Way [ Make - Legrand/Siemens/L&T as approved by E.I.C).[ 13 / D- 9 & D-10 ]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make NICCO/ Gloster/KEI/Havells as approved by E.I.C]
4Core 25 Sq. mm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc [5(i)/F-3]
Laying of cable upto 2/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [ 2(A)/ F- 1 ]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4Core 25 Sq. mm [7(c)/F4 ]
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.
4Core 25 Sq. mm [ 8(b-xiii) /F5]
Supply & Fixing Modular type 240 V, 16A, 3 pin plug socket with separate 16 A Modular type switch on sheet metal switch board embedded in wall as per GS. [Legrand-Model Arteror/Myrius or equivalent model of Crabtree/ Schneider) [ 9(b) / E-18]
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket ([Legrand-Model Arteror/Myrius or equivalent model of Crabtree/ Schneider) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 9(a) / E-18]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a)/E-17]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[17/E-19]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections [5(b)/E-17]
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent model of Havells/CG / Bajaj / Wipro as approved by E.I.C] incl. 1 no. 18W Master LED Tube
Twin fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3242 or equivalent model of Havells/CG / Bajaj / Wipro as approved by E.I.C] incl. 2 no. 18W Master LED Tube
Fixing only single/twin LED batten light fitting suspended from the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Fixing only single/twin LED Batten light fitting complete with all accessories Directly on wall/ceiling as per GS.[ 14d/C-2 ]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [ 22/D-13 ]
Supply of 14 W LED bulb(Bajaj/CG/Philips/wipro) on existing batten holder. [NS]
Fixing only lamp[ 11/C-2 ]
Supply of ceiling fans with brust proof P2/S3 Capacitor complete with all accessories without regulator(Make-Usha- Striker or equivalent model of CG/Orient)
a. 1200 mm Sweep
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Supply & fixing 450mm sweep wall bracket fan(high speed) with metal body & blades(Orient-Wall-II Tornado or equivalent cat of CG/EPC/Cinni) with necessary wooden board on wall with nuts, bolts, washer etc.
Supply of heavy duty Exhaust fan(Make-EPC] of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust incl. s&f louver shutter as per G.S. )
12"( 300mm ) Speed 920 RPM (Make-EPC Heavy Duty)
9"( 230mm ) Speed 1370 RPM (Make-EPC Heavy Duty)
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For GI
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification as per GS. [ 29/D-14 ]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) ([Legrand-Model Arteror/Myrius or equivalent model of Crabtree/ Schneider) ) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18]
S & F of 240V, 50Hz digital time switch (Mk- L&T, AUTS02DIG00 or equivalent model of Havells/Hager) on existing MCB SS enclosure and making necessary connection with exhaust fan including time setting as per direction of EIC.
S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25 A DPMCB(C-curve 10ka) and 1 no 24 hr analog time switch and 2 noS 25 A power contactor complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC. (For 02 nos. Split AC )(Make-L&T/Siemens/ABB)
S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25 A DPMCB(C-curve 10ka) and 1 no 24 hr analog time switch and 1 no 25 A power contactor complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC. (For 01 no.Split AC )(Make-L&T/Siemens/ABB)
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
40mm dia [11(c)/F-6]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level [ By TATA-Medium GI pipe] [2(a)/G-1].
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming for Morrum Soil. [1(b)/G-1]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-10 SWG [5(a)(iv)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2]
Add GST @18%
Add LWC @1%
RAKSHIT CONSTRUCTION (BID ID -5675417)
CHANDA CONSTRUCTION (BID ID -5676076)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .