| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹41.1 L+₹2.3 L (5.97%)Rejected-Finance KRISHNA NAGAR BOOTY RANCHI 835217 | RANCHI | JHARKHAND | 835217 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹41.5 L+₹2.7 L (6.93%)Rejected-Finance C O MANOJ KUMAR KESHRI MIRA SADAN ROAD NO 03 ANAND VIHAR NEAR WAXPOL FACTORY BOOTY MORE BUTI RANCHI JHARKHAND 834012 | RANCHI | RANCHI | JHARKHAND | 834012 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹42.2 L+₹3.4 L (8.72%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹42.3 L+₹3.5 L (8.96%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹38.3 L
EMD Value
₹76,700
Closing Date
25 Nov 2021, 6:00 pmClosed
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT P.O. HOTWAR RANCHI - 834012
SPL TO BLDG No P-356 OF EME BN, SPL REPAIR TO BLDG No. P-352 OF FWC AND SPL REPAIR TO ROOF TREATMENT OF OTM ACCN BLDG No P-15, P-16 AND P-17 OF FD HOSP AT DIPATOLI MIL STN
2021_MES_479753_2
8000/1750/E8
Open Tender
Civil Works
Item Rate
180 days
Dipatoli
Class D
Category a(i)
8 documents required · 8 mandatory
₹500
Yes
Ranchi
₹76,700
Yes
6 Dec 2021
13 Nov 2021
27 Nov 2021
13 Nov 2021
25 Nov 2021
20 Nov 2021
Amount
Demolition of cement concrete(reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended wor etc complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete(un-reinforced) of any description and in any position not otherwise specifically provided for etc complete all as specified and as directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed by Engr-in-Charge.
Taking down chawkhat (without taking off shutter) exc1.5 but n.exc4sqm each, complete all as specified and as directed by Engr-in-Charge.
Taking down eaves gutters and rain water pipes (any size or patterns) including all fittings,heads,shoes,bends,swan-necks etc complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15 mm thick on brick surface in CM (1:4) mixed with WPC as per manufacturer instructions and finishes surfaces even and smooth with out using extra cement. Note - WPC will be measured and paid separtely
M&L rendering on other than fair faces of brick work 15mm thick in CM 1:6 and to be finished smooth and even with out using extra cement for internal surface complete all as specified and as directed by Engr-in-Charge.
M&L Rendering 5mm thick in cm 1:3 on ceilling. surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
Supply only liquid water proofing compound.
M&L Reinforced cement concrete in mix 1:1½:3 (using 20mm graded aggregates) in chajjas etc complete all as specified and directed.
M&L mild steel deformed TMT bar 10mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by Engr-in-Charge.
M&L formwork flat to chullah hoods, chajjas, troughs and similar items including edges fair finished surfaces complete all as specified and directed.
Form work to edges of concrete flats, treads, opening in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls etc for fair finished complete all as specified and directed.
M&L for repair and rendering 10mm thick in cm 1 :3 on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs complete all as specified and as directed by Engr-in-Charge.
M&L mild steel works as in framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes and similar works conforming to Fe-290, Gde-E165 etc complete all as specified and as directed by Engr-in-Charge.
S&F PVC(SWR) pipe 110 mm dia single socketed in any length with rubber ring joints, fixed to wall with and including stack and clamp complete all as specified and as directed by Engr-in-Charge.
S&F PVC(SWR) bends any radius 110 mm dia complete all as specified and as directed by Engr-in-Charge.
S&F steel rolling 1.2mm shutters, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated,complete: but gear operated type with bevel gear box and crank handle and Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed by Engr-in-Charge.
S&F pressed steel frames of size 125 x 60 mmx1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed by Engr-in-Charge.
M&L PCC 1:2:4 type B1 20mm grade aggregate as in padding, hold fasts/filling of chowkhats or similar work complete all as specified and as directed by Engr-in-Charge.
S&F 35mm Flush shutters(ISI Marked) solid core construction, with block board core and plywood, commercial type on both sides complete all as specified and as directed by Engr-in-Charge.
S&F mild steel sliding door bolts 300mm long complete all as specified and as directed by Engr-in-Charge.
S&F 100mm size MS butt hinges, medium weight cold rolled complete all as specified and as directed by Engr-in-Charge.
S & F 200mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by Engr-in-Charge.
S & F 150mm long Aluminium handle cast type anodised complete all as specified and as directed by Engr-in-Charge.
S&F small fitting shaped door and window stops n'exc 200 cucm each of 2nd class hard wood complete all as specified and as directed by Engr-in-Charge.
S & F Butt hinges medium weight cold rolled stainless steel, and fixed(50mm) complete all as specified and as directed by Engr-in-Charge.
S&F factory made steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete with glasing bars dovetail ed or welded all complete all as specified and as directed by Engr-in-Charge.
S&F factory made steel ventilators with top hung shutters including hinges,steel peg stay complete all as specified and as directed by Engr-in-Charge.
M&L in applying two coats of synthetic enamel paints over a coat of red oxide primer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and as directed by Engr-in-Charge.
M&L for prepartion on old painted surfaces of steel and iron surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M & L preparation of new surfaces & apply two coats of synthetic enamel paint over one coat primer exc 10 cm width/girth including preparation of new surface on wooden surface complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint on wooden surfaces complete all as specified and directed.
M&L two coats of cement base paint over one coat of primer including preparation of new surface all as specified and directed.
M&L for preparation of new surfaces and applying Three coat of white wash on wall including cornices etc complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new surfaces and applying three coat of white wash on ceiling including cornices etc complete all as specified and directed by Engr-in-Charge.
Complete removal of existing treatment and preparing the surface of walls and apply two coat of cement base paint over a coat of cement primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old surfaces and applying one coat of white wash on wall including cornices etc complete all as specified and directed by Engr-in-Charge.
All as per Ser item No 39 above but on ceiling complete all as specified and as directed by Engr-in-Charge.
Hacking out old broken glass any thickness from metal/wooden frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed by Engr-in-Charge.
S & F Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane 3mm thick complete all as specified and as directed by Engr-in-Charge.
M&L PCC 1:3:6 Type C2 (40mm graded aggt) 75mm thick without using extra cement as in Path/plinth protection complete all as specified and as directed by Engr-in-Charge.
Roof treatment for non approachable roof including complete removal of existing roof treatment :- (i) Rendering 10mm thick in cement mortor (1:3) mixed with liquid water proofing compound finished the surface fair and even.(ii) Applying evenly a coat of bitumen primer @ 0.30 Kg/Sqm. (iii)Applying APP modified polymeric membrane over the bitumen coat surface ,weight not less than 3.20-3.50 Kg/Sqm and over lap 100mm and sealed by torch application as per manufacture insteructions. (iv) Applying a coat of aluminium paint @ 200 gm/sqm in two coats over polymeric membrene.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc, complete all as specified and as directed by Engr-in-Charge.
Brushing neat cement slurry with 3.00 Kg of cement per sqm complete all as specified and as directed by Engr-in-Charge.
M&L Machine cut kota stone slab flooring 20-25 mm thick set over and including 15mm thick screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with beewax polishing complete all as specified and as directed by Engr-in-Charge.
All as per item No-47 but here-in-before as in skirting over 10mm thick cement plaster in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
Taking down chowkhat with shutter without taking off shutter from chowkhat not exceeding 1.5 Sqm each complete all as specified and as directed by Engr-in-Charge
S&F Powder coated aluminium frame for windows/door with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F Powder coated aluminium window shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S & F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beadingscrews etc. complete all as specified and as directed by Engr-in-Charge.
M&L for 18/19 mm thick preliminated particle board Exterior grade but prelaminated both sides with decorative choice laminations complete all as specified and as directed by Engr-in-Charge.
S&F Sheet glass,4.mm ordinary quality and glazing with in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engr-in-Charge.
S&F Sheet glass,4.8mm ordinary quality and glazing with in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engr-in-Charge.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average with of aperture 1.18mm and fixed with tinned tack, or galvanised wire staples
M&L for light shade vitrified ceramic tiles 10mm thick (square/rectangular)polished,area of each tiles n exc 0.36sqm over 15mm thick screed bed in CM (1:6) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-Charge.
ditto as per item No 22 above but in skirting dado etc over 10mm thick cement plaster in CM (1:4) complete all as specified and as directed by Engr-in-Charge.
M&L for preparation surfaces by washing ,rubbing down and stoping of distempered and pointed surface of wall and applying two coat of distemper oil emulsion white or tinted over primer on wall surfaces all as specified and directed.
Taking up or down steel tubing and connections including for refixing or removal 15mm borecomplete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing and connections including for refixing or removal 20mm borecomplete all as specified and as directed by Engr-in-Charge.
S&F steel tubing and connection in new or old position to walls,ceiling,floors etc complete all as specified and as directed 15 mm bore medium grade , with all fittings ,fitted to wall and ceiling or laid in floor complete all as specified and as directed by Engr-in-Charge.
S&F steel tubing and connection in new or old position to walls,ceiling,floors etc complete all as specified and as directed 20 mm bore medium grade , with all fittings ,fitted to wall and ceiling or laid in floor complete all as specified and as directed by Engr-in-Charge.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.
Supply only integral water proofing compound. (Make - ACCO PROOF/WATER SEAL/ IMPERMO)
M&L for roof treatment in repair by complete removal of existing old treatment and treated with following specifications:- (a) Brushing neat cement slurry @ 3kg per Sqm on roof slab (b) 15 mm thick in cement plaster fair finished using cement motar (1:4) mixed with liquid water proofing compound. (c) Applying oil based bitumen primer @ 0.30 ltr/Sqm on plasterd surface. (d) Applying modified APP polymeric membrane 3 mm thick and minimum weight 4.00 Kg / Sqm for water proofing of roof , sealing as directed at site with 100 mm over laps as per manufactures instruction. (e) Appling two coat of aluminium paint @ 200 gm /sqm over bituminous surface of membrane. Note:- Supply only WPC shall be measured and paid separately under relevant item.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed.
Taking down old/unserviceable DB SPN any capacity by disconnection of electric connection including MCBs,Isolators,etc and making good to disturbed surface complete all as specified and directed.
Taking down Old/ Unserviceabl MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC conealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces.
All as per Ser item No 72 here-in-before but one 3 Pin Socket out let 5 Amps on the same board.
All as per Ser item No 72 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board.
All as per Ser item No 72 here-in-before but one bell/buzzer point controlled by one push button on the independent board.
All as per Ser item No 72 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed.Make :- Havells /HPL/Anchor
S&F Switch piano type , single pole , one way15 Amps complete all as specified and directed. Make :- Polycab/Havells/Anchor
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed .Make :- Polycab/Havells/Anchor
S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.Make :- Polycab/Havells/Anchor
S&F in replacement electric Bell, ding dong type AC 230 Volt single pole complete all as specified & directed at site.Make :- Polycab/Havells/Anchor
S&F in replacement Bell push 5 Amps for electric Bell/Buzzer, AC 230 Volt single pole complete all as specified & directed.Make :- Polycab/Havells/Anchor
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.Make : Polycab/Havells/Anchor
S&F electronic regulator step type 230 Volts single phase 120 watt complete all as specified and directed at site.Make:- Polycab/Havells/Anchor
M&L for lamp holder , PVC /Polycarbonate type with back plate suitabl for batten fittings complete all as specified and directed at site.Make : Polycab/Havells/Anchor
S&F in replacement of sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps to 32 Amps complete all as specified and directed at site. Make-Polycab/Havells/Anchor
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No-87 here-in-before but 2X2.5 Sqmm and 1X 2.5 Sqmm for Earth wire complete all as specified and as directed by Engr-in-Charge.
All as per ser item No-87 here-in-before but 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire complete all as specified and as directed by Engr-in-Charge.
All as per ser item No-87 here-in-before but 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire complete all as specified and as directed by Engr-in-Charge.
Supply and fix MCB DB SPN 12 way double door with metal door suitabl for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directedcomplete all as specified and directed at site. Make -Legrand /Havells/HPL/Schneider
Supply and fix MCB DB TPN 4 way with metal door suitable for Provision of incommer MCCB-100A and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. Make -Havells Part No.DHDLVDRWGOFO04 /Schenider /Legrand.
Supply and fix in replacement MCCB 3Pole 415 volts 100 Amps 50 Hz Adjustable type, with breaking capacity 10 KA complete all as specified and directed at site. Make : legrand/Havells/L&T.
S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. Make Havells /Schenider /Legrand.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles.Make -Havells /Schenider/Legrand .
S&F in replacement of isolator DP 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of LED tube light fitting 18/20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site. Make : - Cat/part No. LUMILINEPLUSBS18WLED865SPCSS of Havells or equivalent in Philips/LUKAR/C&S
S&F in replacement of building LED security light fitting 35 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site.Make : Havells Cat No:-ENDURACITYLITEPLATPLUSSL35WLED 757SASYBOPC or equivalent in Philips/C&S
S&F in replacement of Ultra slim LED panel tube light fitting 36 watt 230 Volt made from extruded aluminium housing frame (recesss/pendant) 2' x2' Complete with all accessories internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site. Make : Cat/part No LSVR01S036XN of Jaguar/ /Havells cat part No.LHEWBPP7PL1w036/ Indus plus of HPL
M&L for repair/rewinding&greshing of ceiling fan of any size sweep single phase.Celing fan of any size opening from any hight or any locations, fan opening from hook,clamp,& refixing the same after rewinding, cleaning and greshing with requird necessary cutting/welding/granding job or required store such as nuts,bolts,bearing,washer and suitable length mild steel/ down rod duly making holes etc complete as perspecified and directed by Engr -in -Charge.
S&Fof Metal body ventilating air fan single phase 250 mm sweep complete with louver shutter. Quoted rate has been inclusive of all labour charges for making of hole in existing building for fixing of exhaust fan, as per suitable size fan base after cutting of brick/stone wall /suitable size as required, complete all as specified and directed. Make : Havells model ventil Air - DB or equivalent as per list of makes.
S&F in replacement of environmental friendly, ultra modern, energy saving, surface mounted, decorative oval plastic bulk head LED light fittings 10 watt capacity ,comprising of high brightness LEDs, IP54 protection complete with all accessories internally pre-wired and inncluding connecting up with 2/3 core twisted flexible copper conductor cable with suitable size of flexible PVC/steel Conduit complete all as specified and directed at site . Make : Havells Cat part No. HEXAFT 10WLED 87SSYMBOPC or equivalent in Philips/ HPL
Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as specified.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick complete all as specified and as directed by Engr-in-Charge.
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed.Note : Punned down thickness shall be considered for measurement .
Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed
M &L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr in Charge.Note :- i) Earthing test must be carried out in presence of Engr-in-Charge. ii) The earthing result not more than 2 Ohms or disered earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
M/S OMANIA ENTERPRISES
M/S.R.S.Chauhan and Sons
M/S SHAMBHU SHARAN SINGH
m/s sheo kumar singh & sons
united builders
Associated Engineers
M/s Ray construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .