Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.2 LAccepted-Finance | ₹20.2 L | 1 | Accepted-Finance L-1 |
| 2 | 2₹22.0 L+₹1.8 L (8.93%)Accepted-Finance 0 SITHAULI KALA MOHANLALGANJ LUCKNOW GOSAIGANJ MOHANLALGANJ UTTAR PRADESH 226301 | LUCKNOW | UTTAR PRADESH | 226301 | ₹22.0 L+₹1.8 L (8.93%) | 2 | Accepted-Finance L-2 |
| 3 | 3₹23.9 L+₹3.7 L (18.1%)Accepted-Finance | ₹23.9 L+₹3.7 L (18.1%) | 3 | Accepted-Finance L-3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
Tender Value
₹26.5 L
Closing Date
11 Jan 2022, 3:30 pmClosed
EE CD Jaipur
Jaipur
Construction of Office Rooms Toilet Bathroom with Septic Tank Boundary Wall Paver block and Wire Fencing work at Kateela Site under Lower Chambal Sub division CWC Jaipur
2021_CWC_665968_1
CD-J/HQ-NIT/2021/13, Dated 30.12.2021
Open Tender
Civil Works
Works
75 days
Jaipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
Executive Engineer Chambal Division CWC
Exempted
22 Mar 2022
30 Dec 2021
12 Jan 2022
30 Dec 2021
11 Jan 2022
30 Dec 2021
Amount
OFFICE ROOM
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Providing and laying in position cement concrete of 1:4:8 (1 cement: 4 sand (zone III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.
Centring and shuttering work including strutting, propping etc. and removal of form for:- Foundations, footing, bases of columns etc. for mass concrete
Centring and shuttering work including strutting, propping etc. and removal of form for:- Lintels, beams, plinth beams, girders, bressumers and cantilevers. For Plinth Beam
Centring and shuttering work including strutting, propping etc. and removal of form for:- Columns, pillars, piers, abutments, posts and struts. For Column from Ground Level to roof slab (8 Nos. Column x 4 side=32)
Centring and shuttering work including strutting, propping etc. and removal of form for:- Suspended floors, roofs, landings, balconies and access platform. For Roof Slab
Providing and laying in position specified grade of reinforced cement concrete of 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. For Foundation
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), For Pillars
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size)upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand). For wall above Trapezoidal portion to Plinth Beam(L=48-8x0.30=45.60 m.)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (1.5% of Total wt. of RCC work) (Wt.= 21.983*1.5*7850/100)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand). For outside Stairs.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) : From Plinth beam to roof slab
Providing and fixing sloping chajja of stone 40 mm thick and upto 80 cm wide beyond the wall as measured along the slope in cement mortar 1:4 (1 cement : 4 coarse sand) with 12 mm diameter anchoring steel bar, 45 cm long, fixed in each stone and supported on and including with bricks cove in cement mortar 1:4 (1 cement : 4 coarse sand), including pointing in cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : White sand stone: With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
12 mm thick cement plaster in fine sand of mix 1:6 (1 cement : 6 fine sand).
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete., (Qty same as Qty of plastering)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. (Qty same as Qty of plastering)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Kota stone 25 mm thick slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer using flats 30x6mm for diagonal braces and central cross piece.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes of 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5°, 110 mm bend
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required: Group B
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator): 12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia. (heavy type). For Doors and Windows (W= 5*(1.8+0.2)=10 m.) (D = 3*(1.2+0.2)=4.2m) (Total 10+4.2 = 14.2 m. or say 15 m.)
Toilet and bathroom with Septic Tank
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drain (not exceeding 1.5 m in width or 10 sqm on plan) Including dressing of sides and ramming of bottom, lift upto 1.5 m , including getting out of the excavated soil as directed , within a lead of 50 m. all kinds of soil.
Providing and laying in position cement concrete of 1:4:8 (1 cement: 4 coarse sand (zone III): 8 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering - All work up to plinth level.
Brick work with common burnt clay F.P.S. (Non modular) Brick of class designation 7.5 in superstructure in cement mortar 1:6 (1 cement: 6 course sand).
Providing & Laying Damp Proof Coarse D.P.C. 40 mm. thick with cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources): Septic Tank Wall
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Precasting Slab for Septic tank
12 mm thick cement plaster in fine sand of mix 1:6 (1 cement : 6 fine sand)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) Copping work above parapet wall
Centering and shuttering work including strutting, propping etc. and removal of form for:- Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering work including strutting, propping etc. and removal of form for:- Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering work including strutting, propping etc. and removal of form for:- Circular Septik tank wall- Well steining
Providing laying in position cement concrete flooring with 1:2:4 (1 cement: 2 course sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, including cement slurry complete: 40 mm thick with 20 mm nominal size stone aggregate (PCC under Floor)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: new work (Two or more coats) over and including water thinnable priming coat with cement primer.
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joint 35x5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-in-charge.
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanized M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Sanitary Installation:
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rest
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100 mm dia, Sand cast iron S&S as per IS - 1729
Providing and fixing terminal guard : 100 mm dia, Sand cast iron S&S as per IS - 1729
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipe
Polyethylene water storage tank with cover and suitable locking arrangement
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia
Electrical Fitting Work
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group C
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Boundary Wall
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. all kinds of soil. For Pillars
Providing and laying in position cement concrete of1:5:10 (1 cement: 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering All work upto plinth level, For Pillars
Centering and shuttering work including strutting, propping etc. and removal of form for:- Foundations, footing, bases of columns etc. for mass concrete:
Centering and shuttering work including strutting, propping etc. and removal of form for:- Lintels, beams, plinth beams, girders, bressumers and cantilevers. For Plinth Beam
Centering and shuttering work including strutting, propping etc. and removal of form for:- Columns, pillars, piers, abutments, posts and struts. (22 Nos. pillars x 4 side=88)
Providing and laying in position specified grade of reinforced cement concrete of 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources), excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), For Pillars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand), For wall (L=67-22x0.23=61.94 m.)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
12 mm thick cement plaster in fine sand of mix 1:6 (1 cement : 4 fine sand).
White washing with lime to give an even shade new works (3or more coats ), Qty same as Qty of plastering
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (For Fencing L-section Iron Angle 45x45x5 mm, Weight = 3.4 kg per meter)
Fencing with angle iron at required distance embedded in cement concrete block every 15th post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals inter woven with horizontal wire weighing 9.38 kg per 100 m (minimum between the two posts filled and fixed with GI stapler turn buckles etc. complete cost of post struts, earth work and concrete work to be paid for separately, payment to be make per meter cost of total length of barbed wire used.
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. Width of one Angle = (0.045+0.045)x2 = 0.18
Painting with synthetic enamel paint of approved brand and manufacture to sign an even shade. Width of one Angle = (0.045+0.045)x2 = 0.18
Structural steel work in single section, fixed with or without connecting plate including cutting hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (For Main gate with L section Iron Angle 50x50x5 mm @ 3.8 kg/m. andIron plate 30x5mm @ 1.2 kg/m.)
Wire Fencing for ORG and outside of Office Boundary
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. Iron Post for Fencing. ISA 45*45*5 mm of 2.6 M HEIGHT (3.4 kg per meter).
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. Width of one Angle = (0.045+0.045)x2 = 0.18
Painting with synthetic enamel paint of approved brand and manufacture to sign an even shade. Width of one Angle = (0.045+0.045)x2 = 0.18
Structural steel work in single section, fixed with or without connecting plate including cutting hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (For Gate of ORG Fencing & outside Fencing - with L section Iron Angle 45x45x5 mm @ 3.4 kg/m. and Iron plate 30x5mm @ 1.2 kg/m.)
Interlocking Paver Block
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:. all kinds of soil.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
SOMYA ENTERPRISES
M/S SANJAY SHARMA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .