Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 CrAccepted-AOC | ₹35.6 Cr Quoted ₹37.2 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹38.4 CrRejected-AOC 5 217 D1 TEACHERS COLONY MOHANUR ROAD NAMAKKAL 637001 | NAMAKKAL | TAMIL NADU | 637001 | ₹38.4 Cr | L2 | Rejected-AOC Rejected |
| 3 | L3₹39.1 CrRejected-AOC 201 3RD FLOOR A BLOCK SRI GURU TOWERS 80 FEET ROAD ANNA NAGAR MADURAI 625017 | MADURAI | TAMIL NADU | 625017 | ₹39.1 Cr | L3 | Rejected-AOC Rejected |
Tender Value
₹34.9 Cr
EMD Value
₹17.6 L
Closing Date
8 Feb 2024, 3:00 pmClosed
Superintending Engineer PWD
Office of the Superintending Engineer PWD Buildings Construction and Maintenance Circle Chepauk Chennai 5
Construction of 100 Bedded Critical Care Block/Speciality Block at Government Royapettah Hospital, Chenani-14.
2024_PWD_419673_1
TNPWD/51 BCM 04/2023-24
Open Tender
Construction Works
540 days
Royapettah
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹17.6 L
24 Mar 2024
6 Feb 2024
8 Feb 2024
6 Feb 2024
8 Feb 2024
6 Feb 2024
Amount
Installation Charges inclusive of Transportation to site and the Bored pile equipment employed for the works including setting up of pile driving equipment with all accessories and tools at each of the pile location based on the sequence of operation approved by the departmental Engineers irrespective of the location and distance involved in movement of pile driving equipment etc., complete.
Installation of Vertical Bored cast in situ RCC piles in all types of soils, using Ready Mix Concrete of M 30 grade, with sulphate resistant Cement, fine aggregate, 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost of reinforcing steel, binding wire, fabrication, welding charges, placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavation of mud pits for circulation of Bentonite solution, closing the mud pits to original level and mud removal
with initial lead and lift but excluding dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing should be as per clause 15.2.2. The length of pile for payment shall be measured upto natural ground level. The work should be carried out as per IS 2911. Pile depth should be decided by the departmental officers at site.
600 mm dia pile having longitudinal main reinforcement of 8 Nos 20# with helical reinforcement at 10 # @ 200mm C/C with inner rings of 12 # @ 1000mm C/C with lifting hook of 12 # at required length.
450 mm dia pile having longitudinal main reinforcement of 8 nos 16# with helical reinforcement at 8 dia at 150mm centre to centre with inner rings of 12 dia at 1000mm c/c with lifting hook of 12 dia at required length
Initial Load Test as per IS 2911 Part IV 1985 including cost of single pile (250% of pile capacity), labour, reinforcement charges and all other incidential charges including excavation, shoring, strutting, dewatering etc. as necessary hire charges for jacks, measuring devices, Structural Frame work for platform, Kent ledges etc, as required and providing pilecap.
Routine load test as per IS 2911 part IV 1995 (150% of pile capacity) including labour charges for jack, measuring devices, structural frame work plot form, kent ledges etc., as required and as directed by the departmental officers etc. complete.
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling M.sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with Stone Dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Providing pre constructional Anti-termite treatment for the construction of building including cost of chemicals labour as per standard specification. Labour for preparing the area for treatment by spreading chemicals and other incidental charges complete. The rate shall be inclusive of giving anti termite treatment to the building for the following four stages including breaking the termite moulds making holes with crow bars at an interval of 12" to a depth of 8" in the periphery of the building including flooring area and pouring chemicals etc., complete as per ISI 6313/1981.
Cement Concrete 1:5:10 (One Cement, Five M.sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials)..
Foundation and Basement
For Ground Floor
For First Floor
Second floor
Third floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Providing and Fixing of PVC Trims (Corner beeding) at the outer corner profiles of the tiles including cost of material, labour and handling etc. as directed by departmental engineers at site of work and as per standard specification.
Brick work in Cement Mortar 1:5 (One Cement : Six Sand) using best quality fly ash bricks 230 x 110 x 75mm for Superstructure including curing, etc., complete complying with standard specifiction.
For foundation & basement
Brick work in following Cement Mortar using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS:12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:6 for load bearing structures for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction. In Cement Mortar 1:6
Ground floor
First floor
Second floor
Third floor
Brick partition walls of 11.50cm thickness using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
Ground Floor
First Floor
Second floor
Paving the floor with best approved quality fine polished Granite Stone Slabs of approved colour of size 1200 x 600 of 18 / 20mm thick with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with matching colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification.
Paving the floor with best approved quality lapato Granite Stone Slabs of size 1200 x 600 of 16 / 18mm thick laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with matching colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification.
Paving the floor with best brandaed quality Double charged Vitrified anti - skid Tiles of size 600 x 600 x 10mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with kota stone laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing of wall with Special type of ceramic wall tiles of approved quality, colour and design of size 600x600x8mm thick in all floor over a base layer in CM 1:2, (one of cement and two of sand) 10mm thick and laid in situ, in true alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 to suit the colour of the tiles fixed in position with out any air gap in the tiles etc., complete complying with std. specification and as directed bythe deptl. officers. The colour & quality of tiles should be got appd. by the EE before use on work.
Cladding the vertical wall surface with best approved quality fine polished granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick with machine cut edges laid over a cement mortar bed of 10mm thick using cement mortar 1:2 (One cement and two sand)
Supplying and fixing Ornamental Teak Wood door of overall Size 6.00 x 3.00m with the door opening of 3.00 m & balanced portion fixed both side of shutter made of toughned glass having designed to elegant look .. FRAME : outer frame of well Seasoned Teak wood scantlings of size 8” x 6” with required carvings and rebates to suite the door shutter. .The Frame should be fixed in position with necessary anchorage such as heavy duty holdfasts by dismantling the R.C.C or stone Masonry and redoing the same to the original position with Cement Concrete and adhesive material required for the job so as to keep the frame in vertical position and true to the plumb. The frame should also be embedded into the floor by making necessary dismantling on the floor and redoing the same to its original position after placing the same.
Supplying and fixing solid core flush shutter 35mm thick with Teak ply on both sides, teak lipping alround with necessary adhesive and C.P.screws, including fixing for aldrop , tower bolt, hinges and lock strike plates , putty, fevical etc., and including the cost of aluminium hinges 125x 30mm size -3 Nos. aluminium aldrop of size 250x16mm 1No, Aluminium tower bolt of size 250x12 mm -1 No. , Aluminium tower bolt of size 200x12mm-1 No, aluminium door stopper with Nylon bush-2No. shall be provided. All aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 for anodic film thickness of not less than 15 microns. The rate is inclusive of cost of fevical, fixing charges, transportation, loading, unloading all other incidental charges and handling charges etc., complete complying with standard specification.
Single leaf
Double leaf
FRAME:Fully Solid Core WPC-75MMX50MM:Providing and Fixing of Qute WPC/PVC Solid Door frame extruded with size 75mmx50mm.The inner core made of rigid WPC Compound with minimum shore hardness of 55,and Bulk Density 0.8 Grms/Cub.C.mt.The frame shall be fixed fixed to the wall using 10x100mm long M.S.Screw through the frame by using PVC Fasteners.A minimum of 4nos screws to be provided for each vertical member
Supplying and fixing of wood polymer composite (WPC) door with solid door frames extruded with size 75mmx50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55 and buld density 750kg/cub.Mt. The frame shall be fixed to the wall using 10x10mm long MS screw throught the frame by using PVC fasteners. A minimum of 4nos screw to be provided for each vertical members, Door Shutter of 25mm thick Wood Polymer Composite (WPC) single core Extruded Door Shutter, with one side digital printing of specified Design which is approved by engineering-in-charge. Both side of the shutter shall have rough sugar texture finish, laminated with UV oil. The solid WPC board shall have minimum shore hardness of 55 and Bulk density 550kg/cub.Mt moulding the thickness remains 25mm (+/-1mm) etc. complete as per the direction of the departmental officers.(make Qute / Equivalent)
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Providing and Fixing, UPVC factory made, white colour sliding Door made of extruded profiles. Sliding frame 60 mm X 62 mm, Sash 66 mm x 42 mm, Bead 16 x 24.5mm. Profiles of frames and sash will be mitered cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2±0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8mmx100mm long fasteners, all complete as per direction of Engineer-in-charge.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 74mmx60mm x 56mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames with grill and net mesh.
Supplying and fixing of M.S.grill of approved design for open courtyard, grill, grill work to doors and window openings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
Providing and fixing 2 hr fire rated doubble skin ste door constructed from 1.25mm thick galvanized ste sheet formed to provide a 46mm thick fully flush door shl with lock seam joints at stile edges and the internal construction of the door is a specially designed Honey Comb structure with reinforcements at top, bottom and stile surrounds. As per IS 3614 part-1 & part-2 for stability and integrity and Pressed Galvanized ste confirming to IS 277.
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
Brick Jelly lime concrete 1:2:5(one lime, two sand and five brick jelly) using 40mm gauge brick jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor finish, curing etc., complete complying with standard specifications (for flooring in toilet portions except water closet portions)
Ground Floor
First Floor
Second Floor
Plastering with Cement Mortar 1:3 (One Cement and Three P-Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Treatment to side wall of varying thickness of basement floor, Lift pit, of main building from exterior surface covering the following sequence of operations :
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing and bonding agent Cebex 112,Zydex-Zyecrete 2x or other equivalent compound to be added etc. complete complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:3 (One Cement and Three P.Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Supplying and applying of two coats of Putty 3mm thick over the exposed RCC Surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be througly cleaned out of dust and scrubbing the surface shall than be allowed to dry for atleast 48 hours. It shall be than sand papered (Waterpoof abrasive sheet) to give a smooth and even surface. any uneveness shall be made good by applying 1 st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2 nd coat of putty after 6 hours of 1 st coat of putty and then sand papering ( Waterpoof abrasive sheet) the same after its dry and finishing the surface smoothy etc.,complete complying with standard specifiction and as directed by the departmental officers.(The rate inclusive of hire charges for grinding machine with wheel,cost of sand paper(Waterpoof abrasive sheet) cost of putty blade,labour charges for grinding the joints and sand papering,two coats putty,scrapping the putty area to level the surface smooth etc., complete). The putty should be got approved by the Execuctive engineer before use on work.
Painting the wall with Texture Finish Paint including labour charges
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supply and installation of Anutone (or) Euivalent Brand of Acoustical False Ceiling of subtex nubby, square edge, glass fibre core fully encapsulated ceiling tile of size 595 x 595 x 15mm having volume density 120 Kgs / m3, weight 1.8 / 2.4 / 3 kg / m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. Skelet trelis T15 metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angle with unequal flanges of 15 / 19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally, the skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600 x 600mm module. The subtex nubby square edge of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc. complying to standard specication.
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm colour glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware ovel shaped wash hand basin of size 560 x 450mm including , 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works)..
Without Pedestal
Providing & fixing Stainless Wash Sink of size 600 x 450 x 200mm depth with border width of 50mm icluding folding of edges of approved make, connection pipe of approved make & CP waste coupling over the Granite Platform including providing SS vertical splash board of 600mm ht.along with fixing G.I. waste pipe of 32mm dia ‘C’class Approved make below the sink upto Nahani trap through required fixing arrangement like Jam nut etc. complete as directed by the departmental officers .
Providing and fixing CP bottle trap including cost of materials, labour etc., complete as directed by the departmental officers
Providing and fixing CP health faucet with two in one bip cock (including supply & fixing two way taps including cost of materials, labour etc. complte as directed by the departmental officers.
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying and fixing in position SS Swan Neck Tap of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works.
Supplying and fixing in position UPVC unions of heavy duty of approved quality and good variety of various sizes inluding necessary cutting and threading of UPVC pipes for jointing the union and providing two coats of painting with good variety and approved quality of synthetic enamel paint over one coat of primer in case of pipe line above ground level / one coat of tar in case of below ground level for both internal and external water supply arrangements, etc., complete complying with standard specifications. (The UPVC unions should be got approved by Executive Engineer before use on works).
Supplying and fixing in position UPVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the UPVC pipes dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specification and as directed by the departmental officers. (The UPVC specials should be got approved by the Executive Engineer before use on works). (For both in internal and external water supply arrangements)
Reducer Tee
32mm x 25mm dia
25mm x 20mm dia
20mm x 15mm dia
Elbow
32mm dia
25mm dia
20mm dia
32mm dia
25mm dia
20mm dia
Supplying, laying and jointing CPVC Pipes of approved quality and best variety of pipe of the following dia including labour fixing UPVC Specials, (excluding charges for cutting of pipes, cost of such specials) to wall with necessary teak wood plugs, clamps, screws, UPVC Solution etc., making holes on the walls (or) drilling holes in roof and making good the dismantled portions to original condition with necessray brick work / concrete and plastering wherever necessry with necessary scaffolding charges. complete in all floors complying with standard specification. UPVC pipes shall be got approved by the Executive Engineer before use on works.
Supplying CPVC Specials in water supply arrangements (both in internal and external water supply arrangements
Elbow
Coupling
Union
Supplying and fixing in position the following foam core pipe grade SN8 complete complying with standard specification including cost and conveyance of all material as directed by the departmental officers.
Supplying and fixing in position the following foam core pipe grade SN8 specials complete complying with standard specification including cost and conveyance of all material as directed by the departmental officers.
160mm dia Door Bend
160mm dia Door Elbow
110mm dia Door Bend
110mm dia Door Tee
110mm dia Plain Bend
110mm dia Single Y Junction with Door
110mm dia Cowl
160 mm dia 'Y' with Door
110mm dia Elbow with Door
Construction of Manhole chambers at various depths including earthwork excavation as per S.S - 20 B, crushed stone sand (M-sand) filling, laying of C.C 1:5:10 using 40mm HBGS Jelly for foundation and Brick work in C.M 1:5 for side walls, plastering the wall outer side in c.m 1:4 (12mm thick) and inner side in c.m 1:3 (20mm thick) and providing manhole chambers with SFRC frame with cover, providing C.I steps inside the chambers etc., complete
Clear size of 0.60x0.60x1.20m
Clear size of 0.90x0.90x1.20m
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
Supplying and fixing approved best quality aluminium anodised towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)
Providing the safeguard for the columns for 1m height with rubber corner guard of 3"x3" L type colour of black and yellow approved quality etc. complete complying with standard specification and as directed by the departmental officers.
Paving the floor with Tactile Paver Type of New Tek BT Yellow Colour Ceramic Tiles of size 305 x 305 x 15mm for Vision Impairment Person laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Supplying and fixing of cylindrical vertical notational polythene water storage tank confirming to IS. 12701 / 96. The tank is meant for outer (or) indoor, use complete with removable hinged top locking arrangements and to make provision to fix with simple pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tank, and the tank should be fixed firmly. The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., complete complying with standard specification and as directed by the departmental officers. (The water tank should be got approved by the Executive Engineer before use on works by the Departmental Officers.
Supplying and fixing of 5 H.P submergible Pump set of approved brand etc complete complying with standard specification and as directed by the departmental officers.
Providing REGISTRATION COUNTER / NURSE STATION of required size by arranging openable cupboard of size 0.90mx0.60 mx0.75m on either side of the workstation at 1.50m apart and top finished with 20mm polished granite top laid over 18mm BWR plywood with suitable adhesive and edges are chamferred. The cabins are fixed with openable drawers 2 Nos at top with roller arrangement for easy operation and bottom portion with openable shutters of side hung with lock and key arrangement fixed in vertical of 18mm(BWR) plywood. The face of the work station is provided with vertical desk top of 0.30m wide and 0.30m height run for the entire length of nurse station. and with half door of horizontal opening and vertical opening on either side of the cabin so as to operate for easy access.The nurse station so fabricated shall be fixed on the different location in the building and polished with melamine varnish of approved quality and brand including preparation of surface. The rate is inclusive of cost of all materials, conveying from the source to workspot, loading, unloading and lifting to various upper floors, labour for wrought and put up etc and cost of furniture fittings, fixing in position and finishing neatly. The rate is also inclusive of all local taxes etc. complete complying with standard specification and as directed by the departmental officers.
Suppling and fixing position of polycorbonate sheet (Opaque White) roofing with following specification. The roofing made of 10 mm thick multi wall polycarbonate sheet roofing with following specification. The roofing made of 10mm thick multi wall polycarbonate sheet with approved colour (Lexan branded) double sided UV coated using MS frame work consists of main truss 50 x 50 mm MS square pipe for vertical support in the base plates and top connecting plate for fixing truss. The rate including cost of 10mm thick multi wall polycarbonate sheet, MS truss work, MS vertical support pillars, Horizontal purlins, Aluminium plate for bottom & top with sealent for all joint of sheets and labour charges for all fabrication works and sheet fixing work and necessary Scaffolding cost and painting work for all MS Truss with purlin etc., completed. and as directed by departmental officers.
Supplying and fixing the aluminium anodised fixed glazing partition using 63.50mm x 38.10mm x 1.50 mm @ 0.818 Kg/cm box section for all members and 5.50mm thick plan glass for pnales. The aluminium frames are at 0.60m c/c in both horizontal and vertical directions with necessary triangle shape glazing clips of 19mm x 17.30mm x 0.75 mm @ 0.124 Kg/cm and the rubber beadings for glass pnales including labour charges for fabrication, conveyance, cost of power consumption charges and dismantling, making holes in R.C.C. / masonry wherever necessary with power drill to the required extent and make good to the original condition after fixing the partition as directed by the departmental officers.
Supplying and fabricating and fixing in position aluminium anodised partly top 1/2 galzed and partly bottom 1/2 panelled door and frame made out of box section 101.6x44.45x3.18mm thick at 2.319 kg\m door shutter made out of box section 47.1x44.45x2.5mm at 1.202 kg\m for vertical style and top, lock rail sections of size 50x44.50x2.5mm @ 1.292 Kg/m and bottom 100.4x44.45x2.50mm at 1.974kg\m using clips of size 17.15x17.27x1.5mm at 0.176 kg\m with necessary metal screws, rubber beading, strike plate type handle of size 100x30x1.60mm at 0.988 kg\m on both sides, tower bolts, lock pivot arrangements and top 1/2 portion with 5.50 mm thick plain glass and bottom 1/2 portion with one side prelaminated board ( MDF ) 12mm thick for panel portion with 1 No. of hydraulic door closers of approved quality using aluminium extruded section body tubler type universal with double speed adjustment with ISI monogram including cost of furniture fitting such as Pivot, hinges, Tower bolt, lock, door stopper and all materials labour power consumption required for fabrication drilling required for fabrication drilling holes in RCC columns floorslabs masonry wall wherever necessary with power drills to the required extent and make the same to original condition after fixing and as directed. All the aluminium sections are to be anodised with matt finish under electrically controlled condition in accordance with IS 1868-1962 for an average anodic flim thickness of 15 microns etc., complete. The materials should be got approved by the Executive Engineer before use on works. The rate shall be inclusive of all materials, labour for fixing transportation loading, unloading, and all other incidential charges. (Single leaf door)
Supplying and fixing Hydraulic Door Closer of various sizes of approved quality using Aluminium Extruded section body tubuler type universal hydraulic door closer with double speed adjustment like HARDWYN make GAZEL (or) equivalent (with ISI Monogram)
Plain Cement Concrete 1:1-1/2:3 for levellling course screed (one cement, two sand and four hard broken stone jelly) using 6-10 mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
Single nosing to the the granite slabs by cutting the granite slabs for 18mm to 20mm thick edges semicircular shape to required size and nosing with semicircular shape and polishing using hand machine and the nosing is made highly smooth and glossy.The cost includes labour charges and cost cost of machineries and polishing charges,etc.,complete as directed by the departmental officers.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) partition using from the profile the size of outer frame 74mm x 60mmx56mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations ree pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Providing vertical joint 12mm wide between RCC twin column from top of pedestal including filling the inner space with suitable non absorbant
Providing covering the expansion joints in vertical surfaces with 3mm thick, 150mm wide aluminium sheet using plugs including cost of materials, labour, handling, painting ,testing of joints etc. complete
Providing expansion joints of 12mm wide in RCC floor slab with necessary PVC water stopper of 150mm wide with center bulb and with 4mm to 6mm thickness of approved quality and brand including filling the inner space with suitable non absorbent flexible compressible filler materials of approved quality and brand providing polysulphide sealant of approved quality to a depth of 7.5mm each top and bottom using gun grade qulaity etc., complete and as directed by the deprtmental officers. Rate is inclusive of cost of materails and labours charges for cutting fixing PVC water water stopper, packing materials and poly sulphide sealents etc., as per standard specification.
Supplying and applying of two coats of Putty 3mm thick over the exposed RCC Surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be througly cleaned out of dust and scrubbing the surface shall than be allowed to dry for atleast 48 hours. It shall be than sand papered (Waterpoof abrasive sheet) to give a smooth and even surface. any uneveness shall be made good by applying 1 st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2 nd coat of putty after 6 hours of 1 st coat of putty and then sand papering ( Waterpoof abrasive sheet) the same after its dry and finishing the surface smoothy etc.,complete complying with standard specifiction and as directed by the departmental officers.(The rate inclusive of hire charges for grinding machine with wheel,cost of sand paper(Waterpoof abrasive sheet) cost of putty blade,labour charges for grinding the joints and sand papering,two coats putty,scrapping the putty area to level the surface smooth etc., complete). The putty should be got approved by the Execuctive engineer before use on work.
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End )
Wiring with 3 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End.
Supply and fixing of 20W, 4 feet LED fitting with conduit pipe Suspension on ceiling with PVC unsheathed copper leads from terminals to the fitting
Supply and fixing of 20W, 4 feet LED fitting on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting
Supply and fixing of 2x2 36W LED recessed mounted Luminaries fitting (Havells Pluto Make) with conduit /chain suspension and with PVC unsheathed copper leads from terminal to the fitting with necessary connection.
Supply and fixing of 2x2 36W LED Surface mounted Luminaries fitting (Havells Pluto Make) on ceiling with PVC unsheathed copper leads from terminal to the fitting with necessary connection.
Supply and fixing of 1200mm (48”) Sweep AC ceiling fan (Crompton High speed) complete with stepped electronic 300W regulator with 0.3 mtr down rod on the existing clamp
Supply and fixing of 300mm (12”) sweep (light duty) AC Exhaust fan without provision of hole in the wall.
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan
Renewal by Supply and fixing of WT bulk head fitting with guard suitable for LED with 7W bulb.
Supply and fixing of 1000 W automatic electronic heater of 25 liters capacity suitable for 230 V 50 c/s AC supply on suitable MS clamps with 3 core flex wire but without plumbing work.
supply and fixing of 60W LED street light fitting with LED (Lower end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. higher End
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 1 number 3 module IP55 Plexo box with PVC membrane suitable for 6A/16 A 3 pin socket with 6A/16A modular switch with necessary connection. (Switches, boxes and plates are of Anchor Roma make)
Supply and fixing of 2 no. 6A two module socket, 1no.6/16 A two module socket , 2 nos. 6A one module switch, 1 nos. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug)
Supply and fixing of 32A DP MCB in sheet steel enclosure with wall with earth connection (For AC Plug)
Supply and fixing of 63A FP MCB in sheet steel enclosure with wall with earth connection (For AC Plug)
Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 4 of 10 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and Run of 4 of 16 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and fixing of 12 way single and neutral MCB sheet steel enclosure distribution load with double door (Mental) with 1 No 32A DP MCB switch as incoming and 10 numbers 6A to 32Asp as out going on wall with earth connection.
Supply and fixing of 4 way Horizontal TPN DB with acrylic door cover of IP 43 protection in sheet steel enclosure with 100A FP MCB isolator as incoming 2 Nos 63A TP MCB and 6 Nos SP MCB as outgoing on wall with necessary earth connection.(The DB and MCBs are of Hager make)
Supply and fixing of 8 way vertical TPN DB with acrylic door cover of IP 43 protection in sheet steel enclosure with 1with 1 no. 100 A 4P MCB Isolator as incoming and 3 nos. 32A 3P MCB , 15 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only.(The DB and MCBs are of Hager make)
Supply and laying of 31/2 x185 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good
Supply and clarnping of 3-1/2 x 185 PVC LTUG armoured cable on post or on wall with MS clamps
Supply and providing cable end termination of 3-1/2 x185 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armoured LTUG cable with earth connection.
Supply, Erection, Testing & Commissioning of 400 A capacity cubical type panel board dust and vermin proof made of 16SWG sheet steel for outer body and stiffness and doors with main switches supports respectively of the following cubical mounting main switches with center bus bar chamber and vertical covers, and cable chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in I.S specifications suitable for floor mounting type. (Incoming) 400A TPN switch disconnector fuse units interior switch only with HRC fuse double break -1no,- Hager Legrand /L&T /siemens /Equ. (Out Going) 250A TPN switch disconnector fuse units interior switch only with HRC fuse double break -4 no,- Hager Legrand /L&T /siemens /Equ. 125A TPN switch disconnector fuse units interior switch only with HRC fuse double break -3 nos,- Hager Legrand /L&T /siemens /Equ. Space for fixing display board.
A Separate chamber on Top of one side should be built with one set of multi meter,[ammeter, volt meter, Hz. Meter with R Y B LED pilot lamps set with fuse base, top with 10A HRC link for 3 phases and CT coil (Siemens) the bus will have suitable 4 Nos. of 50 x 6mm bus for phase and 25x3 mm earth bus all round the panel to provide earth connection to the cubical switches cable glands cable adopter box etc, bus should be mounted on synthetic enamel compound bus supports at equal interval as per IS specifications. The incoming 400A TP switch should be connected with 50X6 mm to the bus,250A switches with 37x6mm flat and 125A Switches with 25mmx6mm bus of rigid copper flat. The switches should be separated by 6mm thick hylem sheet separators and properly (double) earthed as per IE rules, CEIG specification. The panel should be Powder coated, the cable size capacity of switch location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel supports .
supply, Erection, Testing & Commissioning of 250 A capacity cubical type panel board dust and vermin proof made of 16SWG sheet steel for outer body and stiffness and doors with main switches supports respectively of the following cubical mounting main switches with center bus bar chamber and vertical covers, and cable chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in I.S specifications suitable for floor mounting type. (Incoming) 250A TPN switch disconnector fuse units interior switch only with HRC fuse double break -1no,- Hager Legrand /L&T /siemens /Equ. (Out Going) 125A TPN switch disconnector fuse units interior switch only with HRC fuse double break -4 no,- Hager Legrand /L&T /siemens /Equ. 63A TPN switch disconnector fuse units interior switch only with HRC fuse double break -2nos,- Hager Legrand /L&T /siemens /Equ. Space for fixing display board.
A Separate chamber on Top of one side should be built with one set of multi meter,[ammeter, volt meter, Hz. Meter with R Y B LED pilot lamps set with fuse base, top with 10A HRC link for 3 phases and CT coil (Siemens) the bus will have suitable 4 Nos. of 37 x 6mm bus for phase and 25x3 mm earth bus all round the panel to provide earth connection to the cubical switches cable glands cable adopter box etc, bus should be mounted on synthetic enamel compound bus supports at equal interval as per IS specifications. The incoming 250A TP switch should be connected with 37X6mm to the bus and 125A Switches with 25mmx6mm bus of rigid copper flat.,63A witches with 8SWG copper rods The switches should be separated by 6mm thick hylem sheet separators and properly (double) earthed as per IE rules, CEIG specification. The panel should be Powder coated, the cable size capacity of switch location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel supports .
supply, Erection, Testing & Commissioning of 250 A capacity cubical type panel board dust and vermin proof made of 16SWG sheet steel for outer body and stiffness and doors with main switches supports respectively of the following cubical mounting main switches with center bus bar chamber and vertical covers, and cable chamber on both side of the bus bar chamber at the extreme ends on both side and confirming in I.S specifications suitable for floor mounting type. (Incoming) 250A TPN switch disconnector fuse units interior switch only with HRC fuse double break -1no,- Hager Legrand /L&T /siemens /Equ. (Out Going) 125A TPN switch disconnector fuse units interior switch only with HRC fuse double break -8 no,- Hager Legrand /L&T /siemens /Equ. 63A TPN switch disconnector fuse units interior switch only with HRC fuse double break -2nos,- Hager Legrand /L&T /siemens /Equ. Space for fixing display board.
A Separate chamber on Top of one side should be built with one set of multi meter,[ammeter, volt meter, Hz. Meter with R Y B LED pilot lamps set with fuse base, top with 10A HRC link for 3 phases and CT coil (Siemens) the bus will have suitable 4 Nos. of 37 x 6mm bus for phase and 25x3 mm earth bus all round the panel to provide earth connection to the cubical switches cable glands cable adopter box etc, bus should be mounted on synthetic enamel compound bus supports at equal interval as per IS specifications. The incoming 250A TP switch should be connected with 37X6mm to the bus and 125A Switches with 25mmx6mm bus of rigid copper flat,63A switches with 8 SWG copper rod . The switches should be separated by 6mm thick hylem sheet separators and properly (double) earthed as per IE rules, CEIG specification. The panel should be Powder coated, the cable size capacity of switch location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel supports .
Supply and clarnping of 3-1/2 x 120 PVC LTUG armoured cable on post or on wall with MS clamps
Supply and providing cable end termination of 3-1/2 x120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and clarnping of 3-1/2 x 95 PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and providing cable end termination of 3-1/2 x95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 60W LED street light fitting with LED (Lower end) with 1 metre 32mm dia.GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour .
Renewal by Supply an fixing of Havells JETA IRIS 100W LED flood light - SMD Series with necessary connection. (like Havells Jeta Neo 100W)
Supply and fixing of brass cable gland for 3.5 x 25 sqmm PVC armoured LTUG cable with earth connection
Supply and laying of 3.5 x 25 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
Supply and clamping of 3.5 x 25 sq.mm PVC LTUG ar. cable on post or on wall with MS Clamps.
Supply and providing cable end termination of 3.5 x 25 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete
Supply, Erection, Testing and Commissioning 1 no. 250 KVA diesel generator set of 0.8pf three phase 415 Volts, 50HZ 1500RPM with AMF Panel as Detailled below : Make: "Kirloskar" (A) ENGINE : Water cooled diesel engine suitable for Generator application with a shaft output of BHP -137 at 1500 rpm under STP condition , Generator set rating are as per IS :10001 /BS 5514 /DIN 6271 /ISO 3046 Standard dry type air cleaner ,full flow lube oil filter , fuel filter , inline mono block fuel injection pump with Governor and fuel feed pump , exhaust silencer suitable for canopy Make : Kirloskar / Ashok Leyland/ Equivalent (B)SELF STARTING SYSTEM BATTERY : 2 no 12V , Battery fully charged and capacity per the manufacture's specification , suitable to DC Electric Starter motor , battery charging alternator with connection leads and battery stand
26) 1no. Signal lamp for indicating fails to start 27) 1no. Signal lamp for indicating set running 28) 1no. Signal lamp for indicating battery charger ON 29) 1 set pilot lamp of 3 nos 30) MCCB of 100 A capacity with magnetic over laod release,instant short circuit 31) Rectangular copper bus bars of adequate capacity duly color coded with heat shrinkable PVC sleaves 32) 1 no.mains voltage monitor 33) Hooter/Audio alarm for indicating set fails 34) 1 set timer 35) Audio visual indicator arrangements for a) low lubricating oil pressure b) High water temperature c) Over speed 36) 1 no earth fault relay 37) Isolator to isoalte the neutral (E)ACOUSTIC ENCLOSURE Canopy will be powder coated and fabricated out of 16 SWG CRCA MSSheet , with nut & bolt type , inside lining of fire retardant foam 80/100kg /M3 density of 25 mm thickness as acoustic material . Four hinged doors and onedorr fitted with visible glass and locks . the Generator set base frame is provided with hooks for unloading .Canopy will perform +5deg celsius than Normal ambient temperature .No grouting required on the ground ,level surface capable or withstanding the DG Weight , with all sides open for fresh air and hot air exhaust . the Canopies offered one for output of< 75 DBA at a distance of 1 mtr average around the set conforming CPCB Norms.
(F) BASE FRAME Base frame is fabricated in sheet metal rugged in construction and designed for mounting engine and brushless alternator close coupled with cross mounted on AVM the base frame shall have provision for mounting acoustic on it .(G) FUEL TANK 250 ltrs removable fuel tank shall be fabricated out of 1.6mm.Draw out type fuel tank of capacity designed by the manufacturer with fuel level indicator , with inlet and outlet arrangement , air vent & Drug plug . (H)ERECTION ,TESTING AND COMMISSIONING :Transporting 250KVA DG SET to the site including loading and unloading , Insurance, Excise Duty ,VAT and all other taxes etc . Postioning on the PCC platform etc .Initial filling of Diesel , Engine oil , initial charging of battery and erection , Testing Commisioning for 250KVA DG set (I) WARRANTY : The Warranty Should be as per the Manufacturer and less than 1 Year from the date of Commisioning
Supply and laying of 31/2 X 240 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
Supply and clamping of 31/2 X 240 sq.mm PVC armoured LTUG cable on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3 1/2 x 240 sqmm PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3 1/2 x 240 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete
Supply and run of 25mm x 6 mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.
Supply and filling of Diesel to run the generator set for minimum of 8 hrs on full load for testing and commissioning
Supply and erection of Indoor and outdoor units of 2.0 TR capacity split type Air conditioner unit conforming to ISI 1391 ( Part - 2 ) 1992 with amendment No 1 fitted with Hermetically sealed compressor operation on 230V 50 Hz AC supply system with energy efficient operating system with refrigerant gas R - 22 suitable for high wall mounting evaporator and specification as under general requirement interconnection of pipes and cables.
Supply and erection of 5 KVA capacity Automatic voltage stabilizer suitable for operation on 230V, single phase, 50 HZ, AC supply system with time delay relay and high / low voltage cut off, input voltage range 170V to 270V AC single phase, wall mounting type with necessary clamp.
Supply and fixing of stand for the outdoor unit
Supply and running of 2 nos. of additional copper piping unit
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over with safety certificate of 1 no 15 persons Bed cum passenger lift without Machine Room as per the following specifications. (Make: Kone/ Johnson)
1. Location: CCU Block, Government Royapettah Hospital, Chennai. 2.No of lift: one no 3.Type of lift: Bed cum passenger lift, Machine Room Less 4.Capacity of lift: 15 persons/1020 Kgs 5.Speed: 1m / sec 6.Type of drive: V3F drive with enhanced ride comfort and near zero level functions 7.No of floors: GF+2 Floor 8.Total travel: 6.6 mts approximately 9.Leveling accuracy: high level accuracy with smooth and jerk free stopping 10. Construction of CAR: No.3 hardened sheet high quality stainless steel car and hand rail granite flooring and Perspex false ceiling with LED light fitting 11. Position of machine: Inside the Shaft 12. No of landing service: One in each floor front side- 3 no’s 13. No. of car entrance: one in the front side only 14. Car entrance door: power operated automatic V3F drive center opening sliding SS door 15. Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings. 16.Lift Shaft Size : 1900 mm (wide)x 2400 mm (depth). 17.Lift pit depth:1600 mm 18. Car size:1000 mm (width)x2400mm (depth) x 2200 (Height) 19. Car clear opening: 1200 mm wide x 2000 mm height. 20.Lift machine room size: Not Applicable
21. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light. 22.Control: micro computer (micro processor):based simplex collective control with / without attendant 23. Car fittings: LED lighting with 2 nos 300 mm sweep cabin fan. 24. Lift well: RCC construction with brick masonry existing. 25. Induction: UP / DOWN digital direction and position indicator for all landings and inside the car. 26.Emergency alarm bell: battery operated bell to be provided with automatic charging device 27.Emergency light: battery operated light to be provided with automatic charging device 28.Fire mans switch: to be provided at the GF 29. Minor builder works: to be provided by the lift contractor. 30. Scaffoldings: to be provided by the lift contractor. 31. Sill angles and facia plates: SS to be provided by the lift contractor. 32. Steel for lift machinery: to be provided by the lift contractor. 33. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor. 34. Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories. 35. Provision for intercom with phone: to be provided by the lift contractor.
36.Lift license: preparation of drawings payment of charges to CEIG and insurance policy and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor 37. Floor position announcer: to be provided by the lift contractor. 38.Special features a) Infra red door sensor with full height screen b) Full width half height rear panel mirror c)Tubular SS hand rail in car d) Stainless steel signal features e) Vandal proof SS button with SS cover f) SS door frames for landing doors g) V3F door operator h) Call register signal i) Stainless steel facia plates for car operating panel and landing fixtures j) Steel ladder for lift machine room k) On / off switch for fan and light l) Over load warning indicator with audio announcer m)Voltage stabilizer for control circuits n)Braille button o) Pit ladder and Balustrade assembly 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries 40. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor.
41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department 42. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year. (SR)
Supply and fixing of 3 KVA single phase microprocessor controlled true online double conversion UPS system with builtin isolation transformer and power factor correction with necessary no. of batteries for 2 hour backup time along with suitable interlinks and ms powder coated battery rack with necessary accessories.
Supply and fixing of 5 KVA single phase microprocessor controlled true online double conversion UPS system with builtin isolation transformer and power factor correction with necessary no. of batteries for 2 hour backup time along with suitable interlinks and ms powder coated battery rack with necessary accessories.
Design, Supply Installation, testing and commissioning of 5.5 TRnominal capacity ceiling suspended Ductable Air conditioner with theFollowing components.a)5.5 TR capacity ceiling suspended Ductable Air Conditioner high tech,low height, low noise level indoor unitwith fin and tube type cooling coil,Detachable type drier provided inrefrigerant circuit to reduce moisturecontent multi stage type distributorfor feeding equal quantities of theRefrigerant mixture to all the section ofthe coil, with required valves, directlycoupled blower to reduce troubles andwear & tear compared to belt driveBlower. Thermostatic expansion valve arrangement, lift and pull type aluminium framed durable, washable air filter, Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45 F suction temperature Auto reset type HP/LP safety cut sensor type to improve Reliability of compressor. Type QTY- Ceiling Suspended Blower QTY – 1 Nos Motor Power – 415V /3Ph/50HZ Air flow -2200 CFM
B)5.5 TR capacity suitable for ceiling suspended Ductable Air conditioner high tech Outdoor unit with power saving high efficiency sturdy and rugged 1 No of scroll compressor each with inbuilt internal thermal protector, internal pressure relief valve, Auto reset type HP/LP safety cut sensor out to improve reliability of compressor andcondenser shall be made of super slithigh efficient aluminium fins mechanically bonded to copper tubescondenser ‘L’ type coil to be rigidlyfixed to unit frame with fastenersimported condenser fan & fan bladesto be statically and dynamicallybalanced to reduce noise andVibration. The fans are direct driven3phase motor with protection.Condensing temperature 130’f for thesystem operations. Refrigerant Compressor – Scroll No of Compressor – 1No Refrigerant – R22 Power supply – 415V/3Ph/50HZ No of Fan – 1Nos Types of Mounting – Rubber mounts with sleeve
Design, Supply Installation, testing and commissioning of 8.5 TRnominal capacity ceiling suspended Ductable Air conditioner with theFollowing components.a)8.5 TR capacity ceiling suspended Ductable Air Conditioner high tech,low height, low noise level indoor unitwith fin and tube type cooling coil,Detachable type drier provided inrefrigerant circuit to reduce moisturecontent multi stage type distributorfor feeding equal quantities of theRefrigerant mixture to all the section ofthe coil, with required valves, directlycoupled blower to reduce troubles andwear & tear compared to belt driveBlower. Thermostatic expansion valve arrangement, lift and pull type aluminium framed durable, washable air filter, Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45 F suction temperature Auto reset type HP/LP safety cut sensor type to improve Reliability of compressor. Type QTY- Ceiling Suspended Blower QTY – 1 Nos Motor Power – 415V /3Ph/50HZ Air flow -3400 CFM
B)8.5 TR capacity suitable for ceiling suspended Ductable Air conditioner high tech Outdoor unit with power saving high efficiency sturdy and rugged 1 No of scroll compressor each with inbuilt internal thermal protector, internal pressure relief valve, Auto reset type HP/LP safety cut sensor out to improve reliability of compressor andcondenser shall be made of super slithigh efficient aluminium fins mechanically bonded to copper tubescondenser ‘L’ type coil to be rigidlyfixed to unit frame with fastenersimported condenser fan & fan bladesto be statically and dynamicallybalanced to reduce noise andVibration. The fans are direct driven3phase motor with protection.Condensing temperature 130’f for thesystem operations. Refrigerant Compressor – Scroll No of Compressor – 1No Refrigerant – R22 Power supply – 415V/3Ph/50HZ No of Fan – 1Nos Types of Mounting – Rubber mounts with sleeve
Supply and filling of R-22 Refrigerant Gas.
Supply & fixing of hard drawn copper Refrigerant piping of suction line of Size 1 1/8” inches with necessary fitting and clamp etc.
Supply & fixing of hard drawn copper Refrigerant piping of liquid line of size 5/8” inches with necessary fitting and clamp etc...
Supply and fixing of flexible canvas connection between indoor unit and ducting and rubber pads, with ceiling Support angle rods etc.
Supply and fixing of suitable MS angle frame if required necessary catwalk / Base frame for mounting the outdoor units for protection from the rain water with dust flow on the open trace / corridor Floor area
Supply, Fabrication and Installation of GI Ducting arrangement with necessary angle supports, anchor fasteners and threaded rods etc. as required
Supply and Providing Thermal Insulation of 9mm thick –XLPE with aluminium foil./ Nitrile Rubber insulation
Supply and providing acoustic lining for initial portion of ducting with 10mm thick XLPE insulation.
Supply, fabrication and fixing of Volume control dampers individually across the duct
Supply and fixing of powder coated Extruded aluminium supply air grilles/diffuser with MS volume control damper for supply.
Supply and fixing of 1 inch PVC water drain pipe line on wall with suitable Clamp as required.
Towards charges for welding, leak testing, Nitrogen pressure testing, pressure holding, vaccummising, dehydration and other related works etc.
Supply and providing of pipeline nitral rubber insulation for section line Refrigerant pipe as required.
Supply & providing of Power supply for MCB to Outdoor unit with 4 core 10 sq.mm copper flexible cable
Supply & providing of control supply for Outdoor unit to Indoor unit HP and LP cut-outs with 6 core 2.5sq.mm copper flexible cable
GST at 18%
ABIRAMI ENGINEERING CONSTRUCTION AND CO
CMK Projects Private Ltd.,
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid