Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹24.5 L | L1 | Accepted-Finance L1 |
| 2 | L2₹27.1 L+₹2.5 L (10.3%)Accepted-Finance | ₹27.1 L+₹2.5 L (10.3%) | L2 | Accepted-Finance L2 |
| 3 | L3₹27.3 L+₹2.8 L (11.4%)Accepted-Finance | ₹27.3 L+₹2.8 L (11.4%) | L3 | Accepted-Finance L3 |
| 4 | L4₹27.6 L+₹3.1 L (12.4%)Accepted-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹27.6 L+₹3.1 L (12.4%) | L4 | Accepted-Finance L4 |
| 5 | L5₹27.7 L+₹3.2 L (13.0%)Accepted-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | ₹27.7 L+₹3.2 L (13.0%) | L5 | Accepted-Finance L5 |
| Sl No | Description | Qty | Unit | devan enterprises L4 | B5BUILDING SOLUTIONS L6 | RAHUL ENTERPRISES L5 | RAMSON TRADERS L2 | RAMESH BABU CO L7 | UNIVERSAL ENGINEERING L1 | M/S SRI BALAJI ENTERPRISES L8 | P Ramesh and Co L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for dismantling Air conditioner split/window type of capacity 1.5/2/3 TR from existing location including unsv copper tubing and other items and depositing to MES store yard for further disposal complete all as specified and directed. | 19 | Each | 650 ₹12,350 | 700 ₹13,300 | 650 ₹12,350 | 800 ₹15,200 | 1,000 ₹19,000 | 500 ₹9,500 Lowest | 700 ₹13,300 | 630 ₹11,970 |
| 2.00 | Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating As per BEE guidelines and ISEER Value 3.90 for air conditioner of capacity 1.5 TR including making core cutting complete all specified and directed. | 3 | Each Job | 61,500 ₹1,84,500 | 63,900 ₹1,91,700 | 62,800 ₹1,88,400 | 62,000 ₹1,86,000 | 64,500 ₹1,93,500 | 59,500 ₹1,78,500 Lowest | 63,000 ₹1,89,000 | 61,900 ₹1,85,700 |
| 3.00 | Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating As per BEE guidelines and ISEER Value 3.95 for air conditioner of capacity 2 TR including making core cutting complete all specified and directed. | 14 | Each Job | 74,000 ₹10,36,000 | 76,200 ₹10,66,800 | 74,250 ₹10,39,500 | 73,900 ₹10,34,600 Lowest | 75,600 ₹10,58,400 | 78,000 ₹10,92,000 | 78,000 ₹10,92,000 | 73,990 ₹10,35,860 |
| 4.00 | Supply, install, testing and commissioning hi wall invertor multi split units with two indoor unit and one outdoor unit with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating As per BEE guidelines and ISEER Value 3.95 for air conditioner of capacity 3.0 TR including making core cutting complete all specified and directed. | 2 | Each Job | 1,20,000 ₹2,40,000 | 1,23,000 ₹2,46,000 | 1,22,000 ₹2,44,000 | 1,19,000 ₹2,38,000 | 1,24,000 ₹2,48,000 | 68,000 ₹1,36,000 Lowest | 1,25,000 ₹2,50,000 | 1,18,900 ₹2,37,800 |
| 5.00 | Supply, install, testing and commissioning of invertor type ductable air conditioning system, of capacity minimum 5 TR, comprising of indoor and outdoor unit with invertor compressor of capacity minimum 5 TR capacity with R-410A Gas as refrigerant complete all as specified and directed with following items :-
(i) CPVC drain piping of size 32mm from indoor units till nearest drain points with necessary bends and fittings as per site requirement.
(ii) MS Stand for Outdoor ductable unit duly painted with two coats of red oxide over a coat of black synthetic enamel paint as per site requirement .
(iii) Cable of size 4Cx 2.5 Sqmm from outdoor unit to indoor unit as per recommendation of OEM as required at site.
(iv) Power cable of size 4C x 10 Sqmm from nearest power source to outdoor unit as per recommendation of OEM as required at site.
(v) Open and closed cell nitrile rubber for acoustic insulation of thickness 10mm for insulation of copper tubing from outdoor unit to indoor unit as per site requirements.
(vi) GI volume control dumper of suitable size as per recommendation of OEM and as required at site.
(vii) Grills with collar damper of suitable size as per recommendation of OEM as required at site.
(viii) Fire retardant flexible canvas connection as per recommendation of OEM and as required at site.
(ix) Installation of factory made GI Duct of size 24G/22G with angle flanges / support, joints, gasket, bolts & nuts etc compete all as per recommendation of OEM and approved by accepting officer .
Make : Blue Star/ Hitachi / Lloyd/LG. | 2 | Each Job | 4,75,000 ₹9,50,000 | 4,95,000 ₹9,90,000 | 4,88,000 ₹9,76,000 | 4,50,000 ₹9,00,000 | 5,10,000 ₹10,20,000 | 3,65,000 ₹7,30,000 Lowest | 5,10,000 ₹10,20,000 | 4,71,000 ₹9,42,000 |
| 5.10Note for Item No. 5: (i) Contractor has to submit the layout drawings of Ducts as per recommendation of OEM and get approval of same before commissioning of plant from Accepting officer. (ii) Contractor has to carryout nitrogen pressure test after commissioning of plant and has to submit the test report to EIC duly signed by rep of OEM. (iii) Necessary PCC Work required for fixing of stand including making holes in wall deemed to be included in quoted rate nothing extra will be paid to the contractor for this. (iv) Quoted deemed to be inclusive of complete dismantling of existing UNSV ductable air conditioner (indoor/ Outdoor Unit), transporting and depositing to MES store yard. | |||||||||||
| 6.00 | Supply and fix water cooler electric driven (single phase), 220V, 50Hz, having approx storage capacity 80 Litre and nominal cooling capacity 40 Litre per hour including making connection with RO/ main line including taking down old one and depositing in MES store yard for further disposal complete all as specified and directed.
Make: Usha/ Bluestar / Voltas | 1 | Each | 50,300 ₹50,300 | 48,000 ₹48,000 Lowest | 49,200 ₹49,200 | 48,700 ₹48,700 | 49,000 ₹49,000 | 48,900 ₹48,900 | 51,000 ₹51,000 | 48,800 ₹48,800 |
| 7.00 | Supply and fix water cooler electric driven (single phase), 220V, 50Hz, having approx storage capacity 120 Litre and nominal cooling capacity 60 Litre per hour including making connection with RO/ main line including taking down old one and depositing in MES store yard complete all as specified and directed.
Make: Usha/ Bluestar / Voltas | 1 | Each | 54,000 ₹54,000 | 53,000 ₹53,000 | 52,990 ₹52,990 | 51,250 ₹51,250 | 51,000 ₹51,000 Lowest | 63,000 ₹63,000 | 56,000 ₹56,000 | 51,200 ₹51,200 |
| 8.00 | Material and Labour for fabrication of base stand from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2/3 TR capacity Split AC complete all as specified and directed. | 12 | Each Job | 1,300 ₹15,600 | 1,240 ₹14,880 | 1,100 ₹13,200 Lowest | 1,320 ₹15,840 | 1,225 ₹14,700 | 1,250 ₹15,000 | 1,250 ₹15,000 | 1,190 ₹14,280 |
| 9.00 | Supply and fix PVC non-metallic flexible pipe of size 20mm dia along with fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed. | 30 | RM | 250 ₹7,500 | 260 ₹7,800 | 230 ₹6,900 | 240 ₹7,200 | 240 ₹7,200 | 255 ₹7,650 | 180 ₹5,400 Lowest | 260 ₹7,800 |
Tender Value
₹24.4 L
EMD Value
₹48,840
Closing Date
10 Jul 2026, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
SPECIAL REPAIRS AGAINST BER COOLING APPLIANCES AT AFS YELAHANKA
2026_MES_773436_1
8526/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF)Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹48,840
Yes
2 Sept 2026
19 Jun 2026
17 Jul 2026
19 Jun 2026
10 Jul 2026
3 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for dismantling Air conditioner split/window type of capacity 1.5/2/3 TR from existing location including unsv copper tubing and other items and depositing to MES store yard for further disposal complete all as specified and directed. | - | Each | 1 | - |
| 2 | Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating As per BEE guidelines and ISEER Value 3.90 for air conditioner of capacity 1.5 TR including making core cutting complete all specified and directed. | - | Each Job | 2 | - |
| 3 | Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating As per BEE guidelines and ISEER Value 3.95 for air conditioner of capacity 2 TR including making core cutting complete all specified and directed. | - | Each Job | 1 | - |
| 4 | Supply, install, testing and commissioning hi wall invertor multi split units with two indoor unit and one outdoor unit with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating As per BEE guidelines and ISEER Value 3.95 for air conditioner of capacity 3.0 TR including making core cutting complete all specified and directed. | - | Each Job | 1 | - |
| 5 | Supply, install, testing and commissioning of invertor type ductable air conditioning system, of capacity minimum 5 TR, comprising of indoor and outdoor unit with invertor compressor of capacity minimum 5 TR capacity with R-410A Gas as refrigerant complete all as specified and directed with following items :-
(i) CPVC drain piping of size 32mm from indoor units till nearest drain points with necessary bends and fittings as per site requirement.
(ii) MS Stand for Outdoor ductable unit duly painted with two coats of red oxide over a coat of black synthetic enamel paint as per site requirement .
(iii) Cable of size 4Cx 2.5 Sqmm from outdoor unit to indoor unit as per recommendation of OEM as required at site.
(iv) Power cable of size 4C x 10 Sqmm from nearest power source to outdoor unit as per recommendation of OEM as required at site.
(v) Open and closed cell nitrile rubber for acoustic insulation of thickness 10mm for insulation of copper tubing from outdoor unit to indoor unit as per site requirements.
(vi) GI volume control dumper of suitable size as per recommendation of OEM and as required at site.
(vii) Grills with collar damper of suitable size as per recommendation of OEM as required at site.
(viii) Fire retardant flexible canvas connection as per recommendation of OEM and as required at site.
(ix) Installation of factory made GI Duct of size 24G/22G with angle flanges / support, joints, gasket, bolts & nuts etc compete all as per recommendation of OEM and approved by accepting officer .
Make : Blue Star/ Hitachi / Lloyd/LG. | - | Each Job | 1 | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Binder1.pdf
Tender Documents • 0.36 MB
BOQ_866029.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .