Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹41.0 L+₹5.3 L (14.7%)Rejected-Finance 223 02 WARD NO 10 A DHURI DISTT SANGRUR | DHURI | SANGRUR | PUNJAB | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
23 Nov 2023, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
CERTAIN SPECIAL REPAIR REVENUE AND MINOR WORKS AT TRANSIT CAMP JAMMU AND NAGROTA UNDER GE NAGROTA
2023_MES_624489_1
GEN-8570/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAGROTA JAMMU
Class D Category b i
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹98,000
Yes
11 Mar 2024
21 Oct 2023
30 Nov 2023
21 Oct 2023
23 Nov 2023
6 Nov 2023
Amount
SCHEDULE A PART-I Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site. complete all as specified and directed.
Taking down chowaket & shutter exceeding 1.5 Sqm but not exc. 4 sqm each & removing from site complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided.complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises.complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc.complete all as specified and directed.
Solid PVC Door Frames of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F 75mm long butt hinges (medium weight) colled rolled mild steel .complete all as specified and directed.
S&F Extruded aluminium alloy handles fabricated type anodised of size 100mm long 12mm dia. complete all as specified and directed.
S&F 250mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.omplete all as specified and directed
S&F Aluminium anodized 150mm long barrel tower bolt of extruded section and fixed.complete all as specified and directed.
S & F Box type Steel ventilators top hung double shutters (inside for wiremesh & out side for glass), incl guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing. omplete all as specified and directed
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheetto be fitted in the MS frame welded/sealed to the styles and rails with suitablePVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawings omplete all as specified and directed.
S&F Galvanised mild steel wire cloth 0.457mm nominal dia of wire and average width of aperture 1.18mm dia and fixed with tinned tacks or galvanised mild steel staples
All as per item No 13 above but 4 mm thick figured glass
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement all as specified ( internally)
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement all as specified ( Externally)
M&L for Rendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement including three coat of white wash on ceiling including preparation of surface .
Supply only integral water proofing compound.omplete all as specified and directed
M&L for Applying two coats of synthetic enamel paint on new steel surfaces any description, not otherwise described over 10 cm width or girth omplete all as specified and directed
M&Lfor Two coat of white wash on newly /old plastered surface on wall including preparation of surface.complete all as specified and directed
Preparation of new plastered surfaces of ceiling and applying two coat of white washing,omplete all as specified and directed
M & L for Non-skid coloured tiles 400x400x7mm thick as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and incl 15 mm thick screed bed or beddding layer of CM 1:4 omplete all as specified and directed
M & L for 25mm thick PCC 1:2:4 type B-1 as a sub base to receive topping layer finished even and rough complete all as specified and directed
M&L 450x 300mm thick coloured glazed ceramic tiles as on walls/ vertical surfaces over 15mm cement rendering in cement mortar 1:4, including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ) , removing serviceable tile to store and rubbish off the premises.complete all as specified and directed
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded crushed stone agg as in any position .complete all as specified and directed
Taking down steel tubing and connection including cleaning removal to store bore of pipe 15mm bore complete all as specified and directed
Taking down steel tubing and connection including cleaning for refixing or removal to store bore of pipe 20mm bore complete all as specified and directed
S&F 15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down.complete all as specified and directed
S&F 20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors.
M&L for Cuttings chases for concealed water tubing of concealed conduit (cutting n.exc 10 cms girth) and making good in CM ( 1:3) in brick walls.complete all as specified and directed
S&F in repair Shower rose brass chrominium plated 125mm size.
S&F in repairs Cast copper alloy CP bib tap fancy type screwed down , screwed for iron pipe 15mm dia/ bore of pipe complete all as specified and directed
S&F in Brass CP mixer for mixing hot & cold water screwed down for iron pipe , screwed for iron pipe 15mm dia/ bore of pipe.complete all as specified and directed
S&F Cast copper alloy CPstop cock /angle Valve fancy type screwed both ends for iron pipe 15mm dia/ bore of pipe complete all as specified and directed
All as per item No 34 above but with long shank and cup ( concealed type) complete all as specified and directed
S&F Towel rail 600mm long of PTMT fixed with including chromium plated brass screws and wooden/plastic cleats ( Minimum weight 190gm).complete all as specified and directed
S&F Framed work rolled section as in framing compound girder staging for end bars, shouldered and riveted, forged into spikes, framed guard bars, dooriron, ladders walk rails, railings, frame work for tanks, water tank,cooler frame as and the like built up from two or more beam or channel section or angles with plates stiffeners etc complete all as specified and directed
Dismantling cast-iron/PVC pipes including fittings taking out of trenches or walls as required dia of pipe upto 100mm.complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore.complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 110mm bore.complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75mm bore.complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 75mm bore.complete all as specified and directed
S&F PVC (SWR) Bends any radius for 110mm bore.complete all as specified and directed
S&F PVC (SWR) Bends any radius for 75mm bore with oval access door.complete all as specified and directed
S&F PVC (SWR) Branch pieces single( Single Y) equal or unequal) for 110mm bore with oval access doors.complete all as specified and directed
S&F PVC (SWR) Branch pieces single ( Single Y) equal or unequal for 75mm bore with oval access doors.complete all as specified and directed
S&F PVC (SWR) vent cowl 75mm bore complete all as specified and directed
S&F PVC (SWR) floor trap with grating including jointing to waste pipe in solvent for 75mm bore including CP grating cover with or without hole complete all as specified and directed
S&F for PVC(SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified and directed
S&Fas in repair Vitreous china squatting pan "Orissa " pattern size 580x440mm white with integral foot rest all as fixed in repairs including ‘P’ or "S" trap including PVC low level cistern of 10 litres capacity including brackets jointing to flush pipe, PVC connection (450x15mm) flushing pipe complete fixed in repair all as directed by Engr-in-Charge.
S&F as in repair 110 mm PVC (SWR) WC Connector with lip ring complete all as specified and directed
M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm including bitumen primer @ 3.5Kg/Sqm complete all as specified and directed
M&L for Laying APP modified membrane 3mm thick and weighing not less than 3 kg/sqm with 160 GSM/sqm, non woven polyester mat as center core reinforcement, laid with 75 mm side over lap and 100mm end over lap, the membrane has to be laid with LPG tourch and over lap sealed and finished neat laid in Sunkon floor complete all as specified and directed
M&L for cement plaster of any description (sunken floor) apply a coat of cement slurry with 3.00 Kg of cement per sqm and Rendering 15mm thick in CM 1:3 using WPC finished even and smooth (sunken floor/wall)complete all as specified and directed ( wpc to be paid measured and seperately).
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size etc including taking down or and making good of disturbed surface all as specified below complete all as specified and directed. (a) Frame (top & side) section shall of size 101.60 x 44.75 x 2.4 mm ( Section No 14021) (b) Vertical Members of shutter Section shall be be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section shall be be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be be of 0.80 mm thick (Section No 19370).Make- Jinal Section,
S&F Anodised aluminium frame for door section/ window section/ ventilator section for side hung type shutter /sliding type shutter/fixed type shutter in two or more tracks, including automatic locking handle , rollers and roller plate & fitting arrangement complete all as all as specified and directed by Engineer-in-charge.(Glass pane , hydraulic door closer , plush plate, floor hinges shall be measured and paid separately.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed by Eng-in-charge.
S&F Sheet glass 4mm thick, ordinary quality and glazing fixed with aluminium section in squares not exceeding 0.5Sqm in each pane complete all as specified and directed.
S & Ffloor Door closer hydraulically regulated of Aluminium (Extruded section) body designation No.3, universe type, suitable for door shutters of 850 to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F pressed steel frame for door with two rebate incl necessary fixing lugs,hings,lock strike plate complete al as specified of size 105x60mm.
S&F 2nd class hard wood, 40 mm thick plain, framed panelled shutters (any number of panels) with panels of timber flat on both sides (Feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers, fitterd to chowkhats. complete all as specified and directed.
S&F 150mm long aluminium handles cast type, anodised and fitted.complete all as specified and directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.complete all as specified and directed
S&F 100mm mild steel butt hinges, medium weight, cold rolled and fixed.
M&L two coats of synathetic enamel paint over a coat of pink primer on new wood or wood surfaces, over 10 cms width or girth incl preparation of surfaces.complete all as specified and directed
Surface excavation n.exc 30cm deep and avg 15 cm deep and getting out any type of soil.complete all as specified and directed
Excavating in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n. exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil.
Returning filling in including spreading, levelling, watering and well ramming in layers n. exc 25 CM in any type of soil.complete all as specified and directed
Removing excavated meterial n exc 50 m and depositing where directed at a level n exc 1.5 m above starting point in soils complete all as specified and directed.
M&L Brick work with subclass 'B' old size bricks/ tiles straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 exc 6m mean radius.complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 12.5mm graded crushed stone aggregate as in copings, plinth course, damp proof course, bed blocks, benching, PCC cills and similar items.complete all as specified and directed.
M&L for PCC (1:3:6) Type C1 using 20mm graded stone agg as in surface channel & drain incl form work.complete all as specified and directed.
M&L Rendering 15 mm thick on other than fair faces of brick work, stone masonry or concrete surfaces in cement mortar 1:4 on wall surfaces, finishing the surface even and smooth with out using extra cement all as specified.
M&L Extra for forming fair finished drain or channel 25cm inner girth in cement concrete using extra cement including forms ,moulds,mitred/stopped ends etc complete all as specified and directed
M&L for Add or deduct Oon Srl item No 75 above for each 25mm girth over under 30 cm girth complete all as specified and directed
SCHEDULE A PART-II Taking down carefully unsv aluminium point wiring light/fan/socket or power complete and including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc) and removing material from site and making good to the disturbed surface matching with existing specification complete all as specified and directed
Taking down ceiling fan / Exhaust fan by disconnecting the electric connection and dismantling the blades and removing from ceiling of bldg by descrewing the nut bolt complete all as specified and directed
Rehanging and refixing ceiling fan/ exhaust fan and connecting up including provision of PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50Sqmm from ceiling rose or connector block of fan including minor repairs such as replacement of locking pin, reel insulators, bolts, nuts etc and spraying one coat of synthetic enamel paint of color approved by GE/ Engr in charge all as required and directed.
Taking down unserviceable Sheet metal box/ MCB DB SPN with MCB's of any make/ capacity as directed by Engr-in-charge.
Taking down unserviceable MCB DB TPN with MCB's of any make/ capacity as directed by Engr-in-charge
Taking down unserviceable sub main wiring including wooden batten/PVC conduit of any size, complete all as specified and directed by Engr-in-charge
Taking down unserviceable existing water heater, keeping aside safely & refixing the same to its original position after servicing of the whole geyser/ making functional and after completion of wiring work, complete all as specified and directed by Engr-in-charge. NOTE:- If any part found unserviceable during the refixing of water heater shall be measured and paid separetely under relavant item of schedule.
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly for one light/fan/bell point complete all as specified and directed.
All As per Srl item No 84 above but for one socket out let 5 Amp controlled by one switch on same board with other switch .
All As per Srl item N0 84 above for one socket out let 5 Amp controlled by one switch on independent board with other switch .
All As per Srl item No 84 above but for two, two way switchs
All as per item No 84 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS, PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board .
All as per item No 84 above but with 4 sqmm multi stranded copper conductor 1100 volts grade FR PVC insulated sheathed cable with FR PVC 4 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board .
M&L for switch piano flush button single pole one way 5 amps 230 volts complete all as specified and directed.
M&L for switch piano flush button type 2 way 5 amps 230 volts complete all as specified and directed.
M&L for socket 5 pin 2 in 1 multiporpose 5 Amps, flush type, 230 volts. complete all as specified and directed.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed.
M&L for Switch piano flush button single pole one way 15 amps 230 Volts complete all as specified and directed.
S&F ceiling rose , PVC/polycarbonate insulated body surface type 65mm dia three terminals single phase 230 volt complete all as specified and directed.
S&F Lamp holder/angle holder insulated body with back plate for batten fittings.complete all as specified and directed.
Supply and fix LED lamp 10 watts 230 volts retfrofit suitable for any type lamp holder as required. complete all as specified and directed.
S&F electronic fan regulator (socket or 2 module type) step type hum free heavy duty 230 volts suitable to control speed of fan from 0 to100% on existing laminated sheets complete all as specified complete all as specified and directed.
S & F LED tube light fitting 1 x 18 Watt prewired with all accessories Conf to Cat Pt No DMLN1LT8-16 of Crompton and including LED tube rod 18 Watt Cat Pt No LTT-20 or equivalent of make Bajaj/Philips inlcuding connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50Sqmm complete all as specified and directed.
S&F in replacement of any type fittings with LED Bulk Head luminaire comprises of pressure die cast housing acrylic diffuser & frame, having IP65 protection, energy efficient 10 Watt, complete with all accessories, internally pre wired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50Sqmm all as required at site complete all as specified and directed.. Make : Crompton conf to cat pt No LBHN-10-CDL or equivalent of make Bajaj /Phillips/Havells.
S&F baton integrated LED Channel of 10 Watt, 230 V, frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, PF not less than 0.9 complete all as specified and directed. Make as per Cat No. BCLSB 05WH of Bajaj or techno commercial equivalent in Phillips/Wipro/Havells
Supply & Fixing Exhaust fan 300 mm sweep PVC body single phase AC 230/240V complete with louvers for wall mounting incl grouting, holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core of suitable size from ceiling rose to exhaust fan incl cutting of hole complete all as specified and directed.. Make Venti Air-DB of Havelles or equivalent in Bajaj/Usha
S&F in replacement distribution board iron clad,double door with IP-43 protection suitable for MCCB as incomer and MCB as outgoing 415 Volts 3 phase 50 C/S 4 way, complete with approriate size copper busbar and neutral link complete with one MCCB 4 pole 415 Volts 125 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured and paid separetly)
S&F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps complete all as specified and as directed.
Supply & fix in replacement sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 12 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, conf to Cat Pt No 6077 11 of Legrand Ekinox3 or equivalent of make Hager/C&S/Schneider (Acti-9)/L&T (Exora)/Indoasian fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply & fix in replacement sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, conf to Cat Pt No 6077 11 of Legrand Ekinox3 or equivalent of make Hager/C&S/Schneider (Acti-9)/L&T (Exora)/Indoasian fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
Supply & fix in replacement sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, conf to Cat Pt No 6077 11 of Legrand Ekinox3 or equivalent of make Hager/C&S/Schneider (Acti-9)/L&T (Exora)/Indoasian fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
Supply and fix in replacement MCB SPN 240 volts, 40 to 63 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cables. complete all as specified and directed.
Supply and fix in replacement MCB SPN 240 volts, 6 to32 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cables. Make:- Hager/L&T EXORA/Schneider (Acti-9)/ Legrand/ Indoasian
Supply and fix in replacement MCB SP 240 volts, 6 to 32 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cablescomplete all as specified and directed. .
Supply and fix in replacement MCB SP 240 volts, 40 to 63 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cables. complete all as specified and directed.
Supply and fix in replacement MCB TPN 415 volts, 16 to 32 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cables. complete all as specified and directed.
Supply and fix in replacement MCB TPN 240 volts, 40 to 63 amps, with rupturing capacity 10 KA ` C' series, including providing thimble for out going cables. complete all as specified and directed.
Sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25 mm dia including one single core FR PVC insulated unsheathed 1100 volts grade cable with stranded copper conductoe of size 10 Sqmm as earth continuity conductor connected to common earth dolly complete Note:- 01x2 run of single core 10 Sqmm , 01 run of 10 sqmm earth dolly continuity conductor & 01 run PVC conduit strip shall be measured 01 unit for payment purpose.
Sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FR PVC insulated unsheathed 1100 volts grade cable with stranded copper conductoe of size 4 Sqmm as earth continuity conductor connected to common earth dolly complete Note:- 01x2 run of single core 4 Sqmm , 01 run of 4 sqmm earth dolly continuity conductor & 01 run PVC conduit strip shall be measured 01 unit for payment purpose.
S & F in replacement of heating element 1500 watt suitrable for 25 ltr electric water heater complete all as specified and directed.
S & F in replacement of thermostate suitrable for 25 ltr electric water heater complete all as specified.
S & F in replacement of pressure release valve suitrable for 25 ltr electric water heater complete all as specified and directed.
S & F in replacement of Hot water flexible PVC pipe suitrable for 25 ltr electric water heater complete all as specified and directed.
S & F in replacement of Cold water flexible PVC pipe suitrable for 25 ltr electric water heater complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion. complete all as specified and directed. NOTES : The earth pit shall be refilled by boulders free vegetable soil
S&F XLPE insulated screened PVC bedded , galvanised steel strip or wire armoured heavy duty 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core laid in trench/wall/pole through pipe including taking out of old UNSV cable of any size and all as specified and directed.
S&F XLPE insulated screened PVC bedded , galvanised steel strip or wire armoured heavy duty 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core laid in trench/wall/pole through pipe and all as specified and directed.
S&F XLPE insulated screened PVC bedded , galvanised steel strip or wire armoured heavy duty 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core laid in trench/wall/pole through pipe and all as specified and directed
Excavation in trenches in hard/dense soil not exc 1.5 Mtr wide & not exc 1.5 Mtr in depth for taking out unserviceable under ground cable including forming bottom surface complete all as specified and directed
Returing & filling in including spreading leveling watering & well ramming in layers not exc 25 cm thick in any type of soil.complete all as specified and directed.
Removals of excavated material to a distance not exc 50 mtr & depositing where directed at level not exc 1.5 mtr above the stating point in any type of soil complete all as specified and directed.
Supply & spreading in trenches with clean dry sand unwashed including gently punning around cable complete all as specified and directed
Supply & laying bricks common burnt clay building sub class`B' bricks laid in trenches for cable protection complete all as specified and directed
Supply and fixing 50 mm bore GI light grade steel tubing along the fittings and laid in trenches for protection of cable complete all as specified and directed.
Supply and fixing 40 mm bore GI light grade steel tubing along the fittings and laid in trenches for protection of cable complete all as specified and directed.
Supply and installtion chemincal dozing system W. pressure 10 Kg/Sqcm and discharge minimum 6 lph plunger type pump coupled with single / three phase 0.5 hp 1440 rpm motor with extended shaft for agitator through reduction gear complete with FRP solution tank inlet out let connections, ball valve and having liter marking on solution tank complete with starter and electrical connections etc. complete all as specified and directed.
S & F Modular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified and directed.
S & F Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specified and directed.
S & F Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified and directed.
S & F Modular white cover plate incl Modular base frame/boxes & powder coated Modular sheet metal concealed box for 4 module complete all as specified and directed.
All as per Item No-136 above but 3 module complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep heavy duty with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge.
Cutting out holes in existing cement concrete/bricks walls built in cement mortar making opening suitable for Exhaust fan 250/300mm sweep plastic body with louvers, grouting steel bolts for fixing with screwed end of suitable size complete all as specified and directed including making good the disturbed surface to match with the existing surface and finishes complete all as specified and directed.
M&L for Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 5 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
Supply and fixing aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
S & F Air termination, single pointed aluminium rod 12mm dia and 300mm long embeded in 60 mm thick PCC 1:2:4 type B-1 (20 mm graded stone aggregate) complete all as specified and directed by Engr-In-Charge.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
Material and labour for flame proof point wiring for one light point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade in and including stove enameled black, rigid steel conduits of size not less than 20 mm dia (Medium grade) fixed on surface of walls/ceilings as directed with all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size
S&F Switch flame proof rotray type with termination box in LM6, 16 A, Single pole 250 V complete all as specified and directed.
S&F SPN 4 Way FLP/WP lighting distribution panel Incoming - MCB 2P , 16 Amp /25 A -01 No Out going - MCB,1P ,6 Amp /10A -02 No with complete Internal Bus bar & wiring upto terminals complete all as specfied and directed.
Supply, laying and testing cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable ( Heavy duty) 1100 volt grade with stranded aluminium conductor of size 16 Sqmm 2 core and fixed alongwith wall with the help of saddles, clamp complete all as specified and directed.
M& L for Earthing complete with copper plate electrode 60cmx60cmx3.15mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to copper strip of size 20x3 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 5 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
Supply, laying,testing and commissioning of GI tubing medium grade ISI Marked with all fittings such as elbow, bends, sockets, nipples,Tee, and union etc complete laid in trenches for the 50 mm bore complete all as specified and directed by Engr-in-charge
Supply, laying,testing and commissioning of GI tubing medium grade ISI Marked with all fittings such as elbow, bends, sockets, nipples,Tee, and union etc complete laid in trenches for the 40 mm bore complete all as specified and directed.
Supply, laying and testing of GI tubing medium grade ISI Marked with all fittings such as elbow, bends, sockets, nipples,Tee, and union etc complete laid in trenches for the 25 mm bore complete all as specified and directed by Engr-in-charge
Supply, laying and testing of GI tubing medium grade ISI Marked with all fittings such as elbow, bends, sockets, nipples,Tee, and union etc complete laid in trenches/fixing to wall & ceilling on laid in floor for the 20 mm bore complete all as specified and directed by Engr-in-charge
Material and labour for Cutting of road upto to 1.5 depth meter for passing pipe lines through roads including re surfacing with PCC 1:3:6 of disturbed road surface complete all as specified and directed by Engr-in-charge.
Material and labour for cutting of existing CI/GI/DI 100 mm bore dia pipe and in position for inserting new Tee/Reducers/Branches etc all as specified and directed by Engr-in-charge Note:- Any cutting to the existing pipeline former connection will be made functional on the same day by the contractor with out fail .
S& F 25 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S& F 20 mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S& F 40 mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S& F cast iron heavy duty sluice valve of size 80 mm bore non rising type double flanged PN-1.6 confirming to IS -14846/2000 with brass spindle hand wheel with ISI marked including all necessary new rubber paking 6 mm thick nuts,bolts washers etc.complete all as specified and directed.
S& F cast iron of size 50 mm bore non rising type double flanged PN-1.6 confirming to IS -14846/2000 with brass spindle hand wheel with ISI marked including all necessary new rubber paking 6 mm thick nuts,bolts washers etc.complete all as specified and directed.
Material and labour for construction of brick masonary valve pit of size 600 x 600 x 600mm including excavation and earth work in any type of soil, PCC 1:4:8 (Type B2),in foundation brick work in CM 1:4, 15mm thick plaster in CM 1:4 flush pointing externally in same motar as the work process angle iron frame 40X40X6mm with 3.0 mm thick MS sheet cover with hinges ,12mm dia handle and locking arrangements(including lock and two keys )and two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
Material and labour for construction of brick masonary valve pit of size 900 x 900 x 900mm including excavation and earth work in any type of soil, PCC 1:4:8 (Type B2),in foundation brick work in CM 1:4, 15mm thick plaster in CM 1:4 flush pointing externally in same motar as the work process angle iron frame 40X40X6mm with 3.0 mm thick MS sheet cover with hinges ,12mm dia handle and locking arrangements(including lock and two keys )and two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
Supply, Installation, connecting, testing and commissioning of Desert Cooler steel body nominal capacity of air 4000 Cum / hours having 500 mm fan size with submersible water lifting pump and connected with accessories etc and necessary water connection to the cooler with GI pipe 15mm dia medium grade with fittings including stop cock brass 01 No, PVC connection etc. complete all as specified and directed. Make Symphony/BlueStar/Khaitan
M& L for framed work such as angle iron stand of desert cooler with ends of bars / angle iron shouldered/ riveted / forged into spikes / welded including two coats of synthetic enamel paint over a coat of red oxide primer and all as directed .
Supply and Fix water cooler electric driven (Single phase), partially stainless steel having approximate storage capacity of 150 Ltrs and nominal cooling capacity of 150 Ltrs /Hrs including all accessories complete all as specified and directed.
S&F stop valves for bore dia 15 mm of pipe, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle.screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed.
Cutting and screwing existing G.I tubing of 15/20 mm for alterations or additions on pipe for coonectors (Each cut measured) complete all as specified and directed.
S&F Tubes 15 mm 'medium grade' galvanised with all fitting (i.e. Tee, socket, bend etd) complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply,installation,connecting, testing & commissioning Split AC 1.5 Ton capacity , reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed Make : Hitachi/Ogeneral/Voltas (Note :- A.C. Should be minimum 3 star rated under BEE Label) .
S&F Voltage stabilizer 4 KVA, input voltage range 90 volt to 280volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage complete with accessories etc complete all as specified and directed..
SHARMA CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .