Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.4 L+₹1.9 L (6.65%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L2 | Rejected-Finance Bidder Not Lowest | |
| 3 | L3₹36.1 L+₹7.5 L (26.3%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance Bidder Not Lowest | |
| 4 | L4₹36.7 L+₹8.2 L (28.6%)Rejected-Finance | L4 | Rejected-Finance Bidder Not Lowest | |
| 5 | L5₹37.6 L+₹9.0 L (31.6%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance Bidder Not Lowest |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
1 Feb 2021, 6:00 pmClosed
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
REPAIR REPLACEMENT OF SUBMAIN WIRING DBS INCLUDING MCBS AND LED LIGHT FITTINGS IN COMMON AREAS OF AGE BR III UNDER GE WEST DELHI CANTT 10
2021_MES_409230_1
GE/DW-78/2020-21
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹99,000
9 Feb 2021
4 Jan 2021
3 Feb 2021
4 Jan 2021
1 Feb 2021
19 Jan 2021
Amount
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power) complete (fittings such as switches, ceiling roses, holders, sockets, light fittings) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed.
M&L for point wiring with 3 x1.5 sqmm (nominal area) FRLS PVC insulated unsheathed copper conductor cable ( phase, neutral and earth wire ) in and including PVC concealed conduit ISI marked of suitable size medium grade with PVC conduit fittings such as tees,bends, elbow,redcers including cutting chasing and making good to the disturbed surface as per existing, earth wire connected to comman earth dolly with and including pressed steel sheet metal sunken box of suitable size for fixing switches/ sockets etc with cover plate 3 mm thick plastic laminated sheet for one light /fan /exhaust fan/ circulator fan/ bell /buzzer controlled by one way switch complete all as specified and directed :
(a) One light/fan/bell point controlled by one way switch 5 amps.
S&F in repair Double pole MCB 40 amp, 240 v, 50 Hz, AC, Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed.
S&F Single pole MCB 6 to 32 amp, 240 v, 50 Hz, AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed.
S&F Surface mounting 10 watt LED tube light fitting of 2 ft length complete all as specified and directed.
S&F Surface mounted, decorative oval bulk head LED 10 Watt luminaire comprising of high brightness LEDs complete all as specified and directed.
S&F New generation energy saving and environmental friendly long life LED street light made up 25 watt LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection complete all as specified and directed.
S&F surface mounting 20 watt LED tube light fitting of 4 ft length 230 Volt,50Hz complete all as specified and directed.
S&F in repair factory made epoxy polyester powder coated distribution board SP&N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings and conforming to IS: 8623 alongwith cable end box for above DB complete all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
Supply, laying and drawing in existing concealed PVC rigid conduit on walls 03 runs of IC x 6.00 sqmm (Main, neutral and earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring complete all as specified and directed. Note: Contracror quoted rates shall include complete T&P including necessary form work, scoffolding and safety measures for approximate height 25 to 30 mtr of the high rise multistories building, nothing extra shall be admissible on this account.
S&F hot press moulded SMC meter box of inside dimensions 250x150x155mm with hinged doors with new plywood size (500x450x10)mm fixed to wall including taking down electric meter from main panel and refix in meter box complete all as specified and directed. Make: Sintex or equivalent
S&F in repair factory made epoxy polyster powder coated distribution board, SP two way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to plywood complete all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
Supply & Fixing factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates suitable for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs complete all as specified and directed. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F MCCB 100 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F in repair of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 433650.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
M/s Krishna Construction Co.
M/s Adhikari construction co.
jain associates
M/S ANIL KUMAR
SETHI ENTERPRISES
SANJEEV ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .