Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-Finance PLOT NO 9 INFRONT OF PROJECT GATE NEAR HOTEL TRIMURTI NIMBLORA BK DEEPNAGAR TAL BHUSAWAL JALGAON 425307 | JALGAON | JALGAON | MAHARASHTRA | 425307 | ₹9.9 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹9.9 L+₹919.90 (0.09%)Accepted-Finance | ₹9.9 L+₹919.90 (0.09%) | L2 | Accepted-Finance Being L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not complied PQR 5b |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not complied PQR 5b |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not complied PQR 5b |
| Sl No | Description | Qty | Unit | SANROZ TECHNOLOGIES L1 | TRIZTECH SYSTEM L2 |
|---|---|---|---|---|---|
| 1.00Repairing and Application of Chemical Resistant Coating for Degasser water Storage Tank internal area 8.630 mtr.x 8.630mtr.x 3.5mtr. With application of Chemical resistance coating technically as under. | |||||
| 1.01 | (A) For primer:
(i) Good chemical resistance against exposure to Acidic water Ph value approx 3 to 4.
(ii) Maximum application Temp shall be 150 Degree centigrade.
(iii) Good Abrasion resistance.
(B) Acid Resistant Epoxy Coating
(i)MonoGuard CCR- SPC25 Concentrated Sulfuric Acid Resistant Novolac Epoxy Coating and equivalent.
(ii) Density as per ASTM D 1475 approx 1.54 Gm/cc.
(iii)Pot life as per ASTM D 2471 time Min 40 min.
(iv)Recoat Time @25 C as per IS101 time approx HRS 5-6.
(v)Tensile Strength, as per ASTMD 638 minimum 6500 PSI.
(vi) Compressive strength as per ASTM D 695 minimum 10500 Psi.
(vii) Hardness, Shore D as per ASTM D 2240 Shore D Minimum 80-85.
(viii) Bond Strength as per ASTM D 4547 minimum 10 N/MM2.
(ix) Coverage area as per ASTM D 4303 Sq.m/ kg minimum @ 400 mic at 2 Coats.
(x) Dry film thickness shall be minimum 400 microns per coat. | 195 | Sq. Mtrs. | 8,37,525 ₹9,88,279.5 Lowest | 8,38,305 ₹9,89,199.9 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
12 Aug 2026, 5:00 pmClosed
SE (PNW)
O/o CE(GEN) STPS
Work for repairing and Application of Chemical Resistant Coating to Degasser water Storage Tank installed at DM Plant PH-IV, STPS, Sarni.
2026_MPPGC_526195_1
WT-5227
Open Tender
Miscellaneous Works
Item Rate
10 days
sarni
as per NIT
7 documents required · 7 mandatory
₹500
Yes
₹19,800
Yes
21 Aug 2026
1 Aug 2026
13 Aug 2026
1 Aug 2026
12 Aug 2026
1 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Repairing and Application of Chemical Resistant Coating for Degasser water Storage Tank internal area 8.630 mtr.x 8.630mtr.x 3.5mtr. With application of Chemical resistance coating technically as under. | |||||
| 1.01 | (A) For primer:
(i) Good chemical resistance against exposure to Acidic water Ph value approx 3 to 4.
(ii) Maximum application Temp shall be 150 Degree centigrade.
(iii) Good Abrasion resistance.
(B) Acid Resistant Epoxy Coating
(i)MonoGuard CCR- SPC25 Concentrated Sulfuric Acid Resistant Novolac Epoxy Coating and equivalent.
(ii) Density as per ASTM D 1475 approx 1.54 Gm/cc.
(iii)Pot life as per ASTM D 2471 time Min 40 min.
(iv)Recoat Time @25 C as per IS101 time approx HRS 5-6.
(v)Tensile Strength, as per ASTMD 638 minimum 6500 PSI.
(vi) Compressive strength as per ASTM D 695 minimum 10500 Psi.
(vii) Hardness, Shore D as per ASTM D 2240 Shore D Minimum 80-85.
(viii) Bond Strength as per ASTM D 4547 minimum 10 N/MM2.
(ix) Coverage area as per ASTM D 4303 Sq.m/ kg minimum @ 400 mic at 2 Coats.
(x) Dry film thickness shall be minimum 400 microns per coat. | 195 | Sq. Mtrs. | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.09 MB
Annexures5227.pdf
Tender Documents • 2.03 MB
Technocommercialbid5227.xls
Tender Documents • 0.32 MB
Schedule5227.pdf
Tender Documents • 0.50 MB
SBDAMENDED.pdf
Tender Documents • 5.86 MB
BOQ_633456.xls
BOQ • 0.26 MB
corr2ndWT5227.pdf
PDF • 0.31 MB
corr1stWT5227.pdf
PDF • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .