Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.9 L+₹1.9 L (9.92%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹21.0 L+₹2.0 L (10.3%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹22.4 L+₹3.4 L (17.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹22.8 L+₹3.8 L (20.1%)Rejected-Finance NEAR R K HOTEL DISTRICT POONCH J K PIN 185101 | POONCH | POONCH | JAMMU AND KASHMIR | 185101 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
10 Oct 2024, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
SPL REPAIR TO MULE SHED BLDG NO P-82 AT POONCH AND PROVN OF HARD STANDING AT MT AREA AT MENDHAR UNDER GE 881 EWS
2024_MES_674485_1
GE/PNH-42/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹58,000
Yes
29 Oct 2024
13 Sept 2024
12 Oct 2024
13 Sept 2024
10 Oct 2024
26 Sept 2024
Amount
B&R PORTION:- Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc., complete all as specified and directed.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete of any description not otherwise specifically provided for, complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:3 on concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M & L for plain cement concrete 1:3:6 type C-1, using 20mm graded crushed stone aggregates as in surfaces channels and drain complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement including forms, moulds mitred/stopped ends etc. complete all as specified and directed.
M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, complete all as specified and directed.
M&L for applying metallic floor hardner @ 5 % by weight of cement in top layer of flooring, complete all as specified and directed.
Forming 12mm thick expansion joint and filled with performed bituminous filler and top 30mm primed & sealed with sealing compound grade 'A' complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete 15mm thick screed bed in CM 1:6, complete all as specified and as directed.
M&L for glazed ceramic coloured tiles (450x350mm) x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4, complete all as specified and directed by Engr-In-Charge.
M&L for 75mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for preparation of old plastered/ un-plastered wall surfaces and applying two coats of cement base paint, complete all as specified and directed.
M&L for preparation of old plastered/ un-plastered wall surfaces , and applying three coats of white wash on walls including cornices, pilasters etc, complete all as specified and directed.
M&L for preparation of old plastered/ un-plastered ceiling surfacess, and applying two coats of white wash, complete all as specified and directed.
M&L for Steel pipe for the purpose of hanging of salt for mules including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated Eaves gutter and pipes any description, not exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc.), complete all as specified and as directed.
M&L for 10 mm thick terrazzo topping with 4 to 7 mm size marble aggregate with grey cement and no pigment including grinding and polishing in floors, complete all as specified and directed.
Taking up or down steel tubing of 20 mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed.
S&F in repair 20mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe complete all as specified and directed.
S&F GI tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and directed.
Surface excavation not exceeding 30cm deep and average 15cm deep and getting out in any type of soil, complete all as specified and directed.
M&L for hard core filling under floor, of broken stone or boulder gauge exceeding 63mm and not exceeding 100mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rolled rammed to a true surface , complete all as specified and directed.
M&L for 150mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc. finished even & fair, complete all as specified and directed.
M&L for sand filling under floors or in foundation including required watering and consolidation complete all as specified and directed
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80 mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments, complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE.
M & L for plain cement concrete 1:2:4 type B-1, (using 20mm graded stone aggregates) as in bed block, coping, benching and similar work including necessary form work complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50m and deposition where dircted at a level not exceeding 1.50m above the starting point, all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
All as per srl item No 35 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin, 6 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 5 and 15 Amp flush type universal, complete all as specified and directed.
S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
S&F in repair LED inverter lamp CDL 12 watt with holder base (B22) type, complete all as specified and directed.
Supply and fixing in repair inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells cat part No. LHEXACP7FN1W020 or equivalent make as specified in PS
Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 4 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
S&F Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F in repair Sub main wiring with single core cable 2x 4 Sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, complete all as specified and directed. Note:-Three wire of 4 sqmm and one run of PVC conduit/casing caping shall be measured as one unit.
S&F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 2 core, complete all as specified and directed.
SUNIL KUMAR SANGEET KUMAR AND SONS (BID ID -3135035)
NATIONAL TRADING COMPANY (BID ID -3135138)
M/S SEVEN LAKE CONSTRUCTION (BID ID -3135073)
M/S RAJINDER KUMAR (BID ID -3126514)
M/S BADRI NATH GUPTA (BID ID -3116964)
M/S BHATT TRADERS (BID ID -3126878)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .