| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 CrAdmitted-Finance | ₹1.4 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected as per PQC |
| Sl No | Description | Qty | Unit | REMAG ELECTROS PVT. LTD. L1 | VIJAY ENGINEERING WORKS L2 |
|---|---|---|---|---|---|
| 1.10 | Complete rewinding of 6.6 KV B.F.P. Motor Stator (3500KW, 54 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs | 1 | Nos | 10,58,805 ₹10.6 L | 10,25,000 ₹10.3 L |
| 1.20 | Complete reinsulation of 6.6 KV B.F.P. Motor Stator (3500KW, 54 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs | 1 | Nos | 4,68,615 ₹4.7 L | 4,60,000 ₹4.6 L |
| 1.30 | Stator core re-staggering | 1 | Nos | 41,461 ₹41,461 | 40,000 ₹40,000 |
| 1.40 | Rate of new coil with fresh copper and class-F insulation for one coil only | 1 | Nos | 1,675 ₹1,675 | 15,000 ₹15,000 |
| 2.10 | Complete rewinding of 6.6 KV I.D. Fan Motor Stator (1700KW, 72 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs | 1 | Nos | 6,47,600 ₹6.5 L | 6,35,000 ₹6.3 L |
| 2.20 | Complete reinsulation of 6.6 KV I.D. Fan Motor Stator (1700KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs | 1 | Nos | 3,67,500 ₹3.7 L | 3,67,000 ₹3.7 L |
| 2.30 | Stator core re-staggering | 1 | Nos | 39,506 ₹39,506 | 39,500 ₹39,500 |
| 2.40 | Rate of new coil with fresh copper and class-F insulation for one coil only | 1 | Nos | 7,245 ₹7,245 | 7,970 ₹7,970 |
| 3.10 | Complete rewinding of 6.6 KV P.A. Fan Motor Stator (1250KW, 72 Coils)with fresh copper and class 'F' insulation & replacement of all RTD | 1 | Nos | 7,47,500 ₹7.5 L | 7,35,000 ₹7.3 L |
| 3.20 | Complete reinsulation of 6.6 KV P.A. Fan Motor Stator (1250KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs | 1 | Nos | 3,53,671 ₹3.5 L | 3,53,600 ₹3.5 L |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
20 Nov 2025, 4:00 pmClosed
Superintending Engineer OMC IV BTPS Obra
Office of Superintending Engineer OMC IV BTPS Obra
Rewinding of 6.6 KV HT Motors of 5x200 MW Units BTPS Obra For Six Months
2025_RVUNL_1088358_1
OBR/B/OMC4/EMD3/6000009871_00
Open Tender
Electrical Works
180 days
OBRA THERMAL POWER PLANT
AS PER PQC
3 documents required · 3 mandatory
₹1,180
Dy. CAO CFA and BO BTPS OBRA
₹60,000
3 Jan 2026
6 Nov 2025
22 Nov 2025
6 Nov 2025
20 Nov 2025
6 Nov 2025
Amount
Complete rewinding of 6.6 KV B.F.P. Motor Stator (3500KW, 54 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation of 6.6 KV B.F.P. Motor Stator (3500KW, 54 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV I.D. Fan Motor Stator (1700KW, 72 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation of 6.6 KV I.D. Fan Motor Stator (1700KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV P.A. Fan Motor Stator (1250KW, 72 Coils)with fresh copper and class 'F' insulation & replacement of all RTD
Complete reinsulation of 6.6 KV P.A. Fan Motor Stator (1250KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV F.D. Fan Motor Stator (630KW, 90 Coils) with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulationof 6.6 KV F.D. Fan Motor Stator (630KW, 90 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV C.W. Pump Motor Stator (450KW, 108 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation6.6 KV C.W. Pump Motor Stator (450KW, 108 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV Bowl Mill Motor Stator (340KW, 72 Coils) with fresh copper and class 'F' insulation & replacement of all RTD
Complete reinsulation of 6.6 KV Bowl Mill Motor Stator (340KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV H.P. Ash Water Pump Motor Stator (262KW, 60 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation 6.6 KV H.P. Ash Water Pump Motor Stator (262KW, 60 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV C.E.P. Motor Stator (220KW, 48 Coils) with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation of 6.6 KV C.E.P. Motor Stator (220KW, 48 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV S.O.P. Motor Stator (200KW, 90 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation of 6.6 KV S.O.P. Motor Stator (200KW, 90 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV E.F.P./H.P. Fire Pump Motor Stator (168KW, 48 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulationof 6.6 KV E.F.P./H.P. Fire Pump Motor Stator (168KW, 48 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Checking run out/ ovality of shaft journal portion, under cutting, welding, machining and dynamic balancing of following rotors, under cutting, welding and machining work done no. H.P ash, cw pump and CEP / SOP motors if required: B.F.P./I.D. fan motor/ rotor
Checking run out/ ovality of shaft journal portion, under cutting, welding, machining and dynamic balancing of following rotors, under cutting, welding and machining work done no. H.P ash, cw pump and CEP / SOP motors if required: PA/FD fan motor / rotor
Checking run out/ ovality of shaft journal portion, under cutting, welding, machining and dynamic balancing of following rotors, under cutting, welding and machining work done no. H.P ash, cw pump and CEP / SOP motors if required: HP Ash water pump motor/CW pump motor
Checking run out/ ovality of shaft journal portion, under cutting, welding, machining and dynamic balancing of following rotors, under cutting, welding and machining work done no. H.P ash, cw pump and CEP / SOP motors if required: CEP / SOP motor / rotor
Reclaimation of shaft journal portion dia, both side of rotor shaft by under cutting, welding with suitable electrodes, machining & heat treatment with stress relieving, removal of runout & ovality at shaft journal and shaft coupling portion, chrome polishing on shaft journal portion and dynamic balancing of following 6.6KV H.T. Motor Rotor as per scope of work:B.F.P. Motor Rotor (3500KW), Journal portion dia should be strictly 160mm.
Reclaimation of shaft journal portion dia, both side of rotor shaft by under cutting, welding with suitable electrodes, machining & heat treatment with stress relieving, removal of runout & ovality at shaft journal and shaft coupling portion, chrome polishing on shaft journal portion and dynamic balancing of following 6.6KV H.T. Motor Rotor as per scope of work: I.D. Fan Motor Rotor (1700KW), Journal portion dia should be strictly 180mm
Reclaimation of shaft journal portion dia, both side of rotor shaft by under cutting, welding with suitable electrodes, machining & heat treatment with stress relieving, removal of runout & ovality at shaft journal and shaft coupling portion, chrome polishing on shaft journal portion and dynamic balancing of following 6.6KV H.T. Motor Rotor as per scope of work:P.A. Fan Motor Rotor (1250KW), Journal portion dia should be strictly 140mm
Reclaimation of shaft journal portion dia, both side of rotor shaft by under cutting, welding with suitable electrodes, machining & heat treatment with stress relieving, removal of runout & ovality at shaft journal and shaft coupling portion, chrome polishing on shaft journal portion and dynamic balancing of following 6.6KV H.T. Motor Rotor as per scope of work: F.D. Fan Motor Rotor (630KW), Journal portion dia should be strictly 140mm
Reclaimation of shaft journal portion dia, both side of rotor shaft by under cutting, welding with suitable electrodes, machining & heat treatment with stress relieving, removal of runout & ovality at shaft journal and shaft coupling portion, chrome polishing on shaft journal portion and dynamic balancing of following 6.6KV H.T. Motor Rotor as per scope of work: CEP Motor Rotor (220KW)/HP Ash Water Pump Motor Rotor (262KW)/other motor rotor upto 450KW. Bearing portion of CEP & HP Ash Water Pump Rotor should be strictly 110mm+.05mm.
Complete replacement of rotor bar with new set of bars, re-caging, checking run out/ ovality, dynamic balancing and re-metalling of rotor of B.F.P. Motor (6.6KV, 3500 KW) as per Scope of work.
Repair of core by re-staggering
Complete replacement of rotor bar with new set of bars, re-caging, checking run out/ ovality, dynamic balancing and re-metalling of rotor of PA fan Motor (6.6KV, 1250 KW) as per Scope of work.
Repair of core by re-staggering
VIJAY ENGINEERING WORKS (BID ID -5686222)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.02 MB
TSD.pdf
Tender Documents • 0.17 MB
BOQ_1996706.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid