Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-Finance | ₹30.2 L | L1 | Accepted-Finance L1 Bidder |
| 2 | L2₹34.0 LRejected-Finance | ₹34.0 L | L2 | Rejected-Finance Not L1 Bidder |
| 3 | L3₹35.4 LRejected-Finance HIMACHAL BUILDING SHOP NO 10 CD BARFYWALA ROAD JUHU LANE ANDHERI W MUMBAI 400058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹35.4 L | L3 | Rejected-Finance Not L1 Bidder |
| 4 | L4₹36.0 LRejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹36.0 L | L4 | Rejected-Finance Not L1 Bidder |
| 5 | L5₹36.3 LRejected-Finance | ₹36.3 L | L5 | Rejected-Finance Not L1 Bidder |
| Sl No | Description | Qty | Unit | Tejas Enterprises L5 | Shree Ayyappa Engineering L4 | NAGESHWAR ELECTRICALS L1 | Shining Star Electricals L6 | SHAILENDRA B TULSANI L7 | M/s PIONEER CONTRACTORS L3 | M/S VEDHANT ASSOCIATES L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavatioin in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /erection of pole/stay pit excavation | 248 | CUM | 300 ₹74,400 | 290 ₹71,920 | 190 ₹47,120 | 250 ₹62,000 | 350 ₹86,800 | 300 ₹74,400 | 270 ₹66,960 |
| 2.00 | M & L for Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth getting out for the pole foundation/cable in Hard/dense soil complete all as specified and directed by Engineer-in-Charge. | 59.25 | CUM | 450 ₹26,662.50 | 450 ₹26,662.50 | 240 ₹14,220 | 250 ₹14,812.50 | 430 ₹25,477.50 | 504 ₹29,862 | 270 ₹15,997.50 |
| 3.00 | M & L for Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth getting out for the pole foundation/cable in Hard rock complete all as specified and directed by Engineer-in-Charge. | 141.75 | CUM | 700 ₹99,225 | 500 ₹70,875 | 675 ₹95,681.25 | 300 ₹42,525 | 1,850 ₹2.6 L | 540 ₹76,545 | 450 ₹63,787.50 |
| 4.00 | M & L for Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm in thick all as specified and directed by Engineer-in-Charge. | 172.1 | CUM | 90 ₹15,489 | 30 ₹5,163 | 60 ₹10,326 | 150 ₹25,815 | 100 ₹17,210 | 99 ₹17,037.90 | 90 ₹15,489 |
| 5.00 | M & L for Removing excavated material to a distance not exc 50 mtr and depositing where directed by Engineer-in-Charge at a level n exc 1.5 m above the starting point complete all as specified by the Engineer-in-charge. | 341.65 | CUM | 90 ₹30,748.50 | 30 ₹10,249.50 | 120 ₹40,998 | 150 ₹51,247.50 | 150 ₹51,247.50 | 135 ₹46,122.75 | 95 ₹32,456.75 |
| 6.00 | M & L for Cutting the existing PCC floor/road/foot path not exeeding 15cm width,30 cm depth for laying of UG cable/protection of pipe all as directed by Engineer-in-Charge. | 12 | RM | 450 ₹5,400 | 200 ₹2,400 | 550 ₹6,600 | 1,200 ₹14,400 | 450 ₹5,400 | 108 ₹1,296 | 300 ₹3,600 |
| 7.00 | M & L for PCC type B1,1:2:4 using 20 mm graded stone aggregate all as specified and directed by Engineer-in-Charge. | 0.54 | CUM | 5,000 ₹2,700 | 3,500 ₹1,890 | 4,200 ₹2,268 | 7,000 ₹3,780 | 6,500 ₹3,510 | 4,500 ₹2,430 | 2,500 ₹1,350 |
| 8.00 | Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as directed by Engineer-in-Charge. | 600 | RM | 712 ₹4.3 L | 790 ₹4.7 L | 584 ₹3.5 L | 550 ₹3.3 L | 960 ₹5.8 L | 702 ₹4.2 L | 600 ₹3.6 L |
| 9.00 | All as per item No 8 here-in-before but for 70 sqmm 3 1/2 core | 600 | RM | 569 ₹3.4 L | 630 ₹3.8 L | 458 ₹2.7 L | 450 ₹2.7 L | 758 ₹4.5 L | 551.7 ₹3.3 L | 475 ₹2.9 L |
| 10.00 | All as per item No 8 here-in-before Same as above but for 50 sqmm 3 1/2 core | 550 | RM | 420 ₹2.3 L | 430 ₹2.4 L | 346 ₹1.9 L | 400 ₹2.2 L | 445 ₹2.4 L | 414 ₹2.3 L | 350 ₹1.9 L |
Updated dates
Tender Value
₹39.3 L
EMD Value
₹78,600
Closing Date
13 Apr 2026, 6:00 pmClosed
Gaurav Tiwari, IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
PROVN OF PERIMETER LIGHTS AND ASSOCIATED STAND BY POWER SUPPLY THROUGH DG SET BEHIND KV AND REPLACEMENT OF 3-PHASE LT CABLE FROM OTC GATE TO KALI MATAT GATE AT INS SHIVAJI LONAVLA
2026_MES_755497_1
GE/LONAVLA/8421/E8
Open Tender
Civil Works
120 days
GE (I) (NAVY) LONAVLA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (I) (NAVY) LONAVLA
₹78,600
Yes
8 May 2026
14 Mar 2026
15 Apr 2026
14 Mar 2026
13 Apr 2026
30 Mar 2026
14 Mar 2026 - 28 Mar 2026
Excavatioin in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /erection of pole/stay pit excavation
M & L for Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth getting out for the pole foundation/cable in Hard/dense soil complete all as specified and directed by Engineer-in-Charge.
M & L for Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth getting out for the pole foundation/cable in Hard rock complete all as specified and directed by Engineer-in-Charge.
M & L for Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm in thick all as specified and directed by Engineer-in-Charge.
M & L for Removing excavated material to a distance not exc 50 mtr and depositing where directed by Engineer-in-Charge at a level n exc 1.5 m above the starting point complete all as specified by the Engineer-in-charge.
M & L for Cutting the existing PCC floor/road/foot path not exeeding 15cm width,30 cm depth for laying of UG cable/protection of pipe all as directed by Engineer-in-Charge.
M & L for PCC type B1,1:2:4 using 20 mm graded stone aggregate all as specified and directed by Engineer-in-Charge.
Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as directed by Engineer-in-Charge.
All as per item No 8 here-in-before but for 70 sqmm 3 1/2 core
All as per item No 8 here-in-before Same as above but for 50 sqmm 3 1/2 core
All as per item No 8 here-in-before Same as above but for 35 sqmm 3 1/2 core
All as per item No 8 here-in-beforeSame as above but for 25 sqmm 3 1/2 core
All as per item No 8 here-in-beforeSame as above but for 16 sqmm 4 core
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable size 4 core ,35 Sqmm cross sectional area with aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts including testing complete note- rate is inclusive of cable gland & cable lugs Note -Excavation and earth work shall be measured and paid for separately under relevant item of schedule.
Laying of LT 1.1 kV grade XLPE insulated, PVC sheathed, armoured aluminium/copper conductor power cables of different sizes in ground / ducts including drawing the cables through 63 X 50mm DWC pipes, as specified and directed by Engineer-in-Charge. The work also includes laying, fixing and neatly saddling the said cables in approved size DWC pipes on walls / ceilings / columns with suitable MS saddles, clamps, nuts, bolts, spacers and rawl plugs at required intervals, including all labour, tools, tackles and materials necessary to complete the work in all respects. All DWC pipe joints shall be made using manufacturer-approved couplers, ensuring smooth internal bore, proper alignment, and continuous unobstructed duct for easy cable pulling, replacement and future provision. Couplers shall be fixed securely as per specifications and as directed by Engineer-in-Charge.
M&L Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mm dia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-1991 (part-I)
M& L for Earthing continuity galvanised iron strip 32 x 6 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engineer-in-Charge.
Supply and fix on pole 80W LED street light with pressure die-cast housing, toughened glass and secondary lens optics with IP66 ingress protection. Top opening driver cover for easy maintenance. Efficacy upto 120 lm/W Make bajaj ZELA P 96L WH PO TG SD
S& Fof PVC insulated 3 core 1.5 sqmm multistranded Copper conductor cable on pole for security light from junction box to street light fititng including making necessaey hole on surface of pole for insertion of 3 core pvc cable inside the pole upto street light fitting all as specified and directed by Engineer-in-Charge. Make:- Polycab/Havells/Gloster
M & L for marking of pole nos with radium yellow/ black paint /steekar in round shape 15 cm dia with letter writing 5 cm height 5 mm width etc. complete all as specified and directed by Engineer-in-Charge at site.
Supply, fabricate, errect, connecting, testing & commisioning Main switchgear Panel/LT Panel, Outdoor/Indoor Type, weather and vermin proof made out of 02 mm thick stainless steel sheet with front & Rear opening and locking arrangement, epoxy powder coated having colour siemens grey, 150 Amps capacity aluminium bus bar for phase, 3 No's and 1 No 150 Amp bus bar for neutral, mounted on epoxy insulator including neccessary copper control wiring, heat shrinkable, RYB coloured sleeves over bus bar for identification, earth shields, circular holes at bottom / top to receive incoming and outgoing cable, cable lugs, cable gland of sizes as required floor mounting angle iron frame made out mild steel angle iron of size 40 x 40 x 6 mm grouted on PCC (1:3:6) upto required height suitable for the following control/ fitments sensible for 3 phase, 50 Hz, 415 V system complete with and including following :- (a) Bus bar RYBN 150 Amp capacity - 01 Set (b) MCCB 100 Amps 25 kA 4 pole -01 Nos (c) MCCB 63 Amps 25 kA 4 pole -03 Nos (d) Astronomical time switch for SLP - 03 (e) LED Indicator lamp RYB - 01 Set (f) Digital multifunction meter (V, A, F, PF, KW, KVA) -01No (g) CTs -01No (set of 3) (h) PTs -01No (set of 3) Note :-(i) Make shall be CPRI approved OR CPRI license holder manufectutrer,wich certificate provide by contractor. (ii) Incoming / all outgoing MCCB's shall also be marked/ painted by the name of feeding to the place. (iii) Contractor shall be provide suitable space in LT Panel for deffects rectification in future. (iv) Contractor shall be produced Panel drawing of Panel for approval before fabrication of Panel.
Supply, installation, testing and commissioning IN REPLACEMENT of factory-fabricated 4 way VTPN Distribution Board (DB) conforming to IEC 61439-3, suitable for flush mounting or surface mounting, fabricated out of powder-coated CRCA sheet steel of not less than 14/16 SWG thickness. The DB shall be equipped with 250 A copper busbar for each phase, fully insulated busbar system, shrouded neutral bars, 2 Nos. neutral bars, 2 Nos. earth bars, and cable ties for proper cable management. The assembly shall include improved pan design for ease of installation, prefitted masking sheet, and reversible door suitable for IP43/IP54 degree of protection. The DB shall have provision for DPX³ 160A MCCB as incomer and SP/TP MCBs as outgoing feeders, complete with interconnections, earthing, testing and commissioning, all as specified and directed by Engineer-in-Charge by the Engineer-in-Charge
Supply, installation, testing and commissioning of Silent Diesel Generating Set of 20 kVA capacity, 415 Volts, 3-phase, 4-wire, 50 Hz, water-cooled, silent type, complete with diesel engine directly coupled to brushless alternator, mounted on common base frame with anti-vibration mounts and factory-fabricated acoustic enclosure conforming to latest CPCB-II emission and noise norms with foundation as per OEM design control panel with necessary meter and sound proof canopy as per CPCB norms, and 02 set of earthing The DG set shall be complete with standard control panel having necessary meters, indications, alarms and safety protections, starting battery with charger, fuel tank, exhaust system with residential silencer, flexible connections, cabling, earthing, civil foundation, commissioning, testing on load and trial run, complete all as specified and directed by Engineer-in-Charge by the Engineer-in-Charge. The DG set shall comply with IS 1001/10002 (Diesel engines), IS 13364 (AC Generators), IS 4889 (Performance of DG sets) and other relevant latest BIS/CPWD/MES specifications. The item shall be deemed complete including all minor sundries required for satisfactory and trouble-free operation, with warranty for 12 months or 2000 running hours, whichever is earlier.
Supply and fix MCCB 4 Pole , 415 V, Adjustable type, 200Amps, breaking capacity 36 KA with enclosure
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
tenderdocumemt8421final.pdf
Tender Documents • 0.95 MB
BOQ_846223.xls
BOQ • 6.34 MB
Download all tender documents and submit your bid