Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹5.0 L+₹45,034 (9.96%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹5.6 L+₹1.1 L (24.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹6.2 L+₹1.7 L (38.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
27 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN-914134 c/o 56 APO
REPAIR MAINT OF HT EXTERNAL ELECT AND REPLACEMENT OF HT CONDUCTOR AT HQ CIF UNDER AGE (I) CIF (K)
2021_MES_498252_1
134 WE-60(T)/2021-22
Open Tender
Civil Works
Item Rate
180 days
Srinagar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹14,000
Yes
27 Feb 2022
30 Dec 2021
29 Jan 2022
30 Dec 2021
27 Jan 2022
14 Jan 2022
60 days
Amount
Dismantling the cross arms of MS channel or angle sections etc., complete all as specified and directed.
Dismantling stay assembly of any type, complete all as specified and directed. Note : Demolition of concrete and earth work shall be measured and paid separately under respective items of BOQ.
Dismantling of ACSR conductor of any size, complete all as specified and directed.
Dismantling of insulator of any type and size, complete all as specified and directed.
Dismantling of old unserviceable Gang operating device (GOD) of capacity 11 KV, complete all as specified and directed. .
Dismantling earth wire in distribution span or stay strands, complete all as specified and directed.
Earthing complete with GI earth plate 60cmx60cmx6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of earth plate not less then 1.5 metre below normal ground level, conneceted to galvanized iron earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR 2009 Part-I, connected to earthing test point all as specified or indicated including earth work in any type of soil, charcoal salt, 20mm bore GI light grade watering pipe, wire mesh, funnel, PCC pit in 1:2:4 type B1 and 40mm thick cover of RCC (1:2:4) type B-0 reinforced with XPM of weight not less than 4 Kg/Sqm and with 6mm dia MS bar handle made to shape, 15 mm bore GI protection pipe light grade upto 7.5 mtr length, complete all as specified, directed.
Earthing complete with GI earth plate 60cmx60cmx6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of earth plate not less then 1.5 metre below normal ground level, conneceted to galvanized iron earth strip of size 25x4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR 2009 Part-I, connected to earthing test point all as specified or indicated including earth work in any type of soil, charcoal salt, 20mm bore GI light grade watering pipe, wire mesh, funnel, PCC pit in 1:2:4 type B1 and 40mm thick cover of RCC (1:2:4) type B-0 reinforced with XPM of weight not less than 4 Kg/Sqm and with 6mm dia MS bar handle made to shape, 40 mm bore GI protection pipe light grade upto 7.5 mtr length, complete all as specified, directed.
M&L for cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot cutting, drilling holes for bolts, in any shape or size as indicated or directed and inclusive two coat of aluminium paint over a coat of red oxide zinc chrome primer after prepration the surface, complete all as specified and directed.
M&L for ACSR conductor in over head lines of HT poles including stretching the aluminium conductor and binding with binding wires of aluminium tapes, complete all as specified and directed.
S&F in replacement danger notice plate, made of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25x3 mm MS flat, bolts and nuts, of size 25x20 cm, suitable for HT, complete all as specified and directed.
M&L for galvanised steel wire 3.15/4 mm dia stretching on HT OH line using as earth continuity conductor.
S&F pin type white, brown and green insulator incl one galvanised mild steel spindle, two galvanished iron washer and one GI nut, of size 150mm high, 150mm dia for 11000 Volts grade, complete all as specified and directed.
S&F disc type insulator, vitreous of size 145mm height and 255mm dia and socket type, white, brown or green single disc assemble for tension with tension clamps for conductors working pressure 11000 volts, complete all as specified and directed.
S&F cable jointing kit for 11 KV grade cable, outdoor termination, heat shrink type joint, complete with jointing material and accessories, suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm, complete all as specified and directed.
All as per Ser item No 15.00 above, but size of cable 3 core 95 Sqmm.
S&F cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
All as per Ser item No 17.00 above, but size of cable 3 core 95 Sqmm.
S&F in old and new places stay assembly using GI stay rod 20mm dia, complete with accessories as shown in electrical plate No 1, complete all as speceified and directed. Note :- Earth work and concrete shall be measured and paid separately under respective items of BOQ.
S&F in replacement of GI tube light grade 80mm bore pipe for cable protection, laid in trenches or fixed on pole and along the wall with suitable clamps, complete all specified and directed.
Supply and fixing, testing and commissioning air break gang isolating switch, triple pole, mechanically operated with vertical/ horizontal isolation mounted on 12 insulator and steel frame with operating mechanism worked from ground level and including operating rod of 25mm dia medium grade GI of required length and locking arrangements of capacity 200 Amps 11 KV with and incl drop out fuse set complete including making all incoming/ outgoing connections all as specified and directed and painting of steel work with two coats of aluminium paint over a coat of red oxide primer and including taking down old one, complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded crushed stone agg) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for PCC 1:3:6, type C-1 (using 20mm graded crushed stone agg) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for 40mm graded coarse aggregate (broken stone or boulders), surrounding the transformer, panel board and under the two/ four pole structure, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc. and getting out in hard / dense soil, complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming to a layer not exceeding 25 cm, complete all as specified and directed.
Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured & paid.
M&L for sub class 'B' brick covering protection to the eletric cable, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of brick, complete all as specified and directed.
Supply, laying, testing and commissioning XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade, of size 3 core 120 sqmm, laid in trenches/ floor/ duct/ fixed on poles through GI tubing, complete all as specified and directed.
Supply, laying, testing and commissioning XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade, of size 3 core 150 sqmm, laid in trenches/ floor/ duct/ fixed on poles through GI tubing, complete all as specified and directed.
S&F in replacement cable jointing kit for 11KV grade cable for Straight through joint heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 120 sqmm, complete all as specified and directed. Make : 3M/ Birla/ Denson.
S &F in replacement of Lighting arresters expulsion type complete with all fittings, suitable for volts 11000 V and discharge capacity 65 Kilo Amps complete all as specified and directed by Engr-in-Charge
Note : Amount of credit of "Rs 18730.00" for retrieved material is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
M/S YATTOO CONTRACTORS
M/S ZAHOOR ENTERPRISES
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .