Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.9 LAccepted-Finance | 1 | Accepted-Finance ACCEPTED | |
| 2 | 2₹22.1 L+₹14,040 (0.64%)Accepted-Finance | 2 | Accepted-Finance ACCEPTED | |
| 3 | 3₹26.1 L+₹4.2 L (19.0%)Accepted-Finance | 3 | Accepted-Finance ACCEPTED |
Tender Value
₹28.3 L
EMD Value
₹56,552
Closing Date
30 Aug 2021, 10:00 amClosed
Executive Engineer, MID, Hut Bay
Executive Engineer, MID, Hut Bay
Repair and Renovation of Type-II 04 Nos. (S/S) Qtr. No. 01 to 04 of APWD Colony, Hut Bay.
2021_APWD_3464_1
15-22(2)/DB/MID/2021-22/388 dt. 06/08/2021
Open Tender
Civil Works - Buildings
Works
120 days
Hut Bay
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Executive Engineer, MID, Hut Bay
₹56,552
Yes
31 Aug 2021
9 Aug 2021
31 Aug 2021
9 Aug 2021
30 Aug 2021
18 Aug 2021
10 Aug 2021 - 17 Aug 2021
Amount
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level :
1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).
6 mm thick Cement fiber board as per IS: 14862
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Gutter (600 mm over all girth)
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
One or more coats on old work
Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer's specification.
One or more coats on old work
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (One or more coat applied @ 0.90 ltr/10 sqm).
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead :
Of sectional area below 40 square centimetres
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
G.S. Sheet
Asbestos Cement sheet
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
Providing and laying hollow cement concrete block walling upto floor five level 200 mm thick consisting hollow block of size 400 x 200 x 200 mm of mix 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 10 mm nominal and down size) laid in cement mortor 1:6 (1 cement : 6 coarse sand).
Providing and fixing precoated galvanised iron profile sheets of brand TATA Blue scope/Everest or equivalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing 6mm dia G.I.hanger (Upto 2.5m length) fixed one end with roof truss member & another end with aluminium ceiling member complete as per direction of Engineer In Charge.
Construction of septic tank with cement concrete wall with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) including RCC precast top slab 10cm with CC 1:1.5:3 ( 1 Cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), 20cm foundation concrete 1:4:8 mix (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with water proof cement mortar 1:4 (1 Cement : 4 fine sand) finished with floating coat of neat cement 50mm thick CC flooring 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate ) including RCC buffle wall 10cm with terminal guard and two man hole cover of 455x610 mm rectangular C.I cover (light duty) fixed in RCC slab, MS foot rest at 30cm cement concrete etc. complete as per standard design, drawing and direction of Engineer-in-change.
For 50 User
Providing and fixing in position eaves or facia board with PVC board (30cm width & 19mm thick) along with necessary fixing arrangements including nuts and bolts and drilling holes etc all complete. 19mm thick.
PRASANTA KANRAR
AMAL DAS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .