| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721305 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹24.9 L+₹1.1 L (4.52%)Rejected-Finance | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹26.9 L+₹3.1 L (13.0%)Rejected-Finance 60 310A 3 KHERIA MOD JAGNER ROAD AGRA 01 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹28.7 L+₹4.9 L (20.6%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹38.4 L+₹14.6 L (61.2%)Rejected-Finance 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TECH AREA AGRA
GE AF TECH AREA AGRA
REPAIR MAINT OF ELECTRICALLY OPERATED HANGER GATE INSTALLED AT BLDG NO P 567 P 568 P 569 P 570 T 7 AND T 8 UNDER GE AF TECH AREA AGRA
2023_MES_576482_1
8200-1487/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE AF TECH AREA AGRA
AS PER NIT
9 documents required · 9 mandatory
₹500
GE AF TECH AREA AGRA
₹80,000
Yes
29 Mar 2023
21 Jan 2023
20 Feb 2023
21 Jan 2023
18 Feb 2023
4 Feb 2023
21 Jan 2023 - 28 Jan 2023
Amount
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 22 Mtr) for Bldg No P-567 front and rear having total 24 leaves(12 leaf each side) including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly as per specification limit recommended by OEM etc complete all as specified and directed.
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 22 Mtr) for Bldg No P-568 front and rear having total 24 leaves(12 leaf each side) including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly as per specification limit recommended by OEM etc complete all as specified and directed. .
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 22 Mtr) for Bldg No P-569 front and rear having total 24 leaves(12 leaf each side) including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly as per specification limit recommended by OEM etc complete all as specified and directed.
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 15 Mtr) for Bldg No P-570 front and rear having total 8 leaves(4 leaf each side) including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly as per specification limit recommended by OEM etc complete all as specified and directed.
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 22 Mtr) for Bldg No T-7 front side having 8 leaf including greasing/ oiling and repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly as per specification limit recommended by OEM etc complete all as specified and directed.
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 22 Mtr) for Bldg No T-8 front side having 8 leaf including greasing/ oilingand repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly as per specification limit recommended by OEM etc complete all as specified and directed.
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 15 Mtr) for Hanger No-10 (45 ED) front and rear side having 8 leaf including greasing/ oilingand repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly as per specification limit recommended by OEM etc complete all as specified and directed.
Repair & maintenance of guide chanel & wheels (Hanger gate having height upto 15 Mtr) for AN-32 Hanger front and rear side having 12 leaf including greasing/ oilingand repair maintenance and servicing of gear box for smooth transmission of power to operate the gate smooothly as per specification limit recommended by OEM etc complete all as specified and directed.
Note : For Item 1 to 8:- (i) Contractor shall visit the site of work prior quoting the rates against respective items. Further the contractor shall visit to site every week and will check and carry out service and repair as to required at site and as directed. (ii) Payment will be made only once for the month for any number of complaints/breakdowns . (iii) Any other repair/maint required shall be measured & paid seprately(as persite requirement) under respective items herein after. (iv) During maintenance and replair/replacement of gate, any damage including civil work occurs, the same shall be make good by the contractor without any exta cost to Govt. (v) Contractor shall repair/replace the item of gate and make the gate smooth for working/operating with immediate as pointed out by Engineer-in-Charge. If contractor fails to do the same within 07 days, a panelty for the same @ 2000/- per day shall be charged from the contractor. (vi) Cost of all the special T&P and tools including boom lift etc as required shall deemed to be included in the unit rate quoted. No extra charge shall be paid for this purpose. (vii) Ther contractor will approach OEM/rep of OEM for any special nature of work as and when required during currency of contract and cost to that effect shall be deemed to be included in quoted rates. (viii) Contractor shall deploy trained tradesmen. The trade men shall be qualified to keep the equipment properly and take care to maintain hanger gate in proper and safe operating condition (ix) Contractor shall be examine periodically maintenance and repair including safety devices and make proper record of testing in the form of monthly quarterly and yearly basis.
S&F mild steel work such as stopper to guide chanel/guide chanel and other similar items including cutting welding. Confirming to E-290 grade E-165 as per existing shape/size complete all as specified and directed.
M&L for welding n exc 10 cm in length and thickness of metal to be welded not exc 6mm complete all as specified and directed.
S&F in repair proxy switches M-30 of existing capacity complete all as specified and directed
S&F in repair indicator of gate fixed at door with start stop and emergency switch of existing make/size/capacity complete all as specified and directed.
M&L for repair/maint including replacement of defective/wornout parts in control panel of gate including wiring & electrical fitting/fixture (from control panel to starter) complete all as specified and directed.
S&F in repair of unserviceable glass relay 24V DC,500 ohm complete all as specified directed.
S&F in repair MCB SP 6 to 32 Amp 240 V 'C' Series 10 KA complete all as specified and directed.
S&F in repair MCB TP 32 to 63 Amp 240 V 'C' Series 10 KA complete all as specified and directed.
S&F in repair power supply AC to DC 220V/24V complete all as specified and directed.
S&F laying in repair connecting and testing of LT Cable of size 2.5 Sqmm 4 core, 1100 Volt PVC insulated heavy duty flexible cable with ennealed bare copper conductor flexible industrial cable complete all as specified and directed.
S&F/ Laying in repair connecting and testing of LT Cable of size 1.0 sqmm 4 Core 1100 Volt PVC insulated of flexible cable with ennealed bare copper conductor flexible industrial cable complete all as specified and directed.
S&F in repair controlled wire of size 1 Sqmm multi standard copper conductor PVC insulated with colour code grey & black complete all as specified and directed.
S&F in repair PVC connector with 2 Amp rating glass fuse NS4 complete all as specified and directed.
S&F in replacement thermal over load relay of capacity 5 to 12 Amp rating complete all as specified and directed.
S&F in replacement contactor 3 pole 220 Volt 16Amp with NC block complete all as specified and directed.
Supply & refilling/ Top up of gear oil in special geared motors .
M&L for Radium sheet with letters or numbers of any width & height , pasted on 0.5mm thick galvanised plain sheet of size 1.5mx1.5m with necessary fixing arrengement on hanger doors complete all as specified and directed
Dismantling / taking out gear motor capacity 2/2.5 HP 3 phase including disconnecting electric connection complete and transporting to workshop for repairing works including rewinding with super enamelled copper winding wire of existing gauge and replacement of unserviceable bearing etc complete all as specified and directed
M&L for repair/maintenance of top track trolly with 12 Nos horizontal axis rollers & 4 Nos vertical axis rollers greasingoiling of rope, minimum 15 Nos cable carrieer on each horizontal leaf, replacement of any part i.e hardware, bearings for smooth working/operation of gate complete all as specified and directed. (For hangar height upto 22 Mtr)
M & L for repair/maintenance of top track trolly with 8 Nos horizontal axis rollers & 4 Nos vertical axis rollers including greasing/oiling of rope, minimum 10 Nos cable carrieer on each horizontal leaf, replacement of any part i.e hardware, bearings for smooth working/operation of gate complete all as specified and directed. (For hangar height upto 15 Mtr)
M & L for repair/maintenance of top track trolly with 8 Nos horizontal axis rollers & 4 Nos vertical axis rollers including greasing/oiling of rope, minimum 15 Nos cable carrieer on each horizontal leaf, replacement of any part i.e hardware, bearings for smooth working/operation of gate complete all as specified and directed. (For hangar height upto 22 Mtr)
M&L for repair/maintenance of top track trolly with 4 Nos horizontal axis rollers & 4 Nos vertical axis rollers including greasing/oiling of rope, minimum 10 Nos cable carrieer on each horizontal leaf, replacement of any part ie. hardware, bearings for smooth working/operation of gate complete all as specified and directed. (For hangar height upto 15 Mtr)
M&L for repair/maintenance of top track trolly with 6 Nos horizontal axis rollers & 4 Nos vertical axis rollers including greasing/oiling of rope, minimum 12 Nos cable carrieer on each horizontal leaf, replacement of any part ie. hardware, bearings for smooth working/operation of gate complete all as specified and directed. (For hangar height upto 15 Mtr)
M&L for painting for sheet metal enclosure of LT panels of size 1.5mx1.2mx0.5m) with two coats of synthetic enamel paint as directed including preparing the surfaces by scraping of old paint and applying a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Taking down carefully Aluminium/copper/Flamp proof point wiring (Light/ Fan/Socket or power) complete incl fitting fixture such as switches, sockets, ceiling rose, brackets, holders, bulk head fitting etc and making good disturbed surface of wall/ceiling etc, all as specified and directed.
Taking down main switch/MCB DB/AC enclosure/Three phase enclosure by disconnecting the electric supply all as directed by Engr-in-Charge.
Taking down security light any type by disconnecting the electric supply all as specified and directed.
Taking down old U/S sub main wiring of any size and any descripting including batten/conduit and making good disturbed surface to match the existing surface etc complete all as specified and directed.
M&L for point wiring for hanger light complete with multistranded copper conductor 2.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and including steel conduit ISI marked not less than 20mm dia with including 2.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed: - Note:- The Contractor shall consider average length of wiring as 35.00 RM in each point. The quoted rate shall be deemed this aspect during quoting the rate.
One hanger light controlled by one MCB SP
Two hanger light controlled by one MCB SP
S&F in replacement LED high bay light fitting of 150 watt complete with bright energy saving,environment friendly & robust open type verticle Highway LED luminaire with high power Decrete LED of 150 watt LED IP-65 luminiare with high efficiency complete all as specified.Make- Havells cat part SAUCERPLUSSHBP150WLED85790DTOLTG or Crompton cat part LHB11-150-CDL/60-M or equivalent as approved by GE
M&L sub main wiring along with earth wire by using FR PVC insulated copper conducter , single core cable in surface 2x4 Sqmm plus 1x4 Sqmm green colour earth wire in and incl PVC conduit of not less than 20mm dia medium grade ISI marked, complete all as specified and directed.
M&L for sub main wiring drawing in and including PVC conduit not less than 20mm dia medium grade with PVC cable 6 Sqmm nominal area 2 single core PVC insulated unsheathed cable with stranded copper conductor incl 6 Sqmm nominal area single core PVC cable stranded copper conducter as earth continuity wire and connected to earth dolly etc complete all as specified and directed.
M&L for sub main wiring drawing in and including PVC conduit not less than 20mm dia medium grade with PVC cable 10 Sqmm nominal area 2 single core PVC insulated unsheathed cable with stranded copper conductor incl 6 Sqmm nominal area single core PVC cable stranded copper conducter as earth continuity wire and connected to earth dolly etc complete all as specified and directed.
M&L for sub main wiring drawing in and including steel conduit not less than 20mm dia medium grade with PVC cable 6 Sqmm nominal area 4 single core PVC insulated unsheathed cable with stranded copper conductor incl one single core 6 sqmm nominal area PVC cable stranded copper conducter as earth continuity wire and connected to earth dolly etc complete all as specified and directed.
S&F DB TPN 4 way Vertical type,440V,3 phase with rated busbar 250 Amps, double door type suitable for MCCB of 125 Amp as a incomer and MCBs as out going ,IP 54-IK 09 including grouting in the wall by using PCC 1:2:4 type BI using 20mm graded aggregate and making good disturbed surfaces to match with existing surfaces etc complete all as directed.
M&L for MCB DB of sheet metal enclosure double door type, single pole and neutral 8 way with 200 Amp rated bus bar 240V and grouted in walls by using PCC 1:2:4 type BI (using 20 mm graded aggregate) making good disturbed surfaces to match with existing surfaces etc complete all as directed.
S & F MCB SP 6 to 32 Amps, 240V 'B' Series 10 KA.
S & F MCB DP 40 to 63 Amp 240 Volts 'B' series 10 KA.
S & F MCB TPN 63 Amp 415 Volts 'C' series 10 KA.
S & Fixing MCCB DPX 160 thermal magnetic of 125 Amps 4 pole 16 KA, 415 Volts 50 Hz complete including connecting all incoming and outgoing connection by means of suitable size of lugs/thimbles all as specified and directed.
.S&F in replacement DB enclosures with MCB protected suitable for AC including socket plug top and MCB single pole with a two pin and earth plug and socket complete 20 Amp MCB ,240 volts making good disturbed surfaces to match with existing surfaces etc complete all as directed.
.S&F sheet metal enclosures with socket plug top and MCB TPN,3 pole and neutral enclosure with a three pin and earth plug and socket complete with one triple pole MCB of 20 Amp ,440 volts complete all as specified and as directed by the Engineer in charge
Balaji Associate
rohan traders
MUKTA AND COMPANY
Industrial Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .