Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.9 L+₹4.0 L (13.3%)Rejected-AOC HOUSE NO 3363 SECTOR 27 D CHANDIGARH | NA | NA | 160001 | L2 | Rejected-AOC L2 |
Tender Value
₹28.8 L
EMD Value
₹57,600
Closing Date
5 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh AP Singh, IDSE, SE
HQ CWE Chandimandir
CA NO CWE/CHD-23/2020-21 SPL REPAIR TO BLDG NO 5, 6, 44 AND 135 (OTM ACCN) AT MIL STN NAHAN UNAER GE CHADIGARH
2020_MES_351209_2
CWE/CHD-23/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class D, Cat a(i)
7 documents required · 7 mandatory
₹500
Yes
GE Chandigarh
₹57,600
Yes
12 Sept 2020
9 Jul 2020
7 Aug 2020
9 Jul 2020
5 Aug 2020
23 Jul 2020
60 days
Amount
Demolition of brickwork or stone/boulder masonary, built in cement mortar including quoins arches, pillers etc, but excluding ashlar facings, dressed stone work and precast concrete article built in cement mortar or cement lime mortar complete all as specified and directed.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for incl cutting of reinforcement as required to facilitate demolition complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, incl nainital or similar pattern roof covering complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets, wooden grid work etc complete all as specified and directed.
Taking down chowkats or frame exc 1.5sqm but n.exc 4 sqm each(without taking shutter from the frame) with all fittings complete all as specified and directed.
Taking down chowkats or frame n. exc 1.5sqm each(without taking shutter from the frame) with all fittings complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces incl racking out joints, hacking for key complete all as specified and directed.
Demolitioin of cement concrete in ground floors and pavings n.exc 15cms thickness (below or above GL) complete all as specified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing tiles and rubish off the premises complete all as specified and directed.
Dismantling structural steel work including doors, gates framed truss etc complete all as specified and directed.
Excavating in trenches n. exc. 1.5m wide and n. exc.1.5m in depth for laying of foundation, sewage/water lines etc n. exc. 10 Sqm on plan and getting out in any type of soil complete all as specified and directed.
All as per item No 11 above but in soft/disintegrated rock complete all as specified and directed.
M&L for Hardcore broken stone of gauge not exceeding 63mm deposited, spread & leveled in layers not exc 15cm thick watered, rolled and rammed to a true surface complete all as specified and directed.
Plain cement concrete (1:3:6), type C1 using 20mm graded stone aggregate as in Plinth protection,50mm thick finished even and fair complete including necessary form work complete all as specified and directed.
Earth filling under floors incl spreading, leveling, watering and well ramming in layers not exceeding 15 cm thick complete all specified and as directed.
Removal of excavated soil to a distance exc 250 metre and n.exc 500m depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and directed.
Plain cement concrete (1:4:8), type D-2 using 40 mm graded stone aggregate as in foundations, filling , mass concrete and sub base complete all as specified and directed.
Returning and filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick using soft/disintegrated rock complete all as specified and directed.
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
RCC M-25 Design mix, using 20mm graded trap stone aggregate for concrete as in foundation, rafts, footings, plinth beams, bases of columns etc.,complete all as specified and directed..
RCC M-25 Design mix, using 20mm graded stone aggregate for concrete as in slabs, floors, roofs, landings, balconies, canopies and shelves etc., complete all as specified and directed..
RCC M-25 Design mix, using 20mm graded stone aggregate for concrete as in beams, cantilevers, bressummers, lintels beyond 1.5m span etc., complete all as specified and directed.
RCC M-25 Design mix, using 20mm graded stone aggregate for concrete as in columns, pillars, piers, posts and struts etc., complete all as specified and directed.
RCC M-25 Design mix, using 20mm graded stone aggregate for concrete as in chajjas, complete all as specified and directed.
Formwork to sides of concrete foundations, footings, base of columns, raft and raft beams, plinth beams, vertical, finished rough complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slab, landings and similar work not exceeding 200mm thick, horizontal or sloping finished rough complete all as specified and directed.
Formwork for sides & soffits of floor or roof beams including bressummers, lintels, cantilevers, shelves including soffits etc complete finished rough complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions of square or rectangular finished rough complete all as specified and directed.
Formwork to edges of concrete flats, treads, railings, openings in walls, floor and roofs, sides of RCC/PCC bands, horizontal or sloping n.exc 20 cm wide for rough finished surfaces. complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces. complete all as specified and directed.
M&L of Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L stone walling built in CM 1:6 of random rubble uncoursed, well bonded,solidly hearted built as in retaining walls, abutment and similar work but except stone. Note :- Stones ontained from item No 1 to be reused.
Rendering 5mm thick in CM (1:3) on concrete surfaces of ceiling, soffits of slabs, shelves, isolated RCC members etc., finished even and smooth without using extra complete all as specified and directed.
Rendering 10mm thick in CM (1:6) on fair faces of brick/block masonry wall surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick plaster in CM (1:4) on concrete surfaces incl roofs finished even and fair without using extra cement using WPC as per manufacturer's instructions complete all as specified and directed.
Supply only integral water proofing compound all as specified and as directed.
Preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
Preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for applying 3mm thick wall care putty on wall surfaces including rubbing down with sand paper to have even and smooth surface complete all as specified and as directed.
All as per item No 42 here-in-before but on ceiling surfaces complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed.
Preparation of new plastered surfaces of ceiling and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed.
M&L for preparing new plastered surfaces and applying two coats of cement based paint on concrete /plastered surfaces, complete all as specified and directed.
TMT bars 10mm dia and over cut to length , bent to shape required including , cranking hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 47 above but 6mm to 8mm dia complete all as specified and directed.
TMT bars 5mm dia and over upto and incl 10mm cut to length, bent to shape required including, cranking hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers, binders etc complete all as specified and directed.
Providing and fixing anodised aluminium work for door windows, ventilators, casement/sliding shutters and partitions with extruded built up standard tabular and other sections of approval make fixed with rawl plugs and screws or with fixing clips or with expansion hold fastner incl neceesary filling up of gaps at junctions at top bottom & sides with required PVC neoprene belt etc. Aluminium section shall be smooth rust free straight mitred and jointed mechanically where ever required including cleats angles, aluminium snap beading for glazing/panelling, CP brass/stainless steel screw incl providing hinges/pivot and making provision for fixing of fittings where ever required. Note:- panel fillings other than aluminium filling and necessary fittings shall be measured and paid for separately under respective items.
S&F double charged/ultracharged Virified Ceramic tiles 10 mm thick (square/ rectangular) scratch & stain resistant, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per item No 51 here-in-before but in vertical surfaces over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
S&F 25mm dia powder coated decorative curtain rod with and including brackets and end caps etc complete all as specified and directed.
S&F 4.0mm thick tinted sheet glass, fixed with putty as in windows etc complete all as specified and directed.
All as per item No. 54 here-in-before but pin headed/figured glass.complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and and average width of aperture not more than 1.40mm fixed with stainless steel wire staples.complete all as specified and directed.
M&L kota slab 16-18mm thick in risers of steps, skirting dado and pillar laid over cement screed bed jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with and incl backing coat 10mm thick in CM 1:4.complete all as specified and directed.
M&L machine cut Kota stone slab 20 to 23mm as in floors etc laid over cement screed bed jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with and incl 20mm thick screed bed in CM 1:6 .complete all as specified and directed.
M&L 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.complete all as specified and directed.
S&F grating doom 100mm dia mild steel chromium plated complete all as specified and directed.
S&F 35mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F Pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.
S&F Pressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed.
S&F Door closure hydraulically regulated designation No 3 universal type suitable for door shutter of 851 to 1000 mm in width of Aluminum body (die cast) weight between 61 to 80 kg complete all as specified and directed.
S&F stainless steel Butt hinge 100mm size complete all as specified and directed.
S&F extruded aluminium alloy, fabricated type handle, 150mm long complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
M&L for APP based polymeric membrane minimum weight 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non woven fabric laid over and including priming surfaces with primer of same manufacturer @ 0.400 Litre/Sqm and laying APP membrane on Primed surface by torch application and sealing all joints and overlapping complete all as specified and directed.
Damp proof course, 40mm thick in cement concrete (1.2.4) type B-0 using 12.5mm graded stone aggregate using WPC to horizontal & vertical surfaces including necessary form workcomplete all as specified and directed. (WPC shall be measured and paid separately).
Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cum per sqm complete all as specified and directed.
M&L for polythene film, 50 micron thick, laid over a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m complete all as specified and directed.
S&F straight edge (joint free) non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm, in floors etc.in any colour or pattern, set and jointed in neat cement slurry and pointed in white or coloured cement to match with and inluding 15mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F straight edge (joint free) glazed ceramic tiles 450 x 300 x 7mm thick coloured on vertical surfaces such as dado skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
Salt glazed stone ware gully trap, square or round mouth type ‘P’, size 150mmx100mm complete all as specified.complete all as specified and directed.
M&L preparing new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Cutting chases in stone wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S&F 15mm bore GI tubes medium grade with all fittings & fixed complete to walls or ceilings or laid in floors.complete all as specified and directed.
All as per item No 78 here-in-before but 20mm dia bore complete all as specified and directed.
M&L 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
Taking up or down steel water tubing 15mm dia and connection incl cleaning refifixing or removal to store.
Ditto but 20mm dia GI tubing complete all as specified and directed.
S&F for Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel complete all as specified and directed.
S&F in repairs 10 ltr capacity PVC vlaveless syphonic action type flushing cistern low level,white with inlet ball valve,float and handle including complete all as specified and directed.
S&F in repair vitreous China wash basin, white Flat back waste size 550x400 mm including brackets, CP waste cupling and PVC waste pipe complete all as specified and directed.
S&F plastic water closet seat cover black/whit closed pattern with flat bottom and cover and mild steel chromium plated or aluminium devices. complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repair, cleaning, etc. and hoisting if required reconneecting and refixing in position (Cleaning repairing etc measured separately) exc 250 & n.exc 500 ltr in capacity complete all as specified and directed.
S&F 500 Ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (pedastal pattern) white (exclusing fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm.
S&F in repair brass chromium plated Tubler towel rail, 20mm dia, D type, 60cm long between flange complete all as specified and directed.
S&F in repair 15mm dia Ball brass valves high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Taking down CI soil waste or vent pipe 100mm bore including all fittings like trapes, bends, junctions etc from any situation complete all as per specified and as directed.
Taking down CI soil waste or vent pipe 75mm bore including all fittings like trapes, bends, junctions etc from any situation complete all as per specified and as directed.
S&F 110mm bore PVC SWR Pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors.complete all as specified and directed.
S&F 75 mm bore PVC SWR Pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors.complete all as specified and directed.
S&F in repair 110mm bore PVC SWR Bends any radiuscomplete all as specified and directed.
S&F in repair 75mm bore PVC SWR Bends any radius complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent complete all as specified and directed.
S&F in repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for 15 mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm dia bib taps CP brass,fancy type,long body, screwed down, screwed for iron pipe.complete all as specified and directed.
S&F in repair 15mm dia Angle cock chromium plated brass fancy type, screwed down , high pressure, scrwed both ends for iron pipe.complete all as specified and directed.
Taking down carefully coppper /aluminium point wiring (light, fan,socket,and power) complete including all switch sockets ceiling roses switch boards regulator etc and disposal under schedule of credit and making good disturbed surfaces all as specified.
Taking down MCB DB of any size and disposal under schedule of credit and making good disturbed surfaces all as specified.
Taking down old unserviceable light fittings any type and removal from site and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed by Engineer-in-Charge to match with existing surface.
M&L for Point wiring for One light point controlled by one switch 5 Amp SP one-way complete with 1.5 Sqmm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including PVC concealed conduit (medium quality) and conduit fittings including 1.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly including suitable size MS sunken for fixing modular switches,sockets,regulators with frame and top cover and machine made brass screw and washers etc complete all as specified and directed for one light point controlled by one one way switch. Notes:- (i) Make of Cable : FINOLEX/ C&S/ Grandly, Paragon,Polycab, Plaza or eqnvalert make specified in Appx'B' (ii) Rigid PVC conduit (ISI marked) shall be fire retardant, ISI H MS, IS-9537, Part-3, CML-794006 and shall be any of the make : supreme /Prince/ Diplast/Finolex. (iii) For Internal wiring colour to be used as per IE rule for Phase - Red/Yellow/Blue, Neutral - Black. and Earth – Green(iv) Making good on disturbed surfaces and quoted rate including M&L for white/colour wash (existing colour) to macth with existing. surfaces, complete as directed by Engineer-in-Charge(v) Switch/socket to be measured and paid separately.
All as per item No 110 here-in-bore but for one socket outlet 3 pin, 5 Amps on the same board.
All as per item 110 here-in-bore but for one socket outlet 3pin, 5 Amps on the independent board.
All as per item 110 here-in-bore but for one socket outlet 3 pin 15 Amps on independent board using cable of size 2.5 Sqmm for phase & neutral and 2.5 Sqmm as earth wire.
All as per item 110 here-in-bore but for one ceiling fan/exhaust fan point.
S&F Modular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified.
S&F Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified.
S&F Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specified
S&F Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified.
S&F Modular Fan step Regulator electronic, 120 watts 2 Module complete all as specified.
S&F Modular white cover plate incl Modular base frame & powder coated Modular sheet metal concealed box for 6 module complete all as specified.
All as per item 120 here-in-before but 3 module complete all as specified.
All as per item 120 here-in-before but 8 module complete all as specified.
All as per item 120 here-in-before but 2 module complete all as specified and directed.
S&F ceiling rose surface backalite 65 x 50 mm, two to three terminals complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate suitable for any type of fitting all as specified and directed.
Taking down and re fixing the existing water geyser/ Ceiling fan/exhaust fan any/type and any size after necessary servicing/greasing complete incl painting all as specified and directed by Engr-in-Charge to match with existing surface.
Supply and fixing Indoor Decorative LED T8 batten with opal diffuserwith LED tube Light T8, 20 watt, 4 ft white 230 V, complete with Power coated all accessories internally pre wired and including up with three core PVC copper flexible cable of size 23/0.0076 from ceiling rose to connector block complete all as specified and directed by Engineer-in-Charge Make :- Halonix - Cat part no- HLB-02-20-CW or equivalent make specified in Appx 'B'.
Material & labour for Integrated LED Bulk Head Luminaire comprises of Pressure die cast housing, Acrylic diffuser & frame with IP65 Protection 10 watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz complete all as specified and directed. Make :- Crompton Cat No - LBHN-10-WW or equivalent Make specified in Appx' B'.
Supply and fixing LED slim panel recess/surface suspended mounting 36 watt 2' x 2' LED ceiling light with extruded aluminium housing and milky diffuser complete all as specified and as directed. Make :- Halonix Cat No - HLFPU22-02-36-C or equivalent make specified in Appx 'B'.
S&F sheet metal enclosure for DB's , MCB DB TPN 4 way complete all as specified.
S&F sheet metal enclosure for DB's , MCB DB SPN 8 way complete all as specified.
S&F isolator TPN 63 amp 230 Volt complete all as specified
S&F isolator SPN 40 amp 230 Volt complete all as specified and directed.
S&F MCB single pole 230 Volts of capacity 6 to 32 A complete all as specified.
Supply and fix off load change over switch 4 pole 415 VAC, 50 Hz 100A side handle operated conforms to IS/60947-1 & 3 complete all as specified and as directed.
S & F Sub main wiring with PVC insulated, FRLS cable 2 single core 6 Sq mm 1100 V grade with stranded copper conductor on and incl PVC rigid non metalic conduit (ISI marked) in concealed incl all specials like joint, elbow , Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 6 sqmm for earth continuity conductor complete all as directed by Enginer-in-charge. Note :- 2 runs of 6 sqmm cable and 1 rum of earth wire shall be measured as 1 unit.
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI wire 4 Sqmm dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
M&L for Brick protection for LT cable with sub class B bricks laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10mm with width equal to length complete all as specified and directed.
M&L for sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed.
Supply and lay GI tubing, light grade, 50 mm bore dia as cable protection fixed on walls/poles/laid in trenches complete including dismantling corroded GI pipe all as specified and as directed.
Supply, laying, jointing testing and commisioning LT underground cable 1100 volts grade XLPE insulated and steel strip or wire armoured heavy duty with multistranded aluminium conductor 25 Sqm 4 core size complete all as specified and directed by Engr-in-Charge. Note:- (i) Excavation and earth work cable protection and sand cushioning shall be measured and paid seperately under respective item.
His Construction Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .