Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹27.5 L+₹71,399.50 (2.67%)Rejected-AOC 13 218 MASJID EXTEN SADAR BAZAR | L2 | Rejected-AOC higher rate | |
| 3 | L3₹31.6 L+₹4.9 L (18.3%)Rejected-AOC FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L3 | Rejected-AOC higher rate |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
23 Dec 2022, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI
CA NO GE/ND-74/2022-23 REPAIR/MAINT OF EXTERNAL WATER SUPPLY AND SWIMMING POOL IN NAVY AREA UNDER GE NEW DELHI
2022_MES_565298_1
GE/ND-74/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹70,000
Yes
31 Mar 2023
25 Nov 2022
26 Dec 2022
25 Nov 2022
23 Dec 2022
9 Dec 2022
Amount
Material and labour for Cleaning of NSB-I Swimming Pool of size 25 m x 13.5 m using Eco friendly / harmless to human being cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transparent water all the time before filling as required at site complete all as specified and as directed. M&L for cleaning of swimming pool by taking out of muddy water and removing the mud/settled particles and all other foreign material from the swimming pool and depositing where directed but not less than 50 mtr from the starting point including scraping / removing all dirt/scales from the internal wall of the swimming pool and washing the bottom surface and wall surface of the swimming pool with clean water, draining out the dirty water so that the whole swimming pool be thoroughly cleaned after pumping out all existing water by portable centrifugal/mono block pumping set, applying sulfuric acid on surface and wall of swimming pool and outer drain out path for removing the settled chemicals on surface/wall. after cleaning with sulfuric acid filling up of swimming pool with fresh water and make the pool water crystal clear when pool is start and make the bottom clear when pool is closed. Note:-Quoted rates shall inclusive of manpower and cleaning material, safety gears and ladders etc required at site for filling up the swimming pools with water and de-watering on completion of Operation and Maintenance of swimming pools
Supply and charging(filling in) in replacement of old worn out/uncleaned/choked filter media in filtration cum recycle plant of capacity 100000 ltrs/hr to maintain the desired filter flow rate as recommended by manufacture and swimming pool norms complete all as specified and directed. Filter media details are as under:-
(i) Media Depth – 915 MM (ii) Quart Pebbles of 1" – 3/4" size Not less then 100 mm thick layer (iii) Quart Pebbles of 3/4" to 1/2" size Not less then 100 mm thick layer (iv) Quart Pebbles of 1/2" to 1/4" size Not less then 100 mm thick layer (v) Quart Pebbles of 1/4" to 1/10" size Not less then 100 mm thick layer (vi) Quart sand of assorted sizes Not less than 900mm thick layer (vii) Making Back wash arrangement functional/repair – Back wash arrangement shall be made through the running water hence arrangement shall be made to facilitate the back washing system. (viii) Replacement of Pressure gauges and flow meters from Filtration plant.
(ix) Repair and replacement of Air release pipe and valve from all filtration plant .
Material and labour in replacement of Suction sweeping complete Assembly with desired SS suction head with PVC wheel, spring loaded brush & rubber squeezer including trolley (MS Painted Trolley with wheels) mounted non clog self priming centrifugal pump of 3 HP TEFC three phase motor & DOL starter, 50 meter long flexible 3 core copper cable, 30 mtrs 40mm dia PVC hose pipe, 50 meter long rope including 02 Nos algae brushes, leaf net 1 Nos, Test Kit 1 No and float ball PVC 8" - 20 Nos complete all as specified & as directed.
Servicing of the following control devices/Equipment for controlling/cleaning/measuring inlet and outlet of water supply for making them functional after thoroughly opening, greasing the moving parts, gland rope filling of the similar size and length, tightening the gland plate and reassembling the same for smooth operating:-
(a) Existing Sluice Valves/foot valve/NRV of any size
(b) Existing Strainers of any size in existing pipe lines
(c) Butter fly valves of any size
Material and Labour for fabrication in replacement of rusted base frame with MS Channel of existing size for foundation of booster pump set including two coat of synthetic enamel black paint over a coat of red oxide primer including taking out of old base frame and grouting new frame in the existing grouted bolts and nuts, complete all as specified and as directed. Note: (i) the quoted rate shall be inclusive of taking out of motor and refixing after completion of work. (ii) The contractor will make sure that the frame fixed is levelled and both pump and motor are fully aligned to work smoothly. (iii) any repair required in foundation will be inclusive in quoted rate by the contractor.
Supply in replacement of GI Pipe Heavy grade of size 40 mm bore, ISI marked for making long keys for operating deep down sluice valves of the swimming pool.
Material and labour for welding and fixing of suitable 'EYE' of 25 mm square from inside to 40 mm dia GI Heavy grade pipe, length 5 mtr for opening and closing for sluice valves with the help of circular wheel, inside a reservoir/sump/valve pit for pool operation complete all as specified and directed.
M&L for rewinding of motor 2HP to 3HP with super enamelled winding copper wire of existing size/gauge after cutting of buried winding including all insulation material such as insulation varnish , PVC copper cable lead glass fiber sleeves cotton tape insulation paper and heating in heat chamber at appropriate temp complete all specified and directed.
Repair/maintenance/ servicing to 3 phase electric driven air compressor with motor of capacity 5 HP Make: EVEREST BLOWER for filtration plant after disconnecting the electrical connection , dismantling, the compressor and motor from foundation taking to the civil workshop and carry out the repair by replacing compressor bearing gland packing , nut bolt and washer including necessary greasing , oiling , machining work for its smooth bringing back/fixing at its original position and testing complete including painting the complete set with 2 coat of synthetic enamel paint of approved colour complete all as specified and directed by Engr -in charge ( Rewinding of motor shall be measured and paid separately )
Supplying, injecting and mixing of alum sulphate in swimming pool through dozing system installed complete all as specified and directed by Engr-in-charge.
Supplying, injecting and mixing of soda ash in swimming pool through dozing system installed complete all as specified and directed by Engr-in-charge.
Supplying, injecting and mixing of TCC A90 in swimming pool through dozing system installed complete all as specified and directed by Engr-in-charge.
Supplying, injecting and mixing of copper sulphate in swimming pool through dozing system installed complete all as specified and directed by Engr-in-charge.
Supplying, injecting and mixing of HCL in swimming pool through dozing system installed complete all as specified and directed at site.
Supply and filling AQUAFIT brand calcium hypochlorite 65% to 70 % chlorine content (in drum) the form of granular and tablet complete all as specified and directed.
M&L for isolation of power supply from the existing electric panel , Lifting of submersible pumping set of any capacity from deep bore well of any depth with chain and pulley arrangement ,transportation of submersible pump set to civil workshop, returning back of pump set on site after repair work completed and lowering down the submersible pump set Complete all as specified and directed.
S&F in replacement nuts, bolts, rubber gasket complete set complete all as specified and directed by Engineer-in-charge.. Note :One job shall be inclusive of all nuts, bolts, washers and rubber gasket required for lifting/lowering of pipe line for one pumping set complete all as specified and directed by Engineer-in-charge.
M&L complete overhauling/repair of defective submersible pump/sewage pump of 5 HP to 7.5 HP ,dismantling of UNSV motor from pump set and opening the pump including cleaning of all parts, oiling/greasing, replacing of unserviceable parts such as CI connection piece, CI stage bowl, GM neck ring, remelting of GM impeller turning, GM DOL bush,SS stud with nut, water seal, revolving disc,EPV impeller,impeller key,repairing of stamping of stator,CI DOL piece,SS coupling with key,CI suction Piece. GM sand guard and any other parts of pump of capacity 5HP to 7.5 HP, 3 phase motor driven (excluding motor winding) cast iron/cast steel body complete and connecting with motor portion complete all as specified and directed.
M&L complete overhauling/repair of defective submersible pump/sewage pump of 10HP to 12.5 HP ,dismantling of UNSV motor from pump set and opening the pump including cleaning of all parts, oiling/greasing, replacing of unserviceable parts such as CI connection stage neck ring, remelting of GM impeller DOL bush,SS stud with seal, revolving disc,EPV impeller,impeller key,repairing of stamping of stator,CI DOL piece,SS coupling with key,CI suction Piece. GM sand guard and any other parts of pump of capacity 5HP to 7.5 HP, 3 phase motor driven (excluding motor winding) cast iron/cast steel body complete and connecting with motor portion complete all as specified and directed.
M&L in replacement of re-winding of motor of submersible pump /sewage pump set of capacity 5.0 HP to 7.5 HP (for Navy area and panchwati) with suitable size copper conductor wire after cutting of existing burnt winding including replacement of unserviceable parts such as GM bearing,Rotor sleeve,water seal,thrust bearing segment, thrust bearing counter, thrust plate, T-bolt, submersible cable jointing kit, revolving disc, Rotor sleeve, impeller, distance sleeve, guide bush,DOL sleeve,O ring,motor seal,CI lower housing and upper housing, diffuser,all insulating materials such as insulation varnish, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper and heating in heat chamber at appropriate temperature complete all as specified & directed.
M&L in replacement of re-winding of motor of submersible pump set of capacity 10 HP to 12.5 HP with suitable size copper conductor wire after cutting of existing burnt winding including replacement of unserviceable parts such as GM bearing,Rotor sleeve,water seal,thrust bearing segment, thrust bearing counter, thrust plate, T-bolt, submersible cable jointing kit, revolving disc, Rotor sleeve, impeller, distance sleeve, guide bush,DOL sleeve,O ring,motor seal,CI lower housing and upper housing, diffuser,all insulating materials such as insulation varnish, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper and heating in heat chamber at appropriate temperature complete all as specified & directed.
M&L for isolation of power supply from the existing electric panel , Lifting of sewage pumping set of any capacity from deep sewage well of any depth with chain and pulley arrangement ,transportation of sewage pump set to civil workshop, returning back of pump set on site after repair work completed and lowering down the pump set Complete all as specified and directed.
M&L for isolation of power supply from the existing electric panel, taking out unserviceable booster pump set of cap 7.5 HP by unscrewing of bolts of pumpset casing from MS base frame and keeping aside , transportation of booster pump to civil workshop, dismantling of UNSV pumpset in including cleaning of all parts, oiling/greasing including reassembling the same after repair , and back to site, fixing of repaired booster pump set on its original foundation making proper alignment , including restoration of power supply and testing, commissioning to the entire satisfaction of Engr-in-Charge.
M&L for isolation of power supply from the existing electric panel, taking out unserviceable booster pump set of cap 10.0 HP to 12.5 HP by unscrewing of bolts of pumpset casing from MS base frame and keeping aside , transportation of booster pump to civil workshop, dismantling of UNSV pumpset in including cleaning of all parts, oiling/greasing including reassembling the same after repair , and back to site, fixing of repaired booster pump set on its original foundation making proper alignment , including restoration of power supply and testing, commissioning to the entire satisfaction of Engr-in-Charge.
M&L for isolation of power supply from the existing electric panel, taking out unserviceable booster pump set of cap 25 HP by unscrewing of bolts of pumpset casing from MS base frame and keeping aside , transportation of booster pump to civil workshop, dismantling of UNSV pumpset in including cleaning of all parts, oiling/greasing including reassembling the same after repair , and back to site, fixing of repaired booster pump set on its original foundation making proper alignment , including restoration of power supply and testing, commissioning to the entire satisfaction of Engr-in-Charge.
M&L for isolation of power supply from the existing electric panel, taking out unserviceable booster pump set of cap 100 HP by unscrewing of bolts of pumpset casing from MS base frame and keeping aside , transportation of booster pump to civil workshop, dismantling of UNSV pumpset in including cleaning of all parts, oiling/greasing including reassembling the same after repair , and back to site, fixing of repaired booster pump set on its original foundation making proper alignment , including restoration of power supply and testing, commissioning to the entire satisfaction of Engr-in-Charge.
M&L for rewinding of 7.5 HP booster motor with new super enamelled winding copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish, bush, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper, bearing sleeve, pump shaft welding, turning, grinding, making key way,TC coupling,CI impeller,CI interstage ring,gland packing,wear ring,bearing housing,fastener,air release valve,eye bolt,ball bearing,water liquid deflector,motor & pump coupling and heating in heat chamber at appropriate temperature complete all as specified and directed.
M&L for rewinding of 10.0 HP to 12.5 HP booster motor with new super enamelled winding copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish, bush, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper, bearing sleeve, pump shaft welding, turning, grinding, making key way,TC coupling,CI impeller,CI interstage ring,gland packing,wear ring,bearing housing,fastener,air release valve,eye bolt,ball bearing,water liquid deflector,motor & pump coupling and heating in heat chamber at appropriate temperature complete all as specified and directed.
M&L for rewinding of 25 HP booster motor with new super enamelled winding copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish, bush,PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper, bearing sleeve, pump shaft welding, turning, grinding, making key way,TC coupling,CI impeller,CI interstage ring,gland packing,wear ring,bearing housing,fastener,air release valve,eye bolt,ball bearing,water liquid deflector,motor & pump coupling and heating in heat chamber at appropriate temperature complete all as specified and directed.
M&L for rewinding of 100 HP booster motor with new super enamelled winding copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish, bush,PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper, bearing sleeve, pump shaft welding, turning, grinding, making key way,TC coupling,CI impeller,CI interstage ring,gland packing,wear ring,bearing housing,fastener,air release valve,eye bolt,ball bearing,water liquid deflector,motor & pump coupling and heating in heat chamber at appropriate temperature complete all as specified and directed.
Taking out Manhole cover and Desludging the existing manhole septic tank including removing of Sludge/Mud/Muck, Desilting/Dechoking with combine high pressure water jetting cum suction (Vacuum) type machine mounted on LCV/HCV and disposed off outside MD land and blocking of the sewage line of septic tank to stop the entry of waste water/sludge/mud in sewage well at palam bagh/panchwati.
M & L for disposal of waste water up to 06 feet depth of Sewage well and 04 Feet depth of Man Hole by using Portable sewage pumping set of capacity 7.5 HP and filling of waste water in a covered trolley and disposed off outside MD land all as specified and directed.
M & L for removal of Sludge/Mud/Muck/Waste material/Silt upto a depth of 14 feet , Desilting/Dechoking with high pressure super socker machine and cleaning of surface of sump of sewage well using wire brushes and other scrapping tools to remove dirt and scales to make it free from all deposits and disposed of the same to outside MD land all as specified and directed.
Opening of Manhole cover and connecting of the sewage line of septic tank with sewage well complete all as specified and directed by Engineer-in-charge.
M&L for development of tube well for improvement of water yield by 210 CFM compressor including taking out existing submersible pump set complete with pipe and cable and lowering the same after water yield improvement including necessary transportation and minor spare parts complete all as specified.
S&F in replacement of Cosmic Star Standard Automatic Star Delta Starter/controller for submersible /mono block pump set of capacity 12.5 HP comprising of item Single phasing preventor, overload relay, Auto/Manual Switch, Amp meter, voltmeter, ON/Off Push Button, Light indicator and other connected accessories in housing in Sheet steel enclosure including connection in existing system with cable and all arrangement complete all as specified and directed. Make:- Havells/ L&T/ Standard.
S&F in replacement of Cosmic Star Standard Automatic Star Delta Starter/controller for submersible /mono block pump set of capacity 10 HP comprising of item Single phasing preventor, overload relay,Auto/Manual Switch, Amp meter, voltmeter, ON/Off Push Button, Light indicator and other connected accessories in housing in Sheet steel enclosure including connection in existing system with cable and all arrangement complete all as specified and directed. Make:- Havells/ L&T/ Standard.
S&F in replacement of DOL Direct Online Starter suitable for submersible pump set/ mono block/sewage pump set of capacity 7.5 HP comprising of item Single phasing preventor, overload relay,Auto/Manual Switch, Amp meter, voltmeter, ON/Off Push Button, Light indicator and other connected accessories in housing in Sheet steel enclosure including connection in existing system with cable and all arrangement complete all as specified and directed. Make:- Havells/ L&T/ Standard.
S&F in replacement of DOL Direct Online Starter suitable for submersible pump set/ mono block pump set of capacity 5 HP comprising of item Single phasing preventor, overload relay,Auto/Manual Switch, Amp meter, voltmeter, ON/Off Push Button, Light indicator and other connected accessories in housing in Sheet steel enclosure including connection in existing system with cable and all arrangement complete all as specified and directed. Make:- Havells/ L&T/ Standard.
S & F in replacement waterproof submersible copper cable flat 6 Sqmm 3 core for bore well of any depth with fitting and connections complete all as specified and as directed.
S & F in replacement of GI water tubing, medium grade, galvanised (ISI marked as IS-1239), with all fittings including short lengths, fixed to walls, fixed in sewage well, U/G sump, concealed in wall and ceiling or laid in floor trench complete with all fittings (such as bends, elbows, flanges Tee, short pieces,reducer,nipple, connectors, back nuts, diminishing pieces, caps and plugs, unions etc), complete, all as specified and directed, of the following sizes:-
100 mm bore
80mm bore
50mm bore
40mm bore
25mm bore
20mm bore
15mm bore
S&F in replacement of MS ERW pipe heavy duty welded joint together with fittings such as bends, elbow, tee equal, short pieces fixed on walls duly supported with clamps, wall hooks wooden plugs with other accessories including cutting through walls/floor and making good to the disturbed surface complete all as specified and as directed of the following sizes:-
All as per item No. 49 here-in-before but 150 mm dia
All as per item No. 49 here-in-before but 100 mm dia
All as per item No. 49 here-in-before but 80 mm dia
M & L for excavation by trenchless boring technology for holes under road pavement, hard standing using ultra sound technique and engaging necessary machine including HDPE pipe ISI marked of dia 200 mm suitable for 0.4 Mpa working pressure complete all as specified and directed Note: HDPE pipe and marking good the disturbed surface shall deemed to be included in quoted rate.
S&F in replacement of Hose box made of 18 gauge MS sheet 800 mm X 600 mm X 450 mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard
supply and fix in replacement of Yard hydrant Post / Stand Post 80mm Dia GI / MS both flanged type 1.5m Height
supply and fix in replacement of 63mm dia instantaneous pattern oblique single headed internal hydrant valve.
supply and fix in replacement of 15 mtr 63mm dia controlled CP Hose with gun metal female instantaneous coupling as required.
supply and fix in replacement of 15 mtr 63mm dia controlled RRL Hose with gun metal female instantaneous coupling as required.
Supply and fix in replacement of 4 way Fire Brigade connection having 63mm dia instantaneous type inlet and 150 mm dia flange outlet conforming to IS 904 with blank cap and chain with necessary pipe and flanges nuts, bolts etc
Supply and fixing in replacement of 3 way Fire Brigade connection having 63mm dia instantaneous type inlet and 100 mm dia flange outlet conforming to IS 904 with blank cap and chain with necessary pipe and flanges nuts, bolts etc
supply and fix in replacement of 20mm dia bore reinforced rubber of length 36m fitted with 6.35mm dia nozzle with a ball valve. The hose reel shall be recessed swinging type with reel drum hose provided with necessary couplings.
supply and fix in replacement of Pressure gauge 4"dial 0-14 kg/sqcm rating
Providing and fixing in replacement of differential type pressure switches for operation of fire pumps. Make Denfoss or equivalent
Preventive and comprehensive maintenance of complete fire alarm system(s) installed at Chiman Block (G+8) in reliable, safe and efficient manner using latest techniques & expertise by regularly examining the sensor/detector, Main fire alarm control panels, Repeater panels, Hooters, MCP, Sirens etc of various type / capacity / make, including making the non-functional parts of fire alarm system into fully functional condition, attending day to day complaint / fault(s) in general shift of 08 hrs every day incl Sunday & holiday, including quarterly cleaning of the detectors and monthly joint testing/inspection of the complete fire alarm system, including replacement of minor items such as wire, lugs, nut, bolts, screws, electronic circuit, chip etc complete all as specified and directed by Engr- in- charge. Note : (i) The complete fire alarm system(s) will be handed over to contractor in existing condition and no claim on this effect will be accepted at any stage. Hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract and quote their rates accordingly. (ii) The cost of all kind of repair /servicing/ replacement of defective equipment/devices and other minor parts/spares or cell/ batteries as and when required for making the entire fire alarm system(s) fully functional, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor on this effect. However, the Cost of major equipment / devices shall be measured & paid separately under relevant item of this Schedule.
M&L in replacement of intelligent analog emitter with microprocessor based controller based on radio waves with supported manual call point and hooter with 110DB output in MS body, works on 220 volts used for repeating signals to main control panel or as per existing make and model complete all as specified and directed by Engr- in- charge.
S&F in replacement of cast iron sluice valve, 150mm bore, hand wheel operated , non rising type with steel spindle complete with flanged ends and gun metal parts including necessary nut, bolts, washers and rubbers gaskets, 3mm thick, heavy duty and iron wheel all as per site requirement complete with jointing material including taking out old unserviceable sluice valve complete all as specified
S&F in replacement of cast iron sluice valve, 100mm bore, hand wheel operated , non rising type with steel spindle complete with flanged ends and gun metal parts including necessary nut, bolts, washers and rubbers gaskets, 3mm thick, heavy duty and iron wheel all as per site requirement complete with jointing material including taking out old unserviceable sluice valve complete all as specified
S&F in replacement of cast iron Gate/sluice valve, 80mm bore, hand wheel operated ,non rising type with steel spindle complete with flanged ends and gun metal parts including necessary nut, bolts, washers and rubbers gaskets, 3mm thick, heavy duty and iron wheel all as per site requirement complete with jointing material including taking out old unserviceable sluice valve complete all as specified
S&F in replacement of non return valve, 150mm with flanged ends ,doors and discs cast integral cast hinge lugs to allow free door and disc operation without by pass arrangement, including necessary nut, bolt, washer and rubber gaskets, 3mm thick, heavy duty all as per site requirement including taking out old existing unserviceable non return valve of the size 150mm dia all as specified.
S&F in replacement of non return valve, 100mm with flanged ends ,doors and discs cast integral cast hinge lugs to allow free door and disc operation without by pass arrangement, including necessary nut, bolt, washer and rubber gaskets, 3mm thick, heavy duty all as per site requirement including taking out old existing unserviceable non return valve of the size 100mm dia all as specified.
S&F in replacement of non return valve, 80mm with flanged ends ,doors and discs cast integral cast hinge lugs to allow free door and disc operation and without by pass arrangement, ISI marked including necessary nut, bolt, washer and rubber gaskets, 3mm thick, heavy duty all as per site requirement including taking out old existing unserviceable non return valve of the size 800mm dia all as specified.
S&F in replacement of cast iron body butterfly valve, wafer type, gear operated with stainless steel disc of size 150mm, with integrally moulded rubber lining of silicon, double flange all as per site requirement complete all as specified.
S&F in replacement of cast iron body butterfly valve, wafer type, gear operated with stainless steel disc of size 100mm, with integrally moulded rubber lining of silicon, double flange all as per site requirement complete all as specified.
S&F in replacement of cast iron body butterfly valve, wafer type, gear operated with stainless steel disc of size 80mm, with integrally moulded rubber lining of silicon, double flange all as per site requirement complete all as specified.
S&F in replacement of cast iron body foot valve with strainer, single door, swing check type of size 150mm with all the material and components, flanged ends all as per site requirement complete all as specified .
S&F in replacement of cast iron body foot valve with strainer, single door, swing check type of size 100mm with all the material and components, flanged ends all as per site requirement complete all as specified .
S&F in replacement of cast iron body Y strainer of size 150mm with all the material and components, flanged ends all as per site requirement complete all as specified .
S&F in repair 40 mm dia gate valve, gun metal, heavy duty screwed down both ends with iron wheel head after taking down old existing gate valve complete all as specified and directed at site.
S&F in repair 20/25 mm dia gate valve, gun metal, heavy duty screwed down both ends with iron wheel head after taking down old existing gate valve complete all as specified and directed at site.
S&F in repair 15 mm dia gate valve, gun metal, heavy duty screwed down both ends with iron wheel head after taking down old existing gate valve complete all as specified and directed at site.
Comprehensive maintenance and repair of 62.5 KVA DG Set with AMF including servicing,oiling,greasing and replacement of defective parts/ fitting including all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period.. Make- Jackson Note:-The quoted rate shall be inclusive of spare parts required for smooth functioning of DG set.
M&L for cleaning of RCC underground water sump of approx. capacity upto 455000 Ltrs by removing the mud/settled bleaching powder and all other foreign material from the sump and depositing where directed but not less than 50 mtr from the starting point including scraping / removing all dirt/scales from the internal wall of the sump and washing the bottom surface and wall surface of the sump with clean water, draining out the dirty water so that the whole sump be thoroughly cleaned after pumping out all existing water by portable centrifugal/mono block submersible pumping set, applying one coat of bleaching powder on the all inner wall surface of sump including bottom surface and writing the date of cleaning on the sump complete all as directed at site by AGE E/M New Delhi.
Comprehensive, preventive and periodical maintenance of washer extractor (03 Nos) of capacity 60 Kg per charge Make: STEFAB/FEBCARE installed at NOM-Varuna in reliable, safe and efficient manner by regular examining, lubricating and adjusting the mechanical and electrical driving equipment including replacement of defective / spares parts as "Supply only" and testing on completion to the entire satisfaction of Engr-in-charge complete all as specified. (Note:- (i) The contractor shall have MOU for providing service and material with Laundry plant manufacturer, M/s STEFAB, FEBCARE, (ii) Spare parts to be replaced as listed in sch 'A' to be measured and paid separately as supply only. Fixing charge is deemed to be included in item No. 83.(iii) All the complaints will be rectify within 24 hrs from the time of receipt of complaint. If contractor fails to rectify the complaint within 24 hrs from the time of receipt of complaint, the compensation / penalty of Rs 500.00 per complaint per day shall be recovered from the contractor's dues.) (iv) Any items not covered under as supply only shall be deemed to be included in this section for the smooth functioning of laundry plant and the contractor may quote the rate accordingly. Contractor is expected to inspect the laundry plant at NOM Varuna before quoting the rate.
Supply only in replacement Programmable Logical Card (PLC) ST-6 type complete all as directed
Supply only in replacement of V-Belt of suitable size for 60 Kg per charge washer extractor complete all as specified.
Supply only in replacement of filter regulator suitable for 10 bars maximum pressure & 0.5-10 bars pressure range suitable for 60 Kg per charge washer extractor complete all as specified.
Supply only in replacement of lubricator suitable for 10 bars maximum pressure suitable for 60 Kg per charge washer extractor complete all as specified.
Supply only, in replacement of main shocker suitable for Washer Extractor of 120 Kg capacity including nut,bolt and washer complete all as specified and directed by Engr-in-Charge.
Supply only, in replacement of main spring heavy duty suitable for Washer Extractor of 120 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only, in replacement of door lock latch handle suitable for Washer Extractor of 120 Kg capacity complete all as specified and directed by Engr-in-Charge. As per existing sample.
Supply only in replacement of pneumatic cylinder kit for FPE-150 suitable for 60 Kg per charge washer extractor complete all as specified.
Supply only in replacement of filter suitable for 60 Kg per charge washer extractor complete all as specified.
Supply only in replacement of flexible Hose pipe of suitable length and size for 60 Kg per charge washer extractor complete all as specified.
Supply and Fixing, in replacement of Main bearing set of size (6315,2RS and 6316,2RS) of suitable dia and thickness for Washer Extractor of 60 Kg complete all as specified and directed by Engr-in-Charge.
Supply and Fixing, in replacement of Main bearing seal set of vieton suitable for Washer Extractor of 60 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of Digital Display Controller Unit (AWX-60) suitable for 60 Kg extractor complete all as specified.
Supply only in replacement variable frequency drive suitable for 60 Kg per charge washer extractor complete all as specified
Comprehensive, preventive and periodical maintenance of drying tumbler (02 Nos) of capacity 60 Kg per charge Make: STEFAB/FEBCARE installed at NOM-Varuna in reliable, safe and efficient manner by regular examining, lubricating and adjusting the mechanical and electrical driving equipment including replacement of defective / spares parts as "Supply only" and testing on completion to the entire satisfaction of Engr-in-charge complete all as specified. (Note:- (i) The contractor shall have MOU for providing service and material with Laundry plant manufacturer, M/s STEFAB, FEBCARE, (ii) Spare parts to be replaced as listed in sch 'A' to be measured and paid separately as supply only. Fixing charge is deemed to be included in item No. 83.(iii) All the complaints will be rectify within 24 hrs from the time of receipt of complaint. If contractor fails to rectify the complaint within 24 hrs from the time of receipt of complaint, the compensation / penalty of Rs 500.00 per complaint per day shall be recovered from the contractor's dues.) (iv) Any items not covered under as supply only shall be deemed to be included in this section for the smooth functioning of laundry plant and the contractor may quote the rate accordingly. Contractor is expected to inspect the laundry plant at NOM Varuna before quoting the rate
Supply only, in replacement of Steam Heating Coil having Copper Tube with Aluminium Fins suitable for Drying Tumblers of 60 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only in replacement Programmable Logical Card (PLC) ST-4 type complete Make Stefab complete all as directed
Supply only in replacement of contactor 4 pole 230 volts of capacity 40 Amps all as directed make :L&T/C&S
Supply only in replacement of Digital Display Controller Unit suitable for 60 Kg per charge drying tumbler complete all as specified.
Supply only in replacement of lubricator suitable for 60 Kg per charge drying tumbler complete all as specified.
Supply only in replacement of water solenoid valve size 25mm with diaframe inside suitable for 60 Kg drying tumbler complete all as specified.
Supply only in replacement of Automatic steam inlet valve suitable for 60 Kg drying tumbler complete all as specified.
S&F in replacement of heating element 6 KW, 240 volts, 50 Hz suitable for solar water heating unit all as specified.
S&F in replacement of thermostat suitable for solar water heating unit all as specified.
Supply only, in replacement of padding set suitable for Flat bed Press complete all as specified and directed by Engr-in-Charge.
Supply only, in replacement of main bearing suitable for Flat bed Press complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of Table switch suitable for 60 Kg per charge STEFAB/FEBCARE Make washer extractor complete all as specified
comprehensive, preventive and periodical maintenance including replacement of defective spare parts of Steam Boiler of 10 Kg capacity (Make : stefeb/Febcare) by engaging sufficient man power and suitable T&P to ensure safety of boiler as well as working persons including disconnecting of water / steam / electric connections, dismantling of boiler plant by unscrewing/cutting of screws, nuts & bolts etc, taking out complete coil assembly and other major parts from the boiler etc, replacing all defective spares parts (Spare parts shall be measured and paid in this section ) cleaning / servicing of coil assembly incl electrical control panel board, all machine works i.e. welding, cutting, drilling etc as and when required and reassembling all dismantled part/items after carrying out necessary repair as required, other material, cleaning, servicing, oiling, greasing etc, making all steam / water connection and electrical connection, leak testing at desired pressure, with and including testing, commissioning of complete boiler plant in original location for smooth and trouble free operation, to entire satisfaction of Engineer-in-charge, complete all as specified and directed by Engr-in-Charge.
Supply & Fix in replacement of flannel cloth suitable for Flat Work Ironer Machine complete including anchoring iron rod clip complete all as specified and directed by Engr-in-Charge. As per existing sample.
Supply & Fix in replacement of Flate bed press/ironer suitable for Washer Extractor of 60 Kg capacity complete all as specified and directed by Engr-in-Charge. Make : As per existing sample.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to starter panel all complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of old unserviceable overload relay suitable for 25 HP motor and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable contactor suitable for 25 HP motor and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable single phase preventor and connected internal wiring suitable for 25 HP motor starter complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable phase sequence corrector relay 440V , 50 HZ Supply suitable for 25 HP motor starter and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable overload relay suitable for 100 HP motor and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable contactor suitable for 100 HP motor and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable single phase preventor and connected internal wiring suitable for 100 HP motor starter complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable phase sequence corrector relay 440V , 50 HZ Supply suitable for 100 HP motor starter and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable overload relay suitable for 12.5 HP motor and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable contactor suitable for 12.5 HP motor and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable single phase preventor and connected internal wiring suitable for 12.5 HP motor starter complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable phase sequence corrector relay 440V , 50 HZ Supply suitable for 12.5 HP motor starter and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable indication lamp in R,Y,B colour and connected internal wiring in for motor starter complete all as specified and directed by Engineer-In-Charge.
S & F in replacement of old unserviceable Rotary switch and connected internal wiring in for motor starter complete all as specified and directed by Engineer-In-Charge.
S & F in replacement of old unserviceable push button and connected internal wiring in for motor starter complete all as specified and directed by Engineer-In-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of GI pipes or other items and getting out soil in any type soil complete all as specified.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engr-in-charge.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified and directed by Engr-in-charge
verma enterprises
NEERU ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .