Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹44.5 L+₹73,259 (1.68%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹46.0 L+₹2.3 L (5.25%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹48.1 L+₹4.3 L (9.92%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹49.8 L+₹6.1 L (14.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
3 Jan 2022, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIR/REPLACEMENT OF OLD U/S AND OBSOLETE STREET LIGHT (PREIMETER) IN TO LED STREET LIGHTS AT LGJ MIL STN
2021_MES_493144_1
8932-64/21-22
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class D cat b(i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹94,000
Yes
10 Feb 2022
13 Dec 2021
5 Jan 2022
13 Dec 2021
3 Jan 2022
27 Dec 2021
Amount
Taking down old street light fittings of any wattage/size from guard post bldg/LT poles after disconnecting all electrical connection /cheselling the welded bracket complete all specified and directed by Engineer-in-Charge.
Supply and fixing in repairs on existing cross arm and testing pole mounted LED flood light fittings 60 watt, 230 volts 50 Hz made out of pressure die cast aluminium housing, power coated with toughned glass and individual LEDs with secondary optics and IP66 protection not less than 100 luman/watt and beam angle greater than 120 degree and HF electronic driver complete all specified and directed by Engineer-in-Charge..
Supply and fixing in repairs on existing cross arm and testing pole mounted LED flood light fittings 120 watt, 230 volts 50 Hz made out of pressure die cast aluminium housing, power coated with toughned glass and individual LEDs with secondary optics and IP66 protection not less than 100 luman/watt and beam angle greater than 120 degree and HF electronic driver complete all specified and directed by Engineer-in-Charge..
Supply and fixing in repairs on existing cross arm and testing pole mounted LED flood light fittings 30 watt, 230 volts 50 Hz made out of pressure die cast aluminium housing, power coated with toughned glass and individual LEDs with secondary optics and IP66 protection not less than 100 luman/watt and beam angle greater than 120 degree and HF electronic driver complete all specified and directed by Engineer-in-Charge..
M&L in repairs weather proof single core cable with aluminium conductor 2.5 sqmm from junction box to LED light, 3 core, neutral and earth complete all specified and directed by Engineer-in-Charge.
M&L for rigid non-metallic PVC conduit 20mm dia incl fixing accessories such as couplers, lock nuts, saddled, pipe hooks etc complete all specified and directed by Engineer-in-Charge.
M&L in repairs loop in, loop out junction box of minimum size 250x200x105mm, three phase, 4 wire out door type, IP 65, made out of polycarbonate with glass fiber re-inforced pole mounting consisting of aluminium bus bar strip 150x20x3mm, 4 Nos fixed on porcelain insulator and provision of incoming/outgoing cables with gromets including 01 No inbuilt 1 amp to 6 Amp MCB, SP, 10KA complete all specified and directed by Engineer-in-Charge. Make :Sintex GSJB2520 or similar in Hansel or legrand or havells
M&L in repairs for cross arms, bracings, supports, clamps and back plates fabricted from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all specified and directed by Engineer-in-Charge.
Supplying, laying and testing in replacement of XLPE LT Cables of size 16SQMM, 4 core, 1100 volt grade heavy duty with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with Galvanised steel strip and over all PVC sheathed stranded conductor conforming to IS-7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all specified and directed by Engineer-in-Charge. Note : (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate of this schedule
Excavation in trenches for laying of cable for pole & stay n.exc 1.5 mtr wide & n. exc 1.5 mtr in depth & getting out in soft/loose soil complete all specified and directed by Engineer-in-Charge.
Removing the excavated material(soil) upto a distance n.exc 50mtr & depositing where directed a level n. exc. 1.5 mtr above the starting point complete all specified and directed by Engineer-in-Charge.
Returining & filling in including sparding levelling, watering &well ramming in layers n.exc 1.5 mtr above starting point in soil complete all specified and directed by Engineer-in-Charge.
M&L sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all specified and directed by Engineer-in-Charge. Note : Punned thickness shall be considered for payment purpose.
Supply and laying best quality locally available Sub class 'B' bricks (old size) for cable protection cover, laid flat and lay in trenches over the cable complete all specified and directed by Engineer-in-Charge
M&L for tubing GI light grade 40mm bore for installation of cable including fixing arrangement all as required and complete all specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 60cm x60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the warth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement consrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No 3 of MES Schedule Part -I of SSR 2009. Note :- (i) 20mm dia GI pipe for watering to be provided with a socket and plug and should be 10cm above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chember. (iii) GI wire upto DBs earth connection is included in this item. (iv) Water pipe shall be provided in slanting position.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
DHAWAN CONSTRUCTION COMPANY
M/s R.N Construction Co.
Singla Electricals
ram rattan dass aggarwal
KHANNA CONSTRUCTIONS
Soma Enterprises
Ganganagar Enterprises
SHIVA CONSTRUCTION COMPANY
Aggarwal brothers and company
AYUSH BUILDERS
Dashmesh Construction Company
M/S KARNI CONSTRUCTION COMPANY
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .