Tender Value
₹23.2 L
EMD Value
₹46,400
Closing Date
21 Apr 2022, 6:00 pmClosed
Commander Works Engineer Bhopal
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
SPECIAL REPAIRS TO ROAD IN UNIT AOR AND OFFICERS MESS OF 210 RKT REGT AT NASIRABAD MIL STN UNDER GE NASIRABAD
2022_MES_515463_1
83742/E8
Open Tender
Civil Works - Roads
Item Rate
180 days
NASIRABAD
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
GE Nasirabad
₹46,400
Yes
24 May 2022
26 Mar 2022
23 Apr 2022
26 Mar 2022
21 Apr 2022
9 Apr 2022
26 Mar 2022 - 9 Apr 2022
Amount
Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exceeding 400 sqm, depth of pot hole exceeding 50 mm but not exceeding 100 mm including rolling over the broken surfaces using 8 to 10 tonnes power roller to required camber and gradient complete all as specified and as directed.
M & L for 7.5 cm thick (compacted thickness) WBM, with coarse aggregates of granite, trap or basalt of grading 2 (63 to 45 mm size) or of grading 3 (53 to 22.4 mm size), spread, rolled and compacted to required gradient and camber with three wheel-power roller of 80 to 100 kN capacity or an equivalent vibratory roller complete all as specified and as directed.
Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and as directed.
M & L for applying primer on the surface of non-bituminous granular base course preparatory to the superimposition of bituminous treatment coat with cationic bitumen emulsion SS-1 grade at the rate of 10 kg per 10 Sqm of surface complete all as specified and as directed.
M & L for applying tack coat on existing bituminous, cement concrete or primed granular surface to ensure a bond between the surface being paved and the overlaying course with cationic bitumen emulsion RS-1 grade at the rate of 3 kg per 10 sqm of surface complete all as specified and as directed.
M & L for semi dense bituminous concrete 40 mm (compacted thickness) using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 4.5% by weight of total mix & hydraulic lime filler, rolled and compacted to required camber and gradient complete all as specified and as directed. Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.
Repair to potholes any depth, not exceeding 1 sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc., cutting around edges to at least 25 mm in depth, making good by filling in screened & graded road metal, watering and well ramming (including supply of road metal), rolled and compacted with power roller 8 to 10 tonnes to required gradient and camber complete all as specified and as directed.
Preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and as directed.
M & L for preparation of existing black top surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. and applying tack coat on existing bituminous to ensure a bond between the surface being paved and the overlaying course with paving grade bitumen VG-10 grade at the rate of 5 kg per 10 sqm of surface complete all as specified and as directed.
M & L for semi dense bituminous concrete 30 mm (compacted thickness) using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 5% by weight of total mix & hydraulic lime filler, rolled and compacted to required camber and gradient complete all as specified and as directed. Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.
M & L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M & L for lime or sand stone kerb of roughly rectangular stones of size 50 to 80 mm (thick) X 300 mm (height) X not less than 600 mm (length), dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6 mm for top and exposed surfaces of sides and 20 mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush complete all as specified and as directed.
Providing and fixing Glow studs (cat's eye) of size 80 to 100 mm X 80 to 100 mm X 15 to 20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The cat’s eye shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35⁰ ± 5⁰ to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 Part 4: 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete all as specified and as directed.
S & F Aluminium Composite Materials (ACM) signboard, 4 mm overall thickness, sandwiched construction with a thermoplastic core of 'Low Density Polyethylene' (LDPE), aluminium skin thickness of 0.4 - 0.5 mm and 0.25 - 0.3 mm respectively on both sides, a fluorocarbon coating applied over the exposed surface of aluminium, Type-IV high intensity retro-reflective sheeting made of micro-prismatic retro-reflective element material coated with pressure sensitive adhesive on top surface with aluminium surface, digitally colour printed indicating necessary sign, all as mentioned in IRC 67-2012 complete all as specified and as directed by Engineer-in-charge.
S & F solar road studs of size not less than 100 mm X 100 mm X 10 mm made of weather resistance aluminium alloy and poly carbonate material electronically welded micro- prismatic lens with abrasion resistant coating as approved by the Engineer in charge. The cats eye shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35⁰ ± 5⁰ to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM E: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge. The solar panel shall be high efficiency mono crystalline 2.5 V/60 m A and the battery shall be one Ni-mh type (1.2 V/1200 m Ah) high temp for backup of 36 hours full charging. The flash frequency shall be 60 ± 5 times per minute.
M/s ESS KAY Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .