Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹85.3 LAccepted-AOC 5A 582 CALDWELL COLONY TUTICORIN 628008 | TUTICORIN | THOOTHUKUDI | TAMIL NADU | 628008 | 1 | Accepted-AOC L1 Tenderer | |
| 2 | 2₹87.6 L+₹5.2 L (6.28%)Rejected-AOC D 2 D 3 SIDCO INDUSTRIAL ESTATE METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | 2 | Rejected-AOC L2 Tenderer |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
7 Nov 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE NCTPPS II
Office of Chief Engineer NCTPS II CHENNAI 120
NCTPS II M I Circle BM Unit I AOH 2024 25 Replacement of defective front RE-heater tube affected by oxide
2024_EB_498245_1
CE NCTPS II SE M I O M 221 2024 25
Open Tender
Miscellaneous Works
Item Rate
40 days
SE MI NCTPS II
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹80,000
Yes
23 Apr 2025
2 Nov 2024
8 Nov 2024
2 Nov 2024
7 Nov 2024
2 Nov 2024
Amount
Providing special type platform to access the Re-heater coils for the entire re heater bottom area and back pass screen tube area for facilating Oxide scale thickness measurement and renewal of oxide scale formed tubes. The charges for transportation of scaffolding materials and consumables to the boiler rear arch slope area, erecting the (64mtrs height x 3 mtrs width) scaffolding and temporary platform for facilitating attending the above work. After completion work, removing the scaffolding and temporary platform from the area and shifting back the scaffolding materials. Charges inclusive of T&P's and consumables.
Replacing of Oxide scale deposited tubes /bends by new bends/ tubes : Cutting and removing of Oxide scale deposited front re-reheater tubes / bends by arc cutting by using special electrodes for a affected length portion from the coil assembly, edge preparation of tube ends , Positioning and new tubes/ bends by tag welding. Welding the tube joint with IBR welder.(argon gas, welding generator, TIG set and special welding electrodes will be the scope of contractor.) Charges inclusive of cost of consumables and T&Ps.
Supply of Various sizes of Boiler pressure parts bends suitable for Front Re-Heater coils of 600WM unit- I Boiler (As per the enclosed drawing), Note All the supply tubes should satisfy the following condition:- A). IBR Test Certificate in form - III B to be Furnished. B). Material test certificate I.E., Chemical Composition / Mechanical properties of the mateiral should be tested and furnished with relevant standards in Government / Goverment accredited laboratory. The testing method and test result with reference limits, etc., shall be furnished in the test certificate. C). The material quality such as chemical coposition is to be ensured by the supplier using material analyser in the presence of board engineer at NCTPS-II. Necessaery highly specialized PMI instruments should be arrange by the supplier at this own cost. D). All tubes are to be painted with primer coating and provided with end caps.
Supply of Reheater Front coil tube (Circuit 01) bottom outer 90° bends. Size: OD 76.1 x 5 thk x 1398mm R391, 90° Material: SA213 TP 347H , As per drawing enclosed
Supply of Reheater Front coil tube (Circuit 02) bottom outer 90° bends, Size: OD 63.5 x 4 mm thk x Length = 1302.7mm, R320, 90° Material: SA213 TP 347H, As per drawing enclosed
Supply of Reheater Front coil Tube bend circuit No.3 to 8 - bend OD 63.5 x 5mm thk x Length = 1314mm, R200, 90° bends, Matl:SA213T91, As per drawing enclosed
Supply of Reheater Front coil Tube bend circuit 9 - bend 63.5 x 5mm thk x Length = 1310mm, R200, 90° bends, Matl:SA213T91 , As per drawing enclosed
Supply of Reheater Front coil Tube bend circuit No.10 - bend, 63.5 x 5mm thk x Length = 1230mm, R200, 90° bends, Matl:SA213T91, As per drawing enclosed
Supply of Reheater Front coil Tube bend circuit No.11- bend, 63.5 x 5mm thk x Length = 1007mm, R200, 90° bends, Matl:SA213T91, As per drawing enclosed
Supply of Reheater Front coil Tube bend circuit No.12- bend 63.5 x 5mm thk x Length = 877mm, R200, 180° bends, Matl:SA213T91, As per drawing enclosed
FIROZE FABRICATORS (BID ID -1180537)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .